Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 80 - 80
7 Aug 2023
Liu A Qian K Dorzi R Alabdullah M Anand S Maher N Kingsbury S Conaghan P Xie S
Full Access

Abstract

Introduction

Knee braces are limited to providing passive support. There is currently no brace available providing both continuous monitoring and active robot-assisted movements of the knee joint. This project aimed to develop a wearable intelligent motorised robotic knee brace to support and monitor rehabilitation for a range of knee conditions including post-surgical rehabilitation. This brace can be used at home providing ambulatory continuous passive movement obviating the need for hospital admissions.

Methodology

A wearable sensing system monitoring knee range of motion was developed to provide remote feedback to clinicians and real-time guidance for patients. A prototype of an exoskeleton providing dynamic motion assistance was developed to help patients complete their exercise goals and strengthen their muscles. The accuracy and reliability of those functions were validated in human participants during exercises including knee flexion/extension (FE) in bed and in chair, sit-to-stand and stand-to-sit.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 74 - 74
7 Aug 2023
Alabdullah M Liu A Xie S
Full Access

Abstract

Rehabilitation exercise is critical for patients’ recovery after knee injury or post-surgery. Unfortunately, adherence to exercise is low due to a lack of positive feedback and poor self-motivation. Therefore, it is crucial to monitor their progress and provide supervision. Inertial measurement unit (IMUs) based sensing technology can provide remote patient monitoring functions. However, most current solutions only measure the range of knee motion in one degree of freedom. The current IMUs estimate the orientation-angle based on the integrated raw data, which might lack accuracy in measuring knee motion. This study aims to develop an IMU-based sensing system using the absolute measured orientation-angle to provide more accurate comprehensive monitoring by measuring the knee rotational angles.

An IMU sensing system monitoring the knee joint angles, flexion/extension (FE), adduction/abduction (AA), and internal/external (IE) was developed. The accuracy and reliability of FE measurements were validated in human participants during squat exercise using measures including root mean square error (RMSE) and correlation coefficient.

The RMSE of the three knee angles (FE, AA, and IE) were 0.82°, 0.26°, and 0.11°, which are acceptable for assessing knee motion. The FE measurement was validated in human participants and showed excellent accuracy (correlation coefficient of 0.99°). Further validation of AA and IE in human participants is underway.

The sensing system showed the capability to estimate three knee rotation angles (FE, AA, and IE). It showed the potential to provide comprehensive continuous monitoring for knee rehabilitation exercises, which can also be used as a clinical assessment tool.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 44 - 44
1 Jul 2020
Wallace R Xie S Simpson H
Full Access

Trabecular bone is a multiscale hierarchical composite material that is known to display time-dependant properties. However, most biomechanical models treat this material as time independent. Time-dependant properties, such as creep and relaxation, are thought to play an important role in many clinically relevant orthopaedic issues: implant loosening, vertebral collapse, and non-traumatic fractures. In this study compressive multiple-load-creep-unload-recovery (MLCUR) tests were applied to human trabecular bone specimens.

15 female femoral heads were harvested, with full ethical approval and patient consent, at the time of total hip replacement. Central cores were extracted and cut parallel under constant irrigation. Specimens were embedded in end caps using surgical cement, an epoxy tube was secured around the end caps and filled with phosphate buffered saline (PBS) to ensure the specimens remained hydrated throughout. Embedded samples were scanned by microCT (SkyScan 1172, Bruker) at a resolution of 17µm to determine microarchitecture. Bone volume fraction (BVF) was used to represent microarchitecture. Specimens had an effective length of 16.37mm (±1.90SD) with diameter of 8.08mm (±0.05SD), and BVF of 19.22% (±5.61SD).

The compressive MLCUR tests were conducted at 5 strain levels, 2000µε, 4000µε, 6000µε, 8000µε and 10000µε. At each strain level, the load required to maintain each strain was held for 200s (creep) then unloaded to 1N for 600s (recovery). The instantaneous, creep, unloading and recovered strains can be easily obtained from the strain-time curves. Stress-strain plots revealed the Young's modulus. Data was modelled using line of best fit with appropriate curve fitting. R2 values were used to indicate association. Mechanical testing demonstrated the expected time independent relationship between BVF and stiffness: higher stiffness was found for specimen with higher BVF and this was consistent for all strain levels.

Creep strain was found to depend on instantaneous strain and BVF. At low levels of instantaneous strain, there was a greater amount of creep strain in low BVF samples (R2 = 0.524). This relationship was no longer apparent at higher strain levels (R2 = 0.058). Residual strain also depended on the applied instantaneous strain and BVF: at low levels of strain, residual strain was similar with all BVF (R2 = 0.108) and at high levels of strain, residual strain was greater in low BVF samples (R2 = 0.319). The amount of instantaneous strain applied to each sample is constant, variations in stiffness result in different applied loads. In low BVF bone, the stiffness is also low, therefore the stress required to reach designed strain is also lower: yet, there is more creep and less recovery.

We have demonstrated that even at loads below recognised yield levels, time-dependence affects the mechanical response and residual strain is present. In cases of low BVF, deflection due to creep, and increased irrecoverable strain could have clinically relevant consequences, such as implant loosening and vertebral collapse. The role of time-dependant properties of bone is seldom considered. This data could be developed into a constitutive model allowing these time-dependant behaviours to be incorporated in finite element modelling, leading to better predictions of implant loosening, especially for lower quality bone.


Bone & Joint Research
Vol. 9, Issue 4 | Pages 162 - 172
1 Apr 2020
Xie S Conlisk N Hamilton D Scott C Burnett R Pankaj P

Aims

Metaphyseal tritanium cones can be used to manage the tibial bone loss commonly encountered at revision total knee arthroplasty (rTKA). Tibial stems provide additional fixation and are generally used in combination with cones. The aim of this study was to examine the role of the stems in the overall stability of tibial implants when metaphyseal cones are used for rTKA.

Methods

This computational study investigates whether stems are required to augment metaphyseal cones at rTKA. Three cemented stem scenarios (no stem, 50 mm stem, and 100 mm stem) were investigated with 10 mm-deep uncontained posterior and medial tibial defects using four loading scenarios designed to mimic activities of daily living.


Bone & Joint Research
Vol. 7, Issue 10 | Pages 580 - 586
1 Oct 2018
Xie S Manda K Pankaj P

Aims

Loosening is a well-known complication in the fixation of fractures using devices such as locking plates or unilateral fixators. It is believed that high strains in the bone at the bone-screw interface can initiate loosening, which can result in infection, and further loosening. Here, we present a new theory of loosening of implants. The time-dependent response of bone subjected to loads results in interfacial deformations in the bone which accumulate with cyclical loading and thus accentuates loosening.

Methods

We used an ‘ideal’ bone-screw system, in which the screw is subjected to cyclical lateral loads and trabecular bone is modelled as non-linear viscoelastic and non-linear viscoelastic-viscoplastic material, based on recent experiments, which we conducted.