header advert
Results 1 - 4 of 4
Results per page:
Applied filters
Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_21 | Pages 29 - 29
1 Apr 2013
Rose B Bowman N Edwards H Skyrme A
Full Access

Introduction

Hallux valgus surgical correction has a variable but significant risk of recurrence. Symptoms result from an iatrogenic first brachymetatarsia following the index surgical procedure. First metatarsal shortening has been shown to correlate with the onset of transfer metatarsalgia. We describe the use of the scarf osteotomy to both correct the recurrent deformity and lengthen the shortened first metatarsal.

Methods

36 lengthening scarf osteotomies were undertaken in 31 patients. Clinical (AOFAS and SF12 scores) and radiographic measures (IMA, HVA) were taken pre- and post-operatively. The maximum theoretical lengthening was 10mm, to prevent first MTP joint stiffness post-operatively. The actual lengthening was determined and measured intra-operatively.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 463 - 463
1 Sep 2009
Dakhil-Jerew F Haleem S Jadeja H Bowman N Shah D Cohen A El-Metwally A Guy R Selmon G Shepperd J
Full Access

Introduction: In this study, we report interobserver reliability of X-ray for the interpretation of pedicle screw osteointegration based on the diagnosis of “Halo zone” surrounding the screw.

Dynamic stabilisation system for the spine relies on titanium screw purchase within the pedicle. Decision on osteointegration is important especially when the patient becomes symptomatic following initial good outcome. From our cohort of 420 Dynesys patients, over all incidence of screw loosening was 17%. Only 35% were symptomatic.

Method: Lumbar spine X-ray images of 50 patients in two views (AP and lateral) randomly selected from our cohort of 420 Dynesys patients. The images were deployed in a CD-ROM. The authors were asked to review the images and state whether or not each pedicle screw is loose (total of 258 pedicle screws).

Seven observers composed of two expert orthopaedic spine consultant surgeons and one spine expert consultant radiologist and four Specialist Registrars in orthopaedics and radiology.

Data gathered were distributed and presented in tables in the form of descriptive statistics. The evaluation of interobserver agreement was performed by obtaining a Kappa (K) index. For continuous variables comparison, the t test was employed, with a significance level of 0.05.

Results: Kappa Index among three experts was 0.2198 at 95% CI (−0.0520, 0.4916) while for all 7 assessors (3 Experts & 4 SpR), KI was 0.1462 at 95% CI (0.0332, 0.2592)

Discussion & Conclusion: Kappa Index among expert assessors was 0.2 which means X-ray is unreliable for the assessment of pedicle screw osteointegration. Validity of X-ray is not applicable as it is unreliable.

We are planning to evaluate a 3D computer reconstruction model based on 2 X-ray views at 45 degree angle to each other which might be sensitive to detect screw loosening.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 476 - 476
1 Sep 2009
Dakhil-Jerew F Jadeja H Bowman N Shah D Cohen A El-Metwally A Guy R Selmon G Shepperd J
Full Access

Introduction: In this study, we report interobserver reliability of X-ray for the interpretation of pedicle screw osteointegration based on the diagnosis of “Halo zone” surrounding the screw.

Dynamic stabilisation system for the spine relies on titanium screw purchase within the pedicle. Decision on osteointegration is important especially when the patient becomes symptomatic following initial good outcome. From our cohort of 420 Dynesys patients, over all incidence of screw loosening was 17%. Only 35% were symptomatic.

Method: Lumbar spine X-ray images of 50 patients in two views (AP and lateral) randomly selected from our cohort of 420 Dynesys patients. The images were deployed in a CD-ROM. The authors were asked to review the images and state whether or not each pedicle screw is loose (total of 258 pedicle screws).

Seven observers composed of two expert orthopaedic spine consultant surgeons and one spine expert consultant radiologist and four Specialist Registrars in orthopaedics and radiology.

Data gathered were distributed and presented in tables in the form of descriptive statistics. The evaluation of interobserver agreement was performed by obtaining a Kappa (K) index. For continuous variables comparison, the t test was employed, with a significance level of 0.05.

Results: Kappa Index among three experts was 0.2198 at 95% CI (−0.0520, 0.4916) while for all 7 assessors (3 Experts & 4 SpR), KI was 0.1462 at 95% CI (0.0332, 0.2592)

Discussion & Conclusion: Kappa Index among expert assessors was 0.2 which means X-ray is unreliable for the assessment of pedicle screw osteointegration. Validity of X-ray is not applicable as it is unreliable.

We are planning to evaluate a 3D computer reconstruction model based on 2 X-ray views at 45 degree angle to each other which might be sensitive to detect screw loosening.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 466 - 467
1 Sep 2009
Yeoh D Goddard R Bowman N Macnamara P Miles K East D Butler-Manuel A
Full Access

The most common indication for knee arthrodesis is pain and instability in an unreconstructable knee following an infected knee arthroplasty. In this study, we compare the use of the Mayday arthrodesis nail (Ortho-dynamics, Christchurch, UK) versus external fixation, Orthofix (Berkshire UK) and Stryker Hoffman II (County Cork, Ireland).

All patients in this study underwent arthrodesis between 1995 and 2006 at Conquest Hospital, Hastings. In group A, 11 patients underwent arthrodesis with a Mayday nail. In all cases, the indications were infected total knee replacements (TKR). Three of these patients previously had failed attempts at arthrodesis with external fixation devices. In group B, seven patients underwent arthrodesis using external fixation. In six patients, the indication was infected TKRs. Results were reviewed retrospectively, with union assessed both clinically and radiologically.

The mean inpatient stay for the Mayday nail group was 23 days (range 8 – 45 days) compared with 76 days (range 34 – 122) for the external fixation group (p< 0.01, CI 95). Ten patients in group A went on to confirmed primary arthrodesis. One patient underwent revision arthrodesis with a Mayday nail and subsequently united. In group B only two patients achieved union. The rate of union was significantly greater in the Mayday nail group than the external fixation group (91% vs 29%, p< 0.01). Of those patients that achieved union, there was no difference in the time to fusion between groups.

Our study supported the existing literature and found that the Mayday nail appeared more effective than monoaxial external fixators for arthrodesis in the management of infected total knee replacements.