header advert
Results 1 - 20 of 22
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_17 | Pages 4 - 4
1 Apr 2013
Sherlock KE Elsayed S Turner W Bagouri M Baha L Boszczyk B McNally D
Full Access

Introduction

Cauda equina syndrome represents the constellation of symptoms and signs resulting from compression of lumbosacral nerve routes. Combined with subjective neurological findings, a reduction in anal tone is an important sign deeming further imaging necessary. Our main objective was to investigate the validity of DRE for assessment of anal tone.

Method

75 doctors completed a questionnaire documenting their grade, speciality and experience in performing DRE. A model anus, using a pressure transducer surrounding an artificial canal, was assembled and calibrated. Participants performed 4 DREs on the model and predicted tone as ‘reduced’ or ‘normal’ (35 and 60 mmHg respectively), followed by a ‘squeeze’ test. 30 healthcare assistants (HCAs) with no training in DRE partook as a control group.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 169 - 169
1 Jan 2013
Quah C Yeoman M Cizinauskas A Cooper K McNally D Boszczyk B
Full Access

Background

Spondylolysis (SL) of the lower lumbar spine is frequently associated with spina bifida occulta (SBO). There has not been any study that has demonstrated biomechanical or genetic predispositions to explain the coexistence of these two pathologies.

Purpose

To test the hypothesis that fatigue failure limits will be exceeded in the case of a bifid arch, but not in the intact case, when the segment is subjected to complex loading corresponding to normal sporting activities.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVI | Pages 51 - 51
1 Jun 2012
Thambiraj S Boszczyk B
Full Access

Introduction/Aim

Numerous lumbo-pelvic reconstruction methods based on posterior construct and anterior cages have been proposed for cases involving total sacrectomy and lumbar vertebrectomy. These constructs create long lever arms and generate high cantilever forces across the lumbo-sacral junction resulting in implant failure or breakage. Biomechanical studies have shown that placing implants anterior to lumbo-sacral pivot point provide a more effective moment arm to resist flexion force and improve the ultimate strength of the construct. As a result more emphasis is placed on screws in the pelvis.

We report a new and novel technique that allows for the placement of a pelvic ring construct to augment the posterior construct in a lumbo-pelvic reconstruction.

Method

In the prone position, two contoured hard rods are passed along the inner table of the pelvis under the iliac muscle from a minor posterior approach. The rods are connected to the posterior lumbo-pelvic construct with T-junction clamps. The patient is turned supine and the anterior ends of the rods are connected to a sub-cutaneously placed hard rod along the anterior abdominal wall with T-junction clamps. This in turn is fixed to the AIIS (anterior inferior iliac spine) with two poly axial screws. The whole construct resembles an oblong ring.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVI | Pages 48 - 48
1 Jun 2012
Thambiraj S Boszczyk B
Full Access

Introduction/Aim

In rigid Sagittal and Coronal deformities of the spine Pedicle Subtraction Osteotomies (PSO) is preferred to achieve maximal correction. We describe successful Asymmetrical Pedicle Subtraction Osteotomies (APSO) performed on patients with symptomatic coronal imbalance.

Methods/Results

Case 1: 28yr old female with VATER syndrome with 25° coronal imbalance to her left with past h/o fusion from L3 – S1 for L5 hemi-vertebra. After APSO at L3 coronal imbalance was reduced to 0°.

Case 2: 49yr old male with post-traumatic coronal deformity of 35° at T6 and paraplegia affecting his sitting balance and respiratory function. Following APSO at T12 imbalance was reduced to 5°.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVI | Pages 9 - 9
1 Jun 2012
Balamurali G Konig M Boszczyk B
Full Access

Aim

A retrospective review of the management of giant thoracic discs and report of their outcomes.

Method

Giant thoracic disc have been defined as disc compressing more than 60% of the canal diameter. Although discectomy may lead to improvement of clinical symptoms it can be complicated by approach related morbidity especially when discs are calcified. Between 2007 and 2010 there were a total of 7 patients treated with a giant thoracic disc. A retrospective review of demographic data, symptoms, details of surgery, pre and post operative radiology, pre and postoperative Nurick scores, ODI and pain score, length of stay, complications and follow-up data were collected in all patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVI | Pages 83 - 83
1 Jun 2012
Balamurali G Konig M Boszczyk B
Full Access

Aim

A retrospective review of the management of adjacent level discectomy and fusion using a Zero-P (Synthes) cage and report of ease of technique and outcomes.

Method

Surgical approach to adjacent level cervical disc protrusion with previous anterior cervical discectomy and fusion (ACDF) can be difficult. We review 4 patients who had previous ACDF with cage and plate who developed new onset adjacent level cervical disc prolepses causing myelopathy. A retrospective review of demographic data, symptoms, details of surgery, pre and post operative radiology, pre and postoperative ODI and pain score, length of stay, complications and follow-up data were collected in all patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 32 - 32
1 Apr 2012
Jehan S Bierschneider M Schmid K Grillhösl A Kleinschmidt M Jaksche H Boszczyk B
Full Access

A prospective study was performed to evaluate the efficacy and safety of percutaneous kyphoplasty in patients with osteolytic tumours of thoracic and lumbar spine. To our knowledge this is the only study so far that has followed a cohort of patients prospectively until death.

Prospective study of patients with lytic tumours of spine treated with kyphoplasty.

A total of 13 patients with osteolytic tumours of spine were treated with kyhpoplasty. There were 8 female and 5 male patients. The age range was 52-81 years with average age of 65 years. A total of 25 vertebrae, from T2 to L3, were treated. The types of tumours included; non-Hodgkin lymphoma (2), myeloma (2), gastric-carcinoma (1), cervix-carcinoma (1), breast-carcinoma (3), prostate-carcinoma (2), small cell lung-carcinoma (1), bladder-carcinoma (1).

Outcome was assessed prospectively by visual analogue scale (VAS) for pain, ECOG performance status, walking distance, standing and sitting time.

The preoperative average VAS was 7.5 (range: 2.6 – 10). This dropped to 3.0 five days postoperatively and remained below 5 for the duration of follow-up. Average walking distance, standing and sitting time and ECOG performance score showed improvement. The survival time ranged from 2 to 293 weeks. The average survival time was 82 weeks. All patients were able to return home following the procedure. No patient required reoperation or readmission for spinal metastasis.

Kyphoplasty is a suitable palliative treatment option for patients with advanced metastatic disease of the spine.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 139 - 139
1 Apr 2012
Pal D Bayley E Magaji S Boszczyk B
Full Access

Different methods of lateral mass(LM) screw placement in the cervical spine have been described. In the axial plane, 30 degrees is the recommended angle to avoid neurovascular injury. The estimation of this angle remains arbitrary and operator dependant.

To assess how accurately the lateral trajectory angle (LTA) for cervical LM screws is achieved by visual estimation amongst experienced spinal surgeons.

A sawbone model of cervical spine with simulated lordosis was used. Five spinal consultants and five senior spinal fellows were asked to insert 1.6 mm K wires into lateral masses of C3 to C6 bilaterally to simulate screws. The LTA in transverse plane was measured using a customised protractor. Basic statistical analyses of all the data were obtained. Using all the angles derived, a virtual screw trajectory was drawn in the lateral plane, on a normal axial Computerised Tomography scan of cervical spine of an anonymous patient using PACS system.

The overall mean LTA for the group was 25.15 degrees, that of the fellows 24.4 and consultants 26.2 degrees. Mean deviation from 30 degrees for fellows was 5.2 and 6.4 degrees for consultants. Overall standard deviation was 4.78, for fellows and consultants it was 3.3 and 5.8 respectively. Two episodes of vertebral artery injury occurred at 15 and 16 degrees with simulated angles on CT.

A moderate variability in visual estimation of the trajectory angle exists even amongst experienced surgeons during insertion of cervical LM screws. An anatomical landmark would be useful to improve the reliability of the procedure.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 53 - 53
1 Apr 2012
Elsayed S Jehan S Lakshmanan P Boszczyk B
Full Access

Competency levels of AOSpine members (Europe) based on whether or not they had undertaken a full 12 month fellowship in spinal surgery

Self-assessment questionnaire distributed to members (60 questions relating to: previous surgical training, fellowships and their nature, and both theoretical and practical competency amongst basic and advanced spinal conditions)

289 completed responses

Competency levels with(out) fellowship; differences in fellowship training; overall competence in spinal surgery as neurosurgeons versus those trained as orthopaedic surgeons. Competency defined as those able to deal with complications or able to perform without supervision.

28% (n=80) undertook a full 12 month fellowship

Notable differences between groups were identified (fellowship vs no fellowship): spinal deformity (58% vs 26%), cervical trauma (83% vs 59%), cervical stabilisation (78% vs 53%), lumbar and thoracic trauma (85% vs 57%) and anterior surgery (66% vs 41%) and its complications (46% vs 23%).

Interestingly of the whole group only 43% were competent in the actual practice of conservative management of spinal conditions.

There was no significant difference in theoretical knowledge or practical skills between orthopaedics surgeons and neurosurgeons.

Fellowship training is effective, but there are deficiencies in areas. In order to provide a routine and emergency service as a spinal surgeon, competency at relatively common procedures must be reached. Our data demonstrates a lack of uniformity in such competencies, and we believe efforts towards a formal curriculum for spinal training should be embarked upon.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 15 - 15
1 Apr 2012
Clamp J Bayley E Boszczyk B
Full Access

Consecutive case series

To evaluate the efficacy of a strict stepwise radioanatomical procedure protocol in avoiding neurological complications through tool malplacement in fluoroscopy guided percutaneous procedures of the thoracic spine.

Fluoroscopy guided percutaneous access to thoracic vertebral bodies is technically demanding. There is a trend towards computed tomography (CT) guidance on grounds of perceived lesser risk of spinal canal instrument malplacement. CT is however not always readily accessible and a safe technique for fluoroscopy guided procedures therefore desirable.

350 consecutive fluoroscopy guided percutaneous procedures (biopsy, vertebroplasty or kyphoplasty) covering all thoracic vertebral levels T1-T12 were performed according to a strict stepwise radioanatomical protocol. The crucial step of the protocol was not to advance the tool beyond the anterior-posterior (ap) projection of the medial pedicle wall until the tip of the instrument had been verified to have reached the posterior vertebral cortex in the lateral projection. The neurological status of patients was assessed through clinical examination prior to, immediately after the procedure and before discharge.

Percutaneous instrument placement in the targeted thoracic vertebral body was achieved in all cases and the stepwise radioanatomical protocol was followed in all cases. There was no case of neurological deterioration in the case series.

Conclusion: Attention to radiographic landmarks, specifically not crossing the ap projection of the medial pedicle cortex prior to reaching the posterior vertebral wall in the lateral projection, allows neurologically safe performance of fluoroscopy guided percutaneous procedures of the thoracic spine. This simple protocol is particularly useful when access to CT is limited.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 121 - 121
1 Apr 2012
Jehan S Thambiraj S Sundaram R Boszczyk B
Full Access

Literature review about the current management strategies for U-shape sacral fractures

A thorough literature search was carried out to find out the current concepts in the management of U-shaped sacral fractures.

Meta-analysis of 30 cases of U-Shaped sacral fractures

Radiological assessment for bone healing, and clinical examination for neurological recovery.

7 papers were published in the English literature between 2001 and 2009 about the management of U-shaped sacral fractures. In total 30 cases were included. The most common mechanism of injury was fall or jump from height (63%), followed by road traffic accidents and industrial injuries. Pre-operative neurological deficit was noted in 73% of patients. The average follow up time ranged from 2-12 months.

18 (60%) of patients were treated with sacroiliac screws. In this group pre-operative neurological deficit was found in 12(66%) patients. All of these patients had satisfactory radiological healing at follow up but 5(27%) patients had residual neurological deficit. No immediate complication was reported in this group. Incomplete sacroiliac screw disengagement was reported in one patient without fixation failure. Other procedures performed were lumbopelvic fixation, triangular osteosynthesis and transsacral plating.

The most common cause of U-shaped sacral fractures is a fall or jump from height. There is a high association of neurological damage with U-shaped sacral fractures. From the current available evidence sacroiliac screw fixation is the most commonly performed procedure, it is however not possible to deduce which procedure is better in terms of neurological recovery.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 73 - 73
1 Apr 2012
Sundaram R Saville P Jehan S Boszczyk B
Full Access

To determine if there is a safe osseous corridor for trans-sacroiliac screw fixation of U-type sacral fractures using fluoroscopic landmarks.

We reviewed the sacral anatomy of patients who underwent Computed Tomography (CT) investigations between October and December 2009. Agfa-IPMAX Version 5.2 software was used to determine if there was a trans-sacroiliac osseous corridor in the S1 and S2 vertebrae from one ilium to the other.

76 patients were in the study, 38 male and 38 female. Exclusion criteria were patients under 18 years old; patients with degenerate lumbar spine and lumbo-sacral junction; CT imaging slices greater than 2.5mm.

We measured various parameters including the dimensions of the S1 and S2 mid-sagittal vertebral body; cross-sectional areas of the S1 and S2 corridor; location of the centre of the S1 and S2 corridor.

The mean cross-sectional area for S1 and S2 corridors in males and females are 21mm2 and 15mm2 respectively. The mean cross-sectional area for the S2 corridor in males and females were 15mm2 and 11mm2 respectively. The centre of the S1 and S2 corridor is located in the centre of both S1 and S2 vertebrae.

Two-thirds of males and females have a complete osseous corridor to pass a trans-sacroiliac S1 screw. The S2 corridor was present in all males but only in 87% of females. Before placement of trans-sacroiliac screws, the surgeon should review the CT sacral anatomy to determine if the trans-sacroiliac osseous corridor is present.

Ethics Approval: None – Audit Interest Statement: None


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 21 - 21
1 Apr 2012
Boszczyk B
Full Access

To analyse procedural details - specifically vertebral levels treated and injected polymethylmethacrylate (PMMA) volumes - of the publications by Buchbinder et al. 1 and Kallmes et al. 2 in the context of best available basic science.

Review

Two randomised controlled trials published by the New England Journal of Medicine (NEJM) in 2009 comparing vertebroplasty to sham procedures conclude vertebroplasty to be no more effective than injection of local anaesthetic. This finding contradicts previous publications showing clinical efficacy.

Neither investigation provides a breakdown of vertebral levels treated (original publication and supplementary material). Only one investigation provides information on fill volumes with average of 2.8 ml +/− 1.2 ml SD.

The available basic science indicates a minimum fill volume of 13-16% of the vertebral body volume to be necessary for a relevant biomechanical effect on restoration of vertebral strength, according to which only vertebrae of the upper to mid thoracic spine could reasonably have received a biomechanically effective fill with the declared average volume of 2.8 ml +/− 1.2 ml SD.

The available data of the NEJM publications strongly indicates that the treatment arm includes insufficiently treated patients. The technical information provided by the NEJM publications is insufficient to conclusively prove or disprove the clinical efficacy of vertebroplasty.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 56 - 56
1 Apr 2012
Lakshmanan P Dvorak V Schratt W Thambiraj S Collins I Boszczyk B
Full Access

The footplate in the current available TDR is flat without any allowance for endplate concavity in the sagittal plane.

To assess the morphology of the endplates of the lower lumbosacral in the sagittal plane, and to identify the frequently occurring shape patterns of the end plates at each level.

Retrospective Study

200 consecutive magnetic reasonance imaging (MRI) scans of patients between the age of 30 and 60 years were analysed. In each endplate, the anteroposterior width, the height of concavity of the endplate, and the distance of the summit from the anterior vertebral body margin were noted. The shape of the endplate was noted as oblong (o) if the curve was uniform starting from the anterior margin and finishing at the posterior margin, eccentric (e) if the curve started after a flat portion at the anterior border and then curving backwards, and flat (f) if there is no curve in the sagittal plane.

The shape of the end plate is mostly oblong at L3 IEP(59%), equally distributed between oblong and eccentric at L4 SEP (o=43.5%, e=46.5%), eccentric at L4 IEP (e=62.5%), eccentric at L5 SEP (e = 59.0%), eccentric at L5 IEP (e=94.0%), and flat at S1 SEP (f=82.5%).

As there is a difference in the shape of the endplate at each level and they are not uniform, there is a need to focus on the sagittal shape of the footplate to avoid subsidence and mismatch of the footplate in cases of endplate concavity.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 380 - 380
1 Jul 2010
Bayley E Zia Z Kerslake R Klezl Z Boszczyk B
Full Access

Aim: In sub-axial cervical vertebrae the lamina appears to project perpendicular to the ipsilateral pedicle axis, and forms a reliable trajectory for avoidance of vertebral artery injury in lateral mass (LM) screw placement: the aim is to confirm these observations.

Material and Methods: 51 digital cervical spine CTs (255 vertebrae; 25 female 26 male; mean age 37.4 range:18–80). Exclusions: Severe degeneration, malformation, tumour, trauma.

Measurement (axial view):

Angle of ipsilateral outer lamina cortex to pedicle axis

Virtual screw trajectory 2 mm from and parallel to the lamina was placed through the LM. Potential violation of the transverse foramen and LM width available for screw purchase was assessed

Results: Average lamina-pedicle angle (standard deviation):

Females: Right: C3–84.8°(2.6), C4–85.2°(3.1), C5–86.7°(3.3), C6–89.2°(2.5), C7–92.3°(2.4);

Left: C3–84.0°(3.1), C4–84.5°(3.9), C5–86.6°(3.7), C6–89.6°(2.6), C7–92.1°(2.3)

No significant difference between males and females (P< 0.05)

Violation of transverse foramen C3–C7: 0%

LM width (trajectory parallel to LM) in millimetres (standard deviation):

Males: Right: C3–5.5(0.7), C4–6.1(0.7), C5–6.8(0.8), C6–7.1(1.1), C7–6.1(1);

Left: C3–5.2(0.8), C4–5.9(0.8), C5–7(1.2), C6–7.3(1.1), C7–6.3(1.4)

Females: Right: C3–5.3(0.8), C4–5.5(0.9), C5–6.6(1.2), C6–6.3(1.3), C7–5.4(1.4);

Left: C3–5.2(1), C4–5.7(1), C5–7.1(1.1), C6–6.5(1.3), C7–5.5(1.6)

Conclusion: The angle formed by the lamina and ipsilateral pedicle ranges from 84° at C3 to 92° at C7. Although the angle is not exactly perpendicular at all levels as hypothesised, the lamina forms a useful reference plane for pedicle screw insertion in the sub-axial cervical spine.

LM screws placed parallel to the lamina find sufficient LM width and are highly unlikely to injure the vertebral artery in bi-cortical placement. This technique appears favourable over conventional 30° LM placement.

Ethics approval: None needed

Interest Statement: None


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 382 - 382
1 Jul 2010
Harshavardhana N Hegarty J Freeman B Boszczyk B Dabke H Weston J Race A
Full Access

Purpose: To review the existing practice of coding in spinal surgery and ascertain its accuracy for surgical procedures, co-morbidities and complications.

Methods: A retrospective review of 70 cervical and 100 lumbar consecutive spinal surgeries performed since April 2006 was conducted. The clinical coding data and hospital notes were reviewed.

Results: Coding data of 5 cervical spine surgeries were not available. Of the 165 cases, the accuracy of primary procedural codes was 93.9% (90.8% cervical & 96% lumbar). This reduced to 77.6% (75.4% cervical & 79% lumbar) when the accuracy for entire description of performed surgery was considered. Medical co-morbidities were coded appropriately in 64.2% of the patients (55% cervical & 70% lumbar). The procedural codes did not specifically reflect the surgery performed and lacked reproducibility. Surgical levels were coded incorrectly in 9% of the cases. Cervical surgeries were coded as lumbar in 4 and posterior surgery as anterior in 3 cases respectively. The commonly missed co-morbidities were drug allergies, hypercholesterolemia, smoking and alcoholism. Post-op adverse events were coded in 75% of the cases (16/20 cervical & 5/8 lumbar). The accuracy was better for lumbar as compared to cervical spinal surgeries.

Conclusion: Coding is a universal language of communication and its accuracy is important not just for PbR, but for data quality, audit and research purposes too. The financial implications regarding PbR governed by HRG codes (dictated by OPCS 4.4 & ICD–10 codes) are discussed. Following this study, a clinical coding facilitation form has been introduced to improve data quality.

Ethics approval: None

Interest statement: None


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 236 - 236
1 Mar 2010
Harshavardhana N Hegarty J Weston J Race A Boszczyk B
Full Access

Introduction: Accurate & ethical coding is challenging and directly impacts on Payment by Results (PbR). The objectives were to review the existing pattern of coding for lumbar spinal surgery and ascertain its appropriateness & accuracy for surgical procedures, medical comorbidities and post-op complications.

Methods: A retrospective review of 100 consecutive lumbar spine surgeries operated from Apr2006–Jan2007 was conducted. The coding excel sheet, hospital notes and laboratory reports were reviewed.

Results: The primary procedural accuracy was 96%, however this reduced to 79% for the entire description of performed surgery. The procedural codes did not specifically reflect the surgery performed and lacked reproducibility. Spinal fusion codes were omitted and revision cases were coded as primary surgeries in 2 instances each. Surgical levels were coded incorrectly in 12 and harvest of iliac crest bone graft omitted in 4 cases respectively. Medical comorbidities were coded appropriately in 70%. The commonly missed comorbidities were drug allergies, hypercholesterolemia, smoking and alcoholism. Post-op adverse events were coded in 62.5% of the cases(5/8).

Conclusion: Coding is a universal language of communication amongst healthcare professionals. Its accuracy is important not just for PbR, but also for data quality, audit and research. The financial implications regarding PbR governed by Healthcare Resource Group (HRG) codes (dictated by Official population and census surveys [OPCS4.4] & International classification of diseases [ICD–10] codes) are discussed. The awareness of clinical coding is low amongst junior doctors. Literature emphasises qualification of coders, legible documentation by physicians and interaction between coders & clinicians.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 492 - 492
1 Sep 2009
Littlewood A Tsegayee M Putz R Boszczyk B
Full Access

Introduction: The intricate biomechanical function of the alar ligaments in the craniocervical articular complex has received considerable scientific attention. While allowing the greatest range of axial rotation of the entire spine with 40° to each side, definitive restraint at the extremes of motion by the alar ligaments is of vital importance. Detailed knowledge of the function of these ligaments is essential for comprehending the factors leading to potentially devastating instability.

Methods: Bilateral alar ligaments including the bony entheses were removed from six adult cadavers aged 65–89 years within 48 hours of death. All specimens were judged to be free of abnormalities with the exception of non-specific degenerative changes. Dimensions of the alar ligaments were measured. Schematic multipla-nar reconstruction of axial atlanto-axial rotation was done in the transverse and frontal planes for the neutral position and for rotation to 30° and 40° in the neutral plane to assess schematic fibre elongation during axial rotation and to determine the change in the angle of insertion at the odontoid and condylar entheses. This was repeated with a 1mm descending translation of the occipital condyles at 30° and 3mm descending translation of the occipital condyles at 40° rotation.

Results: The average diameter of the odontoid process measured in the sagittal plane was 10.6 mm (SD 1.1). The longest fibre length was measured from the posterior border of the odontoid enthesis to the posterior border of the condylar enthesis with an average of 13.2 mm (SD 2.5) and the shortest between the lateral (anterior) border odontoid enthesis and the anterior condylar enthesis with an average of 8.2 mm (SD 2.2). Attachment areas of the enthesis revealed an average of 60 mm2 (SD 12.4) for the odontoid and 50,6 mm2 (SD12.6) for the condylar enthesis. Schematic fibre elongation reaches 27,1% for the longest fibres at 40° axial rotation. This is reducible to 7,8% elongation by 3mm caudal translation of the atlas.

Conclusions: This theoretical model confirms that the bi-convex shape of atlanto-axial joint allows for rotation when modelled with oblique alar ligaments. This provides baseline for further research with functional MRI which will be useful for rheumatoid and post traumatic spine.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 486 - 486
1 Sep 2009
Tsegaye M Littlewood A Schmitt N Lindsay K Mooi J Dirocco C Boszczyk B
Full Access

Cervical spine disorders represent a good proportion of the daily practice of many neurosurgeons. The rapidly increasing knowledge base on spinal conditions and the progressive complexity of surgical interventions appear to be generating a renewed interest in this evolving subspecialty among neurosurgical trainees. In order to assess the current level of spinal surgery training and conveyed competence in dealing with spinal disorders, a self assessment questionnaire was devised and distributed to the neurosurgical trainees attending the EANS (European Association of Neurosurgical Society) training courses. 126 questionnaires were returned with a return rate of 32%. The majority of trainees responding to the questionnaire were in their final (6th) year of training or had completed their training (60,3% of total) representing 25 European nations. A separate analysis of the data pertaining to cervical spine disorders revealed 80% of the trainees completing their training in University hospitals with cervical spine injuries predominantly managed by neurosurgeons (75%). In their practical skill assessment, 78% of the senior trainees were competent in the treatment of cervical disc herniation and cervical spinal stenosis in their anterior microsurgical techniques. In emergency management of cervical spinal trauma, 45% of the senior trainees were competent in being able to perform procedures without direct supervision. Regarding skills in anterior and posterior cervical stabilisation techniques, 33% and 15% respectively were competent in performing as well as dealing with complications & difficulties that may arise. Spinal surgery training in European residency programs has clear strength in the traditional areas of microsurgical decompression for spinal stenosis and disc herniation. Deficits are revealed in the management of spinal trauma and spinal conditions requiring the use of implants, with the exception of anterior cervical stabilisation. In order to achieve a high level of competency, EANS trainees advocate the development of a post-residency spine sub-specialty training program.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 497 - 497
1 Sep 2009
Harshavardhana N Shahid R Freeman B Boszczyk B Hegarty Race A Weston J Grevitt M
Full Access

Introduction: Accurate and ethical coding is challenging and directly impacts on Payment by Results (PbR). The aims & objectives of this study were to review the existing pattern of coding for spinal surgery and ascertain its appropriateness & accuracy for surgical procedures, medical co-morbidities and post-op complications.

Methods: A retrospective review of 70 consecutive cervical and 100 consecutive lumbar spine patients who were operated from April 2006 onwards was conducted. The excel sheet provided by coding department, hospital notes – clinic letters, physicians’ entries, theatre notes and laboratory reports (biochemistry/microbiology/histology) – were reviewed. Of the 170 cases, 165 were available for analysis.

Results: Coding data of 5 patients who underwent cervical spine surgeries were not available. Of the 165 cases, the accuracy of primary procedural codes was 93.9% (90.8% cervical & 96% lumbar). However this reduced to 77.6% (75.4% cervical & 79% lumbar) when the accuracy for entire description of performed surgery was considered. The procedural codes did not specifically reflect the surgery performed and lacked reproducibility. Surgical levels were coded incorrectly in 9% of the cases. Cervical surgeries were coded as lumbar in 4 and posterior surgery as anterior in 3 cases respectively. Harvest of iliac crest bone graft was not coded in 5 cases. Medical comorbidities were coded appropriately in 64.2% of the patients (55% cervical & 70% lumbar). The commonly missed comorbidities were drug allergies, hypercholesterolemia, smoking and alcoholism. Post-op adverse events were coded in 75% of the cases (16/20 cervical & 5/8 lumbar). The accuracy was better for lumbar as compared to cervical spinal surgeries.

Conclusion: Coding is a universal language of communication amongst healthcare professionals. Its accuracy is important not just for PbR, but for data quality, audit and research purposes too. The financial implications regarding PbR governed by HRG codes (dictated by OPCS 4.4 & ICD–10 codes) are discussed. The awareness of clinical coding is low amongst junior doctors. Following this study, a clinical coding facilitation form has been introduced to improve data quality. Our plan is to close the audit loop and re-evaluate. Literature emphasises qualification of coders, legible documentation by physicians and interaction between coders and clinicians.