The Bone & Joint Journal
Vol. 103-B, Issue 8 | Pages 1339 - 1344
1 Aug 2021
Jain S Mohrir G Townsend O Lamb JN Palan J Aderinto J Pandit H

Aims

This aim of this study was to assess the reliability and validity of the Unified Classification System (UCS) for postoperative periprosthetic femoral fractures (PFFs) around cemented polished taper-slip (PTS) stems.

Methods

Radiographs of 71 patients with a PFF admitted consecutively at two centres between 25 February 2012 and 19 May 2020 were collated by an independent investigator. Six observers (three hip consultants and three trainees) were familiarized with the UCS. Each PFF was classified on two separate occasions, with a mean time between assessments of 22.7 days (16 to 29). Interobserver reliability for more than two observers was assessed using percentage agreement and Fleiss’ kappa statistic. Intraobserver reliability between two observers was calculated with Cohen kappa statistic. Validity was tested on surgically managed UCS type B PFFs where stem stability was documented in operation notes (n = 50). Validity was assessed using percentage agreement and Cohen kappa statistic between radiological assessment and intraoperative findings. Kappa statistics were interpreted using Landis and Koch criteria. All six observers were blinded to operation notes and postoperative radiographs.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_9 | Pages 36 - 36
1 May 2018
Jain S Magra M Dube B Veysi V Whitwell G Aderinto J Emerton M Stone M Pandit H
Full Access

Introduction

Reverse hybrid total hip replacement (THR) offers significant theoretical benefits but is uncommonly used. Our primary objective was to evaluate implant survival with all cause revision and revision for aseptic loosening of either component as endpoints.

Patients/Materials & Methods

Data was collected prospectively on 1, 088 (988 patients) consecutive reverse hybrid THRs. Mean patient age was 69.3 years (range, 21–94) and mean follow-up was 8.2 years (range, 5–11.3). No patients were lost to follow-up. Overall, 194 (17.8%) procedures were performed in patients under 60 years, 666 (61.1%) were performed in female patients and 349 (32.1%) were performed by a trainee. Acetabular components were ultra-high molecular weight polyethylene in 415 (38.1%) hips, highly cross-linked polyethylene in 669 (61.5%) hips and vitamin E stabilised polyethylene in 4 (0.4%) hips. Femoral stems were collared in 757 (69.7%) hips and collarless in 331 (30.3%) hips. Femoral head sizes were 28 mm in 957 (87.9%) hips and 32 mm in 131 (12.1%) hips. Survival analysis was performed using Kaplan Meier methodology. Log rank tests were used to asses differences in survival by age, gender, head size and surgeon grade.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 15 - 15
1 Nov 2015
Aqil A Hossain F Sheikh H Akinbamijo B Whitwell G Aderinto J Kapoor H
Full Access

Introduction

A fractured hip is the commonest cause of injury related death in the UK. Prompt surgery has been found to improve pain scores and reduce the length of hospital stay, risk of decubitus ulcer formation and mortality rates. The hip fracture Best Practice Tariff (BPT) aims to improve these outcomes by financially compensating services, which deliver hip fracture surgery within 36 hours of admission. Ensuring that delays are reserved for patients with conditions which compromise survival, but are responsive to medical optimisation, would facilitate enhanced outcomes and help to achieve the 36-hour target.

We aimed to identify medical conditions associated with patients failing to achieve the 36-hour cut off, and evaluated whether these were justified by calculating their associated mortality risk.

Methods

Prospectively collected data from the National Hip Fracture Database (NHFD) and inpatient hospital records and blood results from a single major trauma centre were obtained. Complete data sets from 1361 patients were available for analysis. Medical conditions contributing to surgical delay beyond the BPPT (Best Practice Tariff Target) 36-hour cut off, were identified and analysed using univariate and multivariate regression analyses, whilst adjusting for covariates. The mortality risk associated with each factor contributing to surgical delay was then calculated using univariate and hierarchical regression techniques.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 11_Supple_A | Pages 36 - 41
1 Nov 2012
Aderinto J Lulu OB Backstein DJ Safir O Gross AE

Eighteen hip fusions were converted to total hip replacements. A constrained acetabular liner was used in three hips. Mean follow up was five years (two to 15). Two (11%) hips failed, requiring revision surgery and two patients (11%) had injury to the peroneal nerve. Heterotopic ossification developed in seven (39%) hips, in one case resulting in joint ankylosis. No hips dislocated.

Conversion of hip fusion to hip replacement carries an increased risk of heterotopic ossification and neurological injury. We advise prophylaxis against heterotropic ossification. When there is concern about hip stability we suggest that the use of a constrained acetabular liner is considered. Despite the potential for complications, this procedure had a high success rate and was effective in restoring hip function.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 7 | Pages 970 - 973
1 Sep 2004
Aderinto J Brenkel IJ

We have reviewed prospective data on 1016 patients who underwent unilateral total hip replacement to establish the pre-operative risk factors associated with peri-operative blood transfusion. Most patients who required transfusion were older and were of lower weight, height, pre-operative haemoglobin level and body mass index than patients who were not transfused.

Multivariate analysis revealed that only the pre-operative haemoglobin level and the patients weight were identified as significant independent factors increasing the need for transfusion (p < 0.001). A haemoglobin level below 12 g/dl was associated with a threefold increase in transfusion requirement.