Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 61 - 61
1 Feb 2017
Khan H Riva F Pressacco M Meswania J Panagiotidou A Coathup M Blunn G
Full Access

Background

Complications of metal-on-metal hip resurfacing, leading to implant failure, include femoral notching, neck fracture, and avascular necrosis. Revision arthroplasty options include femoral-only revision with a head, however mis-matching radial clearance could accelerate metal ion release. Alternatively, revision of a well-fixed acetabular component could lead to further bone loss, complicating revision surgery. We have developed a ceramic hip resurfacing system with a titanium-ceramic taper junction; taking advantage of the low frictional torque and wear rates that ceramic affords. Taking a revision scenario into account, the ceramic head has a deep female taper for the resurfacing stem, but also a superficial tapered rim. Should revision to this resurfacing be required, any femoral stem with a 12/14 taper can be implanted, onto which a dual taper adaptor is attached. The outer diameter of the taper adaptor then becomes the male taper for the superficial taper of the ceramic head; ultimately allowing retention of the acetabular component. In an in-vitro model, we have compared the fretting corrosion of this taper adaptor to existing revision taper options: a titanium-cobalt chrome (Ti-CoCr) taper junction, and a titanium-titanium sleeve-ceramic (Ti-Ti-Cer) taper junction.

Methods

To simulate gait, sinusoidal cyclical loads between 300N-2300N, at a frequency of 3Hz was applied to different neck offsets generating different bending moments and torques. Bending moment and frictional torque were tested separately. An electrochemical assessment using potentiostatic tests at an applied potential of 200mV, was used to measure the fretting current (μA) and current amplitude (μA). In a short term 1000 cycle test with bending moment, four neck lengths (short to x-long) were applied. For frictional torque, four increments of increasing torque (2-4-6-8Nm) were applied. In a long-term test using the taper adaptor, the combination of worst-case scenario of bending and torque were applied, and fretting currents measured every million cycles, up to 10 million cycles.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 60 - 60
1 Feb 2017
Khan H Meswania J Riva F Pressacco M Panagiotidou A Coathup M Blunn G
Full Access

Background

Hip resurfacing has advantages for the young active patient with arthritis; maintaining a large range of motion, preserving bone stock, and reduced dislocation risk. However high serum metal ion levels with metal-on-metal resurfacing, and their clinical implications, has led to a decline in the use of hip resurfacing. Ceramic bearing surfaces display the lowest frictional torque and excellent wear rates. Recent developments have enabled large, strong ceramic materials to be used as resurfacing components. Any wear debris that is generated from these articulations is inert. However an all-ceramic hip resurfacing could be at risk of fracture at the head-stem junction. A new ceramic hip resurfacing system with a titanium-ceramic modular taper junction has been developed. The introduction of a taper introduces the potential for fretting corrosion; we sought to determine the extent of this in an in-vitro model, and compared this prosthesis to the conventional 12/14 titanium-cobalt chrome (Ti6Al4V-CoCr) taper junction.

Methods

To simulate the gait cycle, sinusoidal cyclical loads between 300N-2300N, at a frequency of 3Hz, were applied to different head-neck offsets generating different bending moments and torques. The effect of increasing the bending moment and frictional torque were tested separately. Furthermore, the resurfacing head was mounted in a fixture held with just the stem, thus representing complete bone resorption under the head. An electrochemical assessment using potentiostatic tests at an applied potential of 200mV, was used to measure the fretting current (μA) and current amplitude (μA). In a short-term 1000 cycle test, six neck lengths (short to xxx-long) of the Ti6Al4V-CoCr taper were compared to the standard neutral (concentric), and 3mm A/P offset stem options for the resurfacing design. To represent frictional torque, four increments of increasing torque (2-4-6-8Nm) were applied to both tapers. In a long term test with the resurfacing stem, the worst-case scenario of the eccentric offset option and 8Nm of torque were applied, and potentiostatic measurements were taken every million cycles, up to 10 million cycles.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_23 | Pages 59 - 59
1 Dec 2016
Hislop S McKenna D Coathup MJ Blunn G Briggs T
Full Access

Aim

Photodynamic therapy (PDT) requires a photosensitiser, a light source of an appropriate wavelength, and the presence of molecular oxygen. Once stimulated to its excited phase by the light, the photosensitiser reacts with oxygen to form free radicals of ‘singlet oxygen’ which is cytotoxic to microorganisms.

We aim to demonstrate the effectiveness of PDT as an in-vitro antimicrobial technique against Staphylococcus aureus, Methicillin resistant Staphylococcus aureus, Staphylococcus epidermidis, Pseudomonas aeruginosa and Acinetobacter bauminii. This will form the scientific basis for further animal and human studies assessing PDT for treatment of periprosthetic infections, septic arthritis, and open fractures.

Method

A PDT treatment protocol was devised using lawns of bacteria on agar plates. PDT was targeted towards the bacteria and the remaining microorganisms were quantified using a serial dilution technique. In order to assess the ability of photodynamic therapy to target biofilms on metallic implants, biofilms were cultured on polished titanium and hydroxyapatite-coated titanium discs and subjected to PDT.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_9 | Pages 83 - 83
1 May 2016
Christiansen J Nielsen P Laursen M Blunn G
Full Access

Introduction

The Primoris® femoral stem was designed to preserve bone and maintain normal stress to the proximal femur, thereby minimizing stress-shielding. The implant is anchored in the femoral neck and metaphysis without diaphysial involvement and differs from other neck prothesis by: a) Elliptical shape to fit the inner neck dimensions. b) On top of Ti– porous-coating electrochemically deposited hydroxy apatite (Bonemaster®) c) The surgical technique aims to enhance initial implant stability by compaction of neck and metaphyseal cancellous bone.

Objectives

As part of stepwise introduction to monitor bone remodeling, RSA data and clinical results.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 8 - 8
1 May 2016
Adesina T Ajami S Coathup M Blunn G
Full Access

Introduction

Stress shielding and wear induced aseptic loosening cause failure in total joint arthroplasty. To improve long-term outcomes in total knee arthroplasty (TKA), the use of a low modulus, low wearing biomaterial may be a suitable alternative to cobalt chromium (CoCr) femoral components. Based on its favorable mechanical properties and observed clinical success especially in spinal surgery, polyetheretherketone (PEEK) is investigated as a candidate material for a metal free TKA. An all polymer TKA has several theoretical advantages, these include a more physiological stress in the distal femur, elimination of biological reaction to metal, better radiographic visualisation of the bone implant interface especially with CT and MRI. In addition, polymers afford a cheaper option for the manufacture of prostheses.

Aims and Hypothesis

This study investigated the wear performance of PEEK and carbon reinforced PEEK (CFR-PEEK) as bearing materials in an all polymer TKA using a unidirectional pin on plate test. Our hypothesis was that reduced wear is generated from PEEK or CFR-PEEK bearings when compared with metal on polyethylene (MoP) bearings and that this combination may provide a suitable alternative in TKA.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 10 - 10
1 May 2016
Ajami S Coathup M Khoury J Blunn G
Full Access

Background

Polyetheretherketone (PEEK) may be advantageous as an alternative material to metal alloys in some orthopaedic applications. However, it is bioinert and does not osseointegrate1. A novel accelerated neutral atom beam technique (ANAB) has been developed to improve the bioactivity of PEEK where the surface is modified to a depth of 5 nm without affecting the integrity of the underlying PEEK structure2.

Aim

The aim of this study was to investigate the growth of human Mesenchymal Stem Cells (hMSCs), adult human Osteoblasts (hOB) and skin Fibroblasts (BR3G) on PEEK and ANAB treated PEEK.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 474 - 474
1 Dec 2013
Panagiotidou A Meswania J Hua J Muirhead-Allwood SK Skinner JA Hart A Blunn G
Full Access

Introduction:

There has been widespread concern regarding the adverse tissue reactions after metal-on-metal (MoM) total hip replacements (THR). Concerns have also been expressed with mechanical wear from micromotion and fretting corrosion at the head/stem taper junction in total hip replacements. In order to understand the interface mechanism a study was undertaken in order to investigate the effect of surface finish and contact area associated with modular tapers in total hip replacements with a single combination of materials of modular tapers.

Methods:

An inverted hip replacement setup was used (ASTM F1875-98). 28 mm Cobalt Chrome (CoCr) femoral heads were coupled with either full length (standard) or reduced length (mini) 12/14 Titanium (Ti) stem tapers. These Ti stem tapers had either a rough or smooth surface finish whilst all the head tapers had a smooth surface finish. Wear and corrosion of taper surfaces were compared after samples were sinusoidally loaded between 0.1 kN and 3.1 kN for 10 million cycles at 4 Hz. In test 1 rough mini stem tapers were compared with rough standard stem tapers whilst in test 2 rough mini stem tapers were compared with smooth mini stem tapers. Surface parameters and profiles were measured before and after testing. Electrochemical static and dynamic corrosion tests were performed between rough mini stem tapers and smooth mini stem tapers under loaded and non-loaded conditions.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 188 - 188
1 Dec 2013
Vanhegan I Coathup M McCarthy I Haddad F Blunn G
Full Access

Introduction

Revision hip arthroplasty is a technically challenging operation as proximal bony deficits preclude the use of standard implants. Longer distally fixing stems are therefore required to achieve primary stability.

Aims

This work aims to compare the primary stability and biomechanical properties of a new design of tapered fluted modular femoral stem (Redapt®, Smith & Nephew) to that of a conical fluted stem (Restoration®, Stryker). It is hypothesized that the taper will provide improved rotational stability under cyclical loading.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 473 - 473
1 Dec 2013
Panagiotidou A Bolland B Meswania J Skinner J Haddad F Hart A Blunn G
Full Access

Introduction:

High failure rates with large diameter, metal on metal hip replacements have highlighted a potential issue with the head/stem taper junction as one of the significant sources of metal ion release. Postulated reasons as to why this may be such a problem with large head metal on metal hip replacements is due to the increased torque achieved by the larger head size. This may be responsible for applying greater micromotion between the head and stem taper and consequently greater amounts of fretting corrosion. The aim of this study was to perform short term in vitro electrochemical tests to assess the effect of increasing head diameter and torque on the fretting corrosion susceptibility of the head/stem taper interface and to investigate its effect on different material combinations.

Methods:

36 mm Cobalt Chrome (CoCr) femoral heads were coupled with either a CoCr or Titanium (Ti) stem with 12/14 tapers, all with a smooth surface finish. Increasing perpendicular horizontal offsets in the sagittal plane created incremental increases in torque. Offset increments of 0 mm, 5.4 mm and 7.5 mm were selected (Figure 1) to simulate the torque force equivalent to 9 Nm, 12 Nm and 17 Nm. An inverted hip replacement setup was used (ASTM F1875-98) (Figure 2). Components were statically loaded at 0 kN and 2.3 kN prior to sinusoidal cyclic loading and electrochemical testing. Mean & fretting currents were calculated every 50 cycles up to a maximum of 1000 cycles of sinusoidal cyclic loading at 3 Hz along with the Overall Mean Current (OMC), Overall Mean Fretting Current (OMFC) and Overall Current change (OCC).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 77 - 77
1 Dec 2013
Hothi H Berber R Whittaker R Cro S Blunn G Skinner JA Hart A
Full Access

Introduction

It has been suggested that corrosion and fretting at the taper junctions of stemmed metal-on-metal hip replacements may contribute to their high failure rates. A peer-reviewed semi-quantitative scoring system [Goldberg et al., 2002] has been used to visually assess the severity of corrosion and fretting of the taper junction but has not been validated using multiple examiners. The aim of this study was to assess the inter-observer variability of this method.

Method

Macroscopic and stereomicroscopic examinations of the femoral head and stem tapers of 100 retrieved large diameter metal on metal (MOM) hip components were performed by two independent observers using the methods defined by Goldberg et al. [2002] to quantify corrosion and fretting. Scores ranging from 1 (none) to 4 (severe) were assigned to the medial, lateral, posterior and anterior quadrants of the neck taper and the distal and proximal regions of the head taper. An overall score was then assigned to each surface as a whole.

Cohen's weighted Kappa statistic (κ) was used to measure the inter-observer agreement. A quadratic weighting scheme, that allocated weights to the importance of disagreements that are proportional to the square of the number of categories apart, was used to take account of scaled disagreement.

Kappa values were assessed using previously established criteria where κ ≤ 0 = poor, 0.01 to 0.20 = slight, 0.21 to 0.40 = fair, 0.41 to 0.60 = moderate, 0.61 to 0.80 = substantial, 0.81 to 1 = almost perfect.

A sample size of 100 was used in order to detect a coefficient of 0.60 to within 0.25 with 95% confidence with two experienced observers. Statistical analysis was performed using Stata/IC version 12.1 (StataCorp, College Station, TC, USA) and a p value < 0.05 was considered statistically significant.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 170 - 170
1 Jan 2013
Elnikety S Pendegrass C Blunn G
Full Access

Introduction

Tendon injuries remain challenging, secondary healing and prolonged immobilisation result in suboptimal outcome. Previous study by our group showed that demineralised bone matrix (DBM) can result in faster healing of a tendon enthesis. The aim of this study is to test different ways augmenting tendon with DBM to enhance tendon repair and regeneration.

Methods

DBM strips were prepared from tibias of mature ewes. Patella, patellar tendon and tibias were dissected and the distal 1 cm of the patellar tendon was excised.

4 models were designed;

Model-1, DBM strip was used to bridge the gap between the tendon and the tibial tuberosity. The DBM strip was stitched to the tendon using one bone anchor.

Model-2, similar to model 1 with the use of 2 anchors.

Model-3, similar to model 2, construct was off loaded by continuous thread looped twice through bony tunnels sited in the patella and in the tibial tuberosity.

Model-4, similar to model 3 with 3 threads as off loading loop.

All models were tested for pullout force and mode of failure.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 171 - 171
1 Jan 2013
Elnikety S Pendegrass C Blunn G
Full Access

Introduction

Demineralised Bone Matrix (DBM) is widely used in Orthopaedics and dentistry as a bone graft substitute and may be used to augment bone formation in load bearing applications.

In this study we examine the effect of gamma irradiation and freeze drying on the tensile strength of Demineralised Cortical Bone (DCB).

Methods

Tibias were harvested from mature ewes and cut into bony strips. Demineralisation was done using 0.6M HCL and confirmed by X-ray. Specimens were washed until a pH of 7.0 +/_ 0.2 was achieved in the washing solutions.

Specimens were allocated into 4 groups; group (A) non freeze dried non gamma irradiated, group (B) freeze dried non gamma irradiated, group (C) non freeze dried gamma irradiated mention the level of gamma irradiation and group (D) freeze dried and gamma irradiated. The maximum tensile force and stress were measured. Statistical analysis using the Mann-Whitney U test was carried out.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 79 - 79
1 Sep 2012
Vanhegan I Jassim S Sturridge S Ahir S Hua J Witt J Nielsen P Blunn G
Full Access

Introduction

A new conservative hip stem has been designed to address the complex problem of total hip arthroplasty in the younger population.

Objectives

To assess the stability and strain distribution of a new conservative hip stem.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 76 - 76
1 Jun 2012
Gokaraju K Miles J Blunn G Unwin P Pollock R Skinner J Tillman R Jeys L Abudi A Briggs T
Full Access

Non-invasive expandable prostheses for limb salvage tumour surgery were first used in 2002. These implants allow ongoing lengthening of the operated limb to maintain limb-length equality and function while avoiding unnecessary repeat surgeries and the phenomenon of anniversary operations.

A large series of skeletally immature patients have been treated with these implants at the two leading orthopaedic oncology centres in England (Royal National Orthopaedic Hospital, Stanmore, and Royal Orthopaedic Hospital, Birmingham).

An up to date review of these patients has been made, documenting the relevant diagnoses, sites of tumour and types of implant used. 87 patients were assessed, with an age range of 5 to 17 years and follow up range of up to 88 months.

Primary diagnosis was osteosarcoma, followed by Ewing's sarcoma. We implanted distal femoral, proximal femoral, total femoral and proximal tibial prostheses. All implants involving the knee joint used a rotating hinge knee. 6 implants reached maximum length and were revised. 8 implants had issues with lengthening but only 4 of these were identified as being due to failure of the lengthening mechanism and were revised successfully. Deep infection was limited to 5% of patients.

Overall satisfaction was high with the patients avoiding operative lengthening and tolerating the non-invasive lengthenings well. Combined with satisfactory survivorship and functional outcome, we commend its use in the immature population of long bone tumour cases.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 251 - 251
1 Jun 2012
Unwin P Pickford M Shawcross J Blunn G Cannon S Grimer R
Full Access

Infected mega-endoprostheses are difficult to treat with systemic antibiotics due to encapsulation of the implant by fibrous tissue, formation of biofilms and antibiotic resistant bacteria. Modifying the implant surface by incorporating a bactericidal agent may reduce infection. Infection rates are typically in the range of 8% to 30%. This study describes a novel process method of “stitching-in” ionic silver into the implant surface, in vitro testing and its early clinical usage.

A novel process has been developed to “stitch in” ionic silver into the upper surface of titanium alloy (Ti6Al4V). The process produces a modification by anodisation of the titanium alloy in dilute phosphoric acid, followed by absorption of silver from an aqueous solution. The engineered surface modification is therefore integral with the substrate and loaded with silver by an ion exchange reaction. Using this technique the maximum inventory of silver for typical a mega-prosthesis is 6mg and this is greater than 300 times lower than the No Observable Adverse Affects Level (NOAEL). Scanning electron microscopy revealed that the silver was concentrated in pits and forming reservoirs of ionic silver exposed to the body tissues.

Laboratory-based studies focusing on the safety and efficacy of silver as a bactericidal agent have included investigation into cytotoxicity using fibroblast and osteoblast cell lines, the impact of silver in reducing corrosion and laboratory testing to establish if the modified surface has an effect on the wear and mechanical characteristics. A range of fatigue, static, tensile pull off tests were performed. The silver elution profiles for both silver loaded and HA coated over a silver loaded surface have been examined. Histological studies were also performed to examine the impact of the silver on osseointegration.

The in vitro results confirm that silver is an effective antimicrobial agent. The mechanical characterization studies have identified that the surface treatment has no or minimal impact on the implant surface. Early results of the elution studies are encouraging showing that the HA coating of a silver loaded surface does not “seal” in the silver.

To date (May 10) 147 silver treated mega-prostheses have been implanted since March 2006. The majority of implants were distal femoral (29%), proximal tibial (23%) or hemiplevic (10%). The most common indication was revision of a failed limb salvage reconstruction (58%), with the dominant cause of failure being infection. The next most common indication was bone tumour (31%) and the large majority were used in the high risk skeletal locations of the tibia (44%) and the pelvis (27%). Early clinical results are encouraging indicating a significant reduction in the incidence of infection.

Three implants have been retrieved. An analysis of a proximal humeral replacement that had been in situ for 6 mths identified that there was 10-20% remaining on the implant surface.

This novel process of “stitching-in” silver appears to be a safe and effective surface treatment in helping to control infections of mega-prostheses. This technology has the potential to be transferred to other arthroplasty joints.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 131 - 131
1 Jun 2012
Macmull S Bartlett W Miles J Blunn G Pollock R Carrington R Skinner J Cannon S Briggs T
Full Access

Polymethyl methacrylate spacers are commonly used during staged revision knee arthroplasty for infection. In cases with extensive bone loss and ligament instability, such spacers may not preserve limb length, joint stability and motion.

We report a retrospective case series of 19 consecutive patients using a custom-made cobalt chrome hinged spacer with antibiotic-loaded cement. The “SMILES spacer” was used at first-stage revision knee arthroplasty for chronic infection associated with a significant bone loss due to failed revision total knee replacement in 11 patients (58%), tumour endoprosthesis in four patients (21%), primary knee replacement in two patients (11%) and infected metalwork following fracture or osteotomy in a further two patients (11%). Mean follow-up was 38 months (range 24–70). In 12 (63%) patients, infection was eradicated, three patients (16%) had persistent infection and four (21%) developed further infection after initially successful second-stage surgery. Above knee amputation for persistent infection was performed in two patients.

In this particularly difficult to treat population, the SMILES spacer two-stage technique has demonstrated encouraging results and presents an attractive alternative to arthrodesis or amputation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 38 - 38
1 Mar 2012
Jaiswal P Aston W Grimer R Abudu A Carter S Blunn G Briggs T Cannon S
Full Access

We performed a retrospective review of 98 patients with malignant tumours of the periacetabular region, treated by resection and endoprosthetic reconstruction between 1971 and 2005 at the Royal National Orthopaedic Hospital, Stanmore and The Royal Orthopaedic Hospital, Birmingham.

The mean age of the patients was 43.6 years (10 to 76). 53 patients (54%) were male. The age distribution demonstrated peaks in the 2nd and 6th decades. The mean follow up was 65 months (2 to 405. The overall 10-year survival rate was 56% (determined by the Kaplan-Meier method).

54 patients (58.1%) had one or more complications. Infection was the most common (30%) with the majority occurring in the first 2 years. Dislocation occurred in 19 (20%) of our patients all in the first year following surgery. All were recurrent with a mean of 2.9 (2 to 6) episodes. Operations performed before 1994 were associated with a dislocation rate of 40.5% and after 1996 the rate was only 3.9% (p < 0.001).

Function was assessed according the Toronto Extremity Salvage Sore (TESS). The overall TESS was 59.4. In patients that had a major complication the TESS was 37.1 but in the group that did not the TESS was 70.3 (p < 0.001).

Men experienced higher rates of death, infection and revision than women (p < 0.05). The local recurrence rate was 31% with high grade tumours associated with higher recurrence rates (p < 0.05). Tumour resection in the ilium is associated with higher rates of infection than tumours located in the periacetabular region alone (p < 0.05).

This method of reconstruction is still associated with high complication rates. Function is good if a major complication can be avoided. The lower dislocation rate more recently is probably the result of improved surgical technique and the use of larger femoral heads.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 113 - 113
1 Feb 2012
Gupta A Burne DH Blunn G Briggs T Cannon S
Full Access

Chondrosarcoma is a malignant tumour and accounts for approximately 20% of bone sarcomas. The pelvis is one of the commonest sites. Chondrosarcoma of the pelvis lends itself to surgical excision and is relatively resistant to irradiation and chemotherapy. A long term survival analysis of this challenging condition is rarely reported in literature. We review and evaluate the oncological and functional results of all the patients operated at our centre and we analyse the survival analysis of these patients with special focus on the prognostic factors.

Fifty-four consecutive patients with chondrosarcoma of the pelvis who were treated at the Royal National Orthopaedic Hospital, Stanmore, UK between 1987 and 2001 were included in the study. Demographic data, case notes, histopathological results and follow-up data were obtained and statistically analysed.

There were 38 males and 16 females with a mean age of 48.4 years [18-77]. The chondrosarcomas were primary [n=38], secondary [n-7] or recurrences [n=9]. The anatomical sites in the pelvis were in the epicentre I [n=24], II [n=20] and III [n=10]. The surgical procedures performed were local resection [n=28], local resection and hip arthroplasty [n=6], hemipelvectomy (+endoprothesis) [n=16], hemipelvectomy [+fibular strut graf] [n=2] and hinquarter amputation [n=2]. The histological grade was Gr [n=27], Gr 2[n=20] and Gr 3 [n=7]. The complication rate was 24%:wound revision [9%], dislocation [8%] and infection [7%]. There was a 5, 10 and 15 year cumulative survival rate of 74%, 65% and 40%. The overall recurrence rate was 24%.

The factors associated with a worse prognosis were high histologic tumour grade, increasing patient age, anatomical location in site I and III, primary surgery outside of tumour centre, inadequate surgical margins, and those treated by local extension. Aggressive surgical approach significantly improves the prognosis of the patients with chondrosarcoma of the pelvis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 89 - 89
1 Feb 2012
Gupta A Stokes O Meswania J Pollock R Blunn G Cannon S Briggs T
Full Access

When performing limb salvage operations for malignant bone tumours in skeletally immature patients, it is desirable to reconstruct the limb with a prosthesis that can be lengthened without surgery at appropriate intervals to keep pace with growth of the contra-lateral side. We have developed a prosthesis that can be lengthened non-invasively. The lengthening is achieved on the principle of electromagnetic induction.

The purpose of this study was to look at our early experience with the use of the Non Invasive Distal Femoral Expandable Endoprosthesis. A prospective study of 17 skeletally immature patients with osteosarcoma of the distal femur, implanted with the prosthesis, was performed at the Royal National Orthopaedic Hospital, Stanmore. The patients were aged between 9 and 15 years (mean 12.1 years) at the time of surgery. Patients were lengthened at appropriate intervals in outpatient clinics. Patients were functionally evaluated using the Musculoskeletal Tumour Society (MSTS) Scoring System and the Toronto Extremity Severity Score (TESS). Average time from the implantation to the last follow-up was 18.2 months (range 14-30 months). The patients have been lengthened by an average of 25mm (4.25-55mm). The mean amount of knee flexion is 125 degrees. The mean MSTS score is 77% (23/30; range 11-29) and the mean TESS score is 72%. There have been two complications: one patient developed a flexion deformity of 25 degrees at the knee joint and one patient died of disseminated metastatic malignancy.

The early results from patients treated using this device have been encouraging. Using this implant avoids multiple surgical procedures and general anaesthesia. This results in low morbidity, cost savings and reduced psychological trauma. We do need additional data regarding the long-term structural integrity of the prosthesis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 90 - 90
1 Feb 2012
Stokes O Al-Hakim W Park D Unwin P Blunn G Pollock R Skinner J Cannon S Briggs T
Full Access

Background

Endoprosthetic reconstruction is an established method of treatment for primary bone tumours in children. Traditionally these were implanted with cemented intramedullary fixation. Hydroxyapatite collars at the shoulder of the implant are now standard on all extremity endoprostheses, but older cases were implanted without collars. Uncemented intramedullary fixation with hydroxyapatite collars has also been used in an attempt to reduce the incidence of problems such as aseptic loosening. Currently there are various indications that dictate which method is used.

Aims

To establish long term survivorship of cemented versus uncemented endoprosthesis in paediatric patients with primary bone tumours.