header advert
Results 1 - 2 of 2
Results per page:
Applied filters
General Orthopaedics

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 146 - 146
1 Apr 2019
Sugita T Aizawa T Miyatake N Miyamoto S Sasaki A Maeda I Honma T Kamimura M Takahashi A
Full Access

Introduction

Patient self-reported outcome scales have recently been used to evaluate total knee arthroplasty (TKA) outcomes. Many follow-up studies have been conducted on patients undergoing TKA; however, they have mostly reported outcomes after unilateral TKA. We believe that a longitudinal study after bilateral TKA will be more useful in evaluating the quality of life (QOL) of such patients.

Objectives

The objective of this study was to longitudinally evaluate QOL using the Japanese Knee Osteoarthritis Measure (JKOM). Objective outcomes were assessed using the Knee Society Score (KSS) and the Timed Up and Go test (TUG) for more than 5 years after bilateral TKA. Furthermore, QOL and objective outcomes were compared between younger (age ≤ 80 years at the final follow-up point) and older (age > 80 years) age groups.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 33 - 33
1 Jan 2016
Sugita T Miyatake N Sasaki A Maeda I Honma T Aizawa T
Full Access

Introduction

Various methods to manage medial tibial defects in primary total knee arthroplasty (TKA) have been described. According to Vail TP, metal augmentation is usually indicated for defect depth of >10 mm of the medial tibial plateau. The outcomes of metal augmentation have been described as excellent. Nevertheless, we believe that it is mandatory to preserve as much of the bone as possible for future revision surgeries. Therefore, we performed autologous impaction bone grafting even for large bone defects (defect depth of ≥10 mm) in primary TKA. The objectives of this study are to describe our bone grafting technique in detail and to assess the radiological outcomes of the grafted bone.

Methods

Between 2003 and 2011, 26 TKAs with autologous impaction bone grafting for ≥10 mm medial tibial defects were performed. The preoperative diagnoses were osteoarthritis in 17 knees, rheumatoid arthritis in 2 knees, osteonecrosis of the medial tibial condyle in 6 knees, and Charcot's joint in 1 knee. The average mediolateral width and depth of the medial tibial defects, measured after the horizontal osteotomy of the tibial articular surface, were 17.8 mm (range, 10–25 mm) and 12.0 mm (range, 10–23 mm), respectively. The average patient age at surgery was 73.2 years (range, 56–85 years). The patients were followed up for an average of 55 months (range 27–109 months).

Bone grafting technique: Multiple drill holes (white arrow) were made on the floor of the defect (A) and a morselized cancellous bone was impacted using the grip end of a metal hammer (white asterisk) and firm manual pressure to fill the defect. Thus, the firm impaction prevented bone cement from entering the space between the graft and the tibial host bed. An assistant's index finger (black asterisk) was used as a bank (B). The tibial component was fixed on the grafted bone (white asterisk) with bone cement (C). Internal fixation devices were not required, and stem extension was used in only Charcot's joint (defect depth=23 mm). Aftertreatment was the same as that for the usual TKAs without bone defects.