Vol. 104-B, Issue 7 | Pages 833 - 843
1 Jul 2022
Kayani B Baawa-Ameyaw J Fontalis A Tahmassebi J Wardle N Middleton R Stephen A Hutchinson J Haddad FS

Aims

This study reports the ten-year wear rates, incidence of osteolysis, clinical outcomes, and complications of a multicentre randomized controlled trial comparing oxidized zirconium (OxZr) versus cobalt-chrome (CoCr) femoral heads with ultra-high molecular weight polyethylene (UHMWPE) and highly cross-linked polyethylene (XLPE) liners in total hip arthroplasty (THA).

Methods

Patients undergoing primary THA were recruited from four institutions and prospectively allocated to the following treatment groups: Group A, CoCr femoral head with XLPE liner; Group B, OxZr femoral head with XLPE liner; and Group C, OxZr femoral head with UHMWPE liner. All study patients and assessors recording outcomes were blinded to the treatment groups. The outcomes of 262 study patients were analyzed at ten years’ follow-up.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_4 | Pages 18 - 18
1 Apr 2022
Kayani B Baawa J Fontalis A Tahmassebi J Wardle N Middleton R Hutchinson J Haddad FS
Full Access

This study reports the ten-year polyethylene liner wear rates, incidence of osteolysis, clinical outcomes and complications of a three-arm, multicentre randomised controlled trial comparing Cobalt-Chrome (CoCr) and Oxidised Zirconium (OxZr) femoral heads with ultra-high molecular weight polyethylene (UHMWPE) versus highly cross-linked polyethylene (XLPE) liners in total hip arthroplasty (THA).

Patients undergoing THA from four institutions were prospectively randomised into three groups. Group A received a CoCr femoral head and XLPE liner; Group B received an OxZr femoral head and XLPE liner; and Group C received an OxZr femoral head and UHMWPE liner. Blinded observers recorded predefined outcomes in 262 study patients at regular intervals for ten years following THA.

At ten years follow-up, increased linear wear rates were recorded in group C compared to group A (0.133 ± 0.21 mm/yr vs 0.031 ± 0.07 mm/yr respectively, p<0.001) and group B (0.133 ± 0.21 mm/yr vs 0.022 ± 0.05 mm/yr respectively, p<0.001). Patients in group C were associated with increased risk of osteolysis and aseptic loosening requiring revision surgery compared with group A (7/133 vs 0/133 respectively, p=0.007) and group B (7/133 vs 0/135 respectively, p=0.007). There was a non-significant trend towards increased liner wear rates in group A compared to group B (0.031 ± 0.07 mm/yr vs 0.022 ± 0.05 mm/yr respectively, p=0.128). All three groups were statistically comparable preoperatively and at ten years follow-up when measuring normalised Western Ontario and McMaster Universities Osteoarthritis Index(p=0.410), short-form-36 (p = 0.465 mental, p = 0.713 physical), and pain scale scores (p=0.451).

The use of UHMWPE was associated with progressively increased annual liner wear rates after THA. At ten years follow-up, this translated to UHMWPE leading to an increased incidence of osteolysis and aseptic loosening requiring revision THA, compared with XLPE. Femoral heads composed of OxZr were associated with a non-significant trend towards reduced wear rates compared to CoCr, but this did not translate to any differences in osteolysis, functional outcomes, or revision surgery between the two treatments groups.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 15 - 15
1 Nov 2021
Kayani B Bawwa J Tahmassebi J Fontalis A Wardle N Middleton R Shardlow D Hutchinson J Haddad F
Full Access

This study reports the ten-year outcomes of a three-arm, multicentre randomised controlled trial comparing Cobalt-Chrome (CoCr) and Oxidised Zirconium (OxZr) femoral heads with ultra-high molecular weight polyethylene (UHMWPE) versus highly cross-linked polyethylene (XLPE) liners in total hip arthroplasty (THA).

Patients undergoing THA from four institutions were prospectively randomised into three groups. Group A received a CoCr femoral head and XLPE liner; Group B received an OxZr femoral head and XLPE liner; and Group C received an OxZr femoral head and UHMWPE liner. The outcomes of 262 study patients were analysed at ten years follow-up.

At ten years, increased linear wear rates were recorded in group C compared to group A (0.133 ± 0.21 mm/yr vs 0.031 ± 0.07 mm/yr respectively, p<0.001) and group B (0.133 ± 0.21 mm/yr vs 0.022 ± 0.05 mm/yr respectively, p<0.001). Patients in group C had increased risk of osteolysis and aseptic loosening requiring revision surgery compared with group A (7/133 vs 0/133 respectively, p=0.007) and group B (7/133 vs 0/135 respectively, p=0.007). There was a non- significant trend towards increased liner wear rates in group A compared to group B (0.031 ± 0.07 mm/yr vs 0.022 ± 0.05 mm/yr respectively, p=0.128). All three groups were statistically comparable preoperatively and at ten years follow-up from a clinical score perspective.

The use of UHMWPE was associated with progressively increased annual liner wear rates. At ten years follow-up, this translated to an increased incidence of osteolysis and aseptic loosening requiring revision, compared with XLPE. Femoral heads composed of OxZr were associated with a non-significant trend towards reduced wear rates compared to CoCr, but this did not translate to any differences in osteolysis, functional outcomes, or revision surgery between the two treatments groups.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_16 | Pages 5 - 5
1 Oct 2017
Miller A Stenning M Torrie A Issac A Hutchinson J Hutchinson J Chopra I Mohanty K
Full Access

Bertolotti first described articulation of the L5 transverse process with the sacrum as a cause of back pain in 1917. Since then little attention has been payed to these atypical articulations despite their high reported incidence.

Here we describe our early experience of surgical treatment and propose a validated CT based classification of lumbosacral segment abnormalities (LSSA).

400 lumbosacral CT scans were reviewed (NBT), a classification devised and incidence of abnormalities recorded. 40 patients were selected and 4 independent observers classified each scan. Case notes for all patients (C&V) who received steroid injections into or surgical excision of LSSAs were reviewed. Results as follows:

5 types of abnormality were identified.

Type 0 - normal

Type 1 - asymmetrical shortening of the iliolumbar ligament

Type 2 - transverse process of L5 within 2mm of the sacrum

Type 3 - diarthrodial joint (3A: no evidence of degeneration 3B: degenerative change)

Type 4 - transverse process and sacrum have fused

Type 5 - extends to L4

54.5% of patients had abnormalities. The kappa values for the intra-observer results were 0.69 to 0.88 and the inter-observer ratings gave a combined score of over 0.7 indicating substantial agreement.

Our CT classification of LSSAs is both straight forward to use and repeatable. The incidence of these abnormalities is higher in our population of CT scans compared to previous published series using plain radiographs. All patients treated with surgical excision of established articulations (Type 3A or above) reported good or excellent outcomes following excision.


The Bone & Joint Journal
Vol. 97-B, Issue 7 | Pages 883 - 889
1 Jul 2015
Jassim SS Patel S Wardle N Tahmassebi J Middleton R Shardlow DL Stephen A Hutchinson J Haddad FS

Oxidised zirconium (OxZi) has been developed as an alternative bearing surface for femoral heads in total hip arthroplasty (THA). This study has investigated polyethylene wear, functional outcomes and complications, comparing OxZi and cobalt–chrome (CoCr) as part of a three-arm, multicentre randomised controlled trial. Patients undergoing THA from four institutions were prospectively randomised into three groups. Group A received a CoCr femoral head and highly cross-linked polyethylene (XLPE) liner; Group B received an OxZi femoral head and XLPE liner; Group C received an OxZi femoral head and ultra-high molecular weight polyethylene (UHMWPE) liner. At five years, 368 patients had no statistically significant differences in short-form-36 (p = 0.176 mental, p = 0.756 physical), Western Ontario and McMaster Universities Osteoarthritis Index (p = 0.847), pain scores (p = 0.458) or complications. The mean rate of linear wear was 0.028 mm/year (standard deviation (sd) 0.010) for Group A, 0.023 mm/year (sd 0.010) for Group B, and 0.09 mm/year (sd 0.045) for Group C. Penetration was significantly higher in the UHMWPE liner group compared with both XLPE liner groups (p < 0.001) but no significant difference was noted between CoCr and OxZi when articulating with XLPE (p = 0.153). In this, the largest randomised study of this bearing surface, it appears that using a XLPE acetabular liner is more important in reducing THA component wear than the choice of femoral head bearing, at mid-term follow-up. There is a non-significant trend towards lower wear, coupling OxZi rather than CoCr with XLPE but long-term analysis is required to see if this observation changes with time and becomes significant.

Cite this article: Bone Joint J 2015;97-B:883–9.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_7 | Pages 16 - 16
1 May 2015
Torrie A Harding I Hutchinson J Nelson I Adams M Dolan P
Full Access

The study aim was to simulate oblique spinous process abutment (SPA) in cadaveric spines and determine how this affects coupled motion in the coronal plane.

L4-S1 spinal segments from thirteen cadavers were loaded on a materials testing machine in pure compression at 1kN for 10 minutes. Reflective markers on the vertebral bodies were used to assess coronal motion using a motion analysis system. Oblique SPA was simulated by attaching moulded oblique aluminium strips to the L4 and L5 spinous processes. In each specimen, both a right- and left-sided SPA was simulated, in random order, and compression at 1kN was again applied. All tests were then repeated after endplate fracture. Coronal plane motion at baseline was compared with values following simulated SPA using Mann Whitney U-tests.

Pre-fracture, SPA increased coronal motion by 0.28° and 0.34° on right and left sides respectively, compared to baseline, only the former was significant (P=0.03). Post-fracture, SPA decreased coronal motion by 0.36° and 0.46° on right and left sides respectively, only the latter was significant (P=0.03). Simulated oblique SPA in the intact spine initiated an increase in coronal motion during pure axial loading. These findings provide limited evidence that oblique SPA may be causative in DLS.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_15 | Pages 15 - 15
1 Oct 2014
Rocos B Hutchinson J
Full Access

An often neglected component of sagittal balance in adolescent idiopathic scoliosis (AIS) is the cervical spine. The cervical spine is capable of compensating for large sagittal deformities by altering head position, but in doing so may give rise to symptoms when the extremes of cervical compensatory mechanisms are reached. This paper seeks to define whether AIS patients have a different cervical lordosis pre and post corrective surgery when compared to normal adolescents.

A review of the literature was carried out in order to define normal cervical lordosis in adolescents. A retrospective analysis of 81 patients with a confirmed diagnosis of idiopathic scoliosis who had received corrective surgery was carried out, and pre and post op cervical lordosis of C1– C7 and C2– C7 were independently measured and recorded using full length sagittal spine radiographs. This data was compared to the 95% confidence interval (95% CI) of cervical lordosis in controls to show if AIS patients showed different cervical spine lordosis before or after corrective surgery.

A literature search showed that normal cervical spine lordosis values are poorly described. However, some values have been published. One study (paper A) gives values of −16° (95%CI −12–20°) for male C2– C7 lordosis and −15° (95% CI −12.5–17.5°) for female C2– C7 adolescents. Another reference (paper B) gives values of −8.4 (95%CI −6.7–10.1°) for male and −1.9 (95%CI −0.5–3.3°) for female adolescents for the same C2– C7 measurements. Our values for male patients for pre op C2– C7 lordosis was −1.2 (95%CI −8.5–6.1°) and 9° (95%CI 2.9– 15.1°) for females. Post op values were 10.6° (95%CI 2.4–18.8°) for males and 8.3° (95%CI 4.8–11.8°) for females.

The values of cervical lordosis in our series show that patients with AIS have a significantly different cervical lordosis when compared to normal values both pre and post deformity correction (p < 0.05). A complete understanding of how the cervical spine is positioned prior to surgery is critical, as flattening the thoracic spine during corrective surgery could give rise to cervical pain and sagittal imbalance if the ability of the cervical spine to compensate for the new spinal position is exceeded.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_15 | Pages 3 - 3
1 Oct 2014
Clark E Taylor H Hutchinson J Nelson I Wordsworth B Harding I Tobias J
Full Access

AIS is present in 3–5% of the general population. Large curves are associated with increased pain and reduced quality of life. However, no information is available on the impact of smaller curves, many of which do not reach secondary care. The objective of this project was to identify whether or not there is any hidden burden of disease associated with smaller spinal curves.

The Avon Longitudinal Study of Parents and Children (ALSPAC) is a population-based birth cohort that recruited over 14,000 pregnant women from the Bristol area between 1991–1992 and has followed up their offspring regularly. At aged 15 presence or absence of spinal curvature ≥6degrees was identified using the validated DXA Scoliosis Measure in 5299 participants. At aged 18 a structured pain questionnaire was administered to 4083 participants. Chi-squared was used to investigate any association between presence of a spinal curve at aged 15 and self-reported pain at aged 18 years. Sensitivity analyses were performed by rerunning analyses after excluding those who were told at aged 13 they had a spinal curve (n=27), and using a higher spinal curve cut-off of ≥10degrees.

Full data was available for 3184 participants. Of these, 56.8% were female, and 4.2% non-white reflecting the local population. 202 (6.3%) had a spinal curve ≥6degrees and 125 (3.9%) had a curve ≥10degrees. The mean curve size was 12degrees. 140/202 (69.3%) had single curves, and 57.4% of these were to the right. In total 46.3% of the 3184 participants reported aches and pains that lasted for a day or longer in the previous month, consistent with previous literature. 16.3% reported back pain. Those with spinal curves ≥6degrees were 42% more likely to report back pain than those without (OR 1.42, 95%CI 1.00 to 2.02, P=0.047). In addition, those with spinal curves had more days off school, were more likely to avoid activities that caused their pain, were more likely to think that something harmful is happening when they get the pain, and were more afraid of the pain than people without spinal curves (P<0.05). Sensitivity analyses did not change results.

We present the first results from a population-based study of the impact of small spinal curves and identify an important hidden burden of disease. Our results highlight that small scoliotic curves that may not present to secondary care are nonetheless associated with increased pain, more days off school and avoidance of activities.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_15 | Pages 32 - 32
1 Oct 2014
Robinson P Filer J Upadhyay N Hutchinson J
Full Access

The prevalence of degenerative spondylolisthesis (DS) increases with age. With an ageing population there will be increasing demands for adult deformity surgery, with associated significant financial and complication costs. The prevalence of lytic spondylolisthesis (LS) is 6–8%. Our clinical observation is that it is extremely rare to see LS in the presence of DS and therefore the objective was to formally describe the prevalence of LS in combination with DS to assess the hypothesis that 6–8% of patients with DS should also have LS. If this is not the case it may further our understanding of the pathogenesis of DS, which could aid in future prevention or treatment.

A retrospective review of erect lateral lumbar radiographs demonstrating lumbar spondylolisthesis was performed. Radiographs were identified and analysed on the hospital Synapse Picture Archiving and Communication System (PACS). Search criteria were radiographs requested by primary care and patients aged over 60.

101 patients with spondylolisthesis were identified. 89% were requested for back or leg pain. There were 89 patients with DS (69.7% women) and 12 with LS (83% men). The average age of DS and LS patient was 75 and 70 respectively (not significant). There were no cases found with both DS and LS. This was significantly different to the expected amount of 6% (p=0.03). The level of DS was at L3/4 in 11.2% (n=10), L4/5 in 79.8% (n=71) and L5/S1 in 16.9% (n=15). 2 levels were involved in 7 patients. 94.4% (n=84) demonstrated a Meyerding grade 1 slip and 5.6% (n=5) grade 2 slip. For LS the slipped level was at L5/S1 in all cases. 66.7% (n=8) had a grade 1 slip and 33.3% (n=4) a grade 2 slip.

We found no cases of lytic spondylolisthesis in the presence of degenerative spondylolisthesis. We hypothesis that the presence of spondylolysis or lytic spondylolisthesis may be protective against development of degenerative spondylolisthesis. More work is needed to explore this further.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_6 | Pages 20 - 20
1 Apr 2014
Miller A Islam K Grannum S Morris S Hutchinson J Nelson I Hutchinson J
Full Access

Aim:

To compare the degree of deformity correction achieved using cobalt chromium versus titanium alloy rods in patients with Adolescent Idiopathic Scoliosis.

Method:

A retrospective comparison of two cohorts of patients with Adolescent Idiopathic Scoliosis treated with posterior segmental pedicle screw fixation using either Titanium or Cobalt Chromium rods. The radiographs of 50 patients treated before 2009 (Ti group) and 50 patients after 2009 (CoCr group) were reviewed for changes in: Main Coronal Curvature Sagittal Balance (C7 Plumb Line) Kyphosis (T5-12)


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_6 | Pages 9 - 9
1 Apr 2014
Grannum S Miller A Patel M Hutchinson J Hutchinson J Nelson I
Full Access

Aim:

The Lenke Classification for adolescent idiopathic scoliosis (AIS) classifies curves as nonstructural if they reduce to less than 25° on bending radiographs. We aimed to establish whether there is a significant difference in curves assessed as structural/ nonstructural when comparing bending radiographs to forced traction radiographs.

Methods:

We undertook a retrospective database review of 100 consecutive AIS patients having undergone surgical correction by the 2 senior authors, together with radiographic review. Curves were classified according to the Lenke system including modifiers. Magnitude of the minor curves were compared on plain PA standing radiographs, bending radiographs and forced traction radiographs.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_6 | Pages 28 - 28
1 Apr 2014
Lavelle D Morris S Torrie A Katsimihas M Hutchinson J Harding I Nelson I
Full Access

Aim:

Deep infection following paediatric spinal deformity surgery is a serious complication, which can also result in increased length of stay and significant cost implications. Our objective was to reduce deep infection rates following spinal deformity surgery.

Method:

All paediatric patients undergoing spinal deformity procedures between 2008 and 2010 (group 1) were prospectively followed up and deep infection rates recorded. In 2010, a review of infection rates necessitated a change in pre-operative, peri-operative, and post-operative practice. A scoliosis wound care pathway was implemented, which involved insertion of drains to protect wounds, strict dressing management performed by a Spinal Nurse Practitioner, and a telephone helpline for concerns about wound care and general peri-operative scoliosis care. The use of betadine wash and local antibiotic application intra-operatively were other measures instigated later in this period. All paediatric patients undergoing surgery between 2011 and 2012 (group 2) were then followed up and differences in infection rates between the two groups were analysed.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_6 | Pages 11 - 11
1 Apr 2014
Torrie P Purcell R Morris S Harding I Dolan P Adams M Nelson I Hutchinson J
Full Access

Aim:

To determine if patients with coronal plane deformity in the lumbar spine have a higher grade of lumbar spine subtype compared to controls.

Method:

This was a retrospective case/control study based on a review of radiological investigations in 250 patients aged over 40 years who had standing plain film lumbar radiographs with hips present. Measurements of lumbar coronal plane angle, lumbar lordosis, sacral slope, pelvic tilt and pelvic incidence were obtained. “Cases” with degenerative scoliosis (n=125) were defined as patients with a lumbar coronal plane angle of >10°.

Lumbar spine subtype was categorised (1–4) using the Roussouly classification. Lumbar spine subtype was dichotomised into low (type 1,2) or high (type 3,4). Prevalence of lumbar spine subtype in cases versus controls was compared using the Chi squared test. Pelvic incidence was compared using an unpaired T-test. Predictors of lumbar coronal plane angle were identified using stepwise multiple regression. Significance was accepted at P<0.05.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_6 | Pages 8 - 8
1 Apr 2014
Tokala D Grannum S Mehta J Hutchinson J Nelson I
Full Access

Aim:

To compare the ability of fulcrum bend and traction radiographs to predict correction of AIS using pedicle screw only constructs and to compare the fulcrum bending correction index (FBCI) with a new measurement: the traction correction index (TCI).

Method:

Retrospective radiographic analysis of eighty patients, average age 14 yrs, who underwent posterior correction of scoliosis using pedicle screw only construct. Analysis was carried out on the pre-op and immediate post-op PA radiographs and the pre-op fulcrum bend and traction radiographs. Correction rate, fulcrum flexibility, traction flexibility, FBCI and TCI was calculated.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_6 | Pages 29 - 29
1 Apr 2014
Morris S Marriott H Walsh P Kane N Harding I Hutchinson J Nelson I
Full Access

Aim:

Recent guidelines have been published by the Association of Neurophysiological Scientists / British Society for Clinical Neurophysiology (ANS/BSCN) regarding the use of intra-operative neurophysiological monitoring (IOM) during spinal deformity procedures. We present our unit's experience with IOM and the compliance with national guidelines.

Method:

All patients undergoing intra-operative spinal cord monitoring during adult and paediatric spinal deformity surgery between Jan 2009 and Dec 2012 were prospectively followed. The use of somatosensory-evoked potentials (SSEPs) and motor-evoked potentials (MEPs) was recorded and monitoring outcomes were compared to post-operative clinical neurological outcomes. Compliance with the national ANS/BSCN guidelines was assessed.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 186 - 186
1 Mar 2013
Jassim S Patel S Wardle N Tahmassebi J Middleton R Shardlow D Stephen A Hutchinson J Haddad F
Full Access

Introduction

In Total Hip Arthroplasty (THA), polyethylene wear reduction is key to implant longevity. Oxidized Zirconium (OxZi) unites properties of a ceramic bearing surface and metal head, producing less wear in comparison to standard Cobalt-Chromium (CoCr) when articulating with Cross-linked polyethylene (XLPE) in vitro. This study investigates in vivo polyethylene (PE) wear, outcomes and complications for these two bearing couples in patients at 5 year follow-up

Methods

400 patients undergoing THA across four institutions were prospectively randomised into three groups. Group I received a cobalt-chrome (CoCr) femoral head/ cross-linked polyethylene (XLPE) liner; Group II received an OxZi femoral head/ ultrahigh molecular weight polyethylene (UHMWPE) liner; Group III received an OxZi femoral head/XLPE liner. All bearing heads were 32 mm. Linear wear rate was calculated with Martell computer software. Functional outcome and complications were recorded.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 183 - 183
1 Jan 2013
Torrie A Stenning M Wynne-Jones G Hutchinson J Nelson I
Full Access

Objective

Pyogenic spinal infection (PSI) is an increasingly common presentation to spinal units in the UK. Its investigation and diagnosis is often delayed. The purpose of this study was to determine the prognostic significance of the inflammatory marker levels on admission on achieving a positive microbiological diagnosis in patients with PSI.

Study design

Retrospective case series review of all patients presenting with PSI to our unit.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXI | Pages 9 - 9
1 Jul 2012
Stenning M Issac A Torrie A Hutchinson J Hutchinson J
Full Access

Objective

The purpose of this study is to describe and validate a CT based classification of lumbosacral segment abnormalities.

Method

400 CT scans were retrospectively reviewed, a classification devised and incidence of abnormalities recorded. 5 types of abnormality were identified. Type 0 is normal; Type 1 describes an asymmetrical shortening of the iliolumbar ligament; Type 2's have the transverse process of L5 within 2 mm of the sacrum but not forming a joint; Type 3's have formed a diarthrodial joint, with 3A's showing no evidence of degeneration and 3B's displaying degenerative changes; In type 4's the transverse process and sacrum have fused; Type5's have involvement of L4. In order to validate the classification, 40 scans were selected with a full cross section of types. 4 independent observers classified each scan in 2 separate sessions, 2 weeks apart.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 100 - 100
1 Jul 2012
Vaughan P Imam S Hutchinson J
Full Access

Purpose

To highlight the cardiovascular responses of a trainee and supervising consultant while performing Total Knee Arthroplasty (TKA) and to demonstrate the impact that supervision has on both their responses.

Methods

A third year orthopaedic trainee and his consultant underwent non-invasive, continuous cardiac monitoring while performing three primary TKAs. The consultant performed one TKA with the trainee assisting. The trainee then performed two TKAs as primary surgeon. The consultant supervised one TKA scrubbed and the other un-scrubbed.

A third person noted the timing of each distinct intra-operative step. A significant peak was defined as an increase in heart rate (HR) of >10%.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXVI | Pages 62 - 62
1 Jun 2012
Hughes D Hutchinson J Nelson I Harding I
Full Access

Computer assisted surgery is becoming more prevalent in spinal surgery with most published literature suggesting an improvement in accuracy and reduction in radiation exposure. This has been particularly highlighted in scoliosis surgery with regard to the placement of pedicle screws. Anecdotally this has been challenged with concerns with regard to the steep learning curve using this equipment and the high cost of purchasing said systems. The more traditional technique utilises the surgeon's knowledge of anatomic landmarks and tactile palpation added with fluoroscopy to place pedicle screws. We retrospectively looked at 161 scoliosis corrections performed using this technique over three years by 3 main surgeons at the same centre (Frenchay). With an average of 10 levels per procedure and over 2000 pedicle screws inserted. We reviewed the radiation time exposure and dose of radiation given during each case. Our results compared favourably to published data using computer and robot assisted surgery with an average exposure time of 80 seconds and a mean dose of 144 mGy using a standard C-arm guided fluoroscopy. Our study suggests that armed with good surgical knowledge and technique it is possible to obtained low levels of radiation exposure of benefit to both patient and the operating team.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 109 - 109
1 Apr 2012
Bertram W Katsimihas M Harding I Nelson I Hutchinson J
Full Access

Post traumatic stress disorder (PTSD) is well recognised in children having repeated medical/surgical procedures. It has been suggested that it is common in young children undergoing growing rod treatment with ongoing lengthening and the inevitable accompanying complications.

We present an index case history, review the literature in order to infer a correlation for the incidence of PTSD and discuss diagnosis and management.

We present an index case history of PTSD in a young child undergoing growing rod treatment for scoliosis. The literature was reviewed for PTSD in paediatric surgery and pathologies requiring multiple treatments. Spinal surgery is compared with paediatric cancer, burns, organ failure/transplant, cardiopulmonary disease, inflammatory bowel disease, cystic fibrosis and limb lengthening.

No published studies examine PTSD in children undergoing multiple spinal surgeries. One paper reports that children undergoing growing rod treatments show “behavioural alterations” and changes in psychosocial behaviour, including anxiety on entering the operating room and broken rod worries. A recent spine meeting presentation referred to this.

Psychosocial problems occur in up to 30% of children with chronic or life-threatening illnesses which involve ongoing treatments. Factors such as age, parental anxiety and previous adverse medical experiences influence anxiety, depression and PTSD.

Based on our index case and methodological correlation with similar pathologies, we fell that PTSD is a genuine concern in children who have repeated spinal operations.

This paper is part of an ongoing study, but we believe that the spinal community should be aware of this diagnosis and its management.

Ethics approval: Audit Interest Statement: None


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 22 - 22
1 Apr 2012
Bertram W Katsimihas M Nelson I Hutchinson J Harding I
Full Access

Lumbar myelography was a commonly performed procedure but was superseded by MRI and CT which were low risk and provided cross-sectional information. The majority of MRI and CT evaluations are static and supine whereas myelography may be loaded and dynamic. This study evaluates the role of myelography in patients with degenerative scoliosis in a modern surgical practice.

Patients with degenerative scoliosis and full imaging (plain radiographs, supine MRI, myelography, including CT myelography) were identified from our database between 2006-2009. Differences between findings of MRI and myelography/CT myelography were noted and whether this subsequently affected treatment.

21 patients fulfilled inclusion criteria. Mean age 68 (45-82), 17 females. 18/21(85.7%) myelograms revealed findings not seen on MRI. 15 patients had a single abnormality, 1 had two and in 2 patients there were 3 new abnormalities. These were facet/ligamentous bulging in 13, a single spondylolisthesis, retrolisthesis and lateral subluxation. On CT a foraminal osteophyte and a pars defect were seen. In 4 cases supine investigation revealed more than MRI. In 7 patients management changed as a result of myelography/CT. There have been no complications of myelography in our unit of the total 270 performed.

Myelography is a safe and useful tool in the management of patients with degenerative scoliosis. MRI scan alone understates the true nature of central and lateral recess stenosis. Not only does myelography show more stenosis in the loaded spine, but static myelography and CT myelography are also an invaluable tool in these patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 77 - 77
1 Apr 2012
Khokhar R Aylott C Bertram W Katsimihas M Hutchinson J
Full Access

Traditionally, spinal surgeons placed radiographs on viewing boxes in a manner (PA) to replicate the view they would have at surgery. The introduction of digital Picture Archiving and Communications System (PACS) appears to have had marked impact upon this convention. Some Units have the ability to lock digital radiographs such that they are always viewed in the same manner and cannot be reversed.

Following ‘two near misses’ we carried out a survey to confirm the previous practice with radiographs; to ascertain the current practice with PACS and to find out whether the variation in practice could lead to clinical mishaps and harm to patients.

Questionnaires were completed by practicing spinal surgeons.

Previous and current practice of viewing radiographs. Either actual or potential wrong side surgery. Opinions as to whether a single convention was important were recorded.

78 % Spine surgeons used to flip radiographs over prior to introduction of PACS. With PACS, 56 % spine surgeons flip the radiographs over in clinic and 72 % in theatre so to resemble viewing spine from behind. 56% Surgeons had nearly operated on the wrong side of the spine while 94 % have seen or heard of a patient operated on the wrong side. 72 % Spine surgeons agree that the radiographs should be flipped over so as to resemble the spine as viewed intraoperatively.

There is need for a single convention in spine surgery to view radiographs to avoid potential clinical mistakes.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 48 - 48
1 Apr 2012
Aylott C Nicholls P Killburn-Toppin F Bertram W Robertson P Hutchinson J
Full Access

Auckland City Hospital, Auckland, New Zealand.

To show that the spinous processes (SPs) increase in size with age.

To investigate the incidence of SP abutment, relationship to disc degeneration and age related kyphosis.

Describe patterns of SP neoarticulation in relation to back pain and intersegmental axial rotation and deformity.

We reviewed 200 Abdominal CTs, CT myelograms and 100 standing x-rays (age 18-90 years).

We measured SP size, interspinous gap, patterns of neoarticulation, disc height, lumbar lordosis and axial rotation.

We compared symptomatic and asymptomatic groups.

A 30-50% increase in SP size coupled combined with a loss of disc height leads to increasing rates of SP abutment after the age of 35 years. 30% of people over the age of 60 years have SP abutment.

There is a 15 degree increase in standing lumbar kyphosis with age.

Four patterns of SP neoarticulation are seen. Degenerative changes in the SP articulation increase by more than 80% in a symptomatic cohort.

Oblique SP articulation is 2.5 times more likely in symptomatic individuals and associated with a rotational intersegmental deformity.

Ageing is accompanied by SP enlargement and abutment, contributing to a loss of lumbar lordosis.

Patterns of neoarticulation and degeneration appear associated with back pain and rotational deformity.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 426 - 426
1 Jul 2010
Bertram W Ahmad R Orpen N Barton T Nelson I Hutchinson J
Full Access

The main objective of our review was to access the inter-net websites providing information on non operative treatment of scoliosis and to assess the evidence for each treatment in the medical literature.

Methods: We identified top five search engines at the site www.searchengines.com. The search term “scoliosis treatment” was entered into each search engine. The websites were reviewed and each search engine produced from 145,354 to 5460,000 results. We identified twenty non operative treatments for scoliosis. We further evaluated and studied these non operative treatments by using each treatment as a search term. The accuracy of these treatments was checked by doing a medical literature review. We used Medline 1950 to November 2008 and Embase 1980 to November 2008.

Results: 260 websites were duplicated in the five search engines, 103 websites only mentioned surgical treatment of scoliosis, and 10 websites could not be accessed at the time of the study. We evaluated the remaining 127 websites using the key words “scoliosis treatment” to generate a list of twenty unique non operative scoliosis treatments. These treatments when entered individually into the search engines enabled us to produce a list of these treatments in decreasing order of frequency. This was based on the number of results that each treatment generated.

These treatments were then entered for search in Medline and Embase, only 45% (9/20) of these treatments were found to have been described in the medical literature.

Conclusion: Our study did reveal that information on non operative treatment of scoliosis leaves much to be desired. Based on this study we recommend that it is the duty of the treating surgeon to warn the patients of the potential danger of misinformation that is abundant on the internet.

Ethics approval: None

Interest Statement: None


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 383 - 383
1 Jul 2010
Orpen N Barton T Ahmad R Nelson I Hutchinson J
Full Access

Spinal lipomatosis is seldom reported in spinal literature and although the condition occurs commonly, we seldom recognise it in reviewing spinal MRI scans. We aim to highlight the condition and show MRI signs to allow easier recognition. We also introduce a new method of evaluation of the severity of the condition using T1 MRI axial views to evaluate the area of the spinal canal involved in the pathological process.

We have evaluated 30 patients with a diagnosis of spinal lipomatosis made on sagittal MRI scanning of the spine. The T1 and T2 axial images have been evaluated using standard digital software which allows calculation of the surface area occupied by fat and allows representation of this as a ratio to total canal diameter. This has then been correlated to the traditional method of classifying lipomatosis on sagittal MRI sequences.

We have found this method useful and believe it provides a more accurate representation of how fat in the canal may produce symptoms of nerve compression. This shows that the condition behaves more like our traditional understanding of spinal stenosis with symptoms more likely when the relationship of fat to canal reaches greater than 50%. This approach to spinal lipomatosis has not been described before but we feel produces a better understanding of the condition than we have had before by using a classification based on purely on sagittal MRI sequences.

Ethics approval: None Audit

Interest Statement: No conflict of interest


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 493 - 493
1 Sep 2009
Brown S Mehta J Nelson I Hutchinson J
Full Access

Background: Lenke 1 curves can be treated by a selective thoracic fusion. The lumbar curve, if flexible, can spontaneously correct itself in terms of the Cobb angle and the apical vertebral translation. De-rotation of the thoracic spine with current instrumentation systems has been reported. However, it is unclear what effect this would have on the un-instrumented lumbar curve.

Objective: We report on the changes in the apical rotation (AVR) of the un-instrumented lumbar curve following selective thoracic fusion in Lenke 1B and 1C curves.

Methods and patients: 32 patients with idiopathic scoliosis underwent a selective thoracic fusion for a Lenke 1B or 1C curves. We assessed the apical vertebral rotation of the lumbar curve before and after the selective thoracic fusion. This was measured by the Pedriolle method on the pre-, and post-operative erect radiographs. Cobb angle of the thoracic and lumbar curves before and after the fusion were also measured.

Results: The apical lumbar rotation changed form a mean of 10.7 deg (pre-op) to 7.33 deg (post-op), with a correction index of 19.8 %. The Cobb angle of the instrumented thoracic curve changed from a mean of 54.4 deg (pre-op) to a mean 24.9 deg (postop), the mean correction index was 52.9 %. The mean Cobb angle of the un-instrumented lumbar curve changed from 29.36 deg (pre-op) to 17.76 deg (post-op), with a correction index of 38.8 %.

Conclusion: Selective thoracic fusion of Lenke 1B and 1C leads to an improvement of the rotation un-instrumented lumbar curve.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 477 - 477
1 Aug 2008
Wynne-Jones G Manidakis N Harding I Hutchinson J Nelson I
Full Access

Pedicle screw fixation has become the norm for the surgical correction of adolescent idiopathic scoliosis (AIS), with much biomechanical research into different types of rod screw constructs. The senior authors have experience using a monoaxial screw only construct in the correction of AIS since 2003 and the polyaxial screw only construct since 2005.

We retrospectively reviewed our experience in the first ten patients with AIS using the polyaxial system and compared this against 18 patients who had been corrected using the monoaxial system. Table I shows our results, expressed as mean and ranges or means ± SD for the main thoracic and lumbar curves.

Our early results show that the polyaxial system produces similar correction of both the thoracic and lumbar curves as compared to the monoaxial system in the immediate post-operative period. Though the absolute values for the lumbar curves differ between the two groups the percentage correction shows no statistical difference.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 577 - 577
1 Aug 2008
Murray JR Hogan NA Trezies A Hutchinson J Parish E Read JW Cross MJ
Full Access

Background: There is limited evidence on long-term outcome following ACL reconstruction. Concern has been raised that degenerative joint disease is common in the long-term and this may be associated with use of patellar tendon autograft.

Methods: 162 patients underwent single-surgeon arthroscopic ACL reconstruction (1991–1993) were identified from our prospective database. Patient-centred outcome was by Lysholm and Subjective IKDC score, objective outcome measures were clinical examination, arthrometry and X-rays.

Results: 13 year outcome (10–15 years) is known in 115/161 patients (71%). The median subjective scores were 94% (Lysholm) and 90% (IKDC). Ipsilateral graft rupture rate was 4%, with contralateral ACL injury in 8%. Mean manual maximum KT 1000 was 9mm in the grafted knee and 8mm in the contralateral knee. Clinical laxity scores of grade 0 or 1 were found in over 93% patients. Radiographically 66% were normal or near normal (Grade A or B). When compared to the contra-lateral uninjured knee we found no significant difference in the proportion of normal/near normal x-rays (grade A/B) versus abnormal/severe (grade C/D) for the medial, lateral nor patellofemoral compartments. There was no significant difference in the radiological IKDC grades in the medial compartment when compared to the contra-lateral uninjured knee, but there was a difference in the lateral and patellofemoral joints.

Conclusions: At 13 years patellar tendon ACLR provides excellent patient satisfaction, with clinically objective knee stability and low risk of re-rupture. Radiographically degenerative change was seen in 34%. There was no significant side to side difference to the uninjured contralateral medial knee joint, but there was a small but significant difference in the lateral and patellofemoral joints. The lateral joint differences may reflect underlying bone bruising at the time of injury. We do not believe that the patellar tendon autograft is the cause of arthrosis after BTB ACLR.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 255 - 255
1 May 2006
Hutchinson J Parish E Cross M
Full Access

Introduction: Stiffness following Total Knee Arthroplasty is a serious and debilitating complication. There are many different patient and surgical factors implicated in it cause. Previous studies have suggested that it will occur in approximately 1% of TKR patients. Arthrofibrosis is an uncommon but potentially debilitating cause in an otherwise well positioned implant. The cause of this abnormal scar formation is as yet unknown. The treatment of this condition remains difficult and controversial. Revision of the TKR has been suggested as the gold standard treatment as other operative strategies have had limited success. Our approach to this problem has been to conserve the prosthesis and try to release the scar tissue.

Aim: The aim of this study is to assess the results of open arthrolysis in the treatment of established arthrofibrosis.

Method: 1522 patients undergoing primary uncemented TKR have been prospectively followed up (2022 TKR’s) using the International Knee Society Scores. 13 patients underwent open Arthrolysis for stiffness post-op (Incidence 0.64%). The average age was 65 (range 50–78). 6 cases were simultaneous bilateral procedures (Incidence 1.2% of simultaneous bilateral procedures). The average time between TKR and arthrolysis was 14 months. Our average follow-op was 7.2 years (range 2 – 10 years)

Results: The average ROM just prior to Arthrolysis was 58°. The average ROM six months after surgery had improved to 91° (p< 0.05). The average ROM at last follow-up was 95° (p< 0.05) with an average Knee Society score of 155 (pain 83, function 72).

No patients have required revision of their components.

Conclusions: We have found open arthrolysis a successful approach to post-op arthrofibrosis. Although a large procedure it has been well tolerated by our patients. They have had an improvement in range of movement by six months which has been maintained up to 10 years.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 86 - 86
1 Mar 2006
Hutchinson J Parish E Cross M
Full Access

Introduction The efficacy of total knee replacement (TKR) surgery is well documented throughout the literature. Results from cemented and cementless series reveal similar long-term reliable results in terms of function and survival. Less, however, is known of the long-term results of uncemented TKR with the use of hydroxyapatite (HA). The purpose of this paper is to present the long-term results of a series of TKR using an uncemented, HA-coated, PCL retaining prosthesis.

Method During the period from August 1992 to December 1994 all patients undergoing TKR surgery were prospectively recorded in a consecutive series. Results were recorded pre- and post-surgery at regular intervals (both clinically and radiographically). The combined clinical Knee Society Score was used to evaluate outcome with routine radiographic evaluation done at 10 years.

Results 217 patients (126 female, 91 male) were included in the study with 322 knees in total (75 simultaneous bilateral, 23 staged bilateral and 126 unilateral). The mean age was 70 years (range 34–88 years) with a mean follow-up of 11 years (range 10–12 years). 47 (21.7%) patients were deceased at 10 years. The principle indication for surgery was osteoarthritis. There has been 1 revision (0.3%) for infection in this series to date. There have been 7 (2.2%) deep infections requiring surgical intervention and 4 (1.2%) supracondylar fractures.

At 10 years, mean knee score was 174 with range of movement 0–111 degrees. 95.4% of the series has currently been successfully followed up. 9 patients were unable to be contacted and lost to follow up. With revision as an end point, the rate of survival for the prosthesis at 10 years is 99.4%. Assuming worst case scenario for patients lost to follow up, survivorship is 95.4%.

Conclusion The survival of this prosthesis has shown to compare favourably to other published results. A low rate of revision and infection combined with excellent clinical and functional outcomes suggests the use of HA with an uncemented TKR produces reliable long-term results.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 373 - 373
1 Sep 2005
Limbers J Hutchinson J Obey P Robinson A
Full Access

Aim Pressure on inpatient beds can lead to high cancellation rates for inpatient elective orthopaedic surgery. The use of day surgery facilities is one way to overcome this problem. We set out to assess patient satisfaction after Scarf osteotomy, as a day case procedure, to help determine whether this is a valid routine practice.

Method Twenty-six consecutive patients (25 female and 1 male) undergoing Scarf metatarsal osteotomy, lateral release, medial capsulorraphy, and Akin osteotomy were prospectively followed up. Three patients had bilateral procedures resulting in 29 operations being performed. All had their surgery under midfoot block with intravenous sedation administered by an anaesthetist. All patients were discharged on the day of surgery with oral analgesia and contact details of the on-call orthopaedic registrar. A telephone interview and questionnaire were performed on day 3 and day 7 post-operatively.

Results Post-operative pain: seven patients (24%) had no pain, 15 (51%) mild pain, five (17%) moderate pain and two (6%) had episodes of severe pain. Twenty-eight patients (96%) were satisfied with their level of postoperative analgesia. Twenty-eight patients (96%) would have the surgery as a day case again. One patient would not due to post-operative nausea and vomiting.

Post-operative problems experienced by patients: 17 patients (58%) had no problems, six (20%) felt that their pain was a problem, five (17%) experienced bleeding/bruising and one (3%) felt faint.

Survey of medical services contacted by patients: 26 (89%) contacted no-one, one (3%) day surgery unit staff, two (3%) their GP and one (3%) the hospital.

Significance Scarf osteotomy can be successfully performed under midfoot block with a high degree of patient satisfaction. This has the potential to reduce cancellations due to inpatient bed shortage.


The Journal of Bone & Joint Surgery British Volume
Vol. 77-B, Issue 6 | Pages 928 - 932
1 Nov 1995
Hutchinson J Neumann L Wallace W

Patients suffering from generalised convulsions may dislocate their shoulders either anteriorly or posteriorly. Those with anterior dislocation are likely to have recurrent episodes because of secondary bony damage to the anterior rim of the glenoid and head of the humerus. In such patients there is high rate of failure of the standard soft-tissue stabilisation procedures. We have therefore devised a bone buttress operation in which autograft or allograft is secured to the deficient anterior glenoid and shaped to form an extension of its articular surface. We report our experience in 14 patients with grandmal epilepsy and recurrent anterior dislocation of the shoulder. After the bone buttress operation there were no further dislocations and all patients were satisfied despite a small restriction in their range of movement. We believe this to be the operation of choice for patients with this difficult problem.