header advert
Results 1 - 50 of 113
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 77 - 77
1 Jul 2022
Sabah S Sina J Alvand A Beard D Price A
Full Access

Abstract

Introduction

Anxiety and depression are risk factors for poor outcome following knee replacement surgery. The aim of this study was to investigate the prevalence of anxiety and depression before and after primary (pKR) and revision knee replacement (rKR).

Methodology

Retrospective cohort study. 315,720 pKR and 12,727 rKR recruited from the NHS Patient Reported Outcome Measures (PROMs) programme from 2013–2021. Anxiety and depression were defined using: (i) Survey question: “Have you been told by a doctor that you have depression? Yes/No”; (ii) EQ-5D anxiety/depression domain. Rates of EQ-5D anxiety/depression were investigated at baseline and at 6-months following surgery. The prevalence of depression was investigated by patient age and gender.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 62 - 62
1 Jul 2022
Sabah S Knight R Alvand A Beard D Price A
Full Access

Abstract

Introduction

Our aim was to investigate trends in the incidence rate and main indication for revision knee replacement (rKR) over the past 15 years in the UK.

Methodology

Cross-sectional study from 2006 - 2020 using data from the National Joint Registry (NJR). Crude incidence rates were calculated using population statistics from the Office for National Statistics.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 6 - 6
1 Jul 2022
Hamilton T Knight R Stokes J Rombach I Cooper C Davies L Dutton S Barker K Cook J Lamb S Murray D Poulton L Wang A Strickland L Duren BV Leal J Beard D Pandit H
Full Access

Abstract

Introduction

This multi-centre randomised controlled trial evaluated the clinical and cost effectiveness of liposomal bupivacaine for pain and recovery following knee replacement.

Methodology

533patients undergoing primary knee replacement were randomised to receive either liposomal bupivacaine (266mg) plus bupivacaine hydrochloride (100mg) or control (bupivacaine hydrochloride 100mg), administered at the surgical site. The co-primary outcomes were pain visual analogue score (VAS) area under the curve (AUC) 6 to 72hours and the Quality of Recovery 40 (QoR-40) score at 72hours.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 58 - 58
1 Jul 2020
Hamilton D Simpson H Beard D Barker K MacFarlane G Stoddart A Murray G
Full Access

There is a lack of evidence as to the best way to deliver rehabilitation following TKA. Previous work has suggested that postoperative physiotherapy applied to all patients is not effective at improving one-year post-surgical outcomes. The aim of this study was to target physiotherapy to those at risk of poor outcome following TKA, and to determine if a therapist-led intervention offered superior results compared to a home-exercise based protocol in this ‘at risk’ group.

The Targeted Rehabilitation to Improve Outcomes (TRIO) study was a prospective randomised controlled trial run at 15-centres in the UK. Patients were identified as ‘potential poor outcome’ based on an Oxford Knee Score (OKS) classification at 6-weeks post-surgery and randomised to either therapist-led or home-exercise based protocols. Patients were reviewed by a physiotherapist and commenced 18-exercise sessions over 6-weeks. The therapist-led group undertook a progressive functional protocol (modified weekly in 1-1 contact sessions) in contrast to the static home-exercise based regime. Evaluation took place following rehabilitation intervention, then at 6-months and 1-year post-surgery. Primary outcome was comparative group OKS at 1-year. Secondary outcomes included, ‘worst’ and ‘average’ pain scores, OXS and EQ-5D, and satisfaction questionnaire. Health economic (cost-utility) analysis was undertaken from NHS perspective up to 1-year post-surgery. Incremental cost per Quality Adjusted Life Years (QALYs) were calculated from intervention costs, patient reported primary and secondary care usage, and EQ-5D data.

4264 patients were screened, 1296 were eligible, 334 patients were randomised, 8 were lost to follow-up, therapy compliance was >85%. Clinically meaningful improvement in OKS (between baseline and 1-year) was seen in both arms (p < 0 .001). Between group difference in 1-year OKS was 1.91 (95%CI, −0.17–3.99) points favouring the therapist-led arm (p=0.07). Incorporating all time point data, between group difference in OKS was 2.25 points (95%CI, 0.61–3.90, p=0.008). Small, non-significant reductions (< 5 %) in both worst and average pain scores were observed favouring the therapist-led group. Enhanced satisfaction with pain relief (OR 1.65, p < 0 .02), ability to perform daily functional tasks (OR 1.66, p < 0 .02), and perform heavy functional tasks (OR 1.6, p=0.04) was reported in the therapist-led group. There was a small non-significant difference of 0.02 points (95%CI −0.02–0.06) between groups in EQ-5D, resulting in a £12,125 cost per QALY of delivering the therapist led intervention with a 57% chance of being cost-effective at the standard UK policy threshold of £20,000 per QALY.

TRIO is the largest randomised trial of physiotherapy following TKA, and the first to target rehabilitation to patients at risk of poor outcomes. Both therapist-led and home-exercise based rehabilitation groups made clinically meaningful improvements in outcome by 1-year. We observed a modest difference in OKS in favour of therapist-led rehabilitation compared to the home-exercises which was not statistically significant. The relatively tight confidence intervals suggests that any difference which might exist is too small to be clinically relevant. Patient satisfaction with outcome was however higher in those that received greater physiotherapist contact. While cost per QALY estimates were below UK policy threshold, this result is uncertain and insufficient to make accept-decline recommendations.


The Bone & Joint Journal
Vol. 102-B, Issue 7 | Pages 950 - 958
1 Jul 2020
Dakin H Eibich P Beard D Gray A Price A

Aims

To assess how the cost-effectiveness of total hip arthroplasty (THA) and total knee arthroplasty (TKA) varies with age, sex, and preoperative Oxford Hip or Knee Score (OHS/OKS); and to identify the patient groups for whom THA/TKA is cost-effective.

Methods

We conducted a cost-effectiveness analysis using a Markov model from a United Kingdom NHS perspective, informed by published analyses of patient-level data. We assessed the cost-effectiveness of THA and TKA in adults with hip or knee osteoarthritis compared with having no arthroplasty surgery during the ten-year time horizon.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_8 | Pages 96 - 96
1 Apr 2017
Sayers A Wylde V Lenguerrand E Gooberman-Hill R Dawson J Beard D Price A Blom A
Full Access

Background

This article reviews four commonly used approaches to assess patient responsiveness to a treatment or therapy [Return To Normal (RTN), Minimal Important Difference (MID), Minimal Clinically Important Difference (MCID), OMERACT-OARSI (OO)], and demonstrates how each of the methods can be formulated in a multi-level modelling (MLM) framework.

Methods

Data from the Arthroplasty Pain Experience (APEX) cohort study was used. Patients undergoing total hip and knee replacement completed the Intermittent and Constant Osteoarthritis Pain (ICOAP) questionnaire prior to surgery and then at 3, 6 and 12 months after surgery. We compare baseline scores, change scores, and proportion of individuals defined as “responders” using traditional and multi-level model (MLM) approaches to patient responsiveness.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 49 - 49
1 Jan 2016
Monk A Mellon S Chen M Beard D Gill H Murray D
Full Access

Introduction

Knee arthroplasty is an effective intervention for painful arthritis when conservative measures have failed. Despite recent advances in component design and implantation techniques, a significant proportion of patients experience problems relating to the patella-femoral joint (PFJ).

Detailed knowledge of the shape and orientation of the normal and replaced femoral trochlea groove is critical when considering potential causes of anterior knee pain. Furthermore, to date it has proved difficult to establish a diagnosis due to shortcomings in current imaging techniques for obtaining satisfactory coronal plane motion data of the patella in the replaced knee.

The aim of this study was to correlate the trochlea shape of normal and replaced knees with corresponding coronal plane PFJ kinematic data.

Method

Bony and cartilagenous trochlea geometries from 3T MRI scans of 20 normal healthy volunteers were compared with both anatomical and standard total knee replacements (TKR) and patellofemoral joint replacement (PFJR) geometries. Following segmentation and standardized alignment, the path of the apex of the trochlea groove was measured using customized Matlab software. (Fig1).

Next, kinematic data of the 20 normal healthy volunteers (Normal) was compared with that of 20 TKR, and 20 PFJR patients using the validated MAUSTM system (Motion Analysis and UltraSound) comprising a 12-camera, motion capture system used to capture images of reflective markers mounted on subjects lower limbs and an ultrasound probe. A mapping between the ultrasound image and the motion capture system allows the ultrasound probe to be used to determine the locations of the patella relative to bony landmarks on the femur during a squat exercise.


The Bone & Joint Journal
Vol. 97-B, Issue 4 | Pages 510 - 515
1 Apr 2015
Hutchison AM Topliss C Beard D Evans RM Williams P

The Swansea Morriston Achilles Rupture Treatment (SMART) programme was introduced in 2008. This paper summarises the outcome of this programme. Patients with a rupture of the Achilles tendon treated in our unit follow a comprehensive management protocol that includes a dedicated Achilles clinic, ultrasound examination, the use of functional orthoses, early weight-bearing, an accelerated exercise regime and guidelines for return to work and sport. The choice of conservative or surgical treatment was based on ultrasound findings.

The rate of re-rupture, the outcome using the Achilles Tendon Total Rupture Score (ATRS) and the Achilles Tendon Repair Score, (AS), and the complications were recorded. An elementary cost analysis was also performed.

Between 2008 and 2014 a total of 273 patients presented with an acute rupture 211 of whom were managed conservatively and 62 had surgical repair. There were three re-ruptures (1.1%). There were 215 men and 58 women with a mean age of 46.5 years (20 to 86). Functional outcome was satisfactory. Mean ATRS and AS at four months was 53.0 (sd 14), 64.9 (sd 15) (n = 135), six months 67.8 (sd 16), 73.8 (sd 15) (n = 103) and nine months (72.4; sd 14) 72.3 (sd 13) (n = 43). The programme realised estimated cost savings exceeding £91 000 per annum.

The SMART programme resulted in a low rate of re-rupture, a satisfactory outcome, a reduced rate of surgical intervention and a reduction in healthcare costs.

Cite this article: Bone Joint J 2015; 97-B:510–15.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_2 | Pages 23 - 23
1 Jan 2014
Hutchinson A Beard D Evans R Topliss C Williams P
Full Access

Introduction:

Historically the incidence of Achilles re-ruptures has been described as around 5% after surgical repair and up to 21% after conservative management. In 2008 we commenced a dedicated Achilles tendon rupture clinic for both conservative and surgically managed patients using new standardised operating procedures (SOP). We have evaluated the impact of this new service, particularly with regard to re-rupture rate.

Materials and methods:

The SOP was stage dependent and included an initial ultrasound examination, functional orthotics with early weight bearing, accelerated exercise and guidelines for the return to work and sport. Evaluation included re-rupture rate, complication rate, and outcome measured by the Achilles Tendon Total Rupture Score (ATRS) and Achilles Tendon Repair Score (AS). A basic cost evaluation was performed to assess any potential savings.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_26 | Pages 10 - 10
1 Jun 2013
Monk A Chen M Mellon S Gibbons M Beard D Murray D Gill H
Full Access

Previous attempts to measure coronal plane patellofemoral kinematics following knee replacement have suffered from methodological drawbacks; the patella being obscured by the components, metal artefact and technical inaccuracies. The aim of this study was to assess whether there was any significant difference in the patellofemoral kinematics between normal, TKR and PFJR patients using the validated MAUS™ technique (combining motion analysis with ultrasound).

60 patients were recruited into three groups; normal healthy volunteers (Normal), TKR, and PFJR patients. The MAUS technique incorporates a 12 camera analysis system (providing gross alignment data for tibial and femoral segments) and an ultrasound probe (providing coordinates of bony landmarks on patella femur and tibia) during a squat exercise. 6 DOF kinematics were described between 0 and 90° flexion. The validated accuracy of the MAUS technique registering the ultrasound images within the motion capture system is 1.84 mm (2 × SD).

Movements of the Normal group were significantly different from the TKR group (p=0.03) and the PFJR group (p<0.01), whilst there was no significant difference between the TKR and PFJR groups (p=0.27).

Our data suggest that many aspects of patellofemoral kinematics are absent following TKR and PFJR, which could be addressed in future designs of knee TKR and PFJR.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 35 - 35
1 Jan 2013
Williams D Price A Beard D Hadfield S Arden N Murray D Field R
Full Access

Objectives

This study examines variations in knee arthroplasty patient reported outcome measures according to patient age.

Methods

We analysed prospectively collected outcome data (OKS, Eq5D, satisfaction, and revision) on 2456 primary knee arthroplasty patients. Patients were stratified into defined age groups (< 55, 55–64, 65–74, 75–84, and ≥85 years). Oxford Knee Score and Eq5D were analysed pre-operatively, and postoperatively at 6 months and 2 years. Absolute scores and post-operative change in scores were calculated and compared between age groups. Satisfaction scores (0–100) were analysed at 6 months post-operatively. Linear, logistic and ordinal regression modelling was used to describe the association between age and outcomes, for continuous, binary and ordinal outcomes, respectively. Kaplan-Meier analysis was performed to describe revision rates at 2 years.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIII | Pages 19 - 19
1 Sep 2012
Hutchison A Topliss C Williams P Pallister I Beard D
Full Access

Introduction

Chronic mid body Achilles tendinopathy is a common problem. There is no consensus on treatment. The aim of this review was to assess the effectiveness of physiotherapy interventions (non surgical and non pharmacological) for this condition.

Methods

A systematic review of the literature was conducted. A search of published and grey literature databases was undertaken (1999- December 2010). Two reviewers independently assessed the studies for eligibility using a strict inclusion and exclusion criteria. All eligible articles were assessed critically using the Pedro score. Data on cohort characteristics, diagnostic criteria, treatment intervention, outcome measures and results was extracted. A narrative research synthesis method was adopted.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 14 - 14
1 Sep 2012
Hossain M Beard D Andrew G
Full Access

Introduction

There is uncertainty about the relationship between improvement in range of motion (ROM) and functional outcome or patient satisfaction after total hip arthroplasty (THA). Using data from a prospective multi-centre study we investigated this relationship.

Methods

We recorded the Oxford Hip Score (OHS), Merle d'Aubigne and Postel score (MDA) and range of motion (ROM) preoperatively and at one and five years and a patient satisfaction questionnaire at five years. Complete 5 year data were available for 342 patients.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 241 - 241
1 Sep 2012
Khan T Jackson W Beard D Ahmad M Spacie R Jones R Barker K Price A
Full Access

Background

Despite interest, the current rate of day-case anterior cruciate ligament reconstruction (ACLR) in the UK remains low. Although specialised care pathways with standard operating procedures (SOPs) have been effective in reducing length of stay following some surgical procedures, this has not been previously reported for ACLR. We evaluate the effectiveness of SOPs for establishing day-case ACLR in a specialist unit.

Methods

Fifty patients undergoing ACLR between May and September 2010 were studied prospectively (“study group”). SOPs were designed for pre-operative assessment, anaesthesia, surgical procedure, mobilisation and discharge. We evaluated length of stay, readmission rates, patient satisfaction and compliance to SOPs. A retrospective analysis of 50 patients who underwent ACLR prior to implementation of the day-case pathway was performed (“standard practice group”).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 19 - 19
1 Sep 2012
Barlow D Andrew G Badr S Rhee S Beard D Murray D
Full Access

We examined data from a large prospectively collected dataset which followed up patients after Exeter total hip replacement (THR) - the Exeter Primary Outcome Study. We studied 78 patients who had total hip replacement for osteoarthritis on a morphologically normal hip, and in whom the other hip was also morphologically normal for comparison. All selected patients had complete patient outcome data at 1 and 5 years, and x-rays at 1 year were available.

We measured accuracy of reconstruction on AP Pelvis radiographs. The parameters measured were difference in height of lesser trochanter from horizontal pelvic line (LLD); length from ASIS to greater trochanter (indicating abductor length, AL); length from symphysis to centre of femoral head (SFH); length from centre of head to axis of femur (offset). We examined clinical outcomes including gain of Oxford Hip Score (DOHS) at 1 and 5 years, absolute OHS at 1 and 5 years, and absolute SF-36 Physical Functioning and Role Physical scores at 1 and 5 years.

Examining the ratios of AL, SFH, Offset, Offset to SFH ratio and LLD between side of THR and unaffected side all showed marked variation. Thus the ratio of SFH varied from 0.85 to 1.11. For further analysis we divided the patients into 3 groups on the basis of variability of the ratio from 1; we examined whether the clinical scores above varied between these 3 groups. 1 way ANOVA demonstrated no significant difference for any of the clinical outcomes for any of the 5 grouped x-ray variables.

Accuracy of reconstruction has been shown to affect the risk of dislocation after THR. Our results indicate that clinical outcomes of total hip replacement appear resilient to some degree of surgical inaccuracy. Future trials of navigation should be designed to demonstrate not only improved accuracy but also improved clinical outcome.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 213 - 213
1 Sep 2012
Ashmore A Beard D Price A Gill H
Full Access

Aims

Interest in soft tissue Radiostereometric Analysis (RSA) is rising. Previous authors have tried, with varying levels of success, to use this technique to analyse the intra-substance portion of anterior cruciate ligament (ACL) graft constructs. These methods were either prone to large amounts of marker migration, deemed unsuitable for in-vivo use or, where alternative markers such as stainless steel sutures were used, lost the inherent accuracy that made RSA an attractive tool in the first place. We describe a modification of tantalum marker balls that allows for a new method of secure fixation to soft tissue in order to accurately analyse stretch, displacement and, potentially, dynamic movement using RSA.

Methods

1.5 mm tantalum tendon markers were predrilled with 0.3 mm holes, allowing them to be sutured directly to soft tissue. Using a previously described ACL graft model, the amount of marker ball migration was then analysed using RSA after cyclical loading between 20 N and 170 N at 25 Hz for 225,000 cycles.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 263 - 263
1 Sep 2012
Monk A Grammatopoulos G Chen M Gibbons M Beard D Gill H Murray D
Full Access

Introduction

Osteoarthritis (OA) of the hip is an important cause of pain and morbidity. The mechanisms and pathogenesis of OA'sdevelopment remain unknown. Minor acetabular dysplasia and subtle variations in proximal femoral morphology are increasingly being recognized as factors that potentially compromise the joint biomechanically and lead to OA. Previous studies have shown that risk of hip OA increased as the femoral head to femoral neck ratio (HNR) decreased. Previous work has described the evolutionary change in inferior femoral neck trabecular density and geometry associated with upright stance, but no study has highlighted the evolutionary change in HNR. The aim of this study was to examine evolutionary evidence that the hominin bipedal stance has lead to alterations in HNR that would predispose humans to hip OA.

Methods

A collaboration with The Natural History Museums of London, Oxford and the Department of Zoology, University of Oxford provided specimens from the Devonian, Jurassic, Cretaceous, Miocene, Palaeolithic and Pleistocene periods to modern day. Specimens included amphibious reptiles, dinosaurs, shrews, tupaiae, lemurs, African ground apes, Lucy (A. Afarensis), H. Erectus, H. Neaderthalis and humans. Species were grouped according to gait pattern; HAKF (hip and knee flexed), Arboreal (ability to stand with hip and knee joints extended) and hominin/bi-pedal. Imaging of specimens was performed using a 64 slice CT scanner. Three-dimensional skeletal geometries were segmented using MIMICS software. Anatomical measurements from bony landmarks were performed to describe changes in HNR, in the coronal plane of the different specimens over time using custom software. Measurements of HNR from the specimens were compared with HNR measurements made from AP pelvic radiographs of 119 normal subjects and 210 patients with known hip OA listed for hip arthroplasty.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 509 - 509
1 Sep 2012
Thomas G Hossain M Monk A Gill H Glyn-Jones S Andrew J Murray D Beard D Epos Group N
Full Access

Introduction

Malalignment of some designs of stem is associated with an increased risk of aseptic loosening and revision. We investigated whether the alignment of the cemented polished, double-taper design adversely affected outcome, in a multicentre prospective study.

Methods

A multicentre prospective study of 1189 total hip replacements was undertaken to investigate whether there is an association between surgical outcome and femoral stem alignment. All patients underwent a primary THR with the Exeter femoral stem (Stryker Howmedica Osteonics, Mahwah, NJ) and a variety of acetabular components. The primary outcome measure was the Oxford hip score (OHS) and change in OHS at five years. Secondary outcomes included rate of dislocation and revision. Radiographic evaluation of the femoral component was also undertaken. The long axis of the Exeter femoral component and the long axis of the femoral canal were located, and the angle at the point of intersection measured. The cementing quality was determined as defined by Barrack et al. Radiolucent lines at the cement-stem and cement-bone interface in the five year radiographs were defined using the zones described by Gruen et al. Subsidence was measured as the vertical dimension of the radiolucency craniolateral to the shoulder of the stem in Gruen zone 1 as described by Fowler et al. Cement fractures were recorded.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 422 - 422
1 Sep 2012
Weston-Simons J Pandit H Kendrick B Beard D Gibbons M Jackson W Gill H Price A Dodd C Murray D
Full Access

Introduction

The options for the treatment of the young active patient with unicompartmental symptomatic osteoarthritis and pre-existing Anterior Cruciate Ligament (ACL) deficiency are limited. Patients with ACL deficiency and end-stage medial compartment osteoarthritis are usually young and active. The Oxford Unicompartmental Knee Replacement (UKA) is a well established treatment option in the management of symptomatic end-stage medial compartmental osteoarthritis, but a functionally intact ACL is a pre-requisite for its satisfactory outcome. If absent, high failure rates have been reported, primarily due to tibial loosening. Previously, we have reported results on a consecutive series of 15 such patients in whom the ACL was reconstructed and patients underwent a staged or simultaneous UKA. The aim of the current study is to provide an update on the clinical and radiological outcomes of a large, consecutive cohort of patients with ACL reconstruction and UKA for the treatment of end-stage medial compartment osteoarthritis and to evaluate, particularly, the outcome of those patients under 50.

Methods

This study presents a consecutive series of 52 patients with ACL reconstruction and Oxford UKA performed over the past 10 years (mean follow-up 3.4 years). The mean age was 51 years (range: 36–67). Procedures were either carried out as Simultaneous (n=34) or Staged (n=18). Changes in clinical outcomes were measured using the Oxford Knee Score (OKS), the change in OKS (OKS=Post-op − Pre-op) and the American Knee Society Score (AKSS). Fluoroscopy assisted radiographs were taken at each review to assess for evidence of loosening, radiolucency progression, (if present), and component subsidence.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 12 - 12
1 Sep 2012
Hossain M Beard D Murray D Andrew G
Full Access

Introduction

Acetabular cup lucency predicts cup survival. The relationship of subchondral plate removal and cup survival is unclear. Using data from a prospective study conducted between January 1999 and January 2002 we investigated the role of subchondral plate removal in cemented acetabular cup survival at five years.

Methods

A number of cemented cups were implanted using antero-lateral and posterior approaches.1400 cups were inserted. 935 cups (67%) were followed up at 5 years and acetabular radiolucency (AR) recorded.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 584 - 584
1 Sep 2012
Grammatopoulos G Thomas G Pandit H Glyn-Jones S Gill H Beard D Murray D
Full Access

INTRODUCTION

The introduction of hard-on-hard bearings and the consequences of increased wear due to edge-loading have renewed interest in the importance of acetabular component orientation for implant survival and functional outcome following hip arthroplasty. Some studies have shown increased dislocation risk when the cup is mal-oriented which has led to the identification of a safe-zone1. The aims of this prospective, multi-centered study of primary total hip arthroplasty (THA) were to: 1. Identify factors that influence cup orientation and 2. Describe the effect of cup orientation on clinical outcome.

METHODS

In a prospective study involving seven UK centers, patients undergoing primary THA between January 1999 and January 2002 were recruited. All patients underwent detailed assessment pre-operatively as well as post-op. Assessment included data on patient demographics, clinical outcome, complications and further surgery/revision. 681 primary THAs had adequate radiographs for inclusion. 590 hips received cemented cups. The primary functional outcome measure of the study was the change between pre-operative and at latest follow up OHS (OHS). Secondary outcome measures included dislocation rate and revision surgery. EBRA was used to determine acetabular inclination and version.

The influence of patient's gender, BMI, surgeon's grade and approach on cup orientation was examined. Four different zones tested as possibly ± (Lewinnek Zone, Callanan's described zone and zones ± 5 and ±10 about the study's mean inclination and anteversion) for a reduced dislocation risk and an optimal functional outcome.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXII | Pages 21 - 21
1 Jul 2012
Monk A Grammatopoulos G Chen M Gibbons C Beard D Murray D Gill H
Full Access

A femoral head/neck ratio (HNR) of less than 1.27 is associated with an increased risk of arthritis. The aim of this study was to establish whether there is evolutionary evidence that the homonin, bipedal stance has led to alterations in HNR that predispose humans to osteoarthritis (OA).

Specimens provided by The Natural History Museums of London, Oxford and the Department of Zoology, University of Oxford were grouped according to gait pattern, HAKF (Hip and knee flexed), Arboreal (ability to stand with hip and knee joints extended) and homonin/bi-pedal. Specimens included those from Devonion, Triassic, Jurrasic, Cretaceous, Miocene, Paleolithic, Pleistocene periods to modern day. Three-dimensional skeletal geometries were segmented using CT images and HNR measurements were taken from coronal views. These were compared with the HNR of 119 asymptomatic human volunteers and 210 patients that had a hip joint replacement for primary OA.

Species of the HAKF group had the smallest HNR (1.10, SD:0.09). Species of the Arboreal group had significantly higher HNR (1.63, SD:0.15) in comparison to the Bipedal group (1.41, SD:0.04) (p=0.006), Human (1.33, SD:0.08) and the OA group (1.3, SD:0.09).

The range of movement associated with arboreal habitat caused an associated change in HNR. This study would suggest that the HNR peaked in the Miocene period with species that ambulated on both ground and trees. More recent homonin gait appears to have developed a smaller HNR and humans have the smallest amongst their close ancestors. Evolutionary theory would suggest that modern environmental pressures might pre-dispose future hominin evolution to OA, secondary to a further reduction in HNR.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 92 - 92
1 Jul 2012
Mehmood S Batta V Gulati A Pandit H Bottomley N Gil H Beard D Dodd C Jackson W Murray D Price A
Full Access

INTRODUCTION

Establishing a full-thickness cartilage in the lateral compartment and functionally intact ACL is vital before proceeding with unicompartmental knee replacement (UKR). The aim of this study is to assess whether MRI is a useful adjunct in predicting suitability for UKR, as compared to standard and stress radiographs.

METHODS

We identified 50 patients with a knee found suitable for UKR based on their standard and stress radiographs (full-thickness cartilage on lateral side). These patients underwent an additional cartilage-specific MRI scan to identify the status of ACL and the lateral compartment. The final decision regarding the suitability for UKR was based on the intra-operative observation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 71 - 71
1 Jul 2012
Beard D Holt M Mullins M Massa E Malek S Price A
Full Access

Purpose

Late stage medial unicompartmental osteoarthritic disease of the knee can be treated by either Total Knee Replacement (TKR) or Unicompartmental Replacement (UKR). As a precursor to the TOPKAT study this work tested the postulate that individual surgeons show high variation in the choice of treatment for individual patients.

Method

Four surgeons representing four different levels of expertise or familiarity with partial knee replacement (UKR design centre knee surgeon, specialist knee surgeon, arthroplasty surgeon and a year six trainee) made a forced choice decision of whether they would perform a TKR or UKR based on the same pre-operative radiographic and clinical data in 140 individual patients. Consistency of decision was also evaluated for each surgeon 3 months later and the effect of additional clinical data was also evaluated. The sample consisted of the 100 patients who had subsequently undergone UKR and 40 who had undergone TKR.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 107 - 107
1 Jul 2012
Williams D Beard D Arden N Field R Price A
Full Access

Purpose

To examine the clinical characteristics of patients undergoing knee arthroplasty with a pre-operative Oxford Knee Score >34 (‘good’/‘excellent’), and assess the appropriateness of surgical intervention for this group.

Background

In the current cost-constrained health economy, justification of surgical intervention is increasingly sought. As a validated disease-specific outcome measure, the pre-operative Oxford Knee Score (OKS) has been suggested as a possible threshold measurement in knee arthroplasty. However, contrary to expectations, analysis of pre-operative OKS in the joint registry population demonstrates a normal distribution curve with a sub-group of high-scoring patients. This suggests that either the baseline OKS does not accurately define surgical threshold, or that patients with a high OKS are inappropriately having knee replacements.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 43 - 43
1 Jul 2012
Price A Jackson W Field R Judge A Carr A Arden N Murray D Dawson J Beard D
Full Access

Purpose

The Oxford Knee Score (OKS) is a validated and widely used PROM that has been successfully used in assessing the outcome of knee arthroplasty (KA). It has been adopted as the nationally agreed outcome measure for this procedure and is now routinely collected. Increasingly, it is being used on an individual patient basis as a pre-operative measure of osteoarthritis and the need for joint replacement, despite not being validated for this use. The aim of this paper is to present evidence that challenges this new role for the OKS.

Method

We have analysed pre-operative and post-operative OKS data from 3 large cohorts all undergoing KA, totalling over 3000 patients. In addition we have correlated the OKS to patient satisfaction scores. We have validated our findings using data published from the UK NJR.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 64 - 64
1 Jul 2012
Al-Ali S Khan T Jackson W Beard D Price A
Full Access

Purpose

The purpose was to determine if the use of cold irrigation fluid in routine knee arthroscopy leads to a reduction in post operative pain.

Background

Some surgeons use cooled irrigation fluid in knee arthroscopy in the hope that it may lead to a reduction in post operative pain and swelling. There is currently no evidence for this, although there is some evidence to support the use of cold therapy post operatively in knee surgery.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVII | Pages 11 - 11
1 May 2012
Hossain M Parfitt D Beard D Darrah C Nolan J Murray D Andrew J
Full Access

Introduction

Preoperative psychological distress has been reported to predict poor outcome and patient dissatisfaction after total hip replacement (THR). We investigated this relationship in a prospective multi-centre study between January 1999 and January 2002.

Methods

We recorded the Oxford Hip Score (OHS) and SF36 score preoperatively and up to five years after surgery and a global satisfaction questionnaire at five year follow up for 1039 patients. We dichotomised the patients into the mentally distressed (Mental Health Scale score - MHS <50) and the not mentally distressed (MHS (50) groups based on their pre-operative MHS of the SF36. 776 (677 not distressed and 99 distressed) out of 1039 patients were followed up at 5 years.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 47 - 47
1 May 2012
Bottomley N McNally E Jones L Javaid M Arden N Gill H Dodd C Murray D Beard D Price A
Full Access

Introduction

Anteromedial osteoarthritis of the knee (anteromedial gonarthrosis-AMG) is a common form of knee arthritis. In a clinical setting, knee arthritis has always been assessed by plain radiography in conjunction with pain and function assessments. Whilst this is useful for surgical decision making in bone on bone arthritis, plain radiography gives no insight to the earlier stages of disease. In a recent study 82% of patients with painful arthritis had only partial thickness joint space loss on plain radiography. These patients are managed with various surgical treatments; injection, arthroscopy, osteotomy and arthroplasty with varying results. We believe these varying results are in part due to these patients being at different stages of disease, which will respond differently to different treatments. However radiography cannot delineate these stages. We describe the Magnetic Resonance Imaging (MRI) findings of this partial thickness AMG as a way of understanding these earlier stages of the disease.

Method

46 subjects with symptomatic partial thickness AMG underwent MRI assessment with dedicated 3 Tesla sequences. All joint compartments were scored for both partial and full thickness cartilage lesions, osteophytes and bone marrow lesions (BML). Both menisci were assessed for extrusion and tear. Anterior cruciate ligament (ACL) integrity was also assessed. Osteophytes were graded on a four point scale in the intercondylar notch and the lateral margins of the joint compartments. Scoring was performed by a consultant radiologist and clinical research fellow using a validated MRI atlas with consensus reached for disagreements. The results were tabulated and relationships of the interval data assessed with linear by linear Chi2 test and Pearson's Correlation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 24 - 24
1 May 2012
Bottomley N Javaid M Gill H Dodd C Murray D Beard D Price A
Full Access

Introduction

Anteromedial gonarthrosis is a common well described pattern of knee osteoarthritis with cartilage wear beginning in the anteromedial quadrant of the medial tibial plateau in the presence of an intact and functioning ACL. It is well known that mechanical factors such as limb alignment and meniscal integrity affect the progression of arthritis and there is some evidence that the morphology of the tibial plateau may be a risk factor in the development of this disease. The extension facet angle is the angle of the downslope of the anterior portion of the medial tibial plateau joint surface in relation to the middle portion on a sagittal view. If this is an important factor in the development of AMG there may be potential for disease modifying intervention.

This study investigates if there is a significant difference in this angle as measured on MRI between a study cohort with early AMG (partial thickness cartilage damage and intact ACL) and a comparator control cohort of patients (no cartilage damage and ACL rupture).

Methods

3 Tesla MRI scans of 99 patients; 54 with partial thickness cartilage damage and 44 comparitors with no cartilage damage (acute ACL rupture) were assessed. The extension facet angle was measured (Osirix v3.6) using a validated technique on two consecutive MRI T2 sagittal slices orientated at the mid-coronal point of the medial femoral condyle. (InterClass Correlation 0.95, IntraClass Correlation 0.97, within subject variation of 1.1° and coefficient of variation 10.7%). The mean of the two extension angle values was used. The results were tabulated and analysed (R v2.9.1).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XVIII | Pages 96 - 96
1 May 2012
Monk A McKenna D Simpson D Beard D Thomas N Gill H
Full Access

The heat produced by drills, saws and PMMA cement in the handling of bone can cause thermal necrosis. Thermal necrosis could be a factor in the formation of a fibrous tissue membrane and impaired bony ingrowth into porous prostheses. This has been proposed to lead to non-union of osteotomies and fractures, the failure of the bone-cement interface and the failure of resurfacing arthroplasty.

We compared three proprietary blades (the De Soutter, the Stryker Dual Cut and the Stryker Precision) in an in-vitro setting with porcine tibiae, using thermocouples embedded in the bone below the cutting surface to measure the increases in bone temperature.

There was a significant (p=0.001) difference in the change in temperature (δT) between the blade types. The mean increase in temperature was highest for the De Soutter, 2.84°C (SD: 1.83°C, range 0.48°C to 9.30°C); mean δT was 1.81°C (SD: 1.00°C, range 0.18°C to 4.85°C) for the Precision and 1.68°C (SD: 0.95°C, range 0.24°C to 5.67°C). Performing paired tests, there was no significant difference in δT between the Precision and Dual Cut blades (p=0.340), but both these blades had significantly (p=0.003 for Precision vs De Soutter, p<0.001 for Dual Cut vs De Soutter) lower values for δT than the Dual Cut.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 25 - 25
1 Mar 2012
Pandit H Jenkins C Gill H Beard D Price A Dodd C Murray D
Full Access

Introduction

The results of the mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing with a five year survival of 82%. Therefore, it is recommended that mobile bearings should not be used for lateral UKR. This low survivorship is primarily due to high dislocation rate, all occurring in the first year. A detailed analysis of the causes of bearing dislocation confirmed the elevated lateral tibial joint line to be a contributory factor. A new surgical technique was therefore introduced in which care was taken neither to remove too much bone from distal femur nor to over tighten the knee and thus ensure that the tibial joint line was not elevated. Other modifications to the technique were also introduced including use of a domed tibial component.

Aim

The aim of this study is to compare the outcome of these iterations: the original series [series I], Series II with improved surgical technique and the domed tibial component [Series III].


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 19 - 19
1 Mar 2012
Bottomley N Kendrick B Ferguson J Al-Ali S Dodd C Murray D Beard D Price A
Full Access

Introduction

Total knee arthroplasty (TKA) accounts for 84% of all knee replacement surgery in the UK (NJR 2009) despite published epidemiological data showing that single compartment disease is most prevalent. We investigated this incompatibility further by describing the compartmental pattern and stage of cartilage loss of all patients with osteoarthritis (OA) presenting to a specialist knee clinic over one year.

Methods

All new primary referrals in a calendar year by local General Practitioners to knee clinic at a United Kingdom Hospital were assessed. Tertiary referrals and second opinions were excluded. The final diagnosis after all imaging was recorded and tabulated. The standing AP, lateral and skyline radiographs of all cases of arthritis were scored to assess the pattern of disease.


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 3 | Pages 412 - 418
1 Mar 2012
Judge A Arden NK Kiran A Price A Javaid MK Beard D Murray D Field RE

We obtained information from the Elective Orthopaedic Centre on 1523 patients with baseline and six-month Oxford hip scores (OHS) after undergoing primary hip replacement (THR) and 1784 patients with Oxford knee scores (OKS) for primary knee replacement (TKR) who completed a six-month satisfaction questionnaire.

Receiver operating characteristic curves identified an absolute change in OHS of 14 points or more as the point that discriminates best between patients’ satisfaction levels and an 11-point change for the OKS. Satisfaction is highest (97.6%) in patients with an absolute change in OHS of 14 points or more, compared with lower levels of satisfaction (81.8%) below this threshold. Similarly, an 11-point absolute change in OKS was associated with 95.4% satisfaction compared with 76.5% below this threshold. For the six-month OHS a score of 35 points or more distinguished patients with the highest satisfaction level, and for the six-month OKS 30 points or more identified the highest level of satisfaction. The thresholds varied according to patients’ pre-operative score, where those with severe pre-operative pain/function required a lower six-month score to achieve the highest levels of satisfaction.

Our data suggest that the choice of a six-month follow-up to assess patient-reported outcomes of THR/TKR is acceptable. The thresholds help to differentiate between patients with different levels of satisfaction, but external validation will be required prior to general implementation in clinical practice.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 31 - 31
1 Mar 2012
Kendrick B Pandit H Jenkins C Beard D Gill H Price A Dodd C Murray D
Full Access

Purpose of Study

To assess the incidence of radiolucency in cemented and cementless Oxford unicompartmental knee replacement at two years.

Introduction

Most unicompartmental knee replacements (UKRs) employ cement for fixation of the prosthetic components. The information in the literature about the relative merits of cemented and cementless UKR is contradictory, with some favouring cementless fixation and others favouring cemented fixation. In addition, there is concern about the radiolucency that frequently develops beneath the tibial component with cemented fixation. The exact cause of the occurrence of radiolucency is unknown but it has been hypothesised that it may suggest suboptimal fixation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_II | Pages 13 - 13
1 Feb 2012
Steffen R Smith S Gill H Beard D McLardy-Smith P Urban J Murray D
Full Access

This study aims to investigate femoral blood flow during Metal-on-Metal Hip Resurfacing (MMHR) by monitoring oxygen concentration during the operative procedure.

Patients undergoing MMHR using the posterior approach were evaluated. Following division of fascia lata, a calibrated gas-measuring electrode was inserted into the femoral neck, aiming for the supero-lateral quadrant of the head. Baseline oxygen concentration levels were detected after electrode insertion 2-3cm below the femoral head surface and all intra-operative measures were referenced against these. Oxygen levels were continuously monitored throughout the operation. Data from ten patients are presented.

Oxygen concentration dropped most noticeably during the surgical approach and was reduced by 62% (Std.dev +/-26%) following dislocation and capsulectomy. Insertion of implants resulted in a further oxygenation decrease by 18% (Std.dev +/-28%). The last obtained measure before wound closure detected 22% (Std.dev +/-31%) of initial baseline oxygen levels. Variation between subjects was observed and three patients demonstrated a limited recovery of oxygen levels during implant insertion and hip relocation.

Intra-operative measurement of oxygen concentration in blood perfusing the femoral head is feasible. Results in ten patients undergoing MMHR showed a dramatic effect on the oxygenation in the femoral head during surgical approach and implant fixation. This may increase the risk of avascular necrosis and subsequent femoral neck fracture. Future experiments will determine if less invasive procedures or specific positioning of the limb can protect the blood supply to femoral neck and head.


The Journal of Bone & Joint Surgery British Volume
Vol. 93-B, Issue 12 | Pages 1660 - 1664
1 Dec 2011
Judge A Arden NK Price A Glyn-Jones S Beard D Carr AJ Dawson J Fitzpatrick R Field RE

We obtained pre-operative and six-month post-operative Oxford hip (OHS) and knee scores (OKS) for 1523 patients who underwent total hip replacement and 1784 patients who underwent total knee replacement. They all also completed a six-month satisfaction question.

Scatter plots showed no relationship between pre-operative Oxford scores and six-month satisfaction scores. Spearman’s rank correlation coefficients were -0.04 (95% confidence interval (CI) -0.09 to 0.01) between OHS and satisfaction and 0.04 (95% CI -0.01 to 0.08) between OKS and satisfaction. A receiver operating characteristic (ROC) curve analysis was used to identify a cut-off point for the pre-operative OHS/OKS that identifies whether or not a patient is satisfied with surgery. We obtained an area under the ROC curve of 0.51 (95% CI 0.45 to 0.56) for hip replacement and 0.56 (95% CI 0.51 to 0.60) for knee replacement, indicating that pre-operative Oxford scores have no predictive accuracy in distinguishing satisfied from dissatisfied patients.

In the NHS widespread attempts are being made to use patient-reported outcome measures (PROMs) data for the purpose of prioritising patients for surgery. Oxford hip and knee scores have no predictive accuracy in relation to post-operative patient satisfaction. This evidence does not support their current use in prioritising access to care.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 221 - 222
1 May 2011
Kwon Y Glyn-Jones S Simpson D Kamali A Counsell L Mclardy-Smith P Beard D Gill H Murray D
Full Access

Introduction: Pseudotumours (soft-tissue masses relating to the hip joint) following metal-on-metal hip resurfacing arthroplasty (MoMHRA) have been associated with elevated serum and hip aspirate metal ion levels, suggesting that pseudotumours occur when there is increased wear. This study aimed to quantify in vivo wear of implants revised for pseudotumours and a control group of implants revised for other reasons of failure.

Methods: A total of 30 contemporary MoMHRA implants in two groups were investigated in this Institutional Review Board approved study:

8 MoMHRA implants revised due to pseudotumour;

22 MoMHRA implants revised due to other reasons of failure (femoral neck fracture and infection).

The linear wear of retrieved implants was measured using a Taylor-Hobson Roundness machine. The average linear wear rate was defined as the maximum linear wear depth divided by the duration of the implant in vivo.

Results: In comparison with the non-pseudotumour implant group, the pseudotumour implant group was associated with:

significantly higher median linear wear rate of the femoral component: 8.1um/year (range 2.75–25.4um/year) vs. 1.79um/year (range 0.82–4.15um/year), p=0.002; and

significantly higher median linear wear rate of the acetabular component: 7.36um/year (range1.61–24.9um/year) vs. 1.28um/year (range 0.18–3.33um/year), p=0.001.

Similarly, differences were also measured in absolute wear values. The median absolute linear wear was significantly higher in the pseudotumour implant group:

21.05um (range 2.74–164.80um) vs. 4.44um (range 1.50–8.80um) for the femoral component, p=0.005; and

14.87um (range 1.93–161.68um) vs. 2.51um (range 0.23–6.04um) for the acetabular component, p=0.008.

Wear on the acetabular cup components in the pseudotumour group always involved the edge, indicating edge-loading of the bearing. In contrast, edge-loading was observed in only one acetabular component in the non-pseudotumour group of implants. The deepest wear was observed well within the bearing surface for the rest of the non-pseudotumour group. The difference in the incidence of edge-loading between the two groups was statistically significant (Fisher’s exact test, p=0.03).

Discussion: Significantly greater linear wear rates of the MoMHRA implants revised due to pseudotumour support the in vivo elevated metal ion concentrations in patients with pseudotumours. This study provides the first direct evidence to confirm that pseudotumour is associated with increased wear at the MoM articulation. Furthermore, edge-loading with the loss of fluid film lubrication may be the dominant wear generation mechanism in patients with pseudotumour.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 96 - 96
1 May 2011
Bottomley N Javaid M Judge A Gill H Murray D Beard D Price A
Full Access

Introduction: Anteromedial gonarthrosis is a common well described pattern of knee osteoarthritis with cartilage wear beginning in the anteromedial quadrant of the medial tibial plateau in the presence of an intact and functioning ACL. It is well known that mechanical factors such as limb alignment and meniscal integrity affect the progression of arthritis and there is some evidence that the morphology of the tibial plateau may be a risk factor in the development of this disease. The extension facet angle is the angle of the downslope of the anterior portion of the medial tibial plateau joint surface in relation to the middle portion on a sagittal view. If this is an important factor in the development of AMG there may be potential for disease modifying intervention.

This study investigates if there is a significant difference in this angle as measured on MRI between a study cohort with early AMG (partial thickness cartilage damage and intact ACL) and a comparator control cohort of patients (no cartilage damage and ACL rupture).

Methods: 3 Tesla MRI scans of 99 patients; 54 with partial thickness cartilage damage and 44 comparitors with no cartilage damage (acute ACL rupture) were assessed. The extension facet angle was measured (Osirix v3.6) using a validated technique on two consecutive MRI T2 sagittal slices orientated at the mid-coronal point of the medial femoral condyle. (InterClass Correlation 0.95, IntraClass Correlation 0.97, within subject variation of 1.1° and coefficiant of variation 10.7%). The mean of the two extension angle values was used. The results were tabulated and analysed (R v2.9.1).

Results: Of the 99 knees, 38 were female and 61 male; 44 left knees and 55 right. The mean extension facet angle for the partial thickness group was 12.7° (SD 3.35) and for the comparator group 8.7° (SD 3.09). There was a significant difference between these 2 groups (Mann Whitney U, p< 0.001). Although there were significantly more men than women in the comparator group, stratification analysis showed that there was no effect of gender on the mean extension facet angle.

Discussion: There is a significance difference in the extension facet angle between patients with AMG with only partial thickness cartilage loss and a comparator group. This has not been shown in a study group of this size before. Since none of the subjects had full thickness cartilage loss it is unlikely that this difference is due to bone attrition changing the angle as part of the disease process but this is an important area for further study. We believe that a higher medial tibial extension facet angle alters the mechanics within the medial compartment, placing these patients at higher risk of developing AMG. This may present an opportunity for risk factor modification, for example osteotomy.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 19 - 19
1 Jan 2011
Pandit H Jenkins C Beard D Gill H Price A Dodd C Murray D
Full Access

The results of mobile bearing Oxford unicompartmental knee replacement (UKR) in the lateral compartment have been disappointing (five-year survival: 82%). Therefore, it is recommended that mobile bearings should not be used for lateral UKR. This low survivorship is primarily due to a high dislocation rate. A detailed analysis confirmed the elevated lateral tibial joint line to be a contributory factor to bearing dislocation. A new surgical technique was therefore introduced in which care was taken neither to remove too much bone from the distal femur nor to over tighten the knee and therefore ensure that the tibial joint line was not elevated. Other modifications included use of a domed tibial component.

The aim of this study is to compare the outcome of these iterations: the original series (series I), those with improved surgical technique (series II) and the domed tibial component (series III). The primary outcome measure was bearing dislocation at one year. One year was chosen as all the dislocations in the first series occurred within a year. In the original series (n=53), implanted using a standard open approach, there were six dislocations in the first year, the average flexion 110°, and 95% had no/mild pain on activity. In the second series (n=65), there were 3 dislocations, the average flexion was 117°, and 80% had no/mild pain on activity.

In the third series with the modified technique and a convex domed tibial plateau, there was one dislocation, average flexion was 125° and 94% had no/mild pain on activity. At four years the cumulative primary dislocation rates were 10%, 5% and 0% respectively, and were significantly different (p=0.04).

The improved surgical technique and implant design has reduced dislocation rate to an acceptable level so a mobile bearing can now be recommended for lateral UKR.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 26 - 26
1 Jan 2011
Gulati A Glyn-Jones S Simpson D Palan J Beard D Gill H McLardy-Smith P Gundle R Murray D
Full Access

Roentgen Stereophotogrammetric Analysis (RSA) can predict long-term outcome of prostheses by measuring migration over time. The Exeter femoral stem is a double-tapered highly polished implant and has been shown to subside within the cement mantle in 2 year RSA studies. It has a proven track record in terms of long-term survivorship and low revision rates. Several studies have demonstrated excellent clinical outcomes following its implantation but this is the first study to assess stem migration at 10 years, using RSA.

This is a single-centre study involving 20 patients (mean age: 63 years, SD=7) undergoing primary total hip replacement for degenerative osteoarthritis using the lateral (Hardinge) approach. RSA radiographs were taken with the patient bearing full weight post-operatively, at 3, 6, 12 months and at 2, 5 and 10 years follow-up. The three-dimensional migration of the Exeter femoral stem was determined.

The mean Oxford Hip Score at 10 years was 43.4 (SD=4.6) and there were no revisions. The stems subsided and rotated internally during a 10-year period. The mean migrations of the head and tip of the femoral stem in all three anatomic directions (antero-posterior, medio-lateral & supero-distal) were 0.69 mm posterior, 0.04 mm lateral and 1.67 mm distal for the head and 0.20 mm anterior, 0.02 mm lateral and 1.23 mm distal for the tip. The total migration at 10 years was 1.81 mm for the head and 1.25 mm for the tip.

The Exeter femoral stem exhibits migration which is a complex combination of translation and rotation in three dimensions. Comparing our 10 year with our previous 2 year migration results, the Exeter stems show continued, but slow distal migration and internal rotation. The subsidence continues to compress the cement and bone-cement interface which maintains secure fixation in the long term.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 19 - 19
1 Jan 2011
Pandit H Jenkins C Beard D Gill H Price A Dodd C Murray D
Full Access

About ten years ago we introduced sophisticated instrumentation and an increased range of component sizes for the Oxford unicompartmental knee replacement (UKR) to facilitate a minimally invasive surgical (MIS) approach. The device is now routinely implanted through an incision from the medial pole of the patella to the tibial tuberosity. This has resulted in a more rapid recovery and an improved functional result. As the access to the knee is limited there is a concern that the long term results may be compromised. The aim of this study was to determine the 10 year survival.

A prospective follow up of all Phase 3 minimally invasive Oxford UKR implanted by two senior authors (DWM & CAFD) has been undertaken. So far 1015 UKRs have been implanted for anteromedial osteoarthritis. All patients received a cemented implant through a MIS approach and were followed up prospectively by an independent observer. The data was collected prospectively regarding pre-operative status, complications and clinical as well as functional outcome at predetermined intervals.

The average age of patients was 66.4 years (range: 33 – 88) with mean Oxford Knee Score 41 (SD: 7.9) at the time of last follow up, Knee Society Score (objective) of 84 (SD: 13) and Knee Society Score (functional) of 83 (SD: 21). At ten years the survival of this cohort is 96%. There were 22 revisions including 7 for progression of arthritis, 5 for infection, 5 for bearing dislocation, 4 for unexplained pain and one for rupture of ACL secondary to trauma.

We conclude that the Oxford Knee can be implanted reliably through a minimally invasive approach, giving excellent long term results.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 73 - 73
1 Jan 2011
Bottomley N McNally E Ostlere S Kendrick B Murray D Dodd C Beard D Price A
Full Access

Introduction: This study explores whether modern magnetic resonance imaging (MRI) with improved cartilage sequencing is able to show a more detailed view of antero-medial osteoarthritis of the knee (AMOA) than previously, so enabling a radiographic description of this common phenotype of disease. Modern MRI technology allows us to visualize in great detail the structures and cartilage within the knee, providing a better understanding of the pathoanatomy of AMOA. This description of the end stage of disease is useful as a baseline when investigating the progression of arthritis through the knee. Preoperative assessment of patients and selection of intervention is very important and preoperative imaging forms an integral part of this. This will also be useful in preoperative assessment and surgical management of patients.

Methods: 50 patients with a radiographic diagnosis of anteromedial osteoarthritis of the knee and had been listed for unicompartmental knee arthroplasty (UKA) had MRI as part of their pre-op workup. At operation all were deemed suitable for UKA using the current Oxford indications. The image sequences were coronal, axial and sagittal with a predetermined cartilage protocol. The state of the ACL, cartilage wear degree and location, presence and pattern of osteophytes, meniscal anatomy and subchondral high signal were assessed.

Results: All the ACLs were visualized and in continuity, however 40% showed intrasubstance high signal. 100% of medial compartments showed full thickness anteromedial loss with preservation of the posteromedial cartilage. When present, the meniscus was extruded in 75% of cases.

90% of lateral compartments were normal and none had full thickness cartilage loss. However 10% showed high signal in the tibial plateau. There was a highly reproducible pattern of osteophyte formation; 94% posteromedial and posterolateral aspect of medial femoral condyle; 90% medial tibial; 80% medial femoral and 84% lateral intercondylar notch.

Discussion: This study maps the pattern of anteromedial osteoarthritis using modern MRI techniques. This creates a baseline description of disease which is useful when investigating disease progression. This also has importance in determining preoperative indications (preservation of ACL and posteromedial cartilage); surgical technique (determine pattern of osteophytes requiring resection) and potentially important for long-term outcome (early lateral compartment changes).


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 517 - 517
1 Oct 2010
Grammatopoulos G Beard D Gibbons C Gill H Gundle R Mclardy-Smith P Murray D Pandit H Whitwell D
Full Access

Metal on Metal Hip Resurfacing Arthroplasty (MoMHRA) has gained popularity due to its perceived advantages of bone conservation and relative ease of revision to a conventional THR if it fails. Known MoMHRA-associated complications include femoral neck fracture, avascular necrosis/collapse of the femoral head/neck, aseptic loosening and soft tissue responses such as ALVAL and pseudotumours. This study’s aim was to assess the functional outcome of failed MoMHRA revised to THR and compare it with a matched cohort of primary THRs.

Method: We have revised 53 MoMHRA cases to THR; the reasons for revision were femoral neck fracture (Fracture Group, n=21), soft tissue reaction (Pseudotumour Group, n=16) and other causes (Other Group, n=16: loosening, AVN and infection). Average followup was 2.9 years. These MoMHRA revisions were compared with 103 matched controls from a primary THR cohort; matched for age, gender and length of followup. We compared, using the MannWhitney U test, operative time (OT, measured in minutes), and Oxford Hip Score (OHS) between the revised MoMHRA groups and their individual controls. We also compared, using the Kruskal Wallis test, UCLA Activity Score in the revised MoMHRA groups.

Results: There were no differences between the Fracture Group (mean OT 99.6, SD: 30.4; mean OHS 19.8, SD:9.2) and its controls (mean OT 95.9, SD: 31.8; mean OHS 17.3, SD: 7.5) nor between the Other Group (mean OT 129.4, SD: 36.7; mean OHS 22.2, SD: 9.4) and its controls (mean OT 104.4, SD: 39.2; mean OHS 20.3, SD: 10.1) in terms of OT and OHS. The Pseudotumour Group had significantly longer OT (mean 161.6, SD: 24.5, p< 0.001) and worse outcome (mean OHS 39.1, SD: 9.3, p< 0.001) than its controls (mean OT 113.1, SD: 51.7; mean OHS 20.0, SD: 9.2). In the Fracture Group, there were 3 infections requiring revisions. For the Pseudotumour Group, there were 3 recurrent dislocations, 1 femoral artery stenosis and 3 femoral nerve palsies. In the Other Group, there were 2 periprosthetic fractures. There was significant difference (p< 0.001) in UCLA scores between the MoMHRA groups. The Pseudotumour Group had the lowest mean UCLA score of 3.8 (SD: 1.89). The Fracture Group (mean: 7.0, S.D. 2.0) and the Other Group (mean: 6.7, S.D. 2.1) had similar UCLA scores.

Discussion: The results demonstrate that outcome after revision of MoMHRA is dependent upon the indication for revision. Patients revised for soft tissue reactions had significantly worse outcome. Patients with soft tissue reactions are more likely to experience complications and require further surgical intervention. The pseudotumour associated revisions were associated with a significantly prolonged OT. The overall complication rate for the study groups was quite high, with 11 (21%) revised MoMHRA cases experiencing a complication. The Pseudotumour Group had a higher complication rate (37%).


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 541 - 541
1 Oct 2010
Pandit H Beard D Dodd C Goodfellow J Jenkins C Murray D Price A
Full Access

Introduction: Most unicompartmental knee replacements (UKRs) employ cement for fixation of the prosthetic components to the bone. The information in the literature about the relative merits of cemented and cementless UKR is contradictory, with some favouring cementless fixation while others favouring cemented fixation. There is concern about the radiolucency which frequently develops around the tibial component with cemented fixations. The exact cause of the occurrence of radiolucency is unknown but according to some, it may suggest suboptimal fixation.

Method: Following ethical approval, 62 patients with medial OA were randomised to receive either cemented (n=31) or cementless components (n=31). All patients underwent identical surgical procedure with either a cemented or cementless Oxford UKR. Patients were assessed clinically and radiologically. The x-rays were taken with an image intensifier (I.I.). The position of the I.I. was adjusted until it was perfectly aligned with the tibial bone-implant interface thereby allowing accurate assessment of presence and extent of the radiolucency.

Results: The patients in the two groups were well matched. There was no significant difference in the clinical scores between the two groups. The mean OKS for the cemented group was 40 (± 8.3) and 42 (± 4.6) for cementless group. Narrow radiolucent lines were seen at the bone-implant interfaces of 75% of the cemented tibial components; partial in 43% and complete in 32%. In the cementless implants, partial radiolucencies were seen in 7% and complete radiolucencies in none. The differences are statistically highly significant (p< 0.0001) and imply satisfactory bone ingrowth into the cementless implants.

Conclusions: The method of fixation influences the incidence of radiolucency. With identical designs, no patient with cementless components developed any complete radiolucency. The observation raises the question as to whether cementless rather than cemented components should be routinely used for UKR.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 505 - 505
1 Oct 2010
Monk A Beard D Dodd C Doll H Gibbons C Gill H Murray D Ostlere S Simpson D
Full Access

Patello-femoral instability (PFI) affects 40 individuals per 100,000 population and causes significant morbidity. The causes of patello-femoral instability are multi-factorial, and an isolated anatomical abnormality does not necessarily indicate instability. Patello-femoral subluxation ranges from 0% (stable patella tracking) to 100% (dislocation) and there is an established relationship between the amount of subluxation and anterior knee pain. Traditionally, magnetic resonance (MR) imaging and standard radiographs are used to guide the clinician towards a suitable corrective procedure for PFI. The multi-factorial nature of patello-femoral instability is not addressed with current imaging techniques. This study aims to address which anatomical variables assessed on MR images are most relevant to patello-femoral subluxation. This information will aid surgical decision making, particularly in selecting the most appropriate reconstructive surgery.

A retrospective analysis of MR studies of 60 patients with suspected patello-femoral instability was performed. All patients were graded for degree of subluxation using a dynamic MR scan.

The patient scans were assessed for the presence of a specific range of anatomical variables:

patella alta, (modified Insall-Salvatti)

patella type (Wiberg classification)

trochlea sulcus angles for bone and cartilage surfaces

the distance of the vastus medialis obliquis (VMO) muscle from the patella

trochlea and patella cartilage thickness

the horizontal distance between the tibial tubercle and the midpoint of the femoral trochlea (TTD)

patella engagement – the percentage of the patella height that is captured in the trochlea groove in full extension.

The Wilk’s Lambda test for multi-variate analysis was used to establish whether any relationship was present between the degree of patello-femoral instability and bony or soft tissue anatomical variables. Non-parametric statistical tests were applied across the groups and within the groups to assess their relative significance.

The following variables showed a significant relationship with patellofemoral subluxation; distance of the VMO from the patella (< 0.001), TTD (< 0.001), patella engagement (0.001), sulcus angles (0.004) and patella alta (0.005).

This study agrees with previous work showing a significant correlation between subluxation and trochlea sulcus angle and TTD.

This is the first study to establish a significant correlation between patella engagement and radiological instability. The lower the percentage engagement of the patella in the trochlea, the greater the degree of patello-femoral instability. Patella engagement showed a more significant relationship with subluxation than patella alta.

We report a new method of predicting patello-femoral instability by measuring the overlap of the patella in the trochlea groove.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 412 - 413
1 Jul 2010
Price A Longino D Svard U Kim K Weber P Fiddian N Shakespeare D Keys G Beard D Pandit H Dodd C Murray D
Full Access

Purpose: The purpose of this study was to report the mid-term survival results of Oxford UKAs in patients of 50 years of age or less, using (1) revision surgery and (2) Oxford Knee Scores (OKS) as outcome measures.

Method: A literature review identified studies of Oxford mobile bearing UKAs containing individuals 1) 50 years old or less with 2) medial osteoarthritis and 3) 2 years or longer follow-up. Authors were approached to participate in a multi-centre survival analysis by submitting all their patients, 50 years of age or less, who received a medial UKA for osteoarthritis. Patients who had died, been lost to follow-up or who underwent revision were identified. OKS were established for all patients with surviving implants.

Results: Seven centres submitted 107 patients. The mean age was 47 years (range 32–50). The average follow-up was 4 years (range 1–25). Forty-seven patients had follow-up into their fifth year or longer. The cumulative 7-year survival using revision as the endpoint was 96% (CI 8). The mean post-operative OKS for surviving implants was 38 (CI 2) out of a possible 48.

Conclusion: While early survival rates and function are encouraging, long-term follow-up is required before concluding UKA is a viable treatment option in young patients with unicompartmental knee arthritis.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 391 - 392
1 Jul 2010
Hossain M Parfitt D Beard D Murray D Nolan J Andrew J
Full Access

Introduction: We investigated the relationship between psychological distress and outcome after total hip replacement (THR) in the Exeter Primary Outcome Study (EPOS).

Materials & Methods: Data were collected from a number of centres across England between January 1999 and January 2002 for patients undergoing primary hip replacement using the cemented Exeter femoral component (Stryker). We recorded the Oxford Hip Score (OHS) for physical function and SF36 questionnaire for both physical and mental domain assessment annually for five years. We dichotomised the patients into the mentally distressed (MHS < 50) and the not mentally distressed (MHS ≥ 50) groups based on their pre-operative Mental Health Score (MHS) from the SF36 score.

Results: Complete data were available for 455 (407 not distressed and 48 distressed) patients. Pre-operative OHS and SF-36 score was significantly worse in the distressed group (both p< 0.001). Mean OHS improved from 43 to 20 at 1 year after surgery and remained the same thereafter in the non distressed group. In the mentally distressed group pre-operative mean OHS of 48 improved to 22 at 1 year after surgery. Maximum improvement in OHS occurred in the 1st yr after surgery. Mean MHS improved from 76 to 81 at 1 year after surgery and remained the same thereafter in the non distressed group. Mean MHS improved from 35 to 62 at 1 year after surgery, reaching 65 at 5 years after surgery in the mentally distressed group. The maximum improvement in MHS occurred in the 1st yr after surgery.

Conclusion: Pre-operative psychological distress did not compromise functional outcome after hip arthroplasty. There was a substantial improvement in mental distress in patients with mental distress prior to surgery. Both groups of patients experienced improvement in Oxford Hip Score, which was maximal by 1 year after surgery and was maintained over the 5 year follow up.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 411 - 411
1 Jul 2010
Kendrick BJL Simpson D Bottomley NJ Marks B Pandit H Beard D Gill HS Dodd CA Murray DW Price AJ
Full Access

Purpose: This study was designed to establish the poly-ethylene wear rates in the Oxford medial unicompert-mental knee replacement.

Introduction: The Oxford meniscal bearing knee was introduced as a design to reduce polyethylene wear. There has been one previous retrieval study of the Oxford UKA, which reported very low wear rates in some specimens, but abnormal patterns of wear in others, including impingement. There has been no further investigation of these abnormal wear patterns.

Methods: Forty-seven bearings were retrieved from patients who had received a medial Oxford UKA for anteromedial osteoarthritis of the knee, none of which had previously been studied. Mean time to revision was 8.4 years (SD 4.1) and 20 had been implanted for over 10 years. The macroscopic pattern of polyethylene wear and the linear penetration (dial gauge measurement) was recorded for each bearing.

Results: The mean linear penetration rate (LPR) was 0.07mm/year. The patterns of wear fell into 4 categories, each with a different LPR; 1) No abnormal macroscopic appearance, n=16 (LPR = 0.01mm/year), 2) Abnormal macroscopic wear with extra-articular impingement, n=16 (LPR = 0.05mm/year), 3) Abnormal macroscopic wear with intra-articular impingement, n=6 (LPR = 0.10mm/year), 4) Abnormal macroscopic wear with impingement and signs of incongruous articulation, n=9 (LPR = 0.14mm/year). The differences in LPR were statistically significant (p< 0.05).

Conclusion: The results show that very low polyethylene wear rates are possible if the device functions normally. However if the bearing displays abnormal function (extra-articular, intra-articular impingement or incongruous articulation) wear rates increase significantly.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 390 - 390
1 Jul 2010
Grammatopoulos G Pandit H Kwon Y Singh P Gundle R McLardy-Smith P Beard D Gill H Murray D
Full Access

Introduction: Metal on metal Hip Resurfacing Arthroplasty (MoMHRA) has gained popularity due to its perceived advantages of bone conservation and relative ease of revision to a conventional THR if it fails. This retrospective study is aimed at assessing the functional outcome of failed MoMHRA revised to THR and comparing it with a matched cohort of primary THRs.

Method: Since 1999 we have revised 53 MoMHRA to THR. The reasons for revision were femoral neck fracture (Group A, n=21), pseudotumour (Group B, n=16) and other causes (Group C, n=16: loosening, avascular necrosis and infection). Average follow-up was 3 years months (1.2–7.3). These revisions were compared with 106 primary THRs which were age, gender and follow-up matched with the revision group in a ratio of 2:1.

Results: The mean Oxford Hip Score (OHS) was 20.1 (12–51) for group A, 39.1 (14– 56) for group B, 22.8 (12–39) for group C and 17.8 (12–45) for primary THR group. In group A, there were three infections requiring further revisions. In group B, there were three recurrent dislocations, three patients with femoral nerve palsy and one femoral artery stenosis. In group C, there were no complications. The differences in clinical and functional outcome between group B and the remaining groups as well as the difference in the outcome between group B and control group were statistically significant (p < 0.05).

Conclusions: THR for failed MoMHRA was associated with significantly more complications, operation time and need for blood transfusion for the pseudotumour group. In addition, the revisions secondary to pseudotumour also had significantly worse functional outcome when compared to other MoMHRA revisions or primary THR.