header advert
Results 1 - 6 of 6
Results per page:
Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 224 - 224
1 Dec 2013
Alta T Morin-Salvo N Bessiere C Boileau P
Full Access

BACKGROUND:

Bony increased-offset reverse shoulder arthroplasty (BIO-RSA) creates a long-necked scapula, providing the benefits of lateralization. Experience with allogenic bone grafting of the glenoid in shoulder arthroplasty is mainly based on its use with total shoulder arthroplasty (TSA). Therefore, our study objectives were: 1) verify if the use of BIO-RSA together with glenoid surface grafting with allogenic bone would provide similar benefits (clinical and functional) as found with autologous bone, 2) determine if allograft could be a good alternative in the absence of (good quality) autograft bone, and 3) to see if the allograft would incorporate with the native glenoid bone.

METHODS:

We included 25 patients (19 female, 6 male) in this prospective study. Indications for BIO-RSA were: fracture sequalle (n = 9), revisions (n = 11), 4-part humerus fracture (n = 1), rheumatoid arthritis (n = 1) and cuff tear arthropathy (CTA) with poor humeral head bone quality/osteonecrosis (n = 3). Mean (± SD) age 70 ± 11 years (range, 44–86). Clinical evaluation consisted of ROM, Constant scores, patient satisfaction (Subjective Shoulder Value (SSV)) and noted complications. Radiographic and CT scan evaluation consisted of bone graft healing, bone graft resorption/lysis, glenoid component loosening, inferior scapular notching, spur formation and anterior/posterior scapular notching. Mean follow-up was 34 ± 10 months (24–62).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 3 - 3
1 Dec 2013
Alta T de Toledo JM Loss JF Janssen TW Van der Scheer J Veeger D( Willems WJ
Full Access

Background:

It is not well known how different external loads influence shoulder kinematics and muscle activity in patients with shoulder prostheses. Study objective: define shoulder kinematics and determine the scapulothoracic contribution to total shoulder motion, in combination with shoulder muscle activity and the degree of co-contraction, of patients with total (TSA) and reverse shoulder arthroplasties (RSA) and healthy individuals during rehabilitation exercises using different loading conditions.

Methods:

Shoulder motions (anteflexion and elevation in the scapular plane) of 17 patients (20 shoulders) with a TSA, 8 patients (9 shoulders) with a RSA and 15 healthy subjects were measured using anelectromagnetic tracking device. A force transducer recorded force signals during loaded conditions (without external load, 1 kg and elastic resistance). Electromyographic (EMG) activity of the deltoid (anterior, middle, posterior parts), latissimus dorsi, pectoralis major (clavicular and sternal parts), teres major and serratus anterior was recorded and the degree of co-contraction calculated.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 223 - 223
1 Dec 2013
Alta T Decroocq L Moineau G Brassart N Favard L Sirveaux F Clavert P Boileau P
Full Access

BACKGROUND:

Bony healing of tuberosities around shoulder prostheses is difficult to obtain in the elderly patient. We hypothesized that reattachment of the tuberosities, performed in combination with bone grafting, around a specific reverse shoulder fracture-prosthesis (RSFP) would favour improved tuberosity healing and shoulder mobility in elderly patients with displaced proximal humerus fractures.

METHODS:

We included 49 patients (50 shoulders)(45 female, 4 male) in this prospective study. Mean (± SD) age 80 ± 4 years (range, 70–88). Clinical evaluation consisted of ROM, VAS (pain), Constant scores, patient satisfaction (Subjective Shoulder Value (SSV)) and noted complications. Radiological evaluation consisted of tuberosity healing and component loosening. Mean follow-up 18 ± 8 months (12–39).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 225 - 225
1 Dec 2013
Alta T Morin-Salvo N Bessiere C Moineau G Boileau P
Full Access

Introduction:

Lateralization of reversed shoulder arthroplasty provides improvement in range of motion and decreases inferior scapular notching. The purpose of this study was to verify if the autologous cancelous bone graft harvested from the humeral head does heal constantly in a large cohort of patients followed for a long time

Methods:

Cohort of 92 consecutive patients operated between 2006 and 2010 with a BIORSA for definitive shoulder pseudoparalysis, secondary to cuff tear arthropathy (CTA) or massive, irreparable cuff tear (MCT). The autogenous cancelous graft was harvested from humeral head in all cases. Eight patients were lost for follow up, and four died before 2 years. The remaining 80 patients underwent clinical, radiographic and CT assessment at a minimum FU of 24 months. Mean age was 73 years. Three independent observers evaluated notching, partial or total glenoid or humeral loosening and viability of the graft. Constant-Murley score, range of motion and subjective shoulder value (SSV) were recorded. The mean follow up was 39 months (range 24–74 months).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 27 - 27
1 Sep 2012
Alta T Coghlan J Troupis J Bell S
Full Access

The purpose of this study was to determine if the use of a new 4 Dimensional CT scan aids the clinician in defining the size and area of the scapular bone to be removed arthroscopically in patients with Snapping Scapular Syndrome.

From January 2009 – January 2011 nine consecutive patients with Snapping Scapular Syndrome were included. In six patients, (mean age 21±5 years, range 15–27) conservative treatment failed. These patients were positioned prone and demonstrated their snapping motion during the 7 seconds duration of the scan. The 4D CT machine scans 16 cm volumes in 0.3 seconds. It also scans motion, allowing a 3D reconstruction of the scapulothoracic joint, its’ movements and the dynamic area of impingement of the scapula on the surrounding structures. This scan has already improved arthroscopic removal of the supero-medial angle of the scapula.

The scan showed in one case not only snapping of the superior medial angle of the scapula on the 2nd rib, but also extra bone impinging on the 3rd rib. Another case showed no real impingement but movement of the 2nd and 3rd rib by a tethering structure and a third case demonstrated impingement of the lateral third of the clavicle on the 2nd rib.

The images provided by this new 4D CT scan offer greater pre-operative insight on the pathology in each individual patient with Snapping Scapular Syndrome. Therefore, we feel that it is a valuable addition to the assessment and treatment of these patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 28 - 28
1 Sep 2012
Alta T Miller D Coghlan J Troupis J Bell S
Full Access

The purpose of this study was to determine the motion pattern of the Acromio-Clavicular (AC) joint in a normal shoulder with the use of the new 4 Dimensional CT scan.

From April 2010 till January 2011 fourteen healthy volunteers (4 female, 10 male)(mean age 42±11 years) with no previous history of shoulder complaints participated in this study. The 4D CT machine scans motion, allowing a 3D reconstruction of the shoulder joint and its movements. Patients were positioned supine with their arm elevated 90° in the sagittal plane. During the 7 seconds duration of the scan they adducted their arm at that level and then elevated their arm upwards resisted by the gantry for 4 seconds, in this way simulating the clinical Bell-van Riet test for AC pathology.

In the transverse plane the mean AC joint space measured in the neutral position is 1.8±0.5 mm. While adducting the arm the AC joint narrows 0.0±0.4 mm (with a positive value being narrowing and a negative value widening). On resisted elevation the joint space is narrowed 0.2±0.6 mm. The mean antero-posterior (AP) translation in this same plane is 0.2±2.2 mm on adduction (with a positive value being posterior translation of the clavicle and a negative value anterior translation) and 0.4±2.9 mm on resisted elevation.

The new 4D CT scan demonstrates that the AC joint in a normal shoulder mainly translates in an AP direction, rather than being narrowed or widened, when the arm is adducted (with or without resisted active elevation).