header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 256 - 257
1 Jul 2008
LANGLAIS F BELOT N ROPARS M LAMBOTTE J THOMAZEAU H
Full Access

Purpose of the study: Revision total knee arthroplasty with major destruction of bone and ligament tissue raises the problem of choosing between a complex reconstruction with a semi-constrained prosthesis or a much more simple procedure using a hinged prosthesis which transmits all of the stress to the bone anchors. The choice is basically one of longevity of the bony fixation of these constrained prostheses (and the deterioration of the articulated pieces). The present work reports the long-term outcome observed with constrained hinged prosthesis with a cemented press-fit stem implanted for bone tumors where the stress is even greater than for revisions.

Material and methods: The series included 32 prostheses implanted in young active subjects (mean age 33 years). A hinged, non-rotating Guepar II revision prosthesis was implanted. The part of the implant corresponding to the reconstruction after tumor resection was custom-made but the part implanted in «healthy» bone (for example the tibial piece in a patient with a femoral tumor) was the same as used for revisions prostheses inserted after loosening. On the healthy side, press-fit quadrangular stems were used, generally adapted to the endosteum by reaming. The prosthesis was fixed by simple mechanical adjustment before cementing, using the French paradox system (JBJS 2003). Before 1993, a metal-polyethylene bearing was used and after 1993 a metal-on-metal bearing without inserts.

Results: Among the 32 patients with a malignant tumor, 19 survived, seven with 2–10 years follow-up and 12 with 10–21 years follow-up. For the overall series, there was only one case of osteolysis on a tibial tumor which was revised at 12 years. There was one infection (hematogeneous) at 21 years (antibiotic cement). Prostheses with polyethylene inserts produced laxities or synovitis with 50% requiring synovectomy and insert replacement. There were no cases of synovitis for the metal-on-metal bearings. Two stems (inserted in adolescents) were too thin and had to be changed because of fracture without loosening.

Discussion: Prosthesis survival was 88% at ten years (1 osteolysis, 2 fractures on tumor), even for the constrained prostheses, even for young and active subjects.

Conclusion: The very good longevity of cemented pressfit stems (and the absence of synovitis and osteolysis with metal-on-metal bearings, and the low rate of infection) should be kept in mind as a possible alternative to very complex and possibly less predictable procedures in the presence of certain very severe loosenings with bone and ligament destruction.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1022 - 1026
1 Aug 2006
Langlais F Belot N Ropars M Lambotte JC Thomazeau H

We evaluated the long-term fixation of 64 press-fit cemented stems of constrained total knee prostheses in 32 young patients with primary malignant bone tumours. Initial stable fixation, especially in rotation, was achieved by precise fit of the stem into the reamed endosteum, before cementation. Complementary fixation, especially in migration and rotation, was obtained by pressurised antibiotic-loaded cement. The mean age at operation was 33 years (13 to 61). No patient was lost to follow-up; 13 patients died and the 19 survivors were examined at a mean follow-up of 12.5 years (4 to 21). Standard revision press-fit cemented stems were used on the side of the joint which was not involved with tumour (26 tibial and six femoral), on this side there was no loosening or osteolysis and stem survival was 100%. On the reconstruction side, custom-made press-fit stems were used and the survival rate, with any cause for revision as an end point, was 88%, but 97% for loosening or osteolysis. This longevity is similar to that achieved at 20 years with the Charnley-Kerboull primary total hip replacement with press-fit cemented femoral components.

We recommend this type of fixation when extensive reconstruction of the knee is required. It may also be suitable for older patients requiring revision of a total knee replacement or in difficult situations such as severe deformity and complex articular fractures.