header advert
Results 1 - 1 of 1
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 453 - 454
1 Sep 2009
Barrios C Gòmez-Benito M Botero D García-Aznar J Doblaré M
Full Access

A recently developed parametric geometrical finite element model (p-FEM) was adapted to the specific hip geometric measurements of a group of patients with slipped capital femoral epiphysis (SCFE). The objective was to analyze the stress distribution in the growth plate of these patients and to evaluate differences for those patients who developed bilateral disease.

Different geometric parameters were measured in the healthy proximal femur of 18 adolescents (mean age, 12,1 yr) with unilateral SCFE and in 23 adolescents matched in age without hip disease (control group). Five patients developed SCFE in the contralateral side during follow-up. Different geometric measurements were taken from hip conventional X-ray studies. The p-FEM of the proximal femur permits modifications of different geometrical parameters, therefore the X-ray measurements taken from each patient were applied to the model obtaining a subject-specific model for each case. In each model, different mechanical situations such as walking, stairs climbing and sitting were simulated by applying loads on the femoral head corresponding to each own weight. The risk for growth plate failure was estimated by the Tresca, von Misses and Rankine stresses.

In summary, the models shows important differences between the stresses computed at the healthy femurs of patients with unilateral SCFE and femurs that further underwent bilateral SCFE. So, the 95% confidence interval of the percentage of volume of the growth plate subjected to stresses higher than 2MPa was almost similar for the control group and patients with unilateral SCFE. However, those patients who developed bilateral disease had statistically significant large physeal areas with more than 2.0 MPa (p< 0.005). Stresses were also strongly dependent on the geometry of the proximal femur, especially on the posterior sloping angle of the physis and the physeal sloping angle.

In spite of simplifications of the developed p-FEM, this tool has been able to show the influence of femur geometry in growth plate stresses and to predict the sites where growth plate starts to fail.