Armstrong R McKeever T McLelland C Hamilton D
Full Access

Abstract

Objective

There is no specific framework for the clinical management of sports related brachial plexus injuries. Necessarily, rehabilitation is based on injury presentation and clinical diagnostics but it is unclear what the underlying evidence base to inform rehabilitative management.

Methods

A systematic review of the literature was undertaken in line with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. We applied the PEO criteria to inform our search strategy to find articles that reported the rehabilitative management of brachial plexus injuries sustained while playing contact sports. An electronic search of Medline, CINAHL, SPORTDiscus and Web of Science from inception to 3rd November 2022 was conducted. MESH terms and Boolean operators were employed. We applied an English language restriction but no other filters. Manual searches of Google Scholar and citation searching of included manuscripts were also completed. All study types were considered for inclusion provided they were published as peer-reviewed primary research articles and contained relevant information. Two investigators independently carried out the searches, screened by title, abstract and full text. Two researchers independently extracted the data from included articles. Data was cross-checked by a third researcher to ensure consistency. To assess internal validity and risk of bias, the Joanna Briggs Institute (JBI) critical appraisal tools were utilised.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 12 - 12
17 Nov 2023
Cowan G Hamilton D
Full Access

Abstract

Objective

Meta-analysis of clinical trials highlights that non-operative management of degenerative knee meniscal tears is as effective as surgical management. Surgical guidelines though support arthroscopic partial meniscectomy which remains common in NHS practice. Physiotherapists are playing an increasing role in triage of such patients though it is unclear how this influences clinical management and patient outcomes.

Methods

A 1-year cohort (July 2019–June 2020) of patients presenting with MRI confirmed degenerative meniscal tears to a regional orthopaedic referral centre (3× ESP physiotherapists) was identified. Initial clinical management was obtained from medical records alongside subsequent secondary care management and routinely collected outcome scores in the following 2-years. Management options included referral for surgery, conservative (steroid injection and rehabilitation), and no active treatment. Outcome scores collected at 1- and 2-years included the Forgotten Joint Score-12 (FJS-12) questionnaire and 0–10 numerical rating scales for worst and average pain. Treatment allocation is presented as absolute and proportional figures. Change in outcomes across the cohort was evaluated with repeated measures ANOVA, with Bonferroni correction for multiple testing, and post-hoc Tukey pair-wise comparisons. As treatment decision is discrete, no direct contrast is made between outcomes of differing interventions but additional explorative outcome change over time evaluated by group. Significance was accepted at p=0.05 and effect size as per Cohen's values.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 1 - 1
7 Jun 2023
Gaston P Clement N Ohly N Macpherson G Hamilton D
Full Access

In this RCT the primary aim was to assess whether a short (125mm) Exeter V40 stem offered an equivalent hip specific function compared to the standard (150mm) stem when used for cemented total hip arthroplasty (THA). Secondary aims were to evaluate health-related quality of life (HRQoL), patient satisfaction, stem height and alignment, radiographic loosening, and complications between the two stems.

A prospective multicentre double-blind randomised control trial was conducted. During a 15-month period, 220 patients undergoing THA were randomised to either a standard (n=110) or short (n=110) stem Exeter. There were no significant (p≥0.065) differences in preoperative variables between the groups. Functional outcomes and radiographic assessment were undertaken at 1- and 2-years.

There were no differences (p=0.428) in hip specific function according to the Oxford hip score at 1-year (primary endpoint) or at 2-years (p=0.767) between the groups. The short stem group had greater varus angulation (0.9 degrees, p=0.003) when compared to the standard group and were more likely (odds ratio 2.42, p=0.002) to have varus stem alignment beyond one standard deviation from the mean. There were no significant (p≥0.083) differences in the Forgotten joint scores, EuroQol-5-Dimension, EuroQol-VAS, Short form 12, patient satisfaction, complications, stem height or radiolucent zones at 1 or 2-years between the groups.

The Exeter short stem offers equivalent hip specific function, HRQoL, patient satisfaction, and limb length when compared to the standard stem at 2-years post-operation. However, the short stem was associated with a greater rate of varus malalignment which may influence future implant survival.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 20 - 20
11 Apr 2023
Hamilton R Holt C Hamilton D Garcia A Graham C Jones R Shilabeer D Kuiper J Sparkes V Khot S Mason D
Full Access

Mechanical loading of joints with osteoarthritis (OA) results in pain-related functional impairment, altered joint mechanics and physiological nociceptor interactions leading to an experience of pain. However, the current tools to measure this are largely patient reported subjective impressions of a nociceptive impact. A direct measure of nociception may offer a more objective indicator. Specifically, movement-induced physiological responses to nociception may offer a useful way to monitor knee OA. In this study, we gathered preliminary data on healthy volunteers to analyse whether integrated biomechanical and physiological sensor datasets could display linked and quantifiable information to a nociceptive stimulus.

Following ethical approval, 15 healthy volunteers completed 5 movement and stationary activities in 2 conditions; a control setting and then repeated with an applied quantified thermal pain stimulus to their right knee. An inertial measurement unit (IMU) and an electromyography (EMG) lower body marker set were tested and integrated with ground reaction force (GRF) data collection. Galvanic skin response electrodes for skin temperature and conductivity and photoplethysmography (PPG) sensors were manually timestamped to the integrated system.

Pilot data showed EMG, GRF and IMU fluctuations within 0.5 seconds of each other in response to a thermal trigger. Preliminary analysis on the 15 participants tested has shown skin conductance, PPG, EMG, GRFs, joint angles and kinematics with varying increases and fluctuations during the thermal condition in comparison to the control condition.

Preliminary results suggest physiological and biomechanical data outputs can be linked and identified in response to a defined nociceptive stimulus. Study data is currently founded on healthy volunteers as a proof-of-concept. Further exploratory statistical and sensor readout pattern analysis, alongside early and late-stage OA patient data collection, can provide the information for potential development of wearable nociceptive sensors to measure disease progression and treatment effectiveness.


Abstract

Design

A pragmatic, multicentre, parallel-group, randomised controlled trial to determine whether the intervention is superior to comparator

Setting

20 NHS Hospitals


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 532 - 540
2 May 2022
Martin H Robinson PG Maempel JF Hamilton D Gaston P Safran MR Murray IR

There has been a marked increase in the number of hip arthroscopies performed over the past 16 years, primarily in the management of femoroacetabular impingement (FAI). Insights into the pathoanatomy of FAI, and high-level evidence supporting the clinical effectiveness of arthroscopy in the management of FAI, have fuelled this trend. Arthroscopic management of labral tears with repair may have superior results compared with debridement, and there is now emerging evidence to support reconstructive options where repair is not possible. In situations where an interportal capsulotomy is performed to facilitate access, data now support closure of the capsule in selective cases where there is an increased risk of postoperative instability. Preoperative planning is an integral component of bony corrective surgery in FAI, and this has evolved to include computer-planned resection. However, the benefit of this remains controversial. Hip instability is now widely accepted, and diagnostic criteria and treatment are becoming increasingly refined. Instability can also be present with FAI or develop as a result of FAI treatment. In this annotation, we outline major current controversies relating to decision-making in hip arthroscopy for FAI.

Cite this article: Bone Joint J 2022;104-B(5):532–540.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 19 - 19
1 Dec 2021
Brzeszczynski F Brzeszczynska J Murray I Duckworth A Simpson H Hamilton D
Full Access

Abstract

Objectives

Sarcopenia is characterised by generalised progressive loss of physical performance, skeletal muscle mass and strength. This systematic review evaluated the effects of sarcopenia on postoperative functional recovery outcomes and mortality in patients undergoing orthopaedic surgery and secondarily assessed the methods used to diagnose and define sarcopenia in orthopaedic literature.

Methods

A systematic search was conducted in MEDLINE, EMBASE and Google Scholar databases according to the PRISMA guidelines. Studies involving sarcopenic patients who underwent defined orthopaedic surgery and recorded postoperative outcomes were included. The quality of the criteria by which a sarcopenia diagnosis was made was evaluated and publication quality was assessed using Newcastle-Ottawa Scale.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 64 - 64
1 Dec 2021
Hamilton R Holt C Hamilton D Jones R Shillabeer D Kuiper JH Sparkes V Mason D
Full Access

Abstract

Objectives

Current tools to measure pain are broadly subjective impressions of the impact of the nociceptive impulse felt by the patient. A direct measure of nociception may offer a more objective indicator. Specifically, movement-induced physiological responses to nociception may offer a useful way to monitor knee OA. In this proof-of-concept study, we evaluated whether integrated biomechanical and physiological sensor datasets could display linked and quantifiable information to a nociceptive stimulus.

Method

Following ethical approval, we applied a quantified thermal pain stimulus to a volunteer during stationary standing in a gait lab setting. An inertial measurement unit (IMU) and an electromyography (EMG) lower body marker set were tested and integrated with ground reaction force (GRF) data collection. Galvanic skin response electrodes and skin thermal sensors were manually timestamp linked to the integrated system.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 58 - 58
1 Jul 2020
Hamilton D Simpson H Beard D Barker K MacFarlane G Stoddart A Murray G
Full Access

There is a lack of evidence as to the best way to deliver rehabilitation following TKA. Previous work has suggested that postoperative physiotherapy applied to all patients is not effective at improving one-year post-surgical outcomes. The aim of this study was to target physiotherapy to those at risk of poor outcome following TKA, and to determine if a therapist-led intervention offered superior results compared to a home-exercise based protocol in this ‘at risk’ group.

The Targeted Rehabilitation to Improve Outcomes (TRIO) study was a prospective randomised controlled trial run at 15-centres in the UK. Patients were identified as ‘potential poor outcome’ based on an Oxford Knee Score (OKS) classification at 6-weeks post-surgery and randomised to either therapist-led or home-exercise based protocols. Patients were reviewed by a physiotherapist and commenced 18-exercise sessions over 6-weeks. The therapist-led group undertook a progressive functional protocol (modified weekly in 1-1 contact sessions) in contrast to the static home-exercise based regime. Evaluation took place following rehabilitation intervention, then at 6-months and 1-year post-surgery. Primary outcome was comparative group OKS at 1-year. Secondary outcomes included, ‘worst’ and ‘average’ pain scores, OXS and EQ-5D, and satisfaction questionnaire. Health economic (cost-utility) analysis was undertaken from NHS perspective up to 1-year post-surgery. Incremental cost per Quality Adjusted Life Years (QALYs) were calculated from intervention costs, patient reported primary and secondary care usage, and EQ-5D data.

4264 patients were screened, 1296 were eligible, 334 patients were randomised, 8 were lost to follow-up, therapy compliance was >85%. Clinically meaningful improvement in OKS (between baseline and 1-year) was seen in both arms (p < 0 .001). Between group difference in 1-year OKS was 1.91 (95%CI, −0.17–3.99) points favouring the therapist-led arm (p=0.07). Incorporating all time point data, between group difference in OKS was 2.25 points (95%CI, 0.61–3.90, p=0.008). Small, non-significant reductions (< 5 %) in both worst and average pain scores were observed favouring the therapist-led group. Enhanced satisfaction with pain relief (OR 1.65, p < 0 .02), ability to perform daily functional tasks (OR 1.66, p < 0 .02), and perform heavy functional tasks (OR 1.6, p=0.04) was reported in the therapist-led group. There was a small non-significant difference of 0.02 points (95%CI −0.02–0.06) between groups in EQ-5D, resulting in a £12,125 cost per QALY of delivering the therapist led intervention with a 57% chance of being cost-effective at the standard UK policy threshold of £20,000 per QALY.

TRIO is the largest randomised trial of physiotherapy following TKA, and the first to target rehabilitation to patients at risk of poor outcomes. Both therapist-led and home-exercise based rehabilitation groups made clinically meaningful improvements in outcome by 1-year. We observed a modest difference in OKS in favour of therapist-led rehabilitation compared to the home-exercises which was not statistically significant. The relatively tight confidence intervals suggests that any difference which might exist is too small to be clinically relevant. Patient satisfaction with outcome was however higher in those that received greater physiotherapist contact. While cost per QALY estimates were below UK policy threshold, this result is uncertain and insufficient to make accept-decline recommendations.


Bone & Joint Research
Vol. 9, Issue 4 | Pages 162 - 172
1 Apr 2020
Xie S Conlisk N Hamilton D Scott C Burnett R Pankaj P

Aims

Metaphyseal tritanium cones can be used to manage the tibial bone loss commonly encountered at revision total knee arthroplasty (rTKA). Tibial stems provide additional fixation and are generally used in combination with cones. The aim of this study was to examine the role of the stems in the overall stability of tibial implants when metaphyseal cones are used for rTKA.

Methods

This computational study investigates whether stems are required to augment metaphyseal cones at rTKA. Three cemented stem scenarios (no stem, 50 mm stem, and 100 mm stem) were investigated with 10 mm-deep uncontained posterior and medial tibial defects using four loading scenarios designed to mimic activities of daily living.


The Bone & Joint Journal
Vol. 101-B, Issue 7 | Pages 838 - 847
1 Jul 2019
Robinson PG Clement ND Hamilton D Blyth MJG Haddad FS Patton JT

Aims

Robotic-assisted unicompartmental knee arthroplasty (UKA) promises accurate implant placement with the potential of improved survival and functional outcomes. The aim of this study was to present the current evidence for robotic-assisted UKA and describe the outcome in terms of implant positioning, range of movement (ROM), function and survival, and the types of robot and implants that are currently used.

Materials and Methods

A search of PubMed and Medline was performed in October 2018 in line with the Preferred Reporting Items for Systematic Review and Meta-Analysis statement. Search terms included “robotic”, “knee”, and “surgery”. The criteria for inclusion was any study describing the use of robotic UKA and reporting implant positioning, ROM, function, and survival for clinical, cadaveric, or dry bone studies.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_2 | Pages 34 - 34
1 Jan 2019
Sehgal A Burnett R Howie C Simpson H Hamilton D
Full Access

Instability accounts for approximately 20% of revision total knee arthroplasty (TKA) operations, however, diagnostic tests remain relatively subjective. The aim of this examination was to evaluate the feasibility of using pressure mat analyses during functional tasks to identify abnormal biomechanics associated with TKA instability.

Five patients (M = 4; age = 69.80±7.05 years; weight = 79.73±20.12 kg) with suspected TKA instability were examined compared to 10 healthy controls (M = 4; age = 44.6±7.52 years; weight = 70.80±14.65). Peak pressure and time parameters were measured during normal gait and two-minute bilateral stance. Side-to-side pressure distribution was calculated over 10-second intervals during the second minute. Mann-Whitney tests compared loading parameters between groups and side-to-side differences in TKA patients (significance level = p<0.05).

Pressure distribution was expressed relative to bodyweight. Notable differences were seen during bilateral stance. Uneven side loading was greater – favouring the non-operated limb – in TKA patients during bilateral stance compared to controls. This was significantly different at 30s (p=0.0336) and 60s (p=0.0336). Gait analyses showed subtle pressure distribution differences in unstable TKA patients. Stance time was indifferent. TKA patients tended to exhibit longer heel contact time (0.76s vs. 0.64s and reduced weight acceptance (50.75% vs. 56.75%) on the operated limb compared to the non-operated limb. Side-to-side differences in peak toe-off forces were significantly more pronounced in TKA patients versus controls (9.25% +/− 1.5% vs. 1.67% +/−5.79%; p=0.0039).

Conclusion: This feasibility work demonstrates subtle differences in limb loading mechanics during simple clinical tests in unstable TKA patients that might be invisible to the naked eye. In the long-term, pressure analyses may be a useful diagnostic tool in identifying patients that would benefit from revision surgery for TKA instability.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 6 - 6
1 Nov 2018
Hamilton D
Full Access

Physiotherapy is generally accepted as an important component in the care pathway surrounding total knee replacement. Therapy interventions can be delivered prior to surgery, as part of the inpatient stay, and post-operation through outpatient appointments. Though ‘physiotherapy’ is generally promoted there is considerable national and international variation in actual therapy provision. Specific rehabilitation protocols are strongly entrenched at individual physiotherapy departments however the wider efficacy of varying physiotherapeutic interventions is poorly established. This uncertainty as to effectiveness of physiotherapy makes it difficult for commissioning organisations, healthcare providers, and patients to make decisions as to what therapy is ‘needed’ and therefore the correct level and mechanism of funding for such services. This talk will explore the variation in physiotherapy service provision and evidence for different interventions surrounding total knee replacement.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 88 - 88
1 Nov 2018
Griffin MTA Simpson A Hamilton D
Full Access

The first three months following Total Knee Arthroplasty (TKA) provide an early window into a patient's functional outcomes, with the change of function in this time yielding valuable insight.

20 patients due to undergo primary TKA were recruited to the study. Data were recorded at three time points; pre-assessment clinic (PAC) before the operation, 6-weeks-post-operation (6WKs), at 12-weeks-post-operation (12WKs). Functional activity levels were monitored during early post-operative recovery for changes in early functional outcome, and allowed a comparison of metrics at each time point. This included direct functional testing of power output, timed functional performance in clinic, patient reported outcome measures, and multiday activity monitoring devices. Maximal power output symmetry (Power) was similar at 6WKs vs PAC (p = 0.37). At 12WKs, it had increased (p < 0.05). Timed functional performance (Performance) remained similar across all three time points (p = 0.27). Patient reported activities of daily living (ADL) performance significantly increased at 6WKs vs PAC (p < 0.05). At 12WKs, it remained similar (p = 0.10). Patient daily step count significantly decreased at 6WKs vs PAC (p < 0.05). By 12WKs, this had increased to similar levels to PAC (p = 0.30). Within the functional outcome measures, strong post-operative correlations were observed between Power and Performance (r = 0.62), Power and ADL (r = 0.49), and Performance and ADL (r = 0.61). Despite reduced measured step count and similar functional performance, patients report improved ADL at 6WKs. When symmetrical power output and measured step count have improved at 12WKs, patients report similar ADL to that at 6WKs. Multiple measures are required to get a full picture, however this highlights the different aspects measured by different tools.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 65 - 65
1 Nov 2018
Sehgal A Burnett R Howie C Simpson H Hamilton D
Full Access

Instability accounts for approximately 20% of all revision total knee arthroplasty (TKA), however diagnostic tests remain crude and subjective. The aim of this examination was to evaluate the feasibility of pressure mat (SB Mat, TekScan) analyses of functional tasks to differentiate instability in a clinical setting. Five patients (M = 4; age = 69.80±7.05 years; weight = 79.73±20.12 kg) with suspected TKA instability were examined compared to five healthy controls (M = 1; age = 46.80±7.85 years; weight = 71.54±16.17 kg). Peak pressure and time parameters were measured during normal gait and two-minute bilateral stance. Side-to-side pressure distribution was calculated over 10-second intervals during the second minute. Pressure distributions were expressed relative to bodyweight (%BW). T-tests compared loading parameters between groups (significance level = p<0.05). Analyses showed subtle differences in pressure distribution in unstable TKA patients versus healthy controls. Stance time during gait was indifferent. TKA patients tended to exhibit longer heel contact time (0.76 vs. 0.64 sec) and reduced weight acceptance (50.75% vs. 56.75%) on the operated versus non-operated limb. Side-to-side differences in toe-off forces were significantly more pronounced in TKA patients versus controls (9.25% vs. 3.75%; p=0.0088). Uneven loading was significantly greater – favouring the non-operated limb – in TKA patients during bilateral stance compared to controls (p<0.05). This feasibility work demonstrates subtle differences in limb loading and biomechanics during simple clinical tests in unstable TKA patients that might be undetectable to the naked eye. Pressure analyses may therefore be a useful diagnostic tool. These findings warrant further investigation.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 13 - 13
1 Apr 2018
Giesinger J Loth F McDonald D Giesinger K Patton J Simpson H Howie C Hamilton D
Full Access

Aim

To investigate the validity of threshold values for the Oxford Hip and Knee Score (OHS and OKS) for treatment success 12 months after total knee or hip replacement.

Methods

Questionnaires were administered to patients undergoing total hip (THA) or knee (TKA) replacement before and 12 months after surgery alongside questions assessing key accepted aspects of treatment success (satisfaction, pain relief, functional improvement) to form a composite criterion of success and assessed using receiver operator characteristic (ROC) analysis. Thresholds providing maximum sensitivity and specificity for predicting treatment success were determined for the total sample and subgroups defined by pre-surgery scores.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_3 | Pages 2 - 2
1 Apr 2018
Hamilton D Loth F MacDonald D Giesinger K Patton J Simpson H Howie C Giesinger J
Full Access

Aim

To evaluate the association of BMI and improvement in patient-reported outcomes after TKA.

Methods

Knee replacement outcome data for procedures carried out over an eight month period was extracted from a regional arthroplasty register in the UK. Data was available before surgery and 12 months after. We analysed the impact of overweight on post-operative change in the Forgotten Joint Score − 12 (FJS-12) measuring joint awareness and the Oxford Knee Score (OKS) measuring pain and function using five BMI categories (A: <25, B: 25–29.9, C: 30–34.9, D: 35–39.9 and E: >40).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 43 - 43
1 Oct 2016
Hamilton D Giesinger K Giesinger J Loth F Simpson A Howie C
Full Access

Obese patients undergoing total knee arthroplasty (TKA) face increased risks of complications such as joint infection and early revision. However, the influence of obesity on measures of patient function following TKA is poorly defined.

Knee arthroplasty outcome data for procedures carried out over an eight month period was extracted from a regional database in the UK. We analysed the impact of weight categories (BMI<30, BMI=30–34.9, and BMI≥35) on the Forgotten Joint Score – 12 (FJS-12) and Oxford Knee Score (OKS). Data was available preoperatively and 12 months postoperatively. Physical and mental health was assessed with the SF-12 one year after surgery.

Data from 256 patients were available. 49.6% had a BMI<30, 27.4% had a BMI 30–34.9 and 23.1% had a BMI≥35. Mean FJS-12 results at 1-year were 48.7 points for patients with a BMI<30, 40.7 points for patients with a BMI=30–34.9 and 34.0 points for patients with a BMI≥35. Effect sizes for change from baseline to 12-month post-op were 3.0 (Cohen's d) in patients with BMI<30 and d=2.2 in patients with BMI≥35. Mean OKS results at 1 year were 36.9 (BMI<30), 33.7 (BMI=30–34.9) and 32.0 (BMI≥35) respectively. Effect sizes for change from baseline to 12-month was d=2.1 (BMI<30) and d=1.9 (BMI≥35). Differences between BMI groups with regard to post-operative change were statistically significant for the FJS-12 (p=0.038) but not for the OKS (p=0.229).

This study highlights that outcome scores may differ in their ability to capture the impact of obesity on patient function following TKA. The FJS-12 showed significant differences in outcome based on patient obesity category, whereas the OKS did not detect between group differences.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 32 - 32
1 Oct 2016
Hamilton D Gaston P Simpson A
Full Access

Physical outcome following total knee arthroplasty is variable. Satellite cells are undifferentiated myogenic precursors considered to be muscle stem cells. We hypothesised that; the recovery of muscle strength and physical function following knee arthroplasty would be influenced by the underlying number of muscle satellite cells.

16 patients provided a distal quadriceps muscle biopsy at time of surgery. Satellite cells were identified with a primary mouse antibody for Pax7 – a cytoplasmic protein marker, and the myonuclei with DAPI. Positive cells were identified on the basis of immunofluorescent staining in association with nuclear material, and confirmed by position under the basal lamina. Patient function was assessed using a validated physical assessment protocol, the Aggregated Locomotor Function (ALF) score, muscle strength assessed using the leg extensor power-rig, and clinical outcome assessed with the Oxford Knee Score (OKS) pre-operatively and at 1 year post operatively.

Muscle satellite cell content varied amongst the patient group (Positive Staining Index 3.1 to 11.4). Satellite cell content at time of surgery correlated with change in outcomes between pre-operative and 1 year assessments in all assessed parameters (ALF, r = 0.31; muscle power, r = 49; OKS, r = 0.33). Regression analysis employing a forward stepwise selection technique employed satellite cell volume in models of pre-operative to 1 year change for all outcome parameters. Physical function (satellite cell content, patient age and pre-operative ALF score) adjusted R2 = 0.92; Muscle power (pre-operative power and satellite cell content) adjusted R2 = 0.38; Clinical outcome (pre-operative OKS and satellite cell content) adjusted R2 = 0.28.

Muscle satellite cell content influences recovery of muscle power and physical function following total knee arthroplasty. Importantly it is also associated with change in clinical scores; suggesting it to be a biomarker for patient outcomes.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 19 - 19
1 Oct 2016
Griffin M Annan J Hamilton D Simpson A
Full Access

3D imaging is commonly employed in the surgical planning and management of bony deformity. The advent of desktop 3D printing now allows rapid in-house production of specific anatomical models to facilitate surgical planning. The aim of this pilot study was to evaluate the feasibility of creating 3D printed models in a university hospital setting.

For requested cases of interest, CT DICOM images on the local NHS Picture Archive System were anonymised and transferred. Images were then segmented into 3D models of the bones, cleaned to remove artefacts, and orientated for printing with preservation of the regions of interest. The models were printed in polylactic acid (PLA), a biodegradable thermoplastic, on the CubeX Duo 3D printer.

PLA models were produced for 4 clinical cases; a complex forearm deformity as a result of malunited childhood fracture, a pelvic discontinuity with severe acetabular deficiency following explantation of an infected total hip replacement, a chronically dislocated radial head causing complex elbow deformity as a result of a severe skeletal dysplasia, and a preoperative model of a deficient proximal tibia as a result of a severe tibia fracture. The models materially influenced clinical decision making, surgical intervention planning and required equipment. In the case of forearm an articulating model was constructed allowing the site of impingement between radius and ulnar to be identified, an osteotomy was practiced on multiple models allowing elimination of the block to supination. This has not previously been described in literature. The acetabulum model allowed pre-contouring of a posterior column plate which was then sterilised and eliminated a time consuming intraoperative step.

While once specialist and expensive, in house 3D printing is now economically viable and a helpful tool in the management of complex patients.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_16 | Pages 40 - 40
1 Oct 2016
Hamilton D Simpson P Patton J Howie C Burnett R
Full Access

Patient function is poorly characterised following revision TKA. Modern semi-constrained implants are suggested to offer high levels of function, however, data is lacking to justify this claim.

52 consecutive aseptic revision TKA procedures performed at a single centre were prospectively evaluated; all were revision of a primary implant to a Triathlon total stabiliser prosthesis. Patients were assessed pre-operatively and at 6, 26, 52 and 104 weeks post-op. Outcome assessments were the Oxford Knee Score (OKS), range of motion, pain rating scale and timed functional assessment battery. Analysis was by repeated measures ANOVA with post-hoc Tukey HSD 95% simultaneous confidence intervals as pairwise comparison. Secondary analysis compared the results of this revision cohort to previously reported primary TKA data, performed by the same surgeons, with identical outcome assessments at equivalent time points.

Mean age was 73.23 (SD 10.41) years, 57% were male. Mean time since index surgery was 9.03 (SD 5.6) years. 3 patients were lost to follow-up. All outcome parameters improved significantly over time (p <0.001). Post-hoc analysis demonstrated that all outcomes changed between pre-op, 6 week and 26 weeks post-op assessments.

No difference was seen between primary and revision cohorts in OKS (p = 0.2) or pain scores (p=0.19). Range of motion and functional performance was different between groups over the 2 year period (p=0.03), however this was due to differing pre-operative scores, post-hoc analysis showed no difference between groups at any post-operative time point.

Patients undergoing aseptic revision TKA with semi-constrained implants made substantial improvements in OKS, pain scores, knee flexion, and timed functional performance, with the outcomes achieved comparable to those of primary TKA. High levels of function can be achieved following revision knee arthroplasty, which may be important considering the changing need for, and demographics of, revision surgery.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 29 - 29
1 Jul 2014
Hamilton D Lane J Gaston P Patton J MacDonald D Simpson H Howie C
Full Access

Summary Statement

Service industry metrics (the net promoter score) are being introduced as a measure of UK healthcare satisfaction. Lower limb arthroplasty, as a ‘service’, scores comparably with the most successful commercial organisations.

Background

Satisfaction with care is important to both the patient and the payer. The Net Promoter Score, widely used in the service industry, has been recently introduced to the UK National Health Service as an overarching metric of patient satisfaction and to monitor performance. This questionnaire asks ‘customers’ if they would recommend a service or products to others. Scores range from −100 (everyone is a detractor) to +100 (everyone is a promoter). In industry, a positive score is well regarded, with those over 50 regarded as excellent. Our aims were to assess net promoter scores for joint arthroplasty, to compare these scores with direct measures of patient satisfaction, and to evaluate which factors contributed to net promoter response.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 30 - 30
1 Jul 2014
Hamilton D Clement N Patton J Burnett R Gaston P Howie C Simpson H
Full Access

Summary Statement

Using current analysis/methodology, new implant technology is unlikely to demonstrate a large enough change in patient function to impact on the cost-effectiveness of the procedure.

Purpose

Cost effectiveness is an increasingly important metric in today's healthcare environment, and decisions surrounding which arthroplasty prosthesis to implant are not exempt from such health economic concerns. Quality adjusted life years (QALYs) are the typical assessment tool for this type of evaluation. Using this methodology, joint arthroplasty has been shown to be cost effective, however studies directly comparing the QALY achieved by differing prostheses are lacking.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_13 | Pages 8 - 8
1 Mar 2013
Hamilton D Gaston P Simpson A
Full Access

INTRODUCTION

This study investigates the relationship between direct measurement of outcome and patient report of that outcome via the OKS. The stability of this relationship over time following surgery is also assessed.

METHODS

183 TKA patients were assessed pre-operatively and at 6, 26 and 52 weeks post-op. Oxford Knee Score was obtained along with measures of pain intensity, knee flexion, lower limb power and timed functional assessment. Correlation of performance variables with the OKS was assessed, and regression analysis performed on those that formed significant associations. Significance was accepted at p = 0.05.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_5 | Pages 8 - 8
1 Feb 2013
Jenkins PJ Clement N Hamilton D Patton J Simpson H Howie C
Full Access

The aim was to perform a cost-utility analysis of total joint replacement in the current environment.

Arthritis is a disabling condition that leads to long-term deterioration in quality of life. Total joint replacement, despite being one of the greatest advances in medicine in the modern era, has come under recent scrutiny. The National Health Service (NHS) has competing demands and resource allocation is challenging in times of economic restraint.

Patients undergoing total hip (n=348) and knee arthroplasty (n=323), from January to July 2010, were entered into a prospective arthroplasty database. A health utility score was derived from the Euroqol (EQ-5D) score preoperatively, and at one year, and was combined with individual life expectancy to derive the Quality-Adujusted-Life-Years (QALYs) gained. Predicted need for revision surgery was Incorporated in the model. The 2011–12 Scottish Tariff was used. Two-way analysis of variance was used to compare QALYs gained between procedures, while controlling for baseline differences.

The number of QALYs gained was higher in THR versus TKR (6.53 vs 4.04 years, p<0.001). The cost per QALY for THR was £1371 (95% CI £1194 to £1614) compared with £2101 (£1762 to £2620) for TKR. Predictors of an increase in QALYs gained were poorer health prior to surgery (p<0.001) and younger age (p<0.001). General health (EQ-5D VAS) showed greater improvement in THR versus TKR (p<0.001).

This study provides up to date cost-effectiveness data for total joint replacement. THR and TKR are both extremely clinically and cost-effective interventions, with costs that compare favourably with other medical interventions (e.g. laparoscopic hernia repair vs open: £55,548 per QALY; CHD primary prevention with statins: £21,000).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 72 - 72
1 Jan 2013
Hamilton D Gaston P Patton S Burnett R Howie C Simpson H
Full Access

Introduction

Many prosthetic design changes have been introduced in attempt to improve outcomes following TKA; however there is no consensus as to whether these changes confer benefits to patients. This study aimed to assess whether patients treated with a modern implant design had an enhanced patient outcome compared to a traditional model in a double blind randomised controlled trial.

Methods

212 consecutive patients were prospectively randomised to receive either a modern (Triathlon) or a traditional (Kinemax) TKA (both Stryker Orthopaedics). 6 surgeons at a single unit performed all procedures in a standardised manner. A single researcher, blinded to implant allocation, performed all assessments. Patients were assessed pre-operatively, and at 6, 26, 52 weeks post-surgery with the Oxford Knee Score (OKS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, goniometry, timed functional assessment, lower limb power (Leg Extensor Power Rig) and pain numerical rating scales (NRS). Change in scores and between group differences were assessed with Two-Way Repeated Measures ANOVAs.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 205 - 205
1 Sep 2012
Challagundla S Knox D Hawkins A Hamilton D Flynn R Robertson S Isles C
Full Access

Background

We switched our antibiotic prophylaxis for elective hip and knee surgery from cefuroxime to flucloxacillin with single dose gentamicin in order to reduce the incidence of C. Diff diarrhoea. More patients subsequently appeared to develop acute kidney injury (AKI).

Methods

During a twelve month period we examined the incidence of AKI sequentially in 198 patients undergoing elective hip or knee surgery: cefuroxime (n = 48); high dose flucloxacillin (median 8g) (n = 52); low dose flucloxacillin (median 4g) (n = 46); and cefuroxime again (n = 52).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVI | Pages 67 - 67
1 Aug 2012
Hamilton D Gaston P Simpson A
Full Access

End-stage osteoarthritis is characterised by pain and reduced physical function, for which total knee arthroplasty (TKA) is recognised to be a highly effective treatment. Most implants are multi radius in design, though modern kinematic theory suggests a single flexion/extension axis is located in the femur. A recently launched TKA implant (Triathlon, Stryker US), is based on this theory, adopting a single radius of curvature femoral component. It is hypothesised that this design allows better function, and specifically, that it results in enhanced efficiency of the quadriceps group through a longer patello-femoral moment arm.

Change in power output was compared between single and multi radius implants as part of a larger ongoing randomised controlled trial to benchmark the new implant. Power output was assessed using a Leg Extensor Power Rig, well validated for use with this population, pre-operatively and at 6, 26 and 52 weeks post-operatively in 101 Triathlon and 82 Kinemax implants. All patients were diagnosed with osteoarthritis, and drawn from a single centre. Output was reported as maximal wattage (W) generated in a single leg extension, and expressed as a proportion of the contralateral limb power output to act as an internal control.

The results are shown in the table below. Two-way repeated measures ANOVA demonstrated a significant effect of TKA on the quadriceps power output, F = 249.09, p = <0.001 and also a significant interaction of the implant group on the output F = 11.33, p = 0.001. Independent samples t-tests of between group differences at the four assessment periods highlighted greater improvement in the single radius TKA group at all post-operative assessments (p <0.03), see table.

The theoretical enhanced quadriceps efficiency conferred by single radius design was found in this study. Power output was significantly greater at all post-operative assessments in the single radius compared to the multi radius group. This difference was particularly relevant at early 6 week and 1 year assessment. Lower limb power output is known to link positively to functional ability. The results support the hypothesis that TKAs with a single radius design have enhanced recovery and better function.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIII | Pages 8 - 8
1 Jul 2012
Challangundla R Knox D Hawkins A Hamilton D Flynn R Isles C
Full Access

SIGN guidelines advise the use of flucloxacillin and gentamicin instead of cefuroxime as antibiotic prophylaxis for elective hip and knee arthroplasty. It is our impression that this change in practice has been associated with an increased risk of acute kidney injury (AKI).

During a twelve month period we examined the incidence of AKI sequentially in four groups of patients: cefuroxime prophylaxis (n = 46); high dose flucloxacillin (5-8g) with single shot gentamicin (n = 50); low dose flucloxacillin (1-4 g) with single shot gentamicin (n = 45); and finally cefuroxime again (n = 52).

There were no statistically significant differences by chi-square tests for age, gender, operation (hip or knee), ASA, anaesthesia, baseline serum creatinine, hypertension, diabetes or pre-operative medication. The proportion of patients in each antibiotic group with any form of AKI by RIFLE criteria was: cefuroxime group 1 (9%), high dose flucloxacillin (52%), low dose flucloxacillin (22%), cefuroxime 2 (14%) (p < 0.0001 by chi-square test). Odds ratios (OR) for AKI derived from a multivariate logistic regression model and assigning an OR of 1 to cefuroxime group 1 was: high dose flucloxacillin 14.5 (95% CI, 4.2, 50.2); low dose flucloxacillin 3.0 (0.8-10.9) and cefuroxime group 2 1.9 (0.5, 7.4). Three patients in the high dose flucloxacillin group required temporary haemodialysis.

We have shown a strong association between high dose prophylactic flucloxacillin and subsequent development of AKI. We have no reason to believe that this was confounded by any of the co-variates we measured.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 22 - 22
1 May 2012
Hamilton D Gaston P Simpson A
Full Access

Introduction

Recovery of muscle strength following Total Knee Replacement (TKR) is variable, and can affect the resultant function of the patient. Satellite cells are undifferentiated myogenic precursors considered to be muscle stem cells that lie quiescently around the muscle fibre. These cells repair damaged fibres and have the potential to generate new muscle fibres. Therefore, theoretically, they could be associated with the variation in muscle recovery following surgery. We hypothesised that the recovery of muscle strength following knee replacement in a given patient would be influenced by the underlying number of satellite cells in that patient.

Methods

20 patients undergoing TKR were recruited from the waiting list of a single consultant. A muscle biopsy was taken at the time of surgery from the distal quadriceps. This was fixed in paraffin wax, and sections obtained. Satellite cells were identified with a primary mouse antibody for Pax7 - a cytoplasmic protein marker - and an immunofluorescent goat anti-mouse secondary. Slides were counterstained with DAPI to stain the myonuclei. The positive staining index (PSI) was calculated (number of satellite cells/total number of myonuclei x 100). Recovery of muscle (quadriceps) strength was assessed using the leg extensor power-rig (LegRig) pre-operatively, at 6 and 26 weeks post-operatively. Statistical analysis was performed using the Minitab version 15 software, the level of significance was set as p = 0.05.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 76 - 76
1 Mar 2012
Tsiridis E Gamie Z Upadhyay N George M Hamilton-Baillie D Giannoudis P
Full Access

Surgery for pelvic or acetabular fractures carries a high risk of deep-vein thrombosis (DVT). Reports indicate that fondaparinux is a more effective thromboprophylactic agent than low molecular weight heparin (LMWH) after major orthopaedic surgery. We prospectively evaluated a new protocol for DVT prophylaxis using fondaparinux.

Patients and methods

One hundred and eight patients with pelvic or acetabular fractures were randomised to receive either fondaparinux or enoxaparin. Specific review points included the primary end-point of clinical deep vein thrombosis (DVT) or pulmonary embolism (PE) and any evidence of adverse effects such as bleeding or allergic reactions.

Results

Two patients that received enoxaparin were found to have a DVT (3%) and one patient died from a PE (1%). There was no documented DVT or PE in patients that received fondaparinux. The mean number of units of blood transfused was significantly higher in the enoxaparin group and this was significant post-operatively (p<0.05). The current study supports that post-operative fondaparinux, in patients with pelvic and acetabular fractures, is more effective and equally safe to enoxaparin.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 3 | Pages 414 - 417
1 Mar 2011
Knox D Murray G Millar M Hamilton D Connor M Ferdinand RD Jones GA

Anthrax is extremely rare in the western world but is endemic to areas of south and central Asia. In early 2010 an outbreak was identified in heroin-injecting intravenous drug users in the United Kingdom and Europe. Afghanistan is currently the principal source of heroin which reaches the United Kingdom. When anthrax occurs, cutaneous disease accounts for over 95% of cases. At least 47 cases with 13 deaths have been confirmed so far. We present three cases presenting during this time with marked swelling, one resulting in compartment syndrome but all with an absence of the expected cutaneous appearances.

We suggest that rather than cutaneous anthrax, these patients represent a new subcutaneous presentation of anthrax.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 368 - 368
1 May 2009
Anwar M Khalid M Hamilton D Searle R Sundar M
Full Access

Introduction: Arthrodesis of 1st MTPJ is performed using various fixation techniques including lag screws, dorsal plate and screws, K-wiring. We evaluated the strength of fixation using two staples placed at right angles.

Methods: Ten pairs of cadaveric feet were dissected to harvest the hallux MTPJ. Planar cut of articular surfaces using a micro-saggital saw. The bony ends were then approximated with an intervening blade and fixed using 2 staples placed at right angles. The specimen was supported on either ends and subjected to 3 point loading using a materials testing machine (Instron). The load at which the joint opened up sufficiently to let the blade fall was recorded. The load at which the construct failed was then recorded

Results: The joint opened up at an average of 41 Newtons. The load to failure was 130 Newtons. The corresponding average values in kilograms were 4.19 kilograms for the opening of the joint and 12.61 kilograms for the failure of the construct. On full weight bearing using the heel weight bearing shoes that we normally use post-operatively, the forces going through the forefoot were 0 newtons/kilograms, calculated using a TEK SCAN (measures the foot pressure on walking)

Conclusion: It is safe to walk patients using a heel weight bearing shoe (Benefoot post op wedge shoe) following 1st MTPJ fusion using staples (uniclip-NewDeal). This is a major advantage compared to other methods of fixation that require plaster cast immobilisation thus reducing inconvenience, plaster expenses and possible complications like DVT.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 25 - 25
1 Mar 2009
Tsiridis E George M Hamilton-Baillie D Gamie Z Upadhyay N Giannoudis P
Full Access

Without thromboprophalaxis, the recorded incidence of deep venous thrombosis (DVT) in pelvic fracture varies between 35% and 61%. The incidence of pulmonary embolism (PE) is reported to be 2–10% and death subsequently occurs in 0.5–4% of patients. With preventative measures the incidence of clinically significant DVT has been reported as low as 0.5%. The primary aim of this study is to look into the efficacy of Enoxaparin in preventing clinically significant DVT and PE in patients with pelvic and acetabular fracture. The secondary aim is to investigate the effect of prolonged pre-operative exposure to Enoxaparin on operative and post-operative bleeding. Sixty-four patients with pelvic and acetabular fractures were reviewed retrospectively between 2000–2005. Patients with coagulopathies were excluded. 40mg Enoxaparin was administered daily following haemodynamic evaluation and continued thereafter until discharge. Blood loss was measured using 3 indicators: volume of blood transfused, difference in pre and post operative Hb, and amount of blood collected in surgical drains. The incidence of clinically significant DVT was 2.9% (2 cases). There was no confirmed incidence of PE. 47% of patients were operated on within a week of admission (Group A), 40% within 1–2 weeks (Group B) and 13% in over 2 weeks (Group C). The group with the most prolonged pre-operative exposure to Enoxaparin: Group C, required the least transfused blood (A: 4.8units, B: 2.0units C: 1.3units), bled the least into drains (A:310ml, B:253ml and C:212ml) and had the smallest post-operative fall in Hb (A:2.2, B:2.0, C:1.9). The low incidence of clinically detectable DVT in the study confirms that Enoxaparin is an effective method for reducing the incidence of significant thrombotic events. Prolonged pre-operative administration of Enoxaparin does not pre-dispose patients to an increased risk of operative and post-operative bleeding.