header advert
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 54 - 54
1 May 2021
Debuka E Wilson G Philpott M Thorpe P Narayan B
Full Access

Introduction

IM (Intra Medullary) nail fixation is the standard treatment for diaphyseal femur fractures and also for certain types of proximal and distal femur fractures. Despite the advances in the tribology for the same, cases of failed IM nail fixation continue to be encountered routinely in clinical practice. Common causes are poor alignment or reduction, insufficient fixation and eventual implant fatigue and failure. This study was devised to study such patients presenting to our practice and develop a predictive model for eventual failure.

Materials and Methods

57 patients who presented with failure of IM nail fixation (± infection) between Jan 2011 – Jun 2020 were included in the study and hospital records and imaging reviewed. Those fixed with any other kinds of metalwork were excluded. Classification for failure of IM nails – Type 1: Failure with loss of contact of lag screw threads in the head due to backing out and then rotational instability, Type 2A: Failure of the nail at the nail and lag screw junction, Type 2B: Failure of the screws at the nail lag screw junction, Type 3: Loosening at the distal locking sites with or without infection. X-rays reviewed and causes/site of failure noted.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 15 - 15
1 May 2021
Debuka E Peterson N Fischer B Birkenhead P Narayan B Giotakis N Thorpe P Graham S
Full Access

Introduction

Methoxyflurane can cause hepatotoxicity and nephrotoxicity at anaesthetic doses but has excellent analgesic properties and no nephrotoxic effects in patients without preexisting disease. Approved for use in the UK and Ireland in 2015, it is currently being used in emergency departments for analgesia during fracture reduction. During the Covid emergency, with theatre access severely restricted and many patients unwilling to use inhaled Nitrous oxide, Penthrox had the potential to provide adequate pain relief to aid frame removals and minor procedures in the clinic.

Materials and Methods

Patients presenting to the Limb Reconstruction Unit Elective clinic and requiring frame removal or minor procedures were included in the study. Patients with renal, cardiac or hepatic disease, history of sensitivity to fluorinated anaesthetic agents and those on any nephrotoxic or enzyme inducing drugs were excluded. Verbal consent was obtained, the risks and benefits explained and the procedure was done in a side room in the clinic. Besides patient and procedure details, the Visual Analog Score and Richmond Agitation Scale was noted and patient's satisfaction documented. The results were presented as numbers, means and averages.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_4 | Pages 5 - 5
1 Mar 2021
Kumar G Debuka E
Full Access

Increasing incidence of osteoporosis, obesity and an aging population have led to an increase in low energy hip fractures in the elderly. Perceived lower blood loss and lower surgical time, media coverage of minimal invasive surgery and patient expectations unsurprisingly have led to a trend towards intramedullary devices for fixation of extracapsular hip fractures. This is contrary to the Cochrane review of random controlled trials of intramedullary vs extramedullary implants which continues recommends the use of a sliding hip screw (SHS) over other devices. Furthermore, despite published literature of minimally invasive surgery (MIS) of SHS citing benefits such as reduced soft tissue trauma, smaller scar, faster recovery, reduced blood loss, reduced analgesia needs; the uptake of these approaches has been poor. We describe a novel technique one which remains minimally invasive, that not only has a simple learning curve but easily reproducible results. All patients who underwent MIS SHS fixation of extracapsular fractures were included in this study. Technique is shown in Figure 1. We collated data on all intertrochanteric hip fractures that were treated by a single surgeon series during period Jan 2014 to July 2015. Data was collected from electronic patient records and radiographs from Picture Archiving and Communication System (PACS). Surgical time, fluoroscopy time, blood loss, surgical incision length, post-operative transfusion, Tip Apex Distance (TAD) were analyzed. There were 10 patients in this study. All fractures were Orthopaedic Trauma Association (OTA) type A1 or A2. Median surgical time was 36 minutes (25–54). Mean fluoroscopy time was similar to standard incision sliding hip screw fixation. Blood loss estimation with MIS SHS can be undertaken safely and expeditiously for extracapsular hip fractures.