header advert
Results 1 - 3 of 3
Results per page:
Bone & Joint Open
Vol. 3, Issue 10 | Pages 786 - 794
12 Oct 2022
Harrison CJ Plummer OR Dawson J Jenkinson C Hunt A Rodrigues JN

Aims

The aim of this study was to develop and evaluate machine-learning-based computerized adaptive tests (CATs) for the Oxford Hip Score (OHS), Oxford Knee Score (OKS), Oxford Shoulder Score (OSS), and the Oxford Elbow Score (OES) and its subscales.

Methods

We developed CAT algorithms for the OHS, OKS, OSS, overall OES, and each of the OES subscales, using responses to the full-length questionnaires and a machine-learning technique called regression tree learning. The algorithms were evaluated through a series of simulation studies, in which they aimed to predict respondents’ full-length questionnaire scores from only a selection of their item responses. In each case, the total number of items used by the CAT algorithm was recorded and CAT scores were compared to full-length questionnaire scores by mean, SD, score distribution plots, Pearson’s correlation coefficient, intraclass correlation (ICC), and the Bland-Altman method. Differences between CAT scores and full-length questionnaire scores were contextualized through comparison to the instruments’ minimal clinically important difference (MCID).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 178 - 178
1 Sep 2012
Sinclair S Konz G Dawson J Bloebaum R
Full Access

Background

Synthetic interbody spinal fusion devices are used to restore and maintain disc height and ensure proper vertebral alignment. These devices are often filled with autograft bone to facilitate bone bridging through the device while providing mechanical stability. Nonporous polyetheretherketone (PEEK) devices are widely used clinically for such procedures.1Trabecular Metal devices are an alternative, fabricated from porous tantalum. It was hypothesized that the porous Trabecular Metal device would better maintain autograft viability through the center of the device, the ‘graft hole’ (GH).

Methods

Twenty-five goats underwent anterior cervical discectomy and fusion using a Trabecular Metal or PEEK device for 6, 12 or 26 weeks. The GH of each device was filled with autograft bone morsels harvested from the animal at implantation. Fluorochrome labeling oxytetracycline was administered to the animals and used to determine bone viability in the device regions. Following necropsy, the vertebral segments were embedded in poly(methyl methacrylate) sectioned and analyzed using fluorescence and backscatter electron (BSE) imaging. The percent of bone tissue present within the GH was measured as a volume percent using BSE images (Fig. 1).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 204 - 204
1 Sep 2012
Smith J Dawson J Aarvold A Jones A Ridgway J Curran S Dunlop D Oreffo R
Full Access

Background

Replacing bone lost as a consequence of trauma or disease is a major challenge in the treatment of musculoskeletal disorders. Tissue engineering strategies seek to harness the potential of stem cells to regenerate lost or damaged tissue. Bone marrow aspirate (BMA) provides a promising autologous source of skeletal stem cells (SSCs) however, previous studies have demonstrated that the concentration of SSCs required for robust tissue regeneration is below levels present in iliac crest BMA, emphasising the need for cell enrichment strategies prior to clinical application.

Aims

To develop a novel strategy to enrich skeletal stem cells (SSCs) from human BMA, clinically applicable for intra-operative orthopaedic use.