header advert
Results 1 - 8 of 8
Results per page:
Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 77 - 77
1 May 2016
Nakata K Kitada M Tamura S Owaki H Fuji T
Full Access

Introduction

Short stems have been developed for some years for preservation of femoral bone stock and achieve physiological proximal loading. Shortening stem length is a merit for bone stock preservation. However, it might lead to reduction of primary stability. We investigated relationship between stem length and primary stability by patient specific finite element analysis (FEA).

Materials and Methods

Thirty-one hips in 31 patients were performed total hip arthroplasty with standard length tapered wedge-shaped (TW) cementless stem (CTi-II: Corin, Cirencester, UK). There were 6 males and 25 females. The average age at operation was 69 years old. The average body mass index was 23.9 kg/m2. Primary diagnoses were secondary osteoarthritis due to developmental dysplasia of the hip in 29 hips. Femoral canal shapes were normal in 21, stovepipe in 6 and champagne-flute in 4 hips. Bone qualities were type A in 6, B in 19 and C in 6 hips.

The patients underwent computed tomography (CT) preoperatively and postoperatively. We constructed preoperative three dimensional (3D) femur surface models from preoperative CT data with individual bone mineral density (BMD) mapping. The postoperative 3D femur and rough stem surface models were obtained from postoperative CT data. The coordinates of the postoperative femur were transformed to fit the preoperative femur model. A precise stem model constructed using computer-assisted design data was matched to the transformed rough stem model using the iterative closest point algorithm. We obtained a patient-specific model with the proximal bone geometry, allocation of BMD and stem alignment. We estimated the average of axial and rotational micromotion (MM) at stem-bone interface and the ratio of area (MM � 40 micrometers) on the porous surface in order to analyze primary stability of TW stem with several lengths (standard (100 %), 75 %, 50 %, 40 % and 30 % length).


The Bone & Joint Journal
Vol. 98-B, Issue 3 | Pages 349 - 358
1 Mar 2016
Akiyama K Nakata K Kitada M Yamamura M Ohori T Owaki H Fuji T

Aims

We investigated changes in the axial alignment of the ipsilateral hip and knee after total hip arthroplasty (THA).

Patients and Methods

We reviewed 152 patients undergoing primary THA (163 hips; 22 hips in men, 141 hips in women) without a pre-operative flexion contracture. The mean age was 64 years (30 to 88). The diagnosis was osteoarthritis (OA) in 151 hips (primary in 18 hips, and secondary to dysplasia in 133) and non-OA in 12 hips. A posterolateral approach with repair of the external rotators was used in 134 hips and an anterior approach in 29 hips. We measured changes in leg length and offset on radiographs, and femoral anteversion, internal rotation of the hip and lateral patellar tilt on CT scans, pre- and post-operatively.


The Bone & Joint Journal
Vol. 98-B, Issue 1 | Pages 117 - 124
1 Jan 2016
Takenaka S Hosono N Mukai Y Tateishi K Fuji T

Aims

The aim of this study was to determine whether chilled irrigation saline decreases the incidence of clinical upper limb palsy (ULP; a reduction of one grade or more on manual muscle testing; MMT), based on the idea that ULP results from thermal damage to the nerve roots by heat generated by friction during bone drilling.

Methods

Irrigation saline for drilling was used at room temperature (RT, 25.6°C) in open-door laminoplasty in 400 patients (RT group) and chilled to a mean temperature of 12.1°C during operations for 400 patients (low-temperature (LT) group). We assessed deltoid, biceps, and triceps brachii muscle strength by MMT. ULP occurring within two days post-operatively was categorised as early-onset palsy.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 453 - 453
1 Dec 2013
Nishikawa M Owaki H Fuji T
Full Access

[Objective]

The objectives of this study are to measure the morphometric parameters of pre-operative distal femur in Japanese patients who received TKA, to investigate the differences in distal femoral anatomy between the genders, and to compare the measurements with the dimensions of femoral implants current used in Japan.

[Methods]

One-hundred seventy-nine Japanese patients who underwent TKA in Osaka Koseinenkin Hospital from April, 2009 to December, 2011 were included in this study. The genders and diagnoses were 25/ 154 patients (male/ female) and 143/ 36 patients [osteoarthritis (OA)/ rheumatoid arthritis (RA)], respectively. The mean age, height and body weight were 73.2 years, 152.2 cm and 56.7 kg, respectively. We measured the AP length, ML width, aspect ratio angle of distal femur. The measurement points on the medial condyle was 10 mm and on the lateral condyle was 8 mm from the lowest points of the medial and lateral posterior condyle to stimulate the optimal cutting thickness. We evaluated the relationship between AP length and ML width, or aspect ratio and ML width in diagnosis, alignment and gender. We also compared the measurements with the dimensions of femoral implants current used in Japan.

Continuous variables were assessed using the Mann-Whitney's U test. Relationship between AP length and ML width, or aspect ratio and ML width were assessed using simple regression analysis. Regression lines were assessed using analysis of covariance. For all tests, probability values (p values) of < 0.05 were considered to indicate statistical significance.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 448 - 448
1 Dec 2013
Nakata K Kitada M Akiyama K Owaki H Fuji T
Full Access

[Introduction]

Short tapered wedge-shaped cementless (TW) stems have been widely used for several years. The concept of fixation of TW stem is wedge-fit fixation in the proximal metaphysis. Developmental dysplasia of the hip (DDH) has anatomical abnormality, such as excessive femoral anteversion, short femoral neck length, narrow femoral cavity, or proximal-distal mismatching of the femoral canal. Therefore, Mismatching between stem and bone might be occurred in DDH. We evaluated intramedullary matching of short TW stem for DDH by three dimensional (3D) digital template in order to clarify whether mismatching between stem and bone is seen in DDH implanted short TW stem.

[Materials and Methods]

One hundred hips (92 patients) with DDH were performed preoperative simulation for total hip arthroplasty by 3D digital template system (ZedHip: Lexi, Tokyo, Japan). The average age was 63.5 years old. There were 12 males and 80 females. The average bone mass index was 21.5 kg/m2. Femoral canal shape was normal in 71, champagne-flute in 16 and stovepipe in 13 hips. Bone quality was classified into type A in 23, type B in 74 and type C in 3 hips. Preoperative computed tomography data were used for 3D digital template and reconstructed to 3D femoral model. Short TW stem (Taperloc Complete Microplasty: Biomet, Warsaw, IN) model constructed from computer-assisted design was matched to the reconstructed femoral model. Short TW stem model was in principle implanted according to the femoral neck anteversion with neutral alignment (varus and valgus < 2 degrees, flexion and extension < 2 degrees) at the coronal and sagittal plane of the femur. Stem size was determined in order to obtain the largest intramedullary matching at the coronal plane. Area of stem fitting with the cortical bone was investigated at 10 mm intervals above and below of mid minor trochanter. Intramedullary matching pattern was classified into proximal mediolateral metaphyseal fit, proximal flare fit and diaphyseal fit at multiple reconstructed planes of the 3D femoral model according to stem fitting area.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1541 - 1544
1 Nov 2009
Hosono N Miwa T Mukai Y Takenaka S Makino T Fuji T

Using the transverse processes of fresh porcine lumbar spines as an experimental model we evaluated the heat generated by a rotating burr of a high-speed drill in cutting the bone. The temperature at the drilled site reached 174°C with a diamond burr and 77°C with a steel burr. With water irrigation at a flow rate of 540 ml/hr an effective reduction in the temperature was achieved whereas irrigation with water at 180 ml/hr was much less effective. There was a significant negative correlation between the thickness of the residual bone and the temperature measured at its undersurface adjacent to the drilling site (p < 0.001).

Our data suggest that tissues neighbouring the drilled bone, especially nerve roots, can be damaged by the heat generated from the tip of a high-speed drill. Nerve-root palsy, one of the most common complications of cervical spinal surgery, may be caused by thermal damage to nerve roots arising in this manner.


The Journal of Bone & Joint Surgery British Volume
Vol. 89-B, Issue 11 | Pages 1478 - 1481
1 Nov 2007
Aono H Ohwada T Kaneko N Fuji T Iwasaki M

Inflammatory markers such as the C-reactive protein (CRP), white blood cell count and body temperature are easy to measure and are used as indicators of infection. The way in which they change in the early post-operative period after instrumented spinal surgery has not been reported in any depth.

We measured these markers pre-operatively and at one, four, seven and 14 days postoperatively in 143 patients who had undergone an instrumented posterior lumbar interbody fusion.

The CRP proved to be the only sensitive marker and had returned to its normal level in 48% of patients after 14 days. The CRP on day 7 was never higher than that on day 4. Age, gender, body temperature, operating time and blood loss were not related to the CRP level. A high CRP does not in itself suggest infection, but any increase after four days may presage infection.


The Journal of Bone & Joint Surgery British Volume
Vol. 69-B, Issue 2 | Pages 215 - 219
1 Mar 1987
Ono K Ebara S Fuji T Yonenobu K Fujiwara K Yamashita K

A characteristic dysfunction of the hand has been observed in various cervical spinal disorders when there is involvement of the spinal cord. There is loss of power of adduction and extension of the ulnar two or three fingers and an inability to grip and release rapidly with these fingers. These changes have been termed "myelopathy hand" and appear to be due to pyramidal tract involvement. The characteristic nature of the signs permit the distinction between myelopathy and changes due to nerve root or peripheral nerve disorder. The clinical significance of these signs has been assessed against other tests and their value in management is discussed.