header advert
Results 1 - 6 of 6
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 11 - 11
1 Dec 2022
Tolgyesi A Huang C Akens M Hardisty M Whyne C
Full Access

Bone turnover and the accumulation of microdamage are impacted by the presence of skeletal metastases which can contribute to increased fracture risk. Treatments for metastatic disease may further impact bone quality. The present study aims to establish a preliminary understanding of microdamage accumulation and load to failure in osteolytic vertebrae following stereotactic body radiotherapy (SBRT), zoledronic acid (ZA), or docetaxel (DTX) treatment.

Twenty-two six-week old athymic female rats (Hsd:RH-Foxn1rnu, Envigo, USA) were inoculated with HeLa cervical cancer cells through intracardiac injection (day 0). Institutional approval was obtained for this work and the ARRIVE guidelines were followed. Animals were randomly assigned to four groups: untreated (n=6), spine stereotactic body radiotherapy (SBRT) administered on day 14 (n=6), zoledronic acid (ZA) administered on day 7 (n=5), and docetaxel (DTX) administered on day 14 (n=5). Animals were euthanized on day 21. T13-L3 vertebral segments were collected immediately after sacrifice and stored in −20°C wrapped in saline soaked gauze until testing. µCT scans (µCT100, Scanco, Switzerland) of the T13-L3 segment confirmed tumour burden in all T13 and L2 vertebrae prior to testing. T13 was stained with BaSO4 to label microdamage. High resolution µCT scans were obtained (90kVp, 44uA, 4W, 4.9µm voxel size) to visualize stain location and volume. Segmentations of bone and BaSO4 were created using intensity thresholding at 3000HU (~736mgHA/cm3) and 10000HU (~2420mgHA/cm3), respectively. Non-specific BaSO4 was removed from the outer edge of the cortical shell by shrinking the segmentation by 105mm in 3D. Stain volume fraction was calculated as the ratio of BaSO4 volume to the sum of BaSO4 and bone volume. The L1-L3 motion segments were loaded under axial compression to failure using a µCT compatible loading device (Scanco) and force-displacement data was recorded. µCT scans were acquired unloaded, at 1500µm displacement and post-failure. Stereological analysis was performed on the L2 vertebrae in the unloaded µCT scans. Differences in mean stain volume fraction, mean load to failure, and mean bone volume/total volume (BV/TV) were compared between treatment groups using one-way ANOVAs. Pearson's correlation between stain volume fraction and load to failure by treatment was calculated using an adjusted load to failure divided by BV/TV.

Stained damage fraction was significantly different between treatment groups (p=0.0029). Tukey post-hoc analysis showed untreated samples to have higher stain volume fraction (16.25±2.54%) than all treatment groups (p<0.05). The ZA group had the highest mean load to failure (195.60±84.49N), followed by untreated (142.33±53.08N), DTX (126.60±48.75N), and SBRT (95.50±44.96N), but differences did not reach significance (p=0.075). BV/TV was significantly higher in the ZA group (49.28±3.56%) compared to all others. The SBRT group had significantly lower BV/TV than the untreated group (p=0.018). Load divided by BV/TV was not significantly different between groups (p=0.24), but relative load to failure results were consistent (ZA>Untreated>DTX>SBRT). No correlations were found between stain volume fraction and load to failure.

Focal and systemic cancer treatments effect microdamage accumulation and load to failure in osteolytic vertebrae. Current testing of healthy controls will help to further separate the effects of the tumour and cancer treatments on bone quality.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 15 - 15
1 Dec 2022
Tolgyesi A Huang C Akens M Hardisty M Whyne C
Full Access

Bone turnover and the accumulation of microdamage are impacted by the presence of skeletal metastases which can contribute to increased fracture risk. Treatments for metastatic disease may further impact bone quality. The present study aims to establish a preliminary understanding of microdamage accumulation and load to failure in osteolytic vertebrae following stereotactic body radiotherapy (SBRT), zoledronic acid (ZA), or docetaxel (DTX) treatment.

Twenty-two six-week old athymic female rats (Hsd:RH-Foxn1rnu, Envigo, USA) were inoculated with HeLa cervical cancer cells through intracardiac injection (day 0). Institutional approval was obtained for this work and the ARRIVE guidelines were followed. Animals were randomly assigned to four groups: untreated (n=6), spine stereotactic body radiotherapy (SBRT) administered on day 14 (n=6), zoledronic acid (ZA) administered on day 7 (n=5), and docetaxel (DTX) administered on day 14 (n=5). Animals were euthanized on day 21. T13-L3 vertebral segments were collected immediately after sacrifice and stored in −20°C wrapped in saline soaked gauze until testing. µCT scans (µCT100, Scanco, Switzerland) of the T13-L3 segment confirmed tumour burden in all T13 and L2 vertebrae prior to testing. T13 was stained with BaSO4 to label microdamage. High resolution µCT scans were obtained (90kVp, 44uA, 4W, 4.9µm voxel size) to visualize stain location and volume. Segmentations of bone and BaSO4 were created using intensity thresholding at 3000HU (~736mgHA/cm3) and 10000HU (~2420mgHA/cm3), respectively. Non-specific BaSO4 was removed from the outer edge of the cortical shell by shrinking the segmentation by 105mm in 3D. Stain volume fraction was calculated as the ratio of BaSO4 volume to the sum of BaSO4 and bone volume. The L1-L3 motion segments were loaded under axial compression to failure using a µCT compatible loading device (Scanco) and force-displacement data was recorded. µCT scans were acquired unloaded, at 1500µm displacement and post-failure. Stereological analysis was performed on the L2 vertebrae in the unloaded µCT scans. Differences in mean stain volume fraction, mean load to failure, and mean bone volume/total volume (BV/TV) were compared between treatment groups using one-way ANOVAs. Pearson's correlation between stain volume fraction and load to failure by treatment was calculated using an adjusted load to failure divided by BV/TV.

Stained damage fraction was significantly different between treatment groups (p=0.0029). Tukey post-hoc analysis showed untreated samples to have higher stain volume fraction (16.25±2.54%) than all treatment groups (p<0.05). The ZA group had the highest mean load to failure (195.60±84.49N), followed by untreated (142.33±53.08N), DTX (126.60±48.75N), and SBRT (95.50±44.96N), but differences did not reach significance (p=0.075). BV/TV was significantly higher in the ZA group (49.28±3.56%) compared to all others. The SBRT group had significantly lower BV/TV than the untreated group (p=0.018). Load divided by BV/TV was not significantly different between groups (p=0.24), but relative load to failure results were consistent (ZA>Untreated>DTX>SBRT). No correlations were found between stain volume fraction and load to failure.

Focal and systemic cancer treatments effect microdamage accumulation and load to failure in osteolytic vertebrae. Current testing of healthy controls will help to further separate the effects of the tumour and cancer treatments on bone quality.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_3 | Pages 2 - 2
1 Mar 2021
Changoor A Suderman R Alshaygy I Fuhrmann A Akens M Safir O Grynpas M Kuzyk P
Full Access

Patients undergoing revision surgery of a primary total hip arthroplasty often exhibit bone loss and poor bone quality, which make achieving stable fixation and osseointegration challenging. Implant components coated in porous metals are used clinically to improve mechanical stability and encourage bone in-growth. We compared ultra-porous titanium coatings, known commercially as Gription and Porocoat, in an intra-articular model by press-fitting coated cylindrical implants into ovine femoral condyles and evaluating bone in-growth and fixation strength 4, 8 and 16 weeks post-operatively.

Bilateral surgery using a mini-arthrotomy approach was performed on twenty-four Dorset-Rideau Arcott rams (3.4 ± 0.8 years old, 84.8 ± 9.3 kg) with Institutional Animal Care Committee approval in accordance with the Canadian Council on Animal Care. Cylindrical implants, 6.2 mm in diameter by 10 mm in length with surface radius of curvature of 35 mm, were composed of a titanium substrate coated in either Porocoat or Gription and press-fit into 6 mm diameter recipient holes in the weight-bearing regions of the medial (MFC) and lateral (LFC) femoral condyles. Each sheep received 4 implants; two Gription in one stifle (knee) and two Porocoat in the contralateral joint. Biomechanical push-out tests (Instron ElectroPuls E10000) were performed on LFCs, where implants were pushed out relative to the condyle at a rate of 2 mm/min. Force and displacement data were used to calculate force and displacement at failure, stiffness, energy, stress, strain, elastic modulus, and toughness. MFCs were fixed in 70% ethanol, processed undecalcified, and polished sections, approximately 70 µm thick (Exakt Micro Grinding system) were carbon-coated. Backscattered electron images were collected on a scanning electron microscope (Hitachi SU3500) at 5 kV and working distance of 5 mm. Bone in-growth within the porous coating was quantified using software (ImageJ). Statistical comparisons were made using a two-way ANOVA and Fisher's LSD post-hoc test (Statistica v.8).

Biomechanical evaluation of the bone-implant interface revealed that by 16 weeks, Gription-coated implants exhibited higher force (2455±1362 N vs. 1002±1466 N, p=0.046) and stress (12.60±6.99 MPa vs. 5.14±7.53 MPa, p=0.046) at failure, and trended towards higher stiffness (11510±7645 N/mm vs. 5010±8374 N/mm, p=.061) and modulus of elasticity (591±392 MPa vs. 256±431 MPa, p=0.61). Similarly, by 16 weeks, bone in-growth in Gription-coated implants was approximately double that measured in Porocoat (6.73±3.86 % vs. 3.22±1.52 %, p=0.045). No statistically significant differences were detected at either 4 nor 8 weeks, however, qualitative observations of the exposed bone-implant interface, made following push-out testing, showed more bony material consistently adhered to Gription compared to Porocoat at all three time points. High variability is attributed to implant placement, resulting from the small visual window afforded during surgery, unique curvatures of the condyles, and presence of the extensor digitorum longus tendon which limited access to the LFC.

Ultra-porous titanium coatings, know commercially as Gription and Porocoat, were compared for the first time in a challenging intra-articular ovine model. Gription provided superior fixation strength and bone in-growth, suggesting it may be beneficial in hip replacement surgeries where bone stock quality and quantity may be compromised.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 52 - 52
1 Jul 2020
Clement A Whyne C Hardisty M Wilkie P Akens M
Full Access

Quantitative assessment of metastatic involvement of the bony spine is important for assessing disease progression and treatment response. Quantification of metastatic involvement is challenging as tumours may appear as osteolytic (bone resorbing), osteoblastic (bone forming) or mixed. This investigation aimed to develop an automated method to accurately segment osteoblastic lesions in a animal model of metastatically involved vertebrae, imaged with micro computed tomography (μCT).

Radiomics seeks to apply standardized features extracted from medical images for the purpose of decision-support as well as diagnosis and treatment planning. Here we investigate the application of radiomic-based features for the delineation of osteoblastic vertebral metastases. Osteoblastic lesions affect bone deposition and bone quality, resulting in a change in the texture of bony material physically seen through μCT imaging. We hypothesize that radiomics based features will be sensitive to changes in osteoblastic lesion bone texture and that these changes will be useful for automating segmentation.

Osteoblastic metastases were generated via intracardiac injection of human ZR-75-1 breast cancer cells into a preclinical athymic rat model (n=3). Four months post inoculation, ex-vivo μCT images (µCT100, Scanco) were acquired of each rodent spine focused on the metastatically involved third lumbar vertebra (L3) at 7µm/voxel and resampled to 34µm/voxel.

The trabecular bone within each vertebra was isolated using an atlas and level-set based segmentation approach previously developed by our group. Pyradiomics, an open source Radiomics library written in python, was used to calculate 3D image features at each voxel location within the vertebral bone. Thresholding of each radiomic feature map was used to isolate the osteoblastic lesions.

The utility of radiomic feature-based segmentation of osteoblastic bone tissue was evaluated on randomly selected 2D sagittal and axial slices of the μCT volume. Feature segmentations were compared to ground truth osteoblastic lesion segmentations by calculating the Dice Similarity Coefficient (DSC). Manually defined ground truth osteoblastic tumor segmentations on the μCT slices were informed by histological confirmation of the lesions.

The radiomic based features that best segmented osteoblastic tissue while optimizing computational time were derived from the Neighbouring Gray Tone Difference Matrix (NGTDM). Measures of coarseness yielded the best agreement with the manual segmentations (DSC=707%) followed by contrast, strength and complexity (DSC=6513%, 5428%, and 4826%, respectively).

This pilot study using a radiomic based approach demonstrates the utility of the NGTDM features for segmentation of vertebral osteoblastic lesions. This investigation looked at the utility of isolated features to segment osteoblastic lesions and found modest performance in isolation. In future work we will explore combining these features using machine learning based classifiers (i.e. decision forests, support vector machines, etc.) to improve segmentation performance.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 35 - 35
1 Sep 2012
Lo V Akens M Wise-Milestone L Yee A Wilson B Whyne CM
Full Access

Purpose

Maintenance of vertebral mechanical stability is of paramount importance to prevent pathologic fractures and resultant neurologic compromise in individuals with spinal metastases. Current non-surgical treatments for vertebral metastases (i.e. chemotherapy, bisphophonates (BP) and radiation) yield variable responses in the tumour and surrounding bone. Photodynamic therapy (PDT) is a novel, minimally-invasive technology that utilizes a drug activated by light at a specific non-thermal wavelength to locally destroy tumour cells. Previously, we observed that PDT can ablate cancer cells within bone and yield short-term (1-week) improvements in vertebral architecture and biomechanical strength, particularly when combined with BP therapy. This study aims to evaluate the effects of PDT in vertebral bone over a longer (6-week) time period, alone and combined with previous BP treatment, to determine if improvements in skeletal architecture and strength are maintained.

Method

Fourty healthy rnu/rnu rats were randomly assigned to four treatment groups: (i) untreated control, (ii) BP only, (iii) PDT only and (iv) PDT following BP. BP treatments were administered on day 0 via subcutaneous injection of zoledronic acid. PDT was administered on day 7 via an intravenous injection of BPD-MA photosensitizer. A flat-cut optical fiber was inserted percutaneously adjacent to lumbar vertebra L2. After a 15-minute drug-light interval, 75J of light energy was delivered from a 690nm laser. Six weeks later, animals were euthanized. Structural properties of excised L2 vertebral bodies were quantified through semi-automated analysis of micro-CT images. In of the specimens, mechanical properties were evaluated by loading the L2 vertebral body to failure in axial compression. The remaining L2 vertebrae were analyzed for morphology, osteoid formation and osteoclast activity using histological methods.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 32 - 32
1 Sep 2012
Whyne CM Leckie A Akens M Woodhouse K Yee A
Full Access

Purpose

Nucleus pulposus (NP) replacements represent a less invasive alternative for treatment of early stage degenerative disc disease (DDD). Hydrogel based NP replacements are of particular interest as they can be injected/implanted using minimally invasive surgical (MIS) techniques to re-establish mechanical integrity and as a scaffold for regeneration. A thiol-modified hyaluronan elastin-like polypeptide (TMHA/EP) hydrogel crosslinked using polyethylene diacrylate has shown promise as a potential NP replacement for DDD in vitro. This study aims to assess the mechanical properties of this hydrogel when injected into an induced early stage DDD porcine model and to determine the optimal injection method for delivery. It is hypothesized that minimally invasive injection of the TMHA/EP material can restore mechanical behaviour of spinal motion segments in early stage DDD.

Method

Intervertebral disc (IVD) degeneration was enzymatically induced in L2-L3 and L4-L5 lumbar levels in 10 Yorkshire boars using chondroitinase ABC (n=20 discs). An additional three animals served as healthy controls (n=6 discs). Following a four-week degradation period, the TMHA/EP solution (250microL in a 3:1 weight ratio) was injected into the degenerate NP of 16 discs by one of two MIS techniques: A direct 18G needle injection or a modified kyphoplasty technique (MKT) in which a balloon angiocatheter was inserted through an 11G trocar into the IVD and inflated to create a cavitary defect that was then filled with the hydrogel. Excised motion segments were tested in axial compression under a load of 400N and in axial rotation (AR), lateral bending (LB) and flexion/extension (FE) at 5Nm. Range of motion (ROM), neutral zone (NZ) length, NZ stiffness (NZStiff) and axial compressive stiffness (ACStiff) were quantified.