Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 30 - 30
1 Feb 2021
Cubillos P Fava E Azambuja L Santos VD More ADO De Mello Roesler C
Full Access

Introduction

Total knee and hip arthroplasty were the main arthroplasty surgery performed in Brazil. In Brazil, around 50% of arthroplasty surgeries are performed by the public health system, knowing as SUS 1. SUS is the biggest public and universal health system in the world, attending 100% of the Brazilian population (220 million), with 2020's expected budget of US$ 31 billion 2,3.

The National Institute of Clinical Excellence utilizes the QALY system (Quality adjustment year life)to calculate the best cost-benefit between medical interventions 4. In compliance with the study, an operated person has a QALY index of £5000 while a non-operated person has an index of £7182.

In March 2020, due to the COVID-19 pandemics, the Brazilian Health Ministry oriented for the postponing of elective surgery, to prioritize combating the virus 5. This postponing, it was important but will cause an impact in the economy at the public health system from Brazil this year and in the next years. Therefore, this study aims to present the economic impact caused by COVID-19 pandemics in the public heal system, SUS, of Brazil.

Methods

Data about total hip arthroplasty (THA) and total knee arthroplasty (TKA) in Brazil were collected from the TABNET portal of the Brazilian Health Ministry/Datasus 6. It was collected information per month about hospitalization authorization (AIH), and total cost per AIH. The information regards the period of January to June from years 2015 to 2020.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 37 - 37
1 Feb 2021
De Mello Gindri I Da Silva L More ADO Salmoria G De Mello Roesler C
Full Access

Introduction

According to American Joint Replacement Registry, particle mediated osteolysis represents 13 % of the knee revision surgeries performed in the United States. The comprehension of mechanical and wear properties of materials envisioned for TJR is a key step in product development. Furthermore, the maintenance of UHMWPE mechanical properties after material modification is an important aspect of material success. Initial studies conducted by our research group demonstrated that the incorporation of ibuprofen in UHMWPE had a minor impact on UHMWPE physicochemical and mechanical properties. Drug release was also evaluated and resulted in an interesting profile as a material to be used as an anti-inflammatory system. Therefore, the present study investigated the effect of drug release on the mechanical and biological properties of ibuprofen-loaded UHMWPE.

Experimental

UHMWPE resin GUR 1020 from Ticona was for sample preparation. Samples with drug concentrations of 3% and 5% wt were consolidated as well as samples without anti-inflammatory addition through compression molding at 150 °C and 5 MPa for 15 minutes. Mechanical properties were evaluated via the tensile strength experiment (ASTM D638) and dynamic mechanic tests. Wear resistance was measured using the pin on disc (POD) apparatus. Finally, cytotoxicity analysis was conducted based on ISO 10993–5.