header advert
Results 1 - 1 of 1
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 61 - 61
1 Apr 2017
Antón-Rodrigálvarez LM Flores JB Cabanes L Barrios C Hevia E de Blas G García V
Full Access

Background

The overall incidence of neurological symptoms attributed to lumbar misplaced screws has been described to occur in 3.48% of patients undergoing surgery. These lumbar radicular neurological lesions are undetected with conventional intraoperative neurophysiological and radiological controls. The hypothesis of this study was that direct stimulation of the pedicle screw after placement in the lumbar spine may not work as well as for screws placed in the thoracic pedicles. A more suitable method for the lumbar spine could be the stimulation of the pedicle track with a ball-tipped probe.

Methods

Comparative observational study on the detection of malpostioned lumbar pedicle screws using two different techniques in two different periods: t-EMG screw stimulation (2011–2012) and track stimulation (2013–2014). A total of 1440 lumbar pedicle screws were placed in 242 patients undergoing surgery for vertebral deformities in the last four years (2011–2014). In the first two years, 802 lumbar screws were neuromonitored using t-EMG during. In the last two years, 638 screws were placed after probe stimulation of the pedicle track. Standardised t-EMG conventional registration and fluoroscopy were afterwards performed in all cases.