header advert
Results 1 - 34 of 34
Results per page:
The Bone & Joint Journal
Vol. 104-B, Issue 8 | Pages 929 - 937
1 Aug 2022
Gurung B Liu P Harris PDR Sagi A Field RE Sochart DH Tucker K Asopa V

Aims

Total hip arthroplasty (THA) and total knee arthroplasty (TKA) are common orthopaedic procedures requiring postoperative radiographs to confirm implant positioning and identify complications. Artificial intelligence (AI)-based image analysis has the potential to automate this postoperative surveillance. The aim of this study was to prepare a scoping review to investigate how AI is being used in the analysis of radiographs following THA and TKA, and how accurate these tools are.

Methods

The Embase, MEDLINE, and PubMed libraries were systematically searched to identify relevant articles. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for scoping reviews and Arksey and O’Malley framework were followed. Study quality was assessed using a modified Methodological Index for Non-Randomized Studies tool. AI performance was reported using either the area under the curve (AUC) or accuracy.


The Bone & Joint Journal
Vol. 102-B, Issue 11 | Pages 1519 - 1526
2 Nov 2020
Clement ND Afzal I Demetriou C Deehan DJ Field RE Kader DF

Aims

The primary aim of this study was to assess whether the postoperative Oxford Knee Score (OKS) demonstrated a ceiling effect at one and/or two years after total knee arthroplasty (TKA). The secondary aim was to identify preoperative independent predictors for patients that achieved a ceiling score after TKA.

Methods

A retrospective cohort of 5,857 patients undergoing a primary TKA were identified from an established arthroplasty database. Patient demographics, body mass index (BMI), OKS, and EuroQoL five-dimension (EQ-5D) general health scores were collected preoperatively and at one and two years postoperatively. Logistic regression analysis was used to identify independent preoperative predictors of patients achieving postoperative ceiling scores. Receiver operating characteristic curve was used to identify a preoperative OKS that predicted a postoperative ceiling score.


Bone & Joint Research
Vol. 8, Issue 5 | Pages 207 - 215
1 May 2019
Key S Scott G Stammers JG Freeman MAR Pinskerova V Field RE Skinner J Banks SA

Objectives

The medially spherical GMK Sphere (Medacta International AG, Castel San Pietro, Switzerland) total knee arthroplasty (TKA) was previously shown to accommodate lateral rollback while pivoting around a stable medial compartment, aiming to replicate native knee kinematics in which some coronal laxity, especially laterally, is also present. We assess coronal plane kinematics of the GMK Sphere and explore the occurrence and pattern of articular separation during static and dynamic activities.

Methods

Using pulsed fluoroscopy and image matching, the coronal kinematics and articular surface separation of 16 well-functioning TKAs were studied during weight-bearing and non-weight-bearing, static, and dynamic activities. The closest distances between the modelled articular surfaces were examined with respect to knee position, and proportions of joint poses exhibiting separation were computed.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 86 - 86
1 Apr 2019
Al-Zibari M Everett SJ Afzal I Overschelde PV Skinner J Scott G Kader DF Field RE
Full Access

Background

In the late 1980's Michael Freeman conceived the idea that knee replacement would most closely replicate the natural knee joint, if the medial Tibio-Femoral articulation was configured as a “ball-in-socket”. Over the last three decades, medial rotation and medial pivot designs have proved successful in clinical use. Freeman's final iteration of the medial ball-in-socket concept was the Medial Sphere knee. We report the three-year survivorship, clinical outcomes, patient reported outcome measures (PROMs) and radiographic analysis of this implant in a multi-centre, multi-surgeon, prospective observational study.

Methods

Patients awaiting total knee replacement were recruited by four centres. They had no medical contraindication to surgery, were able to provide informed consent and were available for follow-up. Primary outcome was implant survival at six months, one, two, three and five years. Secondary outcomes were patient reported outcome measures: Oxford Knee Score (OKS), Euroqol (EQ-5D), International Knee Society Score (IKSS), IKSS Functional score and Health State score, complications and radiographic outcomes. Radiographic analysis was undertaken using the TraumaCad software and data analysis was undertaken using SPSS.


Bone & Joint Research
Vol. 5, Issue 3 | Pages 80 - 86
1 Mar 2016
Scott G Imam MA Eifert A Freeman MAR Pinskerova V Field RE Skinner J Banks SA

Objectives

Throughout the 20th Century, it has been postulated that the knee moves on the basis of a four-bar link mechanism composed of the cruciate ligaments, the femur and the tibia. As a consequence, the femur has been thought to roll back with flexion, and total knee arthroplasty (TKA) prostheses have been designed on this basis. Recent work, however, has proposed that at a position of between 0° and 120° the medial femoral condyle does not move anteroposteriorly whereas the lateral femoral condyle tends, but is not obliged, to roll back – a combination of movements which equates to tibial internal/ femoral external rotation with flexion. The aim of this paper was to assess if the articular geometry of the GMK Sphere TKA could recreate the natural knee movements in situ/in vivo.

Methods

The pattern of knee movement was studied in 15 patients (six male: nine female; one male with bilateral TKAs) with 16 GMK Sphere implants, at a mean age of 66 years (53 to 76) with a mean BMI of 30 kg/m2 (20 to 35). The motions of all 16 knees were observed using pulsed fluoroscopy during a number of weight-bearing and non-weight-bearing static and dynamic activities.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 35 - 35
1 Jan 2016
Banks S Imam M Eifert A Field RE
Full Access

Introduction

Total knee arthroplasty (TKA) designs evolve as evidence accumulates on natural and prosthetic knee function. TKA designs based upon a medially conforming tibiofemoral articulation seek to reproduce essential aspects of normal knee stability and have enjoyed good clinical success and high patient satisfaction for over two decades. Fluoroscopic kinematic studies on several medially conforming knee designs show extremely stable knee function, but very small ranges of tibial axial rotation compared to healthy knees. The GMK Sphere TKA is a recent evolution in medially-conforming TKA designs that adopts a sagittally unconstrained lateral tibiofemoral articulation to allow more natural tibial rotation. This study was conducted to quantify motions in knees with this prosthesis to address two questions:

Does the medially conforming GMK Sphere design provide an AP-stable articulation that provides for tibiofemoral translations that are comparable to, but not larger than, translations measured in natural knees?

Does the medially conforming GMK Sphere design provide sufficient rotatory laxity to allow tibiofemoral rotations comparable to, but not larger than, rotations measured in natural knees?

Materials and Methods

Fifteen patients (9 females), mean age 65 years and mean BMI of 30 ±3, consented to participate. Sixteen knees received the GMK Sphere TKA. Mean Oxford Knee Score (OKS) improved significantly from 19±7 to 40±3 six months post surgery (P< 0.0001). On the day of the study, the mean OKS, Knee Society Score, EQ5D and Heath status scores were 40, 87, 0.83 and 85 respectively. Mean ROM from active maximum extension till maximum supine flexion was 108°±8°.

Motions in 16 knees were observed using pulsed-fluoroscopy during a range of activities. Subjects were observed in maximum flexion kneeling and lunging positions, and in stepping up/down on a 22cm step. Model-image registration methods were used to quantify three-dimensional knee motions from digitized fluoroscopic images.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 458 - 458
1 Dec 2013
Noble P Dwyer M Jones H Field RE McCarthy JC
Full Access

Objectives:

Experimental disruption of the labrum has been shown to compromise its sealing function and alter cartilage lubrication. However, it is not known whether pathological changes to the labrum secondary to femoro-acetabular impingement (FAI) have a similar impact on labral function. This study was performed to determine the effect of natural labral damage secondary to abnormal femoral morphology on the labral seal.

Methods:

Ten intact hip specimens were obtained from male donors (47.8 ± 1.5 yrs) for use in this study. CT reconstructions demonstrated that 6 specimens were of normal morphology, while 4 displayed morphology typical of cam-FAI. Specimens were dissected free of the overlying soft tissue, leaving the capsule and labrum intact. Each specimen was potted and placed in a loading apparatus (0.5 BW). Pressures developed within the central and peripheral compartments were monitored with miniature pressure transducers. The sealing capacity of the labrum was measured by introducing fluid into the central compartment at a constant rate until transport was detected from the central to the peripheral compartment. These measurements were performed in 10 functional positions simulating sequential stages of gait, stooping, and pivoting. During testing, the 3D motion of the femoral head in the acetabulum was measured with motion analysis combined with computer visualization. Peak pressures were compared between specimens with and without labral damage for each of the three activities (p < 0.05).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 139 - 139
1 Dec 2013
Noble P Dwyer M Jones H Field RE McCarthy JC
Full Access

Introduction:

The sealing function of the acetabular labrum is central to the stability of the hip and the health of the joint. Disruption of the labrum has been shown to reduce intra-articular pressure and increase the rate of cartilage consolidation during static loading. Functional activities require movement of the hip through wide ranges of joint motion which disrupt joint congruency, and thus may alter the seal. This study was performed to test the hypothesis that the sealing function of the labrum varies with the position of the hip during functional activities.

Methods:

Six fresh cadaveric hip joint specimens were obtained from donors of average age 45.5 ± 16.1 years (range 25–63 years). Each specimen was dissected free of soft tissue, leaving the capsule and labrum intact, potted in mounting fixtures, and placed in a loading apparatus. Catheters were inserted into the central and peripheral compartments of each hip to allow infusion of fluid and monitoring of compartment pressures via miniature transducers (OMEGA Engineering, Inc). After application of a joint load of 0.50 BW, fluid was introduced into the central compartment at a constant rate until transport was indicated by a rise in pressure within the peripheral compartment. These measurements were performed with each hip placed in 10 functional positions ranging from −5 to 105 degrees of flexion, −5 to 13 degrees of abduction, and −25 to 35 degrees of external rotation simulating the sequential stages of gait, stooping, and pivoting. Motion analysis was performed via reflective marker arrays attached to the femur and pelvis to allow computer visualization of the position of the pelvis and femur using CT reconstructions. In each hip position, we measured the peak pressure (kPA) developed within the central compartment prior to fluid transfer to the peripheral compartment.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 45 - 51
1 Jan 2013
Williams DP Blakey CM Hadfield SG Murray DW Price AJ Field RE

The Oxford knee score (OKS) is a validated and widely accepted disease-specific patient-reported outcome measure, but there is limited evidence regarding any long-term trends in the score. We reviewed 5600 individual OKS questionnaires (1547 patients) from a prospectively-collected knee replacement database, to determine the trends in OKS over a ten-year period following total knee replacement. The mean OKS pre-operatively was 19.5 (95% confidence interval (CI) 18.8 to 20.2). The maximum post-operative OKS was observed at two years (mean score 34.4 (95% CI 33.7 to 35.2)), following which a gradual but significant decline was observed through to the ten-year assessment (mean score 30.1 (95% CI 29.1 to 31.1)) (p < 0.001). A similar trend was observed for most of the individual OKS components (p < 0.001). Kneeling ability initially improved in the first year but was then followed by rapid deterioration (p < 0.001). Pain severity exhibited the greatest improvement, although residual pain was reported in over two-thirds of patients post-operatively, and peak improvement in the night pain component did not occur until year four. Post-operative OKS was lower for women (p < 0.001), those aged < 60 years (p < 0.003) and those with a body mass index > 35 kg/m2 (p < 0.014), although similar changes in scores were observed. This information may assist surgeons in advising patients of their expected outcomes, as well as providing a comparative benchmark for evaluating longer-term outcomes following knee replacement.

Cite this article: Bone Joint J 2013;95-B:45–51.


The Bone & Joint Journal
Vol. 95-B, Issue 1 | Pages 38 - 44
1 Jan 2013
Williams DP Price AJ Beard DJ Hadfield SG Arden NK Murray DW Field RE

We present a comparison of patient-reported outcomes (PROMs) in relation to patient age, in patients who had received a total (TKR) or unicompartmental knee replacement (UKR). The outcome was evaluated using the Oxford knee score (OKS), EuroQol (EQ-5D) and satisfaction scores. Patients aged 65 to 84 years demonstrated better pre-operative function scores than those aged < 65 years (OKS, p = 0.03; EQ-5D, p = 0.048) and those aged ≥ 85 years (OKS, p = 0.03). Post-operative scores were comparable across age groups, but a linear trend for greater post-operative improvement in OKS and EQ-5D was seen with decreasing age (p < 0.033). The overall mean satisfaction score at six months was 84.9, but those aged <  55 years exhibited a lower mean level of satisfaction (78.3) compared with all other age groups (all p < 0.031). The cumulative overall two-year revision rate was 1.3%. This study demonstrates that good early outcomes, as measured by the OKS and EQ-5D, can be anticipated following knee replacement regardless of the patient’s age, although younger patients gain greater improvement. However, the lower satisfaction in those aged < 55 years is a concern, and suggests that outcome is not fully encapsulated by the OKS and EQ-5D evaluation, and raises the question whether the OKS alone is an appropriate measure of pain and function in younger, more active individuals.

Cite this article: Bone Joint J 2013;95-B:38–44.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 8 | Pages 1120 - 1125
1 Aug 2012
Alazzawi S Bardakos NV Hadfield SG Butt U Beer ZH Field RE

Using general practitioner records and hospital notes and through direct telephone conversation with patients, we investigated the accuracy of nine patient-reported complications gathered from a self-completed questionnaire after elective joint replacement surgery of the hip and knee. A total of 402 post-discharge complications were reported after 8546 elective operations that were undertaken within a three-year period. These were reported by 136 men and 240 women with a mean age of 71.8 years (34 to 93). A total of 319 reported complications (79.4%; 95% confidence interval 75.4 to 83.3) were confirmed to be correct. High rates of correct reporting were demonstrated for infection (94.5%) and the need for further surgery (100%), whereas the rates of reporting deep-vein thrombosis (DVT), pulmonary embolism, myocardial infarction and stroke were lower (75% to 84.2%). Dislocation, peri-prosthetic fractures and nerve palsy had modest rates of correct reporting (36% to 57.1%). More patients who had knee surgery delivered incorrect reports of dislocation (p = 0.001) and DVT (p = 0.013).

Despite these variations, it appears that post-operative complications may form part of a larger patient-reported outcome programme after elective joint replacement surgery.


Bone & Joint 360
Vol. 1, Issue 2 | Pages 7 - 10
1 Apr 2012
Field RE Shimmin A Cattani L

The need to demonstrate probity and fair market competition has increased scrutiny of the relationships between orthopaedic surgeons and the industry that supplies them with their tools and devices. Investigations and judgements from the US Department of Justice and the introduction of the AdvaMed and Eucomed codes have defined new boundaries for interactions between these groups. This article summarises the current interplay between orthopaedic surgeons and industry, and provides recommendations for the future.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 412 - 418
1 Mar 2012
Judge A Arden NK Kiran A Price A Javaid MK Beard D Murray D Field RE

We obtained information from the Elective Orthopaedic Centre on 1523 patients with baseline and six-month Oxford hip scores (OHS) after undergoing primary hip replacement (THR) and 1784 patients with Oxford knee scores (OKS) for primary knee replacement (TKR) who completed a six-month satisfaction questionnaire.

Receiver operating characteristic curves identified an absolute change in OHS of 14 points or more as the point that discriminates best between patients’ satisfaction levels and an 11-point change for the OKS. Satisfaction is highest (97.6%) in patients with an absolute change in OHS of 14 points or more, compared with lower levels of satisfaction (81.8%) below this threshold. Similarly, an 11-point absolute change in OKS was associated with 95.4% satisfaction compared with 76.5% below this threshold. For the six-month OHS a score of 35 points or more distinguished patients with the highest satisfaction level, and for the six-month OKS 30 points or more identified the highest level of satisfaction. The thresholds varied according to patients’ pre-operative score, where those with severe pre-operative pain/function required a lower six-month score to achieve the highest levels of satisfaction.

Our data suggest that the choice of a six-month follow-up to assess patient-reported outcomes of THR/TKR is acceptable. The thresholds help to differentiate between patients with different levels of satisfaction, but external validation will be required prior to general implementation in clinical practice.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 12 | Pages 1660 - 1664
1 Dec 2011
Judge A Arden NK Price A Glyn-Jones S Beard D Carr AJ Dawson J Fitzpatrick R Field RE

We obtained pre-operative and six-month post-operative Oxford hip (OHS) and knee scores (OKS) for 1523 patients who underwent total hip replacement and 1784 patients who underwent total knee replacement. They all also completed a six-month satisfaction question.

Scatter plots showed no relationship between pre-operative Oxford scores and six-month satisfaction scores. Spearman’s rank correlation coefficients were -0.04 (95% confidence interval (CI) -0.09 to 0.01) between OHS and satisfaction and 0.04 (95% CI -0.01 to 0.08) between OKS and satisfaction. A receiver operating characteristic (ROC) curve analysis was used to identify a cut-off point for the pre-operative OHS/OKS that identifies whether or not a patient is satisfied with surgery. We obtained an area under the ROC curve of 0.51 (95% CI 0.45 to 0.56) for hip replacement and 0.56 (95% CI 0.51 to 0.60) for knee replacement, indicating that pre-operative Oxford scores have no predictive accuracy in distinguishing satisfied from dissatisfied patients.

In the NHS widespread attempts are being made to use patient-reported outcome measures (PROMs) data for the purpose of prioritising patients for surgery. Oxford hip and knee scores have no predictive accuracy in relation to post-operative patient satisfaction. This evidence does not support their current use in prioritising access to care.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 1 | Pages 108 - 110
1 Jan 2011
Rajakulendran K Strambi F Buly J Field RE

Developmental dysplasia of the hip predisposes to premature degenerative hip disease. A number of operations have been described to improve acetabular cover and have achieved varying degrees of success. We present the case of an 84-year-old woman, who underwent a shelf procedure to reconstruct a dysplastic hip 75 years ago. To date, the shelf remains intact and the hip is asymptomatic. We believe this represents the longest documented outcome of any procedure to stabilise the hip.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 12 | Pages 1561 - 1565
1 Dec 2009
Blakey CM Eswaramoorthy VK Hamilton LC Biant LC Field RE

We report the minimum five-year follow-up of 352 primary total hip replacements using the uncemented hydroxyapatite-coated ANCA-Fit femoral component with a modular neck and head. The series comprised 319 patients (212 men, 107 women) with a mean age at operation of 64.4 years (28 to 97). The principal diagnosis was osteoarthritis. A total of 18 patients (21 hips) died before their follow-up at five years, nine patients (11 hips) were lost to follow-up, and four (four hips) declined further follow-up. Patient-reported outcomes have been recorded for 288 patients (316 hips).

Their mean Oxford Hip Score improved significantly from 41 points (16 to 57) pre-operatively to 20 points (12 to 44) at five-year follow-up. Radiological assessment showed good bony stability in 98% of implants. There were two cases of aseptic loosening of the femoral component. There were no clinical or radiological complications related to modularity. In our series we did not see the high rate of intra-operative fracture previously reported for this implant.

This medium-term follow-up study demonstrates that the clinical outcome of the ANCA-Fit femoral component is, to date, comparable with that of other metaphyseal loading femoral components.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 11 | Pages 1454 - 1458
1 Nov 2009
Eswaramoorthy VK Biant LC Field RE

We report the outcome of total hip replacement in 29 failed metal-on-metal resurfacing hip replacements in which the primary surgery was performed between August 1995 and February 2005. The mean length of follow-up was five years (1.7 to 11.7). Of the 29 hip resurfacings, 19 acetabular components and all the femoral components were revised (28 uncemented stems and one cemented stem). There were no deaths and none of the patients was lost to follow-up. None of the hips underwent any further revision. The results of the revision resurfacing group were compared with those of a control group of age-matched patients. In the latter group there were 236 primary total hip replacements and 523 resurfacings performed during the same period by the same surgeons.

The outcome of the revision resurfacing group was comparable with that of the stemmed primary hip replacement group but was less good than that of the primary hip resurfacing group. Long-term follow-up is advocated to monitor the outcome of these cases.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 6 | Pages 776 - 783
1 Jun 2009
Rajesparan K Biant LC Ahmad M Field RE

Tranexamic acid is a fibrinolytic inhibitor which reduces blood loss in total knee replacement. We examined the effect on blood loss of a standardised intravenous bolus dose of 1 g of tranexamic acid, given at the induction of anaesthesia in patients undergoing total hip replacement and tested the potential prothrombotic effect by undertaking routine venography. In all, 36 patients received 1 g of tranexamic acid, and 37 no tranexamic acid. Blood loss was measured directly per-operatively and indirectly post-operatively.

Tranexamic acid reduced the early post-operative blood loss and total blood loss (p = 0.03 and p = 0.008, respectively) but not the intraoperative blood loss. The tranexamic acid group required fewer transfusions (p = 0.03) and had no increased incidence of deep-vein thrombosis. The reduction in early post-operative blood loss was more marked in women (p = 0.05), in whom this effect was dose-related (r = −0.793).

Our study showed that the administration of a standardised pre-operative bolus of 1 g of tranexamic acid was cost-effective in reducing the blood loss and transfusion requirements after total hip replacement, especially in women.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 4 | Pages 533 - 535
1 Apr 2009
Hamilton LC Biant LC Temple LN Field RE

Idiopathic calcium pyrophosphate deposition disease (pseudogout) has a variable presentation. Many joints are usually affected; single joint disease is uncommon. We present a case report of primary monoarticular pseudogout affecting the hip. The diagnosis was made on the appearance and analysis of specimens obtained at arthroscopy. Monoarticular pseudogout is rare, but should be considered in the differential diagnosis of any presentation of joint pain.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 10 | Pages 1278 - 1283
1 Oct 2008
Eswaramoorthy V Moonot P Kalairajah Y Biant LC Field RE

We report the clinical and radiological outcome at ten years of 104 primary total hip replacements (100 patients) using the Metasul metal-on-metal bearing. Of these, 52 had a cemented Stuehmer-Weber polyethylene acetabular component with a Metasul bearing and 52 had an uncemented Allofit acetabular component with a Metasul liner. A total of 15 patients (16 hips) died before their follow-up at ten years and three were lost to follow-up. The study group therefore comprised 82 patients (85 hips).

The mean Oxford score at ten years was 20.7 (12 to 42). Six of 85 hips required revision surgery. One was performed because of infection, one for aseptic loosening of the acetabular component and four because of unexplained pain. Histological examination showed an aseptic lymphocytic vasculitis associated lesion-type tissue response in two of these. Continued follow-up is advocated in order to monitor the long-term performance of the Metasul bearing and tissue responses to metal debris.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 531 - 531
1 Aug 2008
Monoot P Eswaramoorthy V Kalairajah YE Field RE
Full Access

Introduction: Total hip replacements (THR) with the first generation metal-on-metal articulation were abandoned in 1970s in favour of metal-on-polyethylene articulation. Osteolysis due to polyethylene wear particles renewed the interest in metal-on-metal articulations. The second generation had improved clearance, metal hardness and reproducible surfaces. We describe the 10-year outcome of 63 THR with Metasul metal-on-metal articulation.

Methods: From 1995 to 1996, 86 patients (90 hips) underwent THR with Metasul articulation and cemented CF-30 femoral stem. Of these, 55 hips had a cemented Stuhmer-Weber-Allopro cup and 35 hips had an uncemented Allofit cup. Eleven patients (12 hips) died and five patients (6 hips) were not available for clinical evaluation. However all had been contacted and it was known that the hip was not painful and had not been revised. Nine patients were lost to follow up. Thirty nine hips in cemented group and 24 hips in uncemented group had clinical, radiological and Oxford hip score (OHS) at minimum of 10-years follow-up after the operation.

Results: The minimum length of follow up was 10-years with an average of 10.8 years. The average OHS at 10 years for the cemented group was 23 (range 12 – 42) and for the hybrid group was 20.3 (range 12 – 37). Five out of 63 (8%) hips had revision surgery. Two revisions (3%) were performed because of infection, 1 was revised (1.5%) because of unexplained pain and suspected metallosis and 2 were revised (3%) for suspected aseptic acetabular cup loosening.

Conclusion: In comparison with the outcome of first generation metal-on-metal bearing, the hips in our study had lower rate of revision due to acetabular wear and loosening. This is the first study to show that the Metasul articulation has good outcome over a 10-year period. The survivorship is 97% with aseptic loosening as the endpoint for revision surgery.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 560 - 560
1 Aug 2008
Kamat YD Aurakzai K Kalairajah Y Riordan J Field RE Adhikari AR
Full Access

Obesity [Body Mass Index (BMI) > 30kg/m2] is seen in a growing percentage of patients seeking joint replacement surgery. Operations in obese patients take longer and present certain technical difficulties. Computer navigation improves consistency of prosthetic component alignment but increases operation time.

Our aims were

to compare tourniquet times of non-obese with obese patients having knee replacement using standard instruments or computer navigation and

to evaluate the change in tourniquet time as the surgeon gained experience over a three year period.

A retrospective analysis of 232 total knee replacement (TKR) operations performed by a single knee surgeon over a three year period was carried out. Similar knee prostheses (Plus Orthopedics, UK) were used in all cases. Variables to be assessed were the operative technique (computer navigation assisted or standard instruments) and BMI of patients.

Of the 232 knees, 117 were performed using computer navigation and 115 with standard instruments. Each of the groups was subdivided as per BMI to differentiate obese patients (BMI > 30) from the non-obese. Tourniquet times of surgery were used for comparison amongst the subgroups.

There were 56 and 59 patients in the non-obese and obese subgroups respectively within the standard TKR group. The average tourniquet times for these were 79.3 and 86.3 minutes respectively. This was a significant difference (p=0.037). Correspondingly in the computer navigated group, there were 60 non-obese and 57 obese patients. Their tourniquet times were 105.4 and 100.5 minutes respectively. This difference was not significant (p=0.15)

The obese patients in each group were then studied separately and divided into three equally sized subgroups in chronological order. Each sub-group comprised 19 standard TKRs and 19 computer navigated TKRs. Tourniquet times of operations were compared within each sub-group. P values within the first subgroup showed a significant difference. There was no significant difference within the second and third subgroups.

We concluded that obesity significantly increased the operative time in the standard TKR group. However in computer navigated TKR there was no significant difference in operative time between non-obese and obese patients. As the surgeon acquired experience of computer navigation there was no difference in time taken for conventional and computer navigated TKR in obese patients. We hypothesize that in obese patients, computer assisted navigation helps the surgeon to overcome jig alignment uncertainty without any time penalty.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 319 - 323
1 Mar 2008
Moonot P Singh PJ Cronin MD Kalairajah YE Kavanagh TG Field RE

Hip resurfacing is a bone-conserving procedure with respect to proximal femoral resection, but there is debate in the literature as to whether the same holds true for the acetabulum. We have investigated whether the Birmingham hip resurfacing conserves acetabular bone.

Between 1998 and 2005, 500 Birmingham hip resurfacings were performed by two surgeons. Between 1996 and 2005 they undertook 700 primary hip replacements, with an uncemented acetabular component. These patients formed the clinical material to compare acetabular component sizing. The Birmingham hip resurfacing group comprised 350 hips in men and 150 hips in women. The uncemented total hip replacement group comprised 236 hips in men and 464 hips in women. Age- and gender-matched analysis of a cohort of patients for the sizes of the acetabular components required for the two types of replacement was also undertaken. Additionally, an analysis of the sizes of the components used by each surgeon was performed.

For age-matched women, the mean outside diameter of the Birmingham hip resurfacing acetabular components was 2.03 mm less than that of the acetabular components in the uncemented total hip replacements (p < 0.0001). In similarly matched men there was no significant difference (p = 0.77). A significant difference was also found between the size of acetabular components used by the two surgeons for Birmingham hip resurfacing for both men (p = 0.0015) and women (p = 0.001). In contrast, no significant difference was found between the size of acetabular components used by the two surgeons for uncemented total hip replacement in either men or women (p = 0.06 and p = 0.14, respectively). This suggests that variations in acetabular preparation also influence acetabular component size in hip resurfacing.


The Journal of Bone & Joint Surgery British Volume
Vol. 90-B, Issue 3 | Pages 360 - 363
1 Mar 2008
Changulani M Kalairajah Y Peel T Field RE

We audited the relationship between obesity and the age at which hip and knee replacement was undertaken at our centre. The database was analysed for age, the Oxford hip or knee score and the body mass index (BMI) at the time of surgery. In total, 1369 patients were studied, 1025 treated by hip replacement and 344 by knee replacement. The patients were divided into five groups based on their BMI (normal, overweight, moderately obese, severely obese and morbidly obese).

The difference in the mean Oxford score at surgery was not statistically significant between the groups (p > 0.05). For those undergoing hip replacement, the mean age of the morbidly obese patients was ten years less than that of those with a normal BMI. For those treated by knee replacement, the difference was 13 years. The age at surgery fell significantly for those with a BMI > 35 kg/m2 for both hip and knee replacement (p > 0.05). This association was stronger for patients treated by knee than by hip replacement.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 8 | Pages 1110 - 1115
1 Aug 2006
Ong KL Kurtz SM Manley MT Rushton N Mohammed NA Field RE

The effects of the method of fixation and interface conditions on the biomechanics of the femoral component of the Birmingham hip resurfacing arthroplasty were examined using a highly detailed three-dimensional computer model of the hip. Stresses and strains in the proximal femur were compared for the natural femur and for the femur resurfaced with the Birmingham hip resurfacing. A comparison of cemented versus uncemented fixation showed no advantage of either with regard to bone loading. When the Birmingham hip resurfacing femoral component was fixed to bone, proximal femoral stresses and strains were non-physiological. Bone resorption was predicted in the inferomedial and superolateral bone within the Birmingham hip resurfacing shell. Resorption was limited to the superolateral region when the stem was not fixed. The increased bone strain observed adjacent to the distal stem should stimulate an increase in bone density at that location. The remodelling of bone seen during revision of failed Birmingham hip resurfacing implants appears to be consistent with the predictions of our finite element analysis.


The Journal of Bone & Joint Surgery British Volume
Vol. 88-B, Issue 3 | Pages 315 - 320
1 Mar 2006
Field RE Singh PJ Latif AMH Cronin MD Matthews DJ

We describe the results at five years of a prospective study of a new tri-tapered polished, cannulated, cemented femoral stem implanted in 51 patients (54 hips) with osteoarthritis. The mean age and body mass index of the patients was 74 years and 27.9, respectively. Using the anterolateral approach, half of the stems were implanted by a consultant orthopaedic surgeon and half by six different registrars. There were three withdrawals from the study because of psychiatric illness, a deep infection and a recurrent dislocation. Five deaths occurred prior to five-year follow-up and one patient withdrew from clinical review.

In the remaining 51 hips the mean pre-operative Oxford hip score was 47 points which decreased to 19 points at five years (45 hips). Of the stems 49 (98%) were implanted within 1° of neutral in the femoral canal. The mean migration of the stem at five years was 1.9 mm and the survivorship for aseptic loosening was 100%. There was no significant difference in outcome between the consultant and registrar groups. At five years, the results were comparable with those of other polished, tapered, cemented stems. Long-term surveillance continues.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 10 | Pages 1344 - 1351
1 Oct 2005
Field RE Rushton N

The Cambridge Cup has been designed to replace the horseshoe-shaped articular cartilage of the acetabulum and the underlying subchondral bone. It is intended to provide physiological loading with minimal resection of healthy bone.

The cup has been used in 50 women with displaced, subcapital fractures of the neck of the femur. In 24 cases, the cup was coated with hydroxyapatite. In 26, the coating was removed before implantation in order to simulate the effect of long-term resorption.

The mean Barthel index and the Charnley-modified Merle d’Aubigné scores recovered to their levels before fracture. We reviewed 30 women at two years, 21 were asymptomatic and nine reported minimal pain. The mean scores deteriorated slightly after five years reflecting the comorbidity of advancing age. Patients with the hydroxyapatite-coated components remained asymptomatic, with no wear or loosening. The uncoated components migrated after four years and three required revision. This trial shows good early results using a novel, hydroxyapatite-coated, physiological acetabular component.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 5 | Pages 618 - 622
1 May 2005
Field RE Cronin MD Singh PJ

We have used the Oxford hip score to monitor the progress of 1908 primary and 279 revision hip replacements undertaken since the start of 1995. Our review programme began in early 1999 and has generated 3900 assessments.

The mean pre-operative scores for primary and revision cases were 40.95 and 40.11, respectively. The mean annual score for primary replacement at between 12 and 84 months ranged between 20.60 and 22.57. A comparison of cross-sectional and longitudinal data showed no significant differences. All post-operative reviews showed a significant improvement (p ≤ 0.0001). The 50- to 60-year-old group scored significantly better than the patients over 80 years of age up to 48 months (p < 0.01). A subgroup of 826 National Health Service (NHS) and 397 private patients, treated by the senior author (2292 Oxford assessments), had a higher (i.e. worse) mean pre-operative score for the NHS patients (p ≤ 0.001). The private patients scored better than the NHS group up to 84 months (p < 0.05). Patients treated by a surgeon performing more than 100 replacements each year had a significantly better outcome up to five years than those operated on by surgeons performing fewer than 20 replacements each year. The age of the patients at the time of operation, and their pre-operative level of disability, have both been identified as affecting the long-term outcome. Awareness of the influence of these factors should assist surgeons to provide balanced advice.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 261 - 261
1 Mar 2004
Field RE Singh PJ
Full Access

Aim: Analyse the outcome of primary and revision total hip replacement using the Oxford hip score. To determine any variation in outcome when analysing for age of patient. In addition, to compare the outcome in the National Health Service compared to the Private hospital. Method: We have used the Oxford Hip score to monitor the progress of 1441 primary and 173 revision hip replacements (THR) undertaken since the start of 1995 whose hips have been replaced, at St Helier Hospital, Carshalton and St Anthony’s Hospital, Cheam, over the last seven years. Our review programme was started in early 1999 and has generated 2286 Oxford assessments.). A subgroup of 634 National Health Service (NHS) and 322 private patients (PP), treated by the senior author, has provided 1277 Oxford assessments. Results: Mean preoperative scores were 39.06 and 39.48 for primary and revision THR respectively. The mean annual scores, for primary THR, from 12 to 84 months declined to 21 points at 1 year, 21 at 2 years, 21 at 3 years, 20 at 4 years, 22 at 6 years and 21 at 7 years. Conclusion: All postoperative reviews show a significant improvement (p ≤0.0001). The 50–60 year old group scored significantly better than the over 80 year patients up to 48 months, (p< 0.01) The mean preoperative score for the NHS patients was significantly higher than the PPs (p< 0.001). The PPs scored significantly better than the NHS group up to 36 months (p< 0.01).


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 76 - 76
1 Jan 2004
Singh PJ Marsh AJ Kerry SM Field RE
Full Access

Aim: To develop an accurate and reproducible validated digital technique for the two-dimensional measurement of longitudinal femoral stem migration on AP radiographs.

Method: Eight patients who underwent total hip replacement, under the care of the senior author, were randomly selected. In each case, three radio-opaque marker beads had been implanted into the greater trochanteric region at surgery. Using a standardised x-ray protocol, three consecutive AP standing hip x-rays were taken of each patient on the same day. The plain radiographs were digitised, and the vertical bead to stem tip distance measured by two orthopaedic trainees using Scion Image ‘freeware’ software package and standard computer equipment. Every patient had three different measurements on each of their three consecutive x-rays. The vertical bead to stem tip distance was averaged over the three beads.

Results: Statistical analysis was performed and the repeatability coefficient between x-rays was 0.61 (confidence interval 0.46 to 0.78). The limits of agreement for inter observer error for average bead to stem distance were −0.15 to 0.39.

Conclusion: Our results demonstrate the efficacy of our system for analysis of femoral stem migration in everyday clinical practice. This technique does require implantation of marker beads and a standardised protocol for patient positioning for radiographs.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 76 - 76
1 Jan 2004
Field RE Kavanagh TG Singh PJ
Full Access

Aim: Hip resurfacing is a bone conserving procedure with respect to proximal femoral resection. For previous generations of conservative hip replacement, preservation of the natural femoral head diameter necessitated additional sacrifice of acetabular bone in order to accommodate a sufficiently thick polyethylene acetabular component. We have investigated whether the BHR offers a bone conserving procedure with respect to the acetabular bone stock.

Method: We reviewed 284 Birmingham resurfacing hip replacements (BHR), and 479, primary hip replacements, in which an uncemented acetabular component (THUA) was used. The BHR and THUA group had mean age at surgery of 55 and 65 years respectively. In 32 BHR’s and 21 THUA, pre-operative templating measurements were available for subsequent comparison with size of component implanted.

Results: Comparison of component sizes, for both implant types, confirmed bi-modal distribution according to patient gender. BHR cups, implanted by the first author, in females, were significantly smaller than those implanted, by the same author, in THUA,(p< 0.0001). Pre-operative templating overestimated component size for all groups but the difference was only significant in male BHR cases;(p=0.03). BHR cups implanted by the first author were significantly smaller than the second author, for both male (p= 0.0001) and female patients;(p< 0.001).

Conclusion: In females, BHR is bone a conserving procedure for femoral and acetabular components. In males, the procedure is not bone sacrificing when compared to THUA. Pre-operative templating can overestimate size of acetabular component that will be used for men. A significant difference was found between size of acetabular components used by two surgeons for BHR.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 76 - 77
1 Jan 2004
Singh PJ Field RE Burtenshaw C Jaffer O
Full Access

Introduction: The acetabular cup comprises a 3mm thick bearing surface of UHMPE, a 1.5mm backing of 30% carbon fibre reinforced polybutyleneterephthalate (CFRPBT). Young’s modulus, of CFRPBT layer is similar to natural subchondral bony plate. The cup deforms, when loaded, with the surrounding acetabular bone so that micro-motion at the bone-prosthesis interface is reduced. We measured BMD in the periacetabulum

Method: BMD was analysed for 2 years (n=11 females) with Mean Barthel Index at 2 years 19. Regions of interest were defined according to De-Lee and Charnley (ROI I-III) for the acetabulum. BMD during follow-up was compared with immediate post-operative values. Mean precision error (CV%) was 1.8±0.87%.

Results: By 2 years the mean BMD in HA cup was 0.73gms/cm2 representing a decrease of 7% and 0.78gms/cm2, which representing a 4% decrease with the non-HA cup. With the HA cup at 2 years we measured an increase in ROI I of 3% and a reduction in ROI II and III of 3% and 20% respectively. With the non-HA cup at 2 years we measured an increase in ROI II of 7% and a reduction in ROI I and III of 3% and 16%. There was a significant difference (p< 0.05) in the BMD changes measured in non-weight bearing zone III and one of the weight bearing zones (zone II).

Conclusion: Changes in BMD measured reflect a pattern of maximally reduced stress in zone III followed by zone II and least in the load bearing axis of the acetabulum zone I.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 77 - 77
1 Jan 2004
Singh PJ Field RE
Full Access

Aim: A prospective study was undertaken to define the pattern of bone remodelling using DXA following implantation of our polished, tri-tapered, collarless, cannulated cemented femoral component.

Method: Our stem was implanted in 20 primary THRs. Our subjects comprised 7 male and 13 female patients. At the time of surgery the mean age was 73 (range 65 to 131). The mean weight at surgery was 75.4kg (range 47kg to 131.8kg) with a mean BMI of 28(range 22 to 40). All patients had a pre operative diagnosis of osteoarthritis. All the hips were implanted via the anterolateral approach. Pre-operative and sequential post-operative DXA evaluations were undertaken at 3 weeks, 6 and 12 months.

Results: The mean precision error was 0.78%(range 0.8–3.4% depending on region of interest). Statistical analysis revealed a significant increase in BMD measured in zones 1,2,4,5,6 (p< 0.05). In zones 3 and 7, the increase in BMD was not significant (p> 0.05). The real percentage increase in BMD at 12 months was 43% in zone 1, 20% in zone 2, 8% in zone 3, 31% in zone 4, 12% in zone 5, 24% in zone 6 and 7% in zone 7.

Conclusion: Peri-prosthetic bone remodelling has been observed within one year following total hip replacement (THR), which has been demonstrated by an increase in BMD in all zones. The implantation of our tri-tapered cannulated cemented femoral component, thus provides favourable proximal femoral loading at 12 months. Additional studies will determine whether stabilization of this bone turnover continues in the long term.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 77 - 77
1 Jan 2004
Field RE Singh PJ
Full Access

Aim: Analyse the outcome of primary and revision total hip replacement using the Oxford hip score. To determine any variation in outcome when analysing for age of patient. In addition, to compare the outcome in the National Health Service compared to the Private hospital.

Method: We have used the Oxford Hip score to monitor the progress of 1441 primary and 173 revision hip replacements (THR) undertaken since the start of 1995 whose hips have been replaced, at St Helier Hospital, Carshalton and St Anthony’s Hospital, Cheam, over the last seven years. Our review programme was started in early 1999 and has generated 2286 Oxford assessments. ). A subgroup of 634 National Health Service (NHS) and 322 private patients (PP), treated by the senior author, has provided 1277 Oxford assessments.

Results: Mean pre-operative scores were 39.06 and 39.48 for primary and revision THR respectively. The mean annual scores, for primary THR, from 12 to 84 months declined to 21 points at 1 year, 21 at 2 years, 21 at 3 years, 20 at 4 years, 22 at 6 years and 21 at 7 years.

Conclusion: All postoperative reviews show a significant improvement (p≤0.0001). The 50–60 year old group scored significantly better than the over 80 year patients up to 48 months, (p< 0.01) The mean pre-operative score for the NHS patients was significantly higher than the PPs (p< 0.001). The PPs scored significantly better than the NHS group up to 36 months (p< 0.01).