header advert
Results 1 - 100 of 111
Results per page:
Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 36 - 36
2 May 2024
Jones R Phillips J Panteli M
Full Access

Total joint arthroplasty (TJA) is one of the commonest and most successful orthopaedic procedures used for the management of end-stage arthritis. With the recent introduction of robotic-assisted joint replacement, Computed tomography (CT) has become part of required pre-operative planning.

The aim of this study is to quantify and characterise incidental CT findings, their clinical significance, and their effect on the planned joint arthroplasty.

All consecutive patients undergoing an elective TJA (total joint arthroplasty; hip or knee) were retrospectively identified, over a 4-year period (December 2019 and November 2023). Data documented and analysed included patient demographics, type of joint arthroplasty, CT findings, their clinical significance, as well as potential delays to the planned arthroplasty because of these findings and subsequent further investigation.

A total of 987 patients (female: 514 patients (52.1%)) undergoing TJA were identified (THA: 444 patients (45.0%); TKA: 400 patients (40.5%); UKA: 143 patients (14.5%)). Incidental findings within imaged areas were identified in 227 patients (23.0%). Of these findings, 74 (7.5%) were significant, requiring further investigation or management, 40 (4.1%) of which represented potential malignancy and 4 (0.4%) resulting in a new cancer diagnosis. A single patient was found to have an aneurysm requiring urgent vascular intervention. Surgery was delayed for further investigation in 4 patients (0.4%). Significant findings were more frequent in THA patients (THA: 43 (9.7%) TKA/UKA: 31 (5.7%)

Within our cohort, 74 (7.5%) patients had significant incidental findings that required further investigations or management, with 4 (0.4%) having a previously undiagnosed malignancy. We strongly advocate that all robotic arthroplasty planning CTs are reviewed and reported by a specialist, to avoid missing undiagnosed malignancies and other significant diagnoses.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 34 - 34
17 Nov 2023
Elliott M Rodrigues R Hamilton R Postans N Metcalfe A Jones R McGregor A Arvanitis T Holt C
Full Access

Abstract

Objectives

Biomechanics is an essential form of measurement in the understanding of the development and progression of osteoarthritis (OA). However, the number of participants in biomechanical studies are often small and there is limited ways to share or combine data from across institutions or studies. This is essential for applying modern machine learning methods, where large, complex datasets can be used to identify patterns in the data. Using these data-driven approaches, it could be possible to better predict the optimal interventions for patients at an early stage, potentially avoiding pain and inappropriate surgery or rehabilitation. In this project we developed a prototype database platform for combining and sharing biomechanics datasets. The database includes methods for importing and standardising data and associated variables, to create a seamless, searchable combined dataset of both healthy and knee OA biomechanics.

Methods

Data was curated through calls to members of the OATech Network+ (https://www.oatechnetwork.org/). The requirements were 3D motion capture data from previous studies that related to analysing the biomechanics of knee OA, including participants with OA at any stage of progression plus healthy controls. As a minimum we required kinematic data of the lower limbs, plus associated kinetic data (i.e. ground reaction forces). Any additional, complementary data such as EMG could also be provided. Relevant ethical approvals had to be in place that allowed re-use of the data for other research purposes. The datasets were uploaded to a University hosted cloud platform. The database platform was developed using Javascript and hosted on a Windows server, located and managed within the department.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 52 - 52
17 Nov 2023
Jones R Bowd J Gilbert S Wilson C Whatling G Jonkers I Holt C Mason D
Full Access

Abstract

OBJECTIVE

Knee varus malalignment increases medial knee compartment loading and is associated with knee osteoarthritis (OA) progression and severity1. Altered biomechanical loading and dysregulation of joint tissue biology drive OA progression, but mechanistic links between these factors are lacking. Subchondral bone structural changes are biomechanically driven, involve bone resorption, immune cell influx, angiogenesis, and sensory nerve invasion, and contribute to joint destruction and pain2. We have investigated mechanisms underlying this involving RANKL and alkaline phosphatase (ALP), which reflect bone resorption and mineralisation respectively3 and the axonal guidance factor Sema3A. Sema3A is osteotropic, expressed by mechanically sensitive osteocytes, and an inhibitor of sensory nerve, blood vessel and immune cell invasion4. Sema3A is also differentially expressed in human OA bone5.HYPOTHESIS: Medial knee compartment overloading in varus knee malalignment patients causes dysregulation of bone derived Sema3A signalling directly linking joint biomechanics to pathology and pain.

METHODS

Synovial fluid obtained from 30 subjects with medial knee OA (KL grade II-IV) undergoing high tibial osteotomy surgery (HTO) was analysed by mesoscale discovery and ELISA analysis for inflammatory, neural and bone turnover markers. 11 of these patients had been previously analysed in a published patient-specific musculoskeletal model6 of gait estimating joint contact location, pressure, forces, and medial-lateral condyle load distribution in a published data set included in analyses. Data analysis was performed using Pearson's correlation matrices and principal component analyses. Principal Components (PCs) with eigenvalues greater than 1 were analysed.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 49 - 49
17 Nov 2023
Jones R Gilbert S Mason D
Full Access

Abstract

OBJECTIVE

Changes in subchondral bone are one of few disease characteristics to correlate with pain in OA1. Profound neuroplasticity and nociceptor sprouting is displayed within osteoarthritic (OA) subchondral bone and is associated with pain and pathology2. The cause of these neural changes remains unestablished. Correct innervation patterns are indispensable for bone growth, homeostasis, and repair. Axon guidance signalling factor, Sema3A is essential for the correct innervation patterning of bony tissues3, expressed in osteocytes4 and known to be downregulated in bone OA mechanical loading5. Bioinformatic analysis has also shown Sema3a as a differentially expressed pathway by bone in human OA patients6.HYPOTHESIS: Pathological mechanical load and inflammation of bone causes dysregulation of Sema3A signalling leading to perturbed sensory nerve plasticity and pain.

METHODS

Human KOLF2-C1 iPSC derived nociceptors were generated by TALEN-mediated insertion of transcription factors NGN2+Brn3A and modified chambers differentiation protocol to produce nociceptor-like cells. Nociceptor phenotype was confirmed by immunocytochemistry. Human Y201-MSC cells were embedded in 3D type-I collagen gels (0.05 × 106 cell/gel), in 48-well plates and silicone plates, were differentiated to osteocytes for 7 days before stimulation with IL-6 (5ng/ml) and soluble IL-6 receptor (sIL-6r (40ng/ml), IL6/sIL6r and mechanical load mimetic Yoda1 (5μM) or unstimulated (n=5/group) (48-well plates) or were mechanically loaded in silicone plates (5000μstrain, 10Hz, 3000 cycles) or not loaded (n=5/group). Conditioned media transfer was performed from osteocyte to nociceptor cultures assessed by continuous 24-hour phase contrast confocal microscopy. 24-hours after stimulation RNA was quantified by RT-qPCR (IL6) or RNAseq whole transcriptome analysis/DEseq2 analysis (Load). Protein release was quantified by ELISA. Normally distributed data with homogenous variances was analysed by two-tailed t test.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 82 - 82
7 Aug 2023
Jones R Phillips J Panteli M
Full Access

Abstract

Introduction

Total joint arthroplasty (TJA) is one of the commonest and most successful orthopaedic procedures, used for the management of end-stage arthritis. With the recent introduction of robotic assisted joint replacement, Computed Tomography (CT) has become part of required pre-operative planning.

The aim of this study is to quantify and characterise incidental CT findings, their clinical significance, and their effect on planned joint arthroplasty.

Methodology

All consecutive patients undergoing an elective TJR (hip or knee arthroplasty) were retrospectively identified, over a 3-year period (December 2019 and December 2022). Data documented and analysed included patient demographics, type of joint arthroplasty, CT findings, their clinical significance, as well as potential delays to the planned arthroplasty because of these findings and subsequent further investigation.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 74 - 74
11 Apr 2023
Gilbert S Jones R White P Mason D
Full Access

Stimulation of the mechanosensitive ion channel, Piezo1 promotes bone anabolism and SNPs in the Piezo1 locus are associated with changes in fracture risk. Osteocytes function as critical regulators of bone homeostasis by sensing mechanical signals. The current study used a human, cell-based physiological, 3D in vitro model of bone to determine whether loading of osteocytes in vitro results in upregulation of the Piezo1 pathway.

Human Y201 MSCs, embedded in type I collagen gels and differentiated to osteocytes for 7-days, were subjected to pathophysiological load (5000 µstrain, 10Hz, 5 mins; n=6) with unloaded cells as controls (n=4). RNA was extracted 1-hr post load and assessed by RNAseq analysis. To mimic mechanical load and activate Piezo1, cells were differentiated to osteocytes for 13 days and treated ± Yoda1 (5µM, 2- and 24-hs, n=4); vehicle treated cells served as controls (n=4). RNA was subjected to RT-qPCR and data normalised to the housekeeping gene, YWHAZ. Media was analysed for IL6 release by ELISA.

Mechanical load upregulated Piezo1 gene expression (16.5-fold, p<0.001) and expression of the transcription factor NFATc1, and matricellular protein CYR61, known regulators of Piezo1 mechanotransduction (3-fold; p= 5.0E-5 and 6.8-fold; p= 6.0E-5, respectively). After 2-hrs, Yoda1 increased the expression of the early mechanical response gene, cFOS (11-fold; p=0.021), mean Piezo1 expression (2.3-fold) and IL-6 expression (103-fold, p<0.001). Yoda1 increased the release of IL6 protein after 24 hours (7.5-fold, p=0.001).

This study confirms Piezo1 as an important mechanosensor in osteocytes. Piezo1 activation mediated an increase in IL6, a cytokine that drives inflammation and bone resorption providing a direct link between mechanical activation of Piezo1, bone remodeling and inflammation, which may contribute to mechanically induced joint degeneration in diseases such as osteoarthritis. Mechanistically, we hypothesize this may occur through promoting Ca2+ influx and activation of the NFATc1 signaling pathway.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 39 - 39
11 Apr 2023
Jones R Gilbert S Mason D
Full Access

Osteoarthritis (OA) is a common cause of chronic pain. Subchondral bone is highly innervated, and bone structural changes directly correlate with pain in OA. Mechanisms underlying skeletal–neural interactions are under-investigated. Bone derived axon guidance molecules are known to regulate bone remodelling. Such signals in the nervous system regulate neural plasticity, branching and neural inflammation. Perturbation of these signals during OA disease progression may disrupt sensory afferents activity, affecting tissue integrity, nociception, and proprioception.

Osteocyte mechanical loading and IL-6 stimulation alters axon guidance signalling influencing innervation, proprioception, and nociception.

Human Y201 MSC cells, embedded in 3D type I collagen gels (0.05 × 106 cell/gel) in 48 well plastic or silicone (load) plates, were differentiated to osteocytes for 7 days before stimulation with IL-6 (5ng/ml) with soluble IL-6 receptor (sIL-6r (40ng/ml) or unstimulated (n=5/group), or mechanically loaded (5000 μstrain, 10Hz, 3000 cycles) or not loaded (n=5/group). RNA extracted 1hr and 24hrs post load was quantified by RNAseq whole transcriptome analysis (NovaSeq S1 flow cell 2 × 100bp PE reads and differentially expressed neurotransmitters identified (>2-fold change in DEseq2 analysis on normalised count data with FDR p<0.05). After 24 hours, extracted IL-6 stimulated RNA was quantified by RT-qPCR for neurotrophic factors using 2–∆∆Ct method (efficiency=94-106%) normalised to reference gene GAPDH (stability = 1.12 REfinder). Normally distributed data with homogenous variances was analysed by two-tailed t test.

All detected axonal guidance genes were regulated by mechanical load. Axonal guidance genes were both down-regulated (Netrin1 0.16-fold, p=0.001; Sema3A 0.4-fold, p<0.001; SEMA3C (0.4-fold, p<0.001), and up-regulated (SLIT2 2.3-fold, p<0.001; CXCL12 5-fold, p<0.001; SEMA3B 13-fold, p<0.001; SEMA4F 2-fold, p<0.001) by mechanical load. IL6 and IL6sR stimulation upregulated SEMA3A (7-fold, p=0.01), its receptor Plexin1 (3-fold, p=0.03). Neutrophins analysed in IL6 stimulated RNA did not show regulation.

Here we show osteocytes regulate multiple factors which may influence innervation, nociception, and proprioception upon inflammatory or mechanical insult. Future studies will establish how these factors may combine and affect nerve activity during OA disease progression.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 20 - 20
11 Apr 2023
Hamilton R Holt C Hamilton D Garcia A Graham C Jones R Shilabeer D Kuiper J Sparkes V Khot S Mason D
Full Access

Mechanical loading of joints with osteoarthritis (OA) results in pain-related functional impairment, altered joint mechanics and physiological nociceptor interactions leading to an experience of pain. However, the current tools to measure this are largely patient reported subjective impressions of a nociceptive impact. A direct measure of nociception may offer a more objective indicator. Specifically, movement-induced physiological responses to nociception may offer a useful way to monitor knee OA. In this study, we gathered preliminary data on healthy volunteers to analyse whether integrated biomechanical and physiological sensor datasets could display linked and quantifiable information to a nociceptive stimulus.

Following ethical approval, 15 healthy volunteers completed 5 movement and stationary activities in 2 conditions; a control setting and then repeated with an applied quantified thermal pain stimulus to their right knee. An inertial measurement unit (IMU) and an electromyography (EMG) lower body marker set were tested and integrated with ground reaction force (GRF) data collection. Galvanic skin response electrodes for skin temperature and conductivity and photoplethysmography (PPG) sensors were manually timestamped to the integrated system.

Pilot data showed EMG, GRF and IMU fluctuations within 0.5 seconds of each other in response to a thermal trigger. Preliminary analysis on the 15 participants tested has shown skin conductance, PPG, EMG, GRFs, joint angles and kinematics with varying increases and fluctuations during the thermal condition in comparison to the control condition.

Preliminary results suggest physiological and biomechanical data outputs can be linked and identified in response to a defined nociceptive stimulus. Study data is currently founded on healthy volunteers as a proof-of-concept. Further exploratory statistical and sensor readout pattern analysis, alongside early and late-stage OA patient data collection, can provide the information for potential development of wearable nociceptive sensors to measure disease progression and treatment effectiveness.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_9 | Pages 1 - 1
1 Oct 2022
Paskins Z Le Maitre C Farmer C Clark E Mason D Wilkinson C Andersson D Bishop F Brown C Clark A Jones R Loughlin J McCarron M Pandit H Richardson S Salt E Taylor E Troeberg L Wilcox R Barlow T Peat G Watt F
Full Access

Background

Involving research users in setting priorities for research is essential to ensure research outcomes are patient-centred and to maximise research value and impact. The Musculoskeletal (MSK) Disorders Research Advisory Group Versus Arthritis led a research priority setting exercise across MSK disorders.

Methods

The Child Health and Nutrition Research Initiative (CHRNI) method of setting research priorities with a range of stakeholders were utilised. The MSKD RAG identified, through consensus, four research Domains: Mechanisms of Disease; Diagnosis and Impact; Living Well with MSK disorders and Successful Translation. Following ethical approval, the research priority exercise involved four stages and two surveys, to: 1) gather research uncertainties; 2) consolidate these; 3) score uncertainties using agreed criteria of importance and impact on a score of 1–10; and 4) analyse scoring, for prioritisation.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 72 - 72
1 Jul 2022
Jones R Opon D Sheen J Hockings M Isaac D
Full Access

Abstract

INTRODUCTION

Geniculate nerve blocks (GNB) and ablation (GNA) are increasing in popularity as strategies for the management of knee pain in patients unsuitable for surgical intervention. Typically these simple blocks have been performed by specialists in pain medicine. We present the results of a GNB clinic run by a surgical care practitioner (SCP).

METHODOLOGY

An SCP clinic was created where ultrasound-guided GNBs comprising local anaesthetic and steroid were administered. Patients considered unsuitable for surgery were referred with knee pain by orthopaedic knee surgeons and specialist physiotherapists.

A VAS pain score and an Oxford Knee Score (OKS) were completed prior to and immediately following blockade. Serial VAS diaries were completed. Further OKS were requested at 6 weeks and 6 months. Patients could request GNA at any point during follow-up and their follow-up ceased at this stage.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_2 | Pages 5 - 5
1 Mar 2022
Clutton JM Razii N Chitnis SS Kakar R Morgan-Jones R
Full Access

Introduction

The burden of prosthetic joint infection (PJI) in total knee arthroplasty (TKA) has been rising in line with the number of primary operations performed. Current estimates suggest an infection rate of 1–2.4%. Two-stage revision has traditionally been considered the gold standard of treatment; however, some studies suggest comparable results can be achieved with single-stage procedures. The potential advantages include less time in hospital, a single anaesthetic, reduced costs, and greater patient satisfaction.

Methods

We reviewed data for 72 patients (47 males, 25 females), with a mean age of 71 years (range, 49 to 94), who underwent single-stage revision TKA for confirmed PJI between 2006 and 2016. A standardized debridement protocol was performed with immediate single-stage exchange. All cases were discussed preoperatively at multidisciplinary team (MDT) meetings, which included input from a senior musculoskeletal microbiologist. Patients were not excluded for previous revisions, culture-negative PJI, or the presence of a sinus.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 73 - 73
1 Dec 2021
Jones R Gilbert S Mason D
Full Access

Abstract

INTRODUCTION

Knee tactile afferents act as synovial joint limit detectors, eliciting signalling upon excessive fibrous tissue strain but play little role in joint function as disruption of their activity does not induce impairments in movement or sensation. In contrast, knee nociceptive afferents gain activity upon inflammation producing painful sensation in pathology such as osteoarthritis. We hypothesize that similar in origin, fast-conducting tactile afferents become sensitized by inflammatory mediators and gain activity causing proprioceptive sensation impairment in patients with knee pathology, driving gait abnormalities and osteoarthritis progression. To investigate the activity of these neurons, we will produce a co-culture model using our existing 3D bone mimetic and iPSC derived tactile sensory neurons by utilizing the NGN2-BRN3A plasmid produced by Nickolls et al producing a model of these tactile neurons at their position within the joint at the fibrous/bony interface.

METHODS

Human Y201 MSC cells embedded in type I collagen gels (0.05 × 106 cell/gel) were differentiated to osteocytes andmechanically loaded in silicone plates (5000 µstrain, 10Hz, 3000 cycles) (n=5). RNA quantified by RNAseq analysis (NovaSeq S1) and neuronal communication pathways identified using DEseq2 analysis.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_16 | Pages 64 - 64
1 Dec 2021
Hamilton R Holt C Hamilton D Jones R Shillabeer D Kuiper JH Sparkes V Mason D
Full Access

Abstract

Objectives

Current tools to measure pain are broadly subjective impressions of the impact of the nociceptive impulse felt by the patient. A direct measure of nociception may offer a more objective indicator. Specifically, movement-induced physiological responses to nociception may offer a useful way to monitor knee OA. In this proof-of-concept study, we evaluated whether integrated biomechanical and physiological sensor datasets could display linked and quantifiable information to a nociceptive stimulus.

Method

Following ethical approval, we applied a quantified thermal pain stimulus to a volunteer during stationary standing in a gait lab setting. An inertial measurement unit (IMU) and an electromyography (EMG) lower body marker set were tested and integrated with ground reaction force (GRF) data collection. Galvanic skin response electrodes and skin thermal sensors were manually timestamp linked to the integrated system.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 9 - 9
1 Jun 2021
Greene A Verstraete M Roche C Conditt M Youderian A Parsons M Jones R Flurin P Wright T Zuckerman J
Full Access

INTRODUCTION

Determining proper joint tension in reverse total shoulder arthroplasty (rTSA) can be a challenging task for shoulder surgeons. Often, this is a subjective metric learned by feel during fellowship training with no real quantitative measures of what proper tension encompasses. Tension too high can potentially lead to scapular stress fractures and limitation of range of motion (ROM), whereas tension too low may lead to instability. New technologies that detect joint load intraoperatively create the opportunity to observe rTSA joint reaction forces in a clinical setting for the first time. The purpose of this study was to observe the differences in rTSA loads in cases that utilized two different humeral liner sizes.

METHODS

Ten different surgeons performed a total of 37 rTSA cases with the same implant system. During the procedure, each surgeon reconstructed the rTSA implants to his or her own preferred tension. A wireless load sensing humeral liner trial (VERASENSE for Equinoxe, OrthoSensor, Dania Beach, FL) was used in lieu of a traditional plastic humeral liner trial to provide real-time load data to the operating surgeon during the procedure. Two humeral liner trial sizes were offered in 38mm and 42mm curvatures and were selected each case based on surgeon preference. To ensure consistent measurements between surgeons, a standardized ROM assessment consisting of four dynamic maneuvers (maximum internal to external rotation at 0°, 45°, and 90° of abduction, and a maximum flexion/extension maneuver) and three static maneuvers (arm overhead, across the body, and behind the back) was completed in each case. Deidentified load data in lbf was collected and sorted based on which size liner was selected. Differences in means for minimum and maximum load values for the four dynamic maneuvers and differences in means for the three static maneuvers were calculated using 2-tailed unpaired t-tests.


Bone & Joint Open
Vol. 2, Issue 5 | Pages 305 - 313
3 May 2021
Razii N Clutton JM Kakar R Morgan-Jones R

Aims

Periprosthetic joint infection (PJI) is a devastating complication following total knee arthroplasty (TKA). Two-stage revision has traditionally been considered the gold standard of treatment for established infection, but increasing evidence is emerging in support of one-stage exchange for selected patients. The objective of this study was to determine the outcomes of single-stage revision TKA for PJI, with mid-term follow-up.

Methods

A total of 84 patients, with a mean age of 68 years (36 to 92), underwent single-stage revision TKA for confirmed PJI at a single institution between 2006 and 2016. In all, 37 patients (44%) were treated for an infected primary TKA, while the majority presented with infected revisions: 31 had undergone one previous revision (36.9%) and 16 had multiple prior revisions (19.1%). Contraindications to single-stage exchange included systemic sepsis, extensive bone or soft-tissue loss, extensor mechanism failure, or if primary wound closure was unlikely to be achievable. Patients were not excluded for culture-negative PJI or the presence of a sinus.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 7 - 7
1 Mar 2021
Gilbert S Bonnet C Jones R Mason D
Full Access

Abstract

Objectives

The mechanisms underlying abnormal joint mechanics are poorly understood despite it being a major risk factor for developing osteoarthritis. This study investigated the response of a 3D in vitro bone cell model to mechanical load.

Methods

Human MSC cells (Y201) embedded in 3D type I collagen gels were differentiated in osteogenic media for 7-days in deformable, silicone plates. Gels were loaded once (5000 µstrain, 10Hz, 3000 cycles), RNA extracted 1-hr post load and assessed by RT-qPCR and RNAseq analysis (n=5/treatment). Cell shape and phenotype were assessed by immunocytochemistry and phalloidin staining. Data was analysed by Minitab.


Bone & Joint Research
Vol. 9, Issue 6 | Pages 311 - 313
1 Jun 2020
Tsang SJ Morgan-Jones R Simpson AHRW


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 136 - 136
1 Feb 2020
Greene A Parsons I Jones R Youderian A Byram I Papandrea R Cheung E Wright T Zuckerman J Flurin P
Full Access

INTRODUCTION

3D preoperative planning software for anatomic and reverse total shoulder arthroplasty (ATSA and RTSA) provides additional insight for surgeons regarding implant selection and placement. Interestingly, the advent of such software has brought previously unconsidered questions to light on the optimal way to plan a case. In this study, a survey of shoulder specialists from the American Shoulder and Elbow Society (ASES) was conducted to examine thought patterns in current glenoid implant selection and placement.

METHODS

172 ASES members completed an 18-question survey on their thought process for how they select and place a glenoid implant for both ATSA and RTSA procedures. Data was collected using a custom online Survey Monkey survey. Surgeon answers were split into three cohorts based on their responses to usage of 3D preoperative planning software: high users, seldom users, and non-users. Data was analyzed for each cohort to examine differences in thought patterns, implant selection, and implant placement.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 131 - 131
1 Feb 2020
Greene A Parsons I Jones R Youderian A Byram I Papandrea R Cheung E Wright T Zuckerman J Flurin P
Full Access

INTRODUCTION

The advent of CT based 3D preoperative planning software for reverse total shoulder arthroplasty (RTSA) provides surgeons with more data than ever before to prepare for a case. Interestingly, as the usage of such software has increased, further questions have appeared over the optimal way to plan and place a glenoid implant for RTSA. In this study, a survey of shoulder specialists from the American Shoulder and Elbow Society (ASES) was conducted to examine thought patterns in current RTSA implant selection and placement.

METHODS

172 ASES members completed an 18-question survey on their thought process for how they select and place a RTSA glenoid implant. Data was collected using a custom online Survey Monkey survey. Surgeon answers were split into two cohorts based on number of arthroplasties performed per year: between 0–75 was considered low volume (LV), and between 75–200+ was considered high volume (HV). Data was analyzed for each cohort to examine differences in thought patterns, implant selection, and implant placement.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 134 - 134
1 Feb 2020
Greene A Parsons I Jones R Youderian A Byram I Papandrea R Cheung E Wright T Zuckerman J Flurin P
Full Access

INTRODUCTION

3D preoperative planning software for anatomic total shoulder arthroplasty (ATSA) provides surgeons with increased ability to visualize complex joint relationships and deformities. Interestingly, the advent of such software has seemed to create less of a consensus on the optimal way to plan an ATSA rather than more. In this study, a survey of shoulder specialists from the American Shoulder and Elbow Society (ASES) was conducted to examine thought patterns in current ATSA implant selection and placement.

METHODS

172 ASES members completed an 18-question survey on their thought process for how they select and place an ATSA glenoid implant. Data was collected using a custom online Survey Monkey survey. Surgeon answers were split into two cohorts based on number of arthroplasties performed per year: between 0–75 was considered low volume (LV), and between 75–200+ was considered high volume (HV). Data was analyzed for each cohort to examine differences in thought patterns, implant selection, and implant placement.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 76 - 76
1 May 2019
Jones R
Full Access

In a recent study, 54.5% of patients reporting to arthroplasty clinics in the US were obese. We performed a recent literature review to determine how obesity impacts outcomes in total hip and knee arthroplasty and what must be done to improve outcomes in the obese arthroplasty patient.

Specifically, obese patients have shown increased rates of infection, dislocation, need for revision, wound dehiscence, increased operative time and prolonged hospital stay. Additionally, obese TKA patients have been shown to have increased rates of aseptic loosening, thromboembolic events, wound complications, and cardiopulmonary events.

Worsening severity of obesity seems to correlate with worsening outcomes and super obesity (BMI>50) has been identified as an independent risk factor for complications. Patients with BMI>35 have shown to be 6.7 times more likely to develop infection after TKA. Patients with BMI>40 have a 3.35 times higher rate of revision for deep infection than those with BMI<35. The odds ratio for major complications increases dramatically beyond BMI>45.

How can we improve outcomes in the obese patient? Preoperative care for the obese patient involves nutritional counseling, incorporating weight loss methods, physical therapy, metabolic workup and diagnosis and management of frequent comorbid conditions (OSA, DM2, HTN, HLD, malnutrition, renal failure). Identifying and managing comorbidities is especially important given that some comorbidities such as malnutrition have been shown to be as strong or even stronger an independent risk factor for postoperative TJA complications than obesity. In some cases higher complications were seen which some authors attribute to bariatric patients remaining in a catabolic state after weight loss.  

We know that obesity and its associated comorbid conditions do have worse outcomes and increased complications in TJA patients. We also know that complications proportionately increase with increasing severity of obesity. The super-obese population is at the greatest risk of complication following TJA and preoperative screening and management is essential in reducing complications. Although weight loss is important, bariatric data has shown that it does not solve the problem of obesity in itself and the patient's metabolic state is likely a more important issue. Implant selection is important and strong consideration should be given to avoiding direct anterior approach in the THA obese patient. Understanding of obesity specific complications and treatment options is crucial for patient counseling and optimization to ensure successful treatment in obese TJA patients.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_8 | Pages 42 - 42
1 May 2019
Jones R
Full Access

The development of more wear resistant biomaterials and better locking mechanisms for the polyethylene into the tibial base has significantly reduced polyethylene wear as a reason for revision TKA. Aseptic loosening is now the primary cause for revision TKA. Loosening can be caused by multifactorial operative issues: 1] patient selection, 2] implant alignment, 3] cementing technique. Furthermore, aseptic loosening occurs at a consistent rate over time. Increased cement penetration is important to counter bone resorption. Increasing penetration also improves cement mantle toughness leading to better mechanical integrity of the bone-cement interface and reduces bone-cement interface stress.

It is important to recognise that a cleaner and drier interface does improve bone-cement penetration. Techniques to improve the process include better cement formulations, drilling sclerotic bone, devices and implant features to increase pressurization, using negative pressure suction ports in the tibia. We have extensive experience with CarboJet, a method of CO2 gas jet cleaning and drying. This experience was developed during 20 years of performing TKA with NO tourniquet. Schnetler et al found that the “use of a tourniquet in TKA causes a paradoxical increase in total blood loss”. So, NO tourniquet TKA is becoming the new paradigm for knee arthroplasty in reconstructive orthopaedics. Goldstein reported that pressurised carbon dioxide jet lavage resulted in a 35% increase in cement penetration depth when used vs. use of pulsatile saline lavage alone. Meneghini used this pressurised carbon dioxide system to study the influence of NO tourniquet use in TKA. He found a significant lowering of opioid consumption postoperatively.

Another important factor in increasing the cement interdigitation is the influence of lipids which significantly weakens the bond at the interfaces. If motion is allowed during cementation there is additional loss of penetration and therefore fixation. The pressurised carbon dioxide delivered by the CarboJet system actually pushes the lipid, fatty marrow up and out of the bone allowing it to be suctioned or lap dried from the interface surface. The NO tourniquet technique and the use of carbon dioxide jet gas delivery to improve the bone-cement interface in TKA will be demonstrated.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 23 - 23
1 Apr 2019
Greene A Hamilton M Polakovic S Mohajer N Youderian A Wright T Parsons I Saadi P Cheung E Jones R
Full Access

INTRODUCTION

Variability in placement of total shoulder arthroplasty (TSA) glenoid implants has led to the increased use of 3D CT preoperative planning software. Computer assisted surgery (CAS) offers the potential of improved accuracy in TSA while following a preoperative plan, as well as the flexibility for intraoperative adjustment during the procedure. This study compares the accuracy of implantation of reverse total shoulder arthroplasty (rTSA) glenoid implants using a CAS TSA system verses traditional non-navigated techniques in 30 cadaveric shoulders relative to a preoperative plan from 3D CT software.

METHODS

High resolution 1mm slice thickness CT scans were obtained on 30 cadaveric shoulders from 15 matched pair specimens. Each scan was segmented and the digital models were incorporated into a preoperative planning software. Five fellowship trained orthopedic shoulder specialists used this software to virtually place a rTSA glenoid implant as they deemed best fit in six cadavers each. The specimens were randomized with respect to side and split into a cohort utilizing the CAS system and a cohort utilizing conventional instrumentation, for a total of three shoulders per cohort per surgeon. A BaSO4 PEEK surrogate implant identical in geometry to the metal implant used in the preoperative plan was used in every specimen, to maintain high CT resolution while minimizing CT artifact. The surgeons were instructed to implant the rTSA implants as close to their preoperative plans as possible for both cohorts. In the CAS cohort, each surgeon used the system to register the native cadaveric bones to each respective CT, perform the TSA procedure, and implant the surrogate rTSA implant. The surgeons then performed the TSA procedure on the opposing side of the matched pair using conventional instrumentation.

Postoperatively, CT scans were repeated on each specimen and segmented to extract the digital models. The pre- and postoperative scapulae models were aligned using a best fit match algorithm, and variance between the virtual planned position of the implant and the executed surgical position of the implant was calculated [Fig 1].


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 113 - 113
1 Apr 2019
Verstraete M Conditt M Wright T Zuckerman J Youderian A Parsons I Jones R Decerce J Goodchild G Greene A Roche C
Full Access

Introduction & Aims

Over the last decade, sensor technology has proven its benefits in total knee arthroplasty, allowing the quantitative assessment of tension in the medial and lateral compartment of the tibiofemoral joint through the range of motion (VERASENSE, OrthoSensor Inc, FL, USA). In reversal total shoulder arthroplasty, it is well understood that stability is primarily controlled by the active and passive structures surrounding the articulating surfaces. At current, assessing the tension in these stabilizing structures remains however highly subjective and relies on the surgeons’ feel and experience. In an attempt to quantify this feel and address instability as a dominant cause for revision surgery, this paper introduces an intra-articular load sensor for reverse total shoulder arthroplasty (RTSA).

Method

Using the capacitive load sensing technology embedded in instrumented tibial trays, a wireless, instrumented humeral trial has been developed. The wireless communication enables real-time display of the three-dimensional load vector and load magnitude in the glenohumeral joint during component trialing in RTSA. In an in-vitro setting, this sensor was used in two reverse total shoulder arthroplasties. The resulting load vectors were captured through the range of motion while the joint was artificially tightened by adding shims to the humeral tray.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 63 - 63
1 Apr 2019
Greene A Cheung E Polakovic S Hamilton M Jones R Youderian A Wright T Saadi P Zuckerman J Flurin PH Parsons I
Full Access

INTRODUCTION

Preoperative planning software for anatomic total shoulder arthroplasty (ATSA) allows surgeons to virtually perform a reconstruction based off 3D models generated from CT scans of the glenohumeral joint. The purpose of this study was to examine the distribution of chosen glenoid implant as a function of glenoid wear severity, and to evaluate the inter-surgeon variability of optimal glenoid component placement in ATSA.

METHODS

CT scans from 45 patients with glenohumeral arthritis were planned by 8 fellowship trained shoulder arthroplasty specialists using a 3D preoperative planning software, planning each case for optimal implant selection and placement. The software provided three implant types: a standard non-augmented glenoid component, and an 8° and 16° posterior augment wedge glenoid component. The software interface allowed the surgeons to control version, inclination, rotation, depth, anterior- posterior and superior-inferior position of the glenoid components in 1mm and 1° increments, which were recorded and compared for final implant position in each case.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 64 - 64
1 Apr 2019
Greene A Cheung E Polakovic S Hamilton M Jones R Youderian A Wright T Saadi P Zuckerman J Flurin PH Parsons I
Full Access

INTRODUCTION

Preoperative planning software for reverse total shoulder arthroplasty (RTSA) allows surgeons to virtually perform a reconstruction based off 3D models generated from CT scans of the glenohumeral joint. While anatomical studies have defined the range of normal values for glenoid version and inclination, there is no clear consensus on glenoid component selection and position for RTSA. The purpose of this study was to examine the distribution of chosen glenoid implant as a function of glenoid wear severity, and to evaluate the inter-surgeon variability of optimal glenoid component placement in RTSA.

METHODS

CT scans from 45 patients with glenohumeral arthritis were planned by 8 fellowship trained shoulder arthroplasty specialists using a 3D preoperative planning software, planning each case for optimal implant selection and placement. The software provided four glenoid baseplate implant types: a standard non-augmented component, an 8° posterior augment wedged component, a 10° superior augment wedged component, and a combined 8° posterior and 10° superior wedged augment component. The software interface allowed the surgeons to control version, inclination, rotation, depth, anterior-posterior and superior-inferior position of the glenoid components in 1mm and 1° increments, which were recorded and compared for final implant position in each case.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 124 - 124
1 Jun 2018
Jones R
Full Access

The development of more wear resistant biomaterials and better locking mechanisms for the polyethylene into the tibial base has significantly reduced polyethylene wear as a reason for revision TKA. Aseptic loosening is now the primary cause for revision TKA. Loosening can be caused by multifactorial operative issues: 1] patient selection, 2] implant alignment, 3] cementing technique. Furthermore, aseptic loosening occurs at a consistent rate over time. Increased cement penetration is important to counter bone resorption. Increasing penetration also improves cement mantle toughness leading to better mechanical integrity of the bone-cement interface and reduces bone-cement interface stress.

It is important to recognise that a cleaner and drier interface does improve bone-cement penetration. Techniques to improve the process include better cement formulations, drilling sclerotic bone, devices and implant features to increase pressurization, using negative pressure suction ports in the tibia. We have extensive experience with CarboJet, a method of CO2 gas jet cleaning and drying. This experience was developed during 20 years of performing TKA with NO tourniquet. Schnetler et al found that the “use of a tourniquet in TKA causes a paradoxical increase in total blood loss”. So, NO tourniquet TKA is becoming the new paradigm for knee arthroplasty in reconstructive orthopaedics. Goldstein reported that pressurised carbon dioxide jet lavage resulted in a 35% increase in cement penetration depth when used versus use of pulsatile saline lavage alone.

Another important factor in increasing the cement interdigitation is the influence of lipids which significantly weakens the bond at the interfaces. If motion is allowed during cementation there is additional loss of penetration and therefore fixation. The pressurised carbon dioxide delivered by the CarboJet system actually pushes the lipid, fatty marrow up and out of the bone allowing it to be suctioned or lap dried from the interface surface. The NO tourniquet technique and the use of carbon dioxide jet gas delivery to improve the bone-cement interface in TKA will be demonstrated.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 102 - 102
1 Jun 2018
Jones R
Full Access

Total knee arthroplasty (TKA) is one of the most common orthopaedic operations performed worldwide and it is largely successful in pain relief and functional recovery. However, when pain persists post-operatively the thorough evaluation must be instituted. Extra-articular causes of knee pain include; hip pathology, lumbar spine degenerative disease or radicular symptoms, focal neuropathy, vascular disease, and chronic regional pain syndrome. Intra-articular causes of knee pain: infection, crepitation/clunk, patella osteonecrosis, patella mal-tracking, soft tissue imbalance, malalignment, arthrofibrosis, component loosening, implant wear, ilio-tibial band irritation, and bursitis. Other causes of pain to rule out are component overhang with soft tissue irritation, recurrent hemarthrosis secondary to synovial impingement or entrapment, non-resurfaced patella, and metal sensitivity.

A careful history may reveal previous knee surgeries with delayed healing or prolonged drainage, chronology of sign and symptoms, co-morbid medical conditions, jewel or metal sensitivity.

Physical exam should help with specific signs in the operated knee. Targeted local anesthetic blocks are helpful and response to lumbar sympathetic blocks determines presence of CRPS.

Lab tests are important: ESR, CRP, WBC, aspiration with manual cell count and diff, leucocyte esterase dipstick, RA titers, metal derm patch testing, nuclear scans, CT best for rotational malalignment, and MARS MRI.

More recently patient satisfaction as an outcome measure has shown TKA results not satisfactory in 11- 18% of patients. A discordance of patient vs. surgeon satisfaction exists so the following factors may help improve this: correct patient selection, establishing and correlating surgeon-patient expectations, peri-operative optimization of patient co-morbidities to help avoid preventable complications, use of pre-operative and post-operative pathways. Satisfaction rates can best be improved by addressing the previous points with patients prior to TKA surgery.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 87 - 87
1 Aug 2017
Jones R
Full Access

The US obesity epidemic has transcended into the arthroplasty patient population and surgeons must assess whether obesity is a risk factor for poor outcomes in total joint arthroplasty (TJA) and determine how it should be managed in order to insure good clinical outcomes. In the United States, 34.9% of adults are currently obese (BMI > 30). In a recent study, 54.5% of patients reporting to arthroplasty clinics in the US were obese. We performed a recent literature review to determine how obesity impacts outcomes in total hip and knee arthroplasty and what must be done to improve outcomes in the obese arthroplasty patient.

We know that obesity and its associated comorbid conditions do have worse outcomes and increased complications in TJA patients. We also know that complications proportionately increase with increasing severity of obesity. The super-obese population is at the greatest risk of complication following TJA and pre-operative screening and management is essential in reducing complications. Although weight loss is important, our bariatric data has shown that it does not solve the problem of obesity in itself and the patient's metabolic state is likely a more important issue. Implant selection is important and strong consideration should be given to avoiding direct anterior approach in the THA obese patient. Understanding of obesity specific complications and treatment options is crucial for patient counseling and optimisation to ensure successful treatment in obese TJA patients.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 51 - 51
1 Aug 2017
Jones R
Full Access

TKA is one of the most common orthopaedic operations performed worldwide and it is largely successful in pain relief and functional recovery. However, when pain persists post-operatively the thorough evaluation must be instituted. Extra-articular causes of knee pain include; hip pathology, lumbar spine degenerative disease or radicular symptoms, focal neuropathy, vascular disease, and chronic regional pain syndrome. Intra-articular causes of knee pain: infection, crepitation/ clunk, patella osteonecrosis, patella mal-tracking, soft tissue imbalance, malalignment, arthrofibrosis, component loosening, implant wear, ilio-tibial band irritation, and bursitis. Other causes of pain to rule out are component overhang with soft tissue irritation, recurrent hemarthrosis secondary to synovial impingement or entrapment, non-resurfaced patella, and metal sensitivity.

A careful history may reveal previous knee surgeries with delayed healing or prolonged drainage, chronology of sign and symptoms, co-morbid medical conditions, jewel or metal sensitivity.

Physical exam should help with specific signs in the operated knee. Targeted local anesthetic blocks are helpful and response to lumbar sympathetic blocks determines presence of CRPS.

Lab tests are important: ESR, CRP, WBC, aspiration with manual cell count and diff, leukocyte esterase dipstick, RA titers, metal derm patch testing, nuclear scans, CT best for rotational malalignment,, and MARS MRI.

More recently patient satisfaction as an outcome measure has shown TKA results not satisfactory in 11 – 18% of patients. A discordance of patient vs. surgeon satisfaction exists so the following factors may help improve this: correct patient selection, establishing and correlating surgeon-patient expectations, peri-operative optimisation of patient comorbidities to help avoid preventable complications, use of pre- and post-operative pathways. Satisfaction rates can best be improved by addressing the previous points with patients prior to TKA surgery.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 28 - 28
1 Apr 2017
Jones R
Full Access

As the American population ages and a trend toward performing total hip arthroplasty (THA) in younger patients continues, the number of Americans undergoing THA is projected to increase over time. The advent of the bundled payment system combined with the current medical utilization climate has placed considerable pressure on surgeons to produce excellent results with early functional recovery and short hospital stays. The US obesity epidemic has transcended into the arthroplasty patient population and surgeons must assess whether obesity is a risk factor for poor outcomes in THA and determine how it should be managed. We performed a recent literature review to determine how obesity impacts outcomes in total hip arthroplasty and what must be done to improve outcomes in the obese arthroplasty patient. Our goal is to answer 3 questions: does obesity increase the complication rate in THA, if obesity matters how obese is too obese, and what must be done to improve outcomes in the obese patient?

Ultimately, obesity has been shown to correlate with increased post-operative complications in THA. The arthroplasty surgeon must optimise the obese patient prior to surgery by identifying associated comorbidities and consider malnutrition screening with counseling. Notice should be taken of the degree of obesity as patients with BMI > 40 have demonstrated much higher complication rates. Strong consideration should be given to avoiding direct anterior approach in the obese patient. Healthy weight loss must be encouraged with appropriate patient counseling and treatment in order to achieve success with THA in obese patients.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 117 - 117
1 Apr 2017
Jones R
Full Access

Functional restoration of patella kinematics is an essential component of TKA, whether the patella is replaced or not. This goal is accomplished by a multifactorial approach: establish proper component position and alignment, especially rotation; avoid IR of the femoral and ER of the tibial components; maintain correct joint line position; achieve symmetrical soft tissue balance.

Most modern TKA designs have an anatomic trochlear groove shape to enable midline tracking. Patella implants are better designed as well with three equilateral lugs for fixation and either dome or anatomic shape. The apex of the patella component should be aligned with the apex of the patella raphe which is more medial than lateral. This method leaves an island of exposed lateral patella facet which is managed with the “lateral slat technique” to be described. It is essentially an intraosseous lateral release. The early mobilization of modern TKA patients demands watertight closure to prevent soft tissue attenuation and late tracking issues.

When confronted with a patient with a laterally dislocated patella, implementation of the “lateral slat technique” should be done at the approach to obtain midline tracking. Such patients require a median parapatellar (MPP) approach and may need distal-lateral vastus medialis advancement (Insall procedure).

Adherence to the principles iterated herein will produce a happy patient with good patello-femoral kinematics and function.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 51 - 51
1 Apr 2017
Jones R
Full Access

The femur begins to bow anteriorly at the 200 mm level, but may bow earlier in smaller people. If the stem to be used is less than 200 mm, a straight stem can be used. If the stem is longer than 200 mm, it will perforate the anterior femoral cortex. I know this because I did this on a few occasions more than 20 years ago.

To use a long straight stem, there are two techniques. One can either do a diaphyseal osteotomy or one can do a Wagner split (extended trochanteric osteotomy). Both of these will put the knee in some degree of hyperextension, probably insignificant in the elderly, but it may be of significance in the young. In very young people, therefore, it may be preferable to use a bowed stem to avoid this degree of recurvatum.

There are two different concepts of loading. Diaphyseal osteotomy implies a proximal loading has been sought. The Wagner split ignores the proximal femur and seeks conical fixation in the diaphysis. There will be very little bone-bone contact between what remains of the attached femur and the detached anterior cortex so that it is important to ensure that the blood supply to the anterior cortex remains intact, preferably by using Wagner's technique, using a quarter-inch osteotome inserted through the vastus to crack the medial cortex. Current modularity is of two types. Distal modularity was attempted many years ago and was never successful.

Proximal modularity, as for example, the S-ROM stem, implies various sizes of sleeves fit onto the stem to get a proximal canal fill. In mid-stem modularity, the distal stem wedges into the cone. It has to be driven into where it jams and this can be somewhat unpredictable. For this reason, the solid Wagner stem has been replaced by the mid-stem modular. Once the distal femur is solidly embedded, the proximal body is then selected for height and version. The proximal body is unsupported in the mid-stem modular and initially, few fractures were noted at the taper junction. Cold rolling, shot peening and taper strengthening seem to have solved these problems.

There are a variety of types of osteotomy, which can be used for different deformities. With a mid-stem modular system, generally, all that needs to be done is a Wagner-type split and fixation is sought in the mid-diaphysis by conical reaming. No matter what stem is used, distal stability is necessary. This is achieved by flutes, which engage the endosteal cortex. The flutes alone must have sufficient rotational stability to overcome the service loads on the hip of 22 Nm.

I divide revision into three categories. In type one, the isthmus is intact, i.e. the bone below the lesser trochanter so that a primary stem can be used. In type two, the isthmus is damaged, i.e. the bone below the lesser trochanter, so a long revision stem is required. In a type three, there is more than 70 mm of missing proximal femur. The Wagner stem may be able to handle this on its own, but most other stems are better supported with a structural allograft cemented to the stem.

The reported long term results of mid-stem modular revision implants are good as in most, over 90% survivorship. The introduction of modularity appears to have overcome initial disadvantage of the Wagner stem, i.e. its unpredictability in terms of leg length.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 123 - 123
1 Mar 2017
Roche C Greene A Flurin P Wright T Zuckerman J Jones R
Full Access

Introduction

Humeral radiolucent lines after anatomic TSA (aTSA) have been well described; however, little clinical consequences have been attributed to them. The recent emergence of shorter humeral stems has demonstrated higher incidences of humeral radiolucencies than has been reported historically with standard length components. This large scale database analysis quantifies and compares the clinical outcomes of aTSAs with and without radiolucent humeral lines using one specific prosthesis to determine their impact on clinical outcomes.

Methodology

This is a multicenter, retrospective, case controlled radiographic and clinical review. Preoperative and postoperative data was analyzed from 671 aTSA patients with a minimum of 2 years followup. 538 of these 671 aTSA patients had full radiographic followup (80.2%) and were included in this study; these patients had an average followup of 45.3 months). 459 patients had noncemented humeral stems; whereas, 79 patients had cemented humeral stems. Radiographs were reviewed at latest follow up for humeral radiolucent lines based on the technique described by Gruen et al. Patients were evaluated and scored pre-operatively and at latest follow-up using the SST, UCLA, ASES, Constant, and SPADI scoring metrics; ROM was also recorded. A Student's two-tailed, unpaired t-test was used to identify differences in pre-operative, post-operative, and improvement in results, where p<0.05 denoted a significant difference.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 143 - 143
1 Feb 2017
Greene A Hamilton M Polakovic S Andrews R Jones R Parsons I Saadi P Cheung E Flurin P Wright T
Full Access

INTRODUCTION

As computer navigated surgery continues to progress to the forefront of orthopedic care, the application of a navigated total shoulder arthroplasty has yet to appear. However, the accuracy of these systems is debated, as well as the dilemma of placing an accurate tool in an inaccurate hand. Often times a system's accuracy is claimed or validated based on postoperative imaging, but the true positioning is difficult to verify. In this study, a navigation system was used to preoperatively plan, guide, and implant surrogate shoulder glenoid implants and fiducials in nine cadaveric shoulders. A novel method to validate the position of these implants and accuracy of the system was performed using pre and post operative high resolution CT scans, in conjunction with barium sulfate impregnated PEEK surrogate implants.

METHODS

Nine cadaveric shoulders were CT scanned with .5mm slice thickness, and the digital models were incorporated into a preoperative planning software. Five orthopedic shoulder specialists used this software to virtually place aTSA and rTSA glenoid components in two cadavers each (one cadaver was omitted due to incomplete implantation), positioning the components as they best deemed fit. Using a navigation system, each surgeon registered the native cadaveric bone to each respective CT. Each surgeon then used the navigation system to guide him or her through the total shoulder replacement, and implant the barium sulfate impregnated PEEK surrogate implants. Four cylindrical PEEK fiducials were also implanted in each scapula to help triangulate the position of the surrogate implants. Previous efforts were attempted with stainless steel alloy fiducials, but position and image accuracy were limited by CT artifact. BaSO4 PEEK provided the highest resolution on a postoperative CT with as little artifact as possible. All PEEK fiducials and surrogate implants were registered by probing points and planes with the navigation system to capture the digital position. A high resolution post operative CT scan of each specimen was obtained, and variance between the executed surgical plan and PEEK fiducials was calculated.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 85 - 85
1 Dec 2016
Jones R
Full Access

Obtaining primary wound healing in total joint arthroplasty (TJA) is essential to a good result. Wound healing disturbances (WHD) can occur and the consequences can be devastating to the patient and to the surgeon. Determination of the host healing capacity can be useful in predicting complications. Cierney and Mader classified patients as Type A: no healing compromises and Type B: systemic or local healing compromise factors present. Local factors include traumatic arthritis with multiple previous incisions, extensive scarring, lymphodema, poor vascular perfusion, and excessive local adipose deposition. Systemic compromising factors include diabetes, rheumatic diseases, renal or liver disease, immunocompromise, steroids, smoking, and poor nutrition. Low serum albumin, total lymphocyte count, and low transferrin increase WHD. In high risk situations the surgeon should encourage positive patient choices such as smoking cessation and nutritional supplementation to modify healing responses. Use of tourniquet in obese patients also increases WHD.

Careful planning of incisions, particularly in patients with scarring or multiple previous operations, is productive. Around the knee the vascular viability is better in the medial flap. Thusly, use the most lateral previous incision, do minimal undermining, and handle tissue meticulously. We do all potentially complicated TKA's without tourniquet to enhance blood flow and tissue viability. The use of perioperative anticoagulation will increase wound problems.

If wound drainage or healing problems do occur, immediate action is required. Deep sepsis can be ruled out with a joint aspiration and cell count (less than 2500), differential (less than 60% polys), and negative culture and sensitivity. All hematomas should be evacuated and necrosis or dehiscence should be managed by debridement to obtain a live wound.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 98 - 98
1 Dec 2016
Jones R
Full Access

The major benefit of TKA with tourniquet is operating in a bloodless field. A possible secondary benefit is a better cement-bone interface for fixation.

The disadvantages of tourniquet use for TKA include multiple risk factors both local and systemic: Nerve damage, Altered hemodynamics with limb exsanguinations (15–20% increase in circulatory volume) and reactive hyperemia with tourniquet release (10% increase in limb size increasing soft tissue tension and secondary pain), Delay in recovery of muscle function, Increased risk of DVT with direct trauma to vessel walls and increased levels of thrombin-antithrombin complexes, A 5.3x greater risk for large venous emboli propagation and transesophageal echogenic particles, Vascular injury with higher risk in atherosclerotic, calcified arteries, Increase in wound healing disturbances, Obese patients TKA with tourniquet show impaired endothelial function and more DVTs.

Our initial experience with TKA without tourniquet was in high risk patients with previous DVT or PE, multiple scarring, or compromised cardiovascular status. We have used this method on all patients for the last 14 years. The protocol includes regional anesthesia, incision and approach made with 90-degree knee flexion, meticulous hemostasis, jet lavage and filtered carbon dioxide delivered to dry and prepare bone beds for cementation, application of topical tranexamic acid and routine closure. We have encountered no differences in blood loss or transfusion rates, cement penetration/ fixation, less postoperative pain, faster straight leg raise and knee flexion gains, and fewer wound healing disturbances. We recommend TKA sans tourniquet. Let it bleed!


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 33 - 33
1 Nov 2016
Jones R
Full Access

In the USA, 34.9% of adults are currently obese (BMI > 30). Growth in total knee arthroplasty (TKA) is outpacing growth in total hip arthroplasty (THA) largely due to a differential utilization of TKA in overweight patients in the USA. In a recent study, 54.5% of patients reporting to arthroplasty clinics in the USA were obese. From 2006–2010, 61.2% of primary unilateral TKA patients in the USA ACS-NSQIP database were obese. Arthroplasty surgeons are directly affected by the obesity epidemic and need to understand how to safely offer a range of peri-operative care for these patients in order to insure good clinical outcomes.

Pre-operative care for the obese patient involves nutritional counseling, weight loss methods, consideration for bariatric surgery, physical therapy, metabolic workup, and diagnosis and management of frequent comorbid conditions (OSA, DM2, HTN, HLD). Obese patients must also be counseled on their increased risk of complications following TKA.

In the operating room, several steps can be taken to insure success when performing TKA on obese patients. We recommend performing TKA without the use of a tourniquet in order to prevent fat necrosis and increased pain. The incision is made in 90 degrees of knee flexion, atypically midline proximally and curved distally to the midpoint between the tubercle and the medial edge of the tibia. Care is used to minimise the creation of dead space, and the approach to the knee is an extensile medial parapatellar incision. Closure is in multiple layers. The use of negative pressure dressing following surgery can minimise the early wound drainage that is frequently seen after TKA in obese patients.

Post-operative care of the obese patient following TKA involves several unique considerations. Chronic pain and obesity are frequent comorbid conditions and post-operative pain control regimens need to be tailored. Although the physical therapy regimen does not differ in obese patients, obese patients are more likely to be discharged to a rehabilitation facility.

Obese patients have a higher rate of all complications compared to healthy weight. All infection and deep infection increased in obese patients in large meta-analysis. Patients with BMI > 35 are 6.7 times more likely to develop infection after TKA. Patients with BMI > 40 have a 3.35 times higher rate of revision for deep infection than those with BMI < 35. The odds ratio for major complications increases dramatically beyond BMI > 45.

Although there are a few studies that have demonstrated worse clinical outcome in obese patients following TKA, most studies show no difference in clinical outcomes at short- or long-term follow-up. The arthroplasty surgeon must optimise the obese patient prior to surgery, use intra-operative techniques to maximise success, and anticipate potential problems in the post-operative course in order to achieve success with TKA in obese patients.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 63 - 63
1 Nov 2016
Jones R
Full Access

Persistent post-surgical pain (PPSP) remains a problem after knee replacement with some studies reporting up to 20% incidence. Pain is usually felt by those who do not operate to be a monolithic entity. All orthopaedic surgeons know that this is not the case. At its most basic level, pain can be divided into two categories, mechanical and non-mechanical.

Mechanical pain is like the pain of a fresh fracture. If the patient does not move, the pain is less. This type of pain is relieved by opiates. Mechanical pain is seen following knee replacement, but is becoming less frequent. It is caused by a combination of malrotations and maltranslations, often minor, which on their own would not produce problems. The combination of them, however, may produce a knee in which there is overload of the extensor mechanism or of the medial stabilizing structures. If these minor mechanical problems can be identified, then corrective surgery will help.

Non-mechanical pain is present on a constant basis. It is not significantly worsened by activities. Opiates may make the patient feel better, but they do not change the essential nature of the pain. Non-mechanical pain falls into three broad groups, infection, neuropathic and perceived pain. Infection pain is usually relieved by opiates. Since some of this pain is probably due to pressure, its inclusion in the non-mechanical pain group is questionable, but it is better left there so that the surgeon always considers it. Low grade chronic infection can be extremely difficult to diagnose. Loosening of noncemented knee components is so rare that when it is noted radiologically, infection should be very high on the list of suspicions. The name neuropathic pain suggests that we know much more about it than we do in reality. Causalgia or CRPS-type two is rare following knee replacement. CRPS-type one or reflex sympathetic dystrophy probably does exist, but it is probably over-diagnosed. The optimum treatment I have found is lumbar sympathetic blocks. Lyrica, Gabapentin and Cymbalta may also help. Perceived pain is the largest group. It does not matter what you tell the patient, some believe a new knee should be like a new car, i.e. you step into it and drive away. The fact that they have to work to make it work is horrifying. Perceived pain is widespread. The classic treatise, Dr. Ian McNabb's book “Backache”, should be studied by all who wish to understand pain complaints.

Any experienced knee surgeon will have his list of red flags or caveats. I will list only a few. If the patient comes in with a form asking for a disability pension on the first visit. If the patient's mother answers the questions. If the patient comes in taking massive doses of opiates. If the patient is referred to you by a surgeon who does more knee replacements than you do.

There are other issues such as good old fibromyalgia, which appears to have gone the way of the dodo. It has been replaced by something equally silly called central sensitization. The theory of central sensitization is that if one has pain somewhere or other for three months or six months or whatever, there are going to be changes in the brain and spinal cord. It then does not matter what happens to the original pain, i.e. whether or not it goes away, the pain will persist because of the changes in the brain, hence, the title of the pain in the brain syndrome. If this theory was correct, we might as well all go home because we have all been wasting our time for the last 30 years because none of our patients would get any better. After all, all of our patients have had pain for a lot longer than three months, many of them have been involved in trauma and sometimes, compensation is at issue. The pain in the brain theory, therefore, sounds about as realistic as the flat earth society or the treatment of Galileo.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_17 | Pages 42 - 42
1 Nov 2016
Jones R
Full Access

Functional restoration of patella kinematics is an essential component of TKA, whether the patella is replaced or not. This goal is accomplished by a multifactorial approach: establish proper component position and alignment, especially rotation, avoid IR of the femoral and ER of the tibial components, maintain correct joint line position, achieve symmetrical soft tissue balance

Most modern TKA designs have an anatomic trochlear groove shape to enable midline tracking. Patella implants are better designed as well with three equilateral lugs for fixation and either dome or anatomic shape. The apex of the patella component should be aligned with the apex of the patella raphe which is more medial than lateral. This method leaves an island of exposed lateral patella facet which is managed with the “lateral slat technique” to be described. It is essentially an intraosseous lateral release. The early mobilization of modern TKA patients demands watertight closure to prevent soft tissue attenuation and late tracking issues.

When confronted with a patient with a laterally dislocated patella, implementation of the “lateral slat technique” should be done at the approach to obtain midline tracking. Such patients require a median parapatellar (MPP) approach and may need distal-lateral vastus medialis advancement (Insall procedure).

Adherence to the principles iterated herein will produce a happy patient with good patello-femoral kinematics and function.


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1479 - 1488
1 Nov 2016
Kalson NS Borthwick LA Mann DA Deehan DJ Lewis P Mann C Mont MA Morgan-Jones R Oussedik S Williams FMK Toms A Argenson JN Bellemans J Bhave A Furnes O Gollwitzer H Haddad FS Hofmann S Krenn V

Aims

The aim of this consensus was to develop a definition of post-operative fibrosis of the knee.

Patients and Methods

An international panel of experts took part in a formal consensus process composed of a discussion phase and three Delphi rounds.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 9 - 9
1 May 2016
Roche C Flurin P Grey S Wright T Zuckerman J Jones R
Full Access

Introduction

Due to the predictability of outcomes achieved with reverse shoulder arthroplasty (rTSA), rTSA is increasingly being used in patients where glenoid fixation is compromised due to presence of glenoid wear. There are various methods to achieve glenoid fixation in patients with glenoid wear, including the use of bone grafting behind the glenoid baseplate or the use of augmented glenoid baseplates. This clinical study quantifies clinical outcomes achieved using both techniques in patients with severe glenoid wear at 2 years minimum follow-up.

Methods

80 patients (mean age: 71.6yrs) with 2 years minimum follow-up were treated by 7 fellowship trained orthopaedic surgeons using rTSA with bone graft behind the baseplate or rTSA with an augmented glenoid baseplate in patients with severe posterior glenoid wear. 39 rTSA patients (14 female, avg: 73.1 yrs; 25 male, avg: 71.5 yrs) received an augmented glenoid (cohort composed of 24 patients with an 8° posterior augment baseplate and 15 patients with a 10° superior augment baseplate) for treatment of CTA, RCT, and OA with a medially eroded scapula. 41 rTSA patients (27 female, avg: 73.0 yrs; 14 male, avg: 66.9 yrs) received glenoid bone graft (cohort composed of 5 patients with allograft and 36 patients with autograft) for treatment of CTA, RCT, and OA with a medially eroded scapula. Outcomes were scored using SST, UCLA, ASES, Constant, and SPADI metrics; active abduction, forward flexion, and internal/external rotation were also measured to quantify function. Average follow-up was 31.2 months (augment 28.3; graft 34.1). A two-tailed, unpaired t-test identified differences (p<0.05) in pre-operative, post-operative, and pre-to-post improvements.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 69 - 69
1 Dec 2015
Williams R Kotwal R Roberts-Huntley N Khan W Morgan-Jones R
Full Access

At first-stage revision surgery for infection of total knee arthroplasties, antibiotic-impregnated cement spacers are frequently implanted. Two types of cement spacers are commonly used, “static” and “articulating” cement spacers. Advocates of cement spacers state that they deliver high doses of antibiotics locally, increase patient comfort, allow mobility and provide joint stability. They also minimize contracture of collateral ligaments, thereby facilitating re-implantation of a definitive prosthesis at a later stage. The use of these cement spacers, however, are not without significant complications, including patella tendon injuries.

We describe a series of three patients who sustained patella tendon injuries in infected total knee arthroplasties following the use of a static cement spacer at first-stage knee revision.

The patella tendon injuries resulted in significant compromise to wound healing and knee stability requiring multiple surgeries. The mid-term function was poor with an Oxford score at 24 months ranging from 12–20

Based on our experience, we advise caution in the use of static cement spacer blocks. If they are to be used, we recommend that they should be keyed in the bone to prevent patella tendon injuries.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 66 - 66
1 Dec 2015
Khan W Williams R Metah A Morgan-Jones R
Full Access

Honey has been used as a topical antiseptic for at least 5,000 years. SurgiHoney is a CE licensed sterile product, which has been proven to be non-toxic and effective when used topically in the treatment of chronically infected wounds. The key difference from other medical grade honey is the broad spectrum antimicrobial characteristics with activity against Gram +ve, Gram –ve and multi-resistant organisms. Its novel role against the bacterial bioburden and biofilm associated with periprosthetic infections around total knee arthroplasties (TKA's) is therefore considered.

SurgiHoney was used as an implant coating immediately prior to wound closure after implantation of salvage endoprosthesis for multiply revised, infected TKA's undergoing staged reconstruction.

We report a consecutive series of multi-revised, infected revision TKA's where SurgiHoney was used as an active antimicrobial coating. We discuss its intra-operative application and early clinical outcomes.

The use of Surgihoney as a novel anti-microbial is established in the management of complex wound infections. This is the first reported use of SurgiHoney as a deep, implant coating in the salvage of prosthetic joint infection.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_16 | Pages 64 - 64
1 Dec 2015
Williams R Khan W Huntley N Morgan-Jones R
Full Access

Joint degeneration may make a total knee arthroplasty (TKA) a requirement for pain relief and function. However, the presence of ipsilateral limb osteomyelitis (OM) makes surgical management extremely challenging.

We report the experience of a high volume revision knee surgeon managing ipsilateral limb multi resistant OM and the outcome of subsequent TKA.

Four consecutive patients were identified who had either ipsilateral femoral or tibial chronic osteomyelitis treated prior to undergoing TKA. Surgery to eradicate the osteomyelitis involved a Lautenbach compartmental debridement, and where necessary, healing by secondary intention. The decision to proceed to a TKA was based on history, clinical examination and radiological findings of advanced osteoarthritic change.

The patients had a mean age of 50 years. They had a background of multi-organism OM and underwent single-stage TKAs at an average of 63 months following eradication of the underlying OM.

Three patients did well but had complications associated with poor skin and soft tissues, and abnormal bone anatomy. One patient developed an infection and following a re-revision had an arthrodesis.

The results for the four cases are summarised in Table 1.

We have highlighted that patients with ipsilateral limb multi resistant OM are a difficult cohort to manage.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 51 - 51
1 Dec 2015
Williams R Khan W Williams H Abbas A Mehta A Ayre W Morgan-Jones R
Full Access

A common step to revision surgery for infected total knee replacement (TKR) is a thorough debridement. Whilst surgical and mechanical debridement are established as the gold standard, we investigate a novel adjuvant chemical debridement using an Acetic Acid (AA) soak that seeks to create a hostile environment for organisms, further degradation of biofilm and death of the bacteria.

We report the first orthopaedic in vivo series using AA soak as an intra-operative chemical debridement agent for treating infected TKR's. We also investigate the in vitro efficacy of AA against bacteria isolated from infected TKR's.

A prospective single surgeon consecutive series of patients with infected TKR were treated according to a standard debridement protocol. Patients in the series received sequential debridement of surgical, mechanical and finally chemical debridement with a 10 minute 3% AA soak.

In parallel, we isolated, cultured and identified bacteria from infected TKR's and assessed the in vitro efficacy of AA. Susceptibility testing was performed with AA solutions of different concentrations as well as with a control of a gentamicin sulphate disc. The effect of AA on the pH of tryptone soya was also monitored in an attempt to understand its potential mechanism of action.

Physiological responses during the AA soak were unremarkable. Intraoperatively, there were no tachycardic or arrythmic responses, any increase in respiratory rate or changes in blood pressure. This was also the case when the tourniquet was released. In addition, during the post-operative period no increase in analgesic requirements or wound complications was noted. Wound and soft tissue healing was excellent and there have not been any early recurrent infections at mean of 18 months follow up.

In vitro, zones of inhibition were formed on less than 40% of the organisms, demonstrating that AA was not directly bactericidal against the majority of the clinical isolates. However, when cultured in a bacterial suspension, AA completely inhibited the growth of the isolates at concentrations as low as 0.19%v/v.

This study has shown that the use of 3% AA soak, as part of a debridement protocol, is safe. Whilst the exact mechanism of action of acetic acid is yet to be determined, we have demonstrated that concentrations as low as 0.19%v/v in solution in vitro is sufficient to completely inhibit bacterial growth from infected TKR's.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 61 - 61
1 Nov 2015
Jones R
Full Access

Obtaining primary wound healing in Total Joint Arthroplasty (TJA) is essential to a good result. Wound healing problems can occur and the consequences can be devastating to the patient and to the surgeon. Determination of the host healing capacity can be useful in predicting complications. Cierney and Mader classified patients as Type A: no healing compromises and Type B: systemic or local healing compromises factors present. Local factors include traumatic arthritis with multiple previous incisions, extensive scarring, lymphedema, poor vascular perfusion, and excessive local adipose deposition. Systemic compromising factors include diabetes, rheumatic diseases, renal or liver disease, immunocompromise, steroids, smoking, and poor nutrition. In high risk situations the surgeon should encourage positive patient choices such as smoking cessation and nutritional supplementation to elevate the total lymphocyte count and total albumin.

Careful planning of incisions, particularly in patients with scarring or multiple previous operations, is productive. Around the knee the vascular viability is better in the medial flap. Thusly, use the most lateral previous incision, do minimal undermining, and handle tissue meticulously. We do all potentially complicated TKAs without tourniquet to enhance blood flow and tissue viability. The use of peri-operative anticoagulation will increase wound problems.

If wound drainage or healing problems do occur immediate action is required. Deep sepsis can be ruled out with a joint aspiration and cell count [less than 2500], differential [less than 60% polys], and negative culture and sensitivity. All hematomas should be evacuated and necrosis or dehiscence should be managed by debridement to obtain a live wound.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_13 | Pages 42 - 42
1 Nov 2015
Jones R
Full Access

The major benefit of TKA with tourniquet is operating in a bloodless field. A possible secondary benefit is a better cement bone interface for fixation.

The disadvantages of tourniquet use for TKA include multiple risk factors both local and systemic: Nerve damage; Altered hemodynamics with limb exsanguinations (15–20% increase in circulatory volume) and reactive hyperemia with tourniquet release (10% increase in limb size increasing soft tissue tension and secondary pain); Delay in recovery of muscle function; Increased risk of DVT with direct trauma to vessel walls and increased levels of thrombin-antithrombin complexes; A 5.3× greater risk for large venous emboli propagation and transesophageal echogenic particles; Vascular injury with higher risk in atherosclerotic, calcified arteries; Increase in wound healing disturbances.

Our initial experience with TKA without tourniquet was in high risk patients with previous DVT or PE, multiple scarring, or compromised cardiovascular status. We have used this method on all patients for the last eight years. The protocol includes regional anesthesia, incision and approach made with 90-degree knee flexion, meticulous hemostasis, jet lavage and filtered carbon dioxide delivered to dry and prepare bone beds for cementation, application of topical tranexamic acid and routine closure. We have encountered no differences in blood loss or transfusion rates, less post-operative pain, faster straight leg raise and knee flexion gains, and fewer wound healing disturbances. We recommend TKA sans tourniquet. Let it bleed!


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_1 | Pages 128 - 128
1 Feb 2015
Jones R
Full Access

Functional restoration of patella kinematics is an essential component of TKA, whether the patella is replaced or not. This goal is accomplished by a multifactorial approach: establish proper component position and alignment, especially rotation; avoid IR of the femoral and ER of the tibial components; maintain correct joint line position; achieve symmetrical soft tissue balance.

Most modern TKA designs have an anatomic trochlear groove shape to enable midline tracking. Patella implants are better designed as well with three equilateral lugs for fixation and either dome or anatomic shape. The apex of the patella component should be aligned with the apex of the patella raphe which is more medial than lateral. This method leaves an island of exposed lateral patella facet which is managed with the “lateral slat technique” to be described. It is essentially an intraosseous lateral release. The early mobilization of modern TKA patients demands watertight closure to prevent soft tissue attenuation and late tracking issues.

When confronted with a patient with a laterally dislocated patella, implementation of the “lateral slat technique” should be done at the approach to obtain midline tracking. Such patients require a median parapatellar (MPP) approach and may need distal-lateral vastus medialis advancement (Insall Procedure).

Adherence to the principles iterated herein will produce a happy patient with good patello-femoral kinematics and function.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_1 | Pages 71 - 71
1 Feb 2015
Jones R
Full Access

The major benefit of TKA with tourniquet is operating in a bloodless field. A possible secondary benefit is a better cement bone interface for fixation.

The disadvantages of tourniquet use for TKA include multiple risk factors both local and systemic - Nerve damage; Altered hemodynamics with limb exsanguinations (15‐20% increase in circulatory volume) and reactive hyperemia with tourniquet release (10% increase in limb size increasing soft tissue tension and secondary pain); Delay in recovery of muscle function; Increased risk of DVT with direct trauma to vessel walls and increased levels of thrombin-antithrombin complexes; A 5.3x greater risk for large venous emboli propagation and transesophageal echogenic particles; Vascular injury with higher risk in atherosclerotic, calcified arteries; Increase in wound healing disturbances.

Our initial experience with TKA without tourniquet was in high risk patients with previous DVT or PE, multiple scarring, or compromised cardiovascular status. We have used this method on all patients for the last eight years. The protocol includes regional anesthesia, incision and approach made with 90-degree knee flexion, meticulous hemostasis, jet lavage and filtered carbon dioxide delivered to dry and prepare bone beds for cementation, application of topical tranexamic acid and routine closure. We have encountered no differences in blood loss or transfusion rates, less postoperative pain, faster straight leg raise and knee flexion gains, and fewer wound healing disturbances. We recommend TKA sans tourniquet. Let it bleed!


The Bone & Joint Journal
Vol. 97-B, Issue 2 | Pages 147 - 149
1 Feb 2015
Morgan-Jones R Oussedik SIS Graichen H Haddad FS

Revision knee arthroplasty presents a number of challenges, not least of which is obtaining solid primary fixation of implants into host bone. Three anatomical zones exist within both femur and tibia which can be used to support revision implants. These consist of the joint surface or epiphysis, the metaphysis and the diaphysis. The methods by which fixation in each zone can be obtained are discussed. The authors suggest that solid fixation should be obtained in at least two of the three zones and emphasise the importance of pre-operative planning and implant selection.

Cite this article: Bone Joint J 2015;97-B:147–9.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 180 - 180
1 Jul 2014
Sultan J Chapman G Jones R
Full Access

Summary

This study shows a significant reduction in knee adduction moment in patients with medial compartment osteoarthritis, in both the symptomatic and asymptomatic knees. Long-term follow-up studies are required to confirm the effect of treating the asymptomatic side on disease progression.

Background

The knee is the commonest joint to be affected by osteoarthritis, with the medial compartment commonly affected. Knee osteoarthritis is commonly bilateral, yet symptoms may initially present unilaterally. Higher knee adduction moment has been associated with the development and progression of medial compartment knee osteoarthritis. The aim of this study was to assess the effect of lateral wedge insoles on the asymptomatic knee of patients with unilateral symptoms of medial compartment knee osteoarthritis.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_12 | Pages 51 - 51
1 Jul 2014
Jones R
Full Access

Infection after total knee arthroplasty poses formidable challenges to the surgeon. Once an infection is diagnosed, the identification of the organism and its sensitivity to antibiotics is essential. The host's healing capacity is vital. Optimisation of modifiable comorbidities, supplemental nutrition and cessation of smoking can improve wound healing. Surgical goals include debridement of necrotic tissue and elimination of the dead space. Intravenous antibiotics and a two-stage protocol are the standard of care. At our institution, the first stage is performed with an implant and antibiotic-cement composite. This articulating spacer maintains limb length and tissue compliance. The patient can maintain a functional status between stages. Definitive reconstruction is more readily accomplished with this method in contrast to the static spacer approach. The clinical efficacy of this protocol has been well documented in the literature.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_12 | Pages 25 - 25
1 Jul 2014
Jones R
Full Access

The major benefit of TKA with tourniquet is operating in a bloodless field. A possible secondary benefit is a better cement bone interface for fixation.

The disadvantages of tourniquet use for TKA include multiple risk factors both local and systemic.

Nerve damage

Altered hemodynamics with limb exsanguinations (15–20% increase in circulatory volume) and reactive hyperemia with tourniquet release (10% increase in limb size increasing soft tissue tension and secondary pain)

Delay in recovery of muscle function

Increased risk of DVT with direct trauma to vessel walls and increased levels of thrombin-antithrombin complexes

A 5.3x greater risk for large venous emboli propagation and transesophageal echogenic particles

Vascular injury with higher risk in atherosclerotic, calcified arteries

Increase in wound healing disturbances

Our initial experience with TKA without tourniquet was in high risk patients with previous DVT or PE, multiple scarring, or compromised cardiovascular status. We have used this method on all patients for the last eight years. The protocol includes regional anesthesia, incision and approach made with 90-degree knee flexion, meticulous hemostasis, jet lavage and filtered carbon dioxide delivered to dry and prepare bone beds for cementation, application of topical tranexamic acid and routine closure. We have encountered no differences in blood loss or transfusion rates, less post-op pain, faster straight leg raise and knee flexion gains, and fewer wound healing disturbances. We recommend TKA sans tourniquet. Let it bleed!


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_8 | Pages 77 - 77
1 May 2014
Jones R
Full Access

Arthroscopic intervention for early symptoms of arthrosis of the knee was a well-established procedure until Moseley cited his study showing no difference in outcomes when compared to “sham” surgery. Now there is no opportunity for reimbursement with arthroscopic debridement unless mechanical internal derangement can be documented. There are, however, several specific lesions of arthrosis which respond well to arthroscopic intervention and are reimbursed by third party payers.

Arthroscopic three compartment microfracture with non-weight bearing and passive motion for eight weeks post- op has significantly relieved symptoms. Second look biopsies have confirmed type II hyaline cartilage and increased joint interval. Proper patient selection is paramount and guidelines will be discussed.

Isolated severe patellofemoral arthrosis with patella subluxation responds to arthroscopic patella lateral facetectomy. Jones has reported significant pain relief up to two years with this excellent option for a difficult patient problem. The technique and results will be presented in detail.

Loss of terminal extension in the arthritic knee can accelerate deterioration and force earlier decision for TKA. Parson's third tubercle is an osteophyte that forms just anterior to the ACL insertion on the tibia and is the frequent cause of extension loss. Arthroscopic resection of the tubercle results in increased extension and diminishes the stress concentration assuring better longevity for the native knee. The diagnostic characteristics, resection techniques and results of the Dallas series will be presented.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_8 | Pages 86 - 86
1 May 2014
Jones R
Full Access

Functional restoration of patella kinematics is an essential component of TKA, whether the patella is replaced or not. This goal is accomplished by a multifactorial approach: establish proper component position and alignment, especially rotation, avoid IR of the femoral and ER of the tibial components, maintain correct joint line position, and achieve symmetrical soft tissue balance

Most modern TKA designs have an anatomic trochlear groove shape to enable midline tracking. Patella implants are better designed as well with three equilateral lugs for fixation and either dome or anatomic shape. The apex of the patella component should be aligned with the apex of the patella raphe which is more medial than lateral. This method leaves an island of exposed lateral patella facet which is managed with the “lateral slat technique” to be described. It is essentially an intraosseous lateral release. The early mobilisation of modern TKA patients demands watertight closure to prevent soft tissue attenuation and late tracking issues.

When confronted with a patient with a laterally dislocated patella, implementation of the “lateral slat technique” should be done at the approach to obtain midline tracking. Such patients require a median parapatellar (MPP) approach and may need distal-lateral vastus medialis advancement (Insall Procedure).

Adherence to the principles iterated herein will produce a happy patient with good patello-femoral kinematics and function.


The Bone & Joint Journal
Vol. 95-B, Issue 12 | Pages 1640 - 1644
1 Dec 2013
Agarwal S Azam A Morgan-Jones R

Bone loss in the proximal tibia and distal femur is frequently encountered in revision knee replacement surgery. The various options for dealing with this depend on the extent of any bone loss. We present our results with the use of cementless metaphyseal metal sleeves in 103 patients (104 knees) with a mean follow-up of 43 months (30 to 65). At final follow-up, sleeves in 102 knees had good osseointegration. Two tibial sleeves were revised for loosening, possibly due to infection.

The average pre-operative Oxford Knee Score was 23 (11 to 36) and this improved to 32 (15 to 46) post-operatively. These early results encourage us to continue with the technique and monitor the outcomes in the long term.

Cite this article: Bone Joint J 2013;95-B:1640–4.


Bone & Joint 360
Vol. 2, Issue 6 | Pages 2 - 8
1 Dec 2013
Jones R Wood D

This article provides an overview of the role of genomics in sarcomas and describes how new methods of analysis and comparative screening have provided the potential to progress understanding and treatment of sarcoma. This article reviews genomic techniques, the evolution of the use of genomics in cancer, the current state of genomic analysis, and also provides an overview of the medical, social and economic implications of recent genomic advances.


The Bone & Joint Journal
Vol. 95-B, Issue 11 | Pages 1441 - 1442
1 Nov 2013
Morgan-Jones R Haddad FS


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 69 - 69
1 May 2013
Jones R
Full Access

Obtaining primary wound healing in Total Joint Arthroplasty (TJA) is essential to a good result. Wound healing problems can occur and the consequences can be devastating to the patient and to the surgeon. Determination of the host healing capacity can be useful in predicting complications. Cierney and Mader classified patients as Type A: no healing compromises and Type B: systemic or local healing compromises factors present. Local factors include traumatic arthritis with multiple previous incisions, extensive scarring, lymphedema, poor vascular perfusion, and excessive local adipose deposition. Systemic compromising factors include diabetes, rheumatic diseases, renal or liver disease, immune compromise, steroids, smoking, and poor nutrition. In high risk situations the surgeon should encourage positive patient choices such as smoking cessation and nutritional supplementation to elevate the total lymphocyte count and total albumin.

Careful planning of incisions, particularly in patients with scarring or multiple previous operations, is productive. Around the knee the vascular viability is better in the medial flap. Thus, use the most lateral previous incision, do minimal undermining, and handle tissue meticulously. We do all potentially complicated TKAs without tourniquet to enhance blood flow and tissue viability. The use of perioperative anticoagulation will increase wound problems.

If wound drainage or healing problems do occur immediate action is required. Deep sepsis can be ruled out with a joint aspiration and cell count, and negative culture and sensitivity. All hematomas should be evacuated and necrosis or dehiscence should be managed by debridement to obtain a live wound. Options available for coverage of complex wound problems include myocutaneous flaps, pedicled skin flaps, and skin grafts. Wet, occlusive dressings and wound VACs encourage epithelisation of chronic wounds.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_22 | Pages 110 - 110
1 May 2013
Jones R
Full Access

There are special circumstances in which revision total knee arthroplasty is not an option. The relative indications for the alternatives to revision TKA are: - Recurrent deep infection - Immunocompromised patient - Extensor mechanism loss - Extensive, non-reconstructable soft tissue loss - High functional demand, young age Remember the three A's as alternatives to revision TKA: arthrodesis, arthroplasty (resection), and amputation. Successful arthrodesis requires elimination of infection, coaptation of bone surfaces and rigid immobilisation. The proper position for arthrodesis is 15 degrees of knee flexion to allow foot clearance. If bone loss is greater than 3 cm fuse the knee in full extension. Avoid hyperextension. Achieve 5 degrees of valgus in correct rotation and use intramedullary instruments from TKA sets for best cuts. External fixation techniques as well as intramedullary internal fixation techniques will be described. Resection arthroplasty is indicated for salvage of an infected total knee when the patient is not a candidate for reimplantation. These patients usually have extensive soft and hard tissue loss. Procedure may be well tolerated and functional. Ancillary support with a long leg drop- lock KAFO increases stability and provides motion. Patients finding resection unacceptable are more likely to accept fusion or amputation; therefore resection may be a staging procedure. Amputation is indicated for failed multiple revisions, intractable or life threatening infection. Also should be indicated when there is a low chance of a successful arthrodesis. Ablate at the lowest level for infection eradication but good maintenance of function. Pedicle muscle flaps can be useful to fill dead spaces. Remember, elderly patients have limited ambulation potential because of high energy requirements of above knee amputation.


The Bone & Joint Journal
Vol. 95-B, Issue 4 | Pages 530 - 535
1 Apr 2013
Roche CP Marczuk Y Wright TW Flurin P Grey S Jones R Routman HD Gilot G Zuckerman JD

This study provides recommendations on the position of the implant in reverse shoulder replacement in order to minimise scapular notching and osteophyte formation. Radiographs from 151 patients who underwent primary reverse shoulder replacement with a single prosthesis were analysed at a mean follow-up of 28.3 months (24 to 44) for notching, osteophytes, the position of the glenoid baseplate, the overhang of the glenosphere, and the prosthesis scapular neck angle (PSNA).

A total of 20 patients (13.2%) had a notch (16 Grade 1 and four Grade 2) and 47 (31.1%) had an osteophyte. In patients without either notching or an osteophyte the baseplate was found to be positioned lower on the glenoid, with greater overhang of the glenosphere and a lower PSNA than those with notching and an osteophyte. Female patients had a higher rate of notching than males (13.3% vs 13.0%) but a lower rate of osteophyte formation (22.9% vs 50.0%), even though the baseplate was positioned significantly lower on the glenoid in females (p = 0.009) and each had a similar mean overhang of the glenosphere.

Based on these findings we make recommendations on the placement of the implant in both male and female patients to avoid notching and osteophyte formation.

Cite this article: Bone Joint J 2013;95-B:530–5.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 65 - 65
1 Jan 2013
Sultan J Chapman G Jones R
Full Access

Background

The knee is the commonest joint to be affected by osteoarthritis, with the medial compartment commonly affected. Knee osteoarthritis is commonly bilateral, yet symptoms may initially present unilaterally. Higher knee adduction moment has been associated with the development and progression of medial compartment knee osteoarthritis.

Objectives

To assess the effect of lateral wedge insoles on the asymptomatic knee of patients with unilateral symptoms of medial compartment knee osteoarthritis.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 86 - 86
1 Sep 2012
Azam A Agarwal S Morgan-Jones R
Full Access

Introduction

This study was undertaken to evaluate the early results of a new implant system - the metaphyseal sleeve - in revision total knee replacement. The femoral and tibial metaphyseal sleeves are a modular option designed to deal with metaphyseal bone loss and achieve cementless fixation over a relatively wide area in the metaphysis.

Methods

Over three years, femoral and/or tibial metaphyseal sleeves were implanted in 104 knees in 103 patients (54 male and 49 female). The clinical notes and radiographs of these patients were reviewed retrospectively. Thirty one patients had revision for infection, 42 for aseptic loosening, and 31 for instability, pain or stiffness. Eighty nine knees were revised as a single stage and 15 were done as two stage procedure. Minimum follow up is 12 months (average 18.5 months).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 241 - 241
1 Sep 2012
Khan T Jackson W Beard D Ahmad M Spacie R Jones R Barker K Price A
Full Access

Background

Despite interest, the current rate of day-case anterior cruciate ligament reconstruction (ACLR) in the UK remains low. Although specialised care pathways with standard operating procedures (SOPs) have been effective in reducing length of stay following some surgical procedures, this has not been previously reported for ACLR. We evaluate the effectiveness of SOPs for establishing day-case ACLR in a specialist unit.

Methods

Fifty patients undergoing ACLR between May and September 2010 were studied prospectively (“study group”). SOPs were designed for pre-operative assessment, anaesthesia, surgical procedure, mobilisation and discharge. We evaluated length of stay, readmission rates, patient satisfaction and compliance to SOPs. A retrospective analysis of 50 patients who underwent ACLR prior to implementation of the day-case pathway was performed (“standard practice group”).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 51 - 51
1 Sep 2012
Edwards G Hall A Morgan-Jones R
Full Access

We describe the results for the management of chronic osteomyelitis in long bones using a new single stage procedure, the Cardiff technique. Fourteen consecutive patients were treated prospectively. The patients had a mean age of 52; all patients had a mean stay in hospital of 5 days with outpatient dressings. All patients had tibial fractures, 2 were infected non unions. The origin of infection was traumatic in 13 cases and haematogenous in 1 case. This one stage procedure or The Cardiff technique, uses techniques described by both Papineau's 3 stage method and Lautenbach's procedure. It involves removal of all avascular and infected tissue via marginal debridement, opening of the medullary cavity proximally and distally, compartmental debridement and copious saline irrigation. The wound is then packed with Jelonet and kaltostat and fresh dressings applied weekly. The wound is left to heal via secondary intention. There is no routine use of antibiotics. Antibiotics were only used when required, i.e. Clinical evidence of cellulitis or infection. 11 patients healed with no further surgery, no skin grafting, no bone grafting and no flap coverage. Mean time to healing was 5 months; both non unions united giving results similar to other accepted techniques. There were 3 residual infections, 2 due to inadequate debridement which required a single further compartmental debridement (Lautenbach method), 1 had an avascular bone edge requiring further local debridement. We feel this procedure confers the following advantages; minimal surgical insult, early discharge, out patient management, good outcomes and most importantly, high patient satisfaction. It also serves as a reminder that simple wounds do well with simple solutions.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 85 - 85
1 Jul 2012
Jain R Majid I Liu A Jones R Johnson D
Full Access

Aim

To determine the tensile forces across the knee extensor mechanism during walking, in simulated conditions of treatment.

Methods

Gait analysis of six normal subjects was performed, with full weight bearing unilateral immobilisation of the knee during walking. Measurements were taken without then with a brace, unlocked then locked at 0°, 0-10°, 0-20° and 0-30° of flexion. Mean and maximum knee flexion angles were measured, followed by calculation of the mean and maximum forces across the extensor mechanism during loading, supporting and propulsion phases of gait.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 56 - 56
1 Jul 2012
Azam A Agarwal S Morgan-Jones R
Full Access

Purpose of the study

This study was undertaken to evaluate the early results of a new implant system - the metaphyseal sleeve - in revision total knee replacement. The femoral and tibial metaphyseal sleeves are a modular option designed to deal with metaphyseal bone loss and achieve cementless fixation over a relatively wide area in the metaphysis.

Methods

Over three years, femoral and/or tibial metaphyseal sleeves were implanted in 104 knees in 103 patients (54 male and 49 female). The clinical notes and radiographs of these patients were reviewed retrospectively. Thirty one patients had revision for infection, 42 for aseptic loosening, and 31 for instability, pain or stiffness. Eighty nine knees were revised as a single stage and 15 were done as two stage procedure. Minimum follow up is 12 months (average 18.5 months).


The Journal of Bone & Joint Surgery British Volume
Vol. 94-B, Issue 7 | Pages 875 - 881
1 Jul 2012
Vanhegan IS Morgan-Jones R Barrett DS Haddad FS

This review summarises the opinions and conclusions reached from a symposium on infected total knee replacement (TKR) held at the British Association of Surgery of the Knee (BASK) annual meeting in 2011. The National Joint Registry for England and Wales reported 5082 revision TKRs in 2010, of which 1157 (23%) were caused by infection. The diagnosis of infection beyond the acute post-operative stage relies on the identification of the causative organism by aspiration and analysis of material obtained at arthroscopy. Ideal treatment then involves a two-stage surgical procedure with extensive debridement and washout, followed by antibiotics. An articulating or non-articulating drug-eluting cement spacer is used prior to implantation of the revision prosthesis, guided by the serum level of inflammatory markers. The use of a single-stage revision is gaining popularity and we would advocate its use in certain patients where the causative organism is known, no sinuses are present, the patient is not immunocompromised, and there is no radiological evidence of component loosening or osteitis.

It is our opinion that single-stage revision produces high-quality reproducible results and will soon achieve the same widespread acceptance as it does in infected hip arthroplasty.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XV | Pages 1 - 1
1 Apr 2012
Carrothers A Gallacher P Gilbert R Kanes G Roberts S Rees D Jones R Hunt A
Full Access

Background

The mechanical disadvantage and detrimental effect to articular cartilage following meniscectomy has been well documented in the literature. Meniscal repair in the avascular (white on white zone) is controversial and would be deemed inappropriate by many.

Methods

Prospective data collection on all meniscal repairs between 1999 and 2008. 423 patients underwent meniscal repair at our unit during this time. We identified 88 patients who underwent a meniscal repair of a non peripheral tear (white on white zone) where there was no co-existent ACL injury or instability. There were 74 males and 14 females with a mean age of 26 years (13-54). There were 50 medial meniscal tears and 38 lateral tears, all in the non peripheral area of the meniscus. The criterion for failure was any reoperation on the same meniscus requiring excision or re fixation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 59 - 59
1 Mar 2012
Gallacher P Gilbert R Carrothers A Kanes G Roberts S Rees D Jones R Hunt A
Full Access

Hypothesis

Avascular meniscal tears can be repaired with good clinical outcomes.

Background

The mechanical disadvantage and detrimental effect to articular cartilage following meniscectomy has been well documented in the literature. Meniscal repair in the avascular (white on white zone) is controversial and would be deemed inappropriate by many.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IV | Pages 57 - 57
1 Mar 2012
Gudena R Mehta J Male K Evans C Jones R
Full Access

Introduction

Review the results of modified Lautenbach procedure (new method) to treat chronic osteomyelitis of the long bones.

Patients and methods

Retrospective analysis of sixty-seven patients with osteomyelitis of the long bones treated over 5-year period with modified Lautenbach procedure. Four patients were excluded from this study, as we were unable to retrieve the case notes. 48 men and 16 women were included and the average age was 33 years. All these patients had prior operative intervention including plating, intramedullary nailing or external fixator. Forty-seven patients had discharging sinuses and deformed leg. We noted the pre-operative inflammatory markers, bacteriology and pain score. We also recorded the duration of the hospital stay, post-operative recovery, deformity and the ability of the patient to resume his prior occupation.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 78 - 78
1 Mar 2012
Jeavons RP Dowen D Jones R O'Brien S
Full Access

Simultaneous bilateral Total Knee Arthroplasty (TKA) has been reported to bring greater patient satisfaction, reduce in-patient stay and recovery, with similar outcomes to single sided or staged TKA, but higher complication rates. No validated selection criteria exist.

We report the results of a single surgeon's experience of simultaneous bilateral TKA, using set guidelines for patient selection.

A prospectively maintained database of all simultaneous bilateral TKA performed between 2002 and 2008 was retrospectively analysed, supplemented by case-note review. Outcome measures included length of stay, blood loss and transfusion rates, complications and functionality and validated outcome scores.

40 patients were included, 23 male and 17 female, all with osteoarthritis. Mean age was male 64.9 and female 61.3 years. Mean ASA grade was 1.8. All fitted selection criteria. Mean tourniquet time was right 79.1 minutes and left 83.6 minutes. Preoperative mean haemoglobin level was 141.8 g/dl and mean post operative level of 87.3 g/dl. 13 patients received purely autologous blood transfusion, 16 patients purely allogenic and 6 patients received both. There was 1 intraoperative complication (Medial collateral injury), 3 minor post operative complications which recovered prior to discharge. There were no thromboembolic events or deaths. Mean follow-up was 32.7 months (range 3-79 months). Mean in-patient stay was 7.5 days. Mean range of movement at most recent follow up was right 1.0 to 119.1 degrees flexion and left 1.0 to 120.8 degrees flexion. Mean Knee Society Scores pre- versus post-operatively were: 67 knee/62 function versus 90 knee/82 function. Oxford Knee Scores, Pre- versus post-operatively were: 43 versus 35 (Scoring 0-60, lowest best outcome).

We demonstrate that with appropriate selection criteria, simultaneous bilateral TKA is safe and successful, giving excellent functional outcomes.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 41 - 41
1 Jan 2011
Caesar B Morgan-Jones R Warren R Wade R Roberts P Richardson J
Full Access

Thirty-five patients were followed prospectively from their referral to the Problem Fracture Service with chronic osteomyelitis of diaphyseal bone between November 1994 and June 1999.

The patients were treated using a closed double-lumen suction irrigation system following reaming and arthroscopic debridement of the intramedullary canal; this is a modified system based on the work of Charles Lautenbach. Results of these procedures were regularly followed up in clinic, and between June and July 2007 the whole cohort was reviewed via postal questionnaire, telephone and case note review.

At a mean follow up of 101 months, 26 were living with no evidence of recurrence, 4 had died of unrelated causes with no evidence of recurrent infection. Four patients had persisting problems with sinus discharge requiring intermittent antibiotic therapy and 1 patient had his limb amputated for recurrent metaplastic change.

These results gave this cohort an 86% clearance of infection, with recurrence in 12%, which is comparable to the Papineau and Belfast techniques with significantly less surgical insult to the patient.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 8 - 8
1 Jan 2011
Rao M Richards O Meyer C Spencer-Jones R
Full Access

To assess the outcome of knee “arthrodesis” using cemented Endo-Model knee fusion nail in failed Total Knee Replacement (TKR) with significant bone loss due to infection. This is a retrospective case study of seven patients with infected TKR and multiple surgeries with significant bone loss.

All patients had antibiotic loaded cement with a temporary K-nail as a first stage procedure to eradicate infection. All seven patients had “arthrodesis” performed using cemented modular Endo-Model Knee Fusion nail (Waldemar Link, Hamburg) by the senior author. Cement was used to hold the stems in the diaphyses and not used around the coupling mechanism. The “arthrodesis” relied entirely on the coupling mechanism which has been shown to have good axial and torsional rigidity by mechanical testing. Outcome was assessed using pre and post Visual Analogue Score (VAS).

Mean age was 72.3 years(62–86). Mean follow up was 39.6 months (7–68). The VAS pain score improved from pre-operative mean score of 7.9 to a postoperative score of 1.5. One patient suffered fracture of femoral cement mantle at 50 months who underwent a technically easy exchange revision. One patient had recurrent infection with distal femoral fracture at 36 months and was revised to distal femoral replacement.

The Endo-Model knee arthrodesis nail restores limb lengths, has good early results in terms of pain relief and provides a stable knee “arthrodesis” in cases where there is significant bone loss and extensor mechanism insufficiency following an infected TKR.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 409 - 410
1 Jul 2010
Kotwal RS Prasad N Morgan-Jones R
Full Access

Purpose of the study: The purpose of this study is to present our initial experience of single stage revision surgery for infected total knee arthroplasty (TKA).

Methods and results: 12 patients underwent single stage revision for infected TKA. The average patient age was 72.5 years and M: F was 2:1. 5 of the 12 patients had frank infection with presence of discharging sinuses pre-operatively. The procedure involved explantation, debridement, subtotal synovectomy, use of high pressure carbon dioxide (Carbojet) and re-implantation using revision prosthesis and antibiotic laden cement. Utmost care was taken to restore the balance and stability of the revised knee. All the patients were given appropriate intravenous and oral antibiotics in the peri-operative period. Oxford knee scores (OKS) were obtained pre-operatively and at the latest follow-up. Patient satisfaction was also assessed.

At the latest follow-up, none of the patients had recurrence of the infection nor did they need any further surgical procedure. There was no radiographic evidence of loosening of the prosthesis. The OKS had improved from a mean of 17 pre-operative to 41 at the latest follow-up. All the patients were extremely satisfied with the outcome.

Conclusion: Knee function and patient satisfaction improved significantly after single stage revision for infected TKA. None of the patients needed further surgery in the short term. Early results are very encouraging and this change in practice may save on costs and patient morbidity associated with the second stage.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 419 - 419
1 Jul 2010
Kotwal RS Fairclough J Morgan-Jones R
Full Access

Purpose of the study: We report an unusual complication of patella tendon rupture that occurred secondary to the use of static cement spacer blocks in a series of three patients undergoing staged revision total knee arthroplasty (TKA) for infection.

Methods and results: 3 male patients developed patella tendon injury secondary to anterior subluxation of static cement spacer blocks used at the first of a two-stage revision procedure for infected TKA. Average patient age was 70 years. The interval between the 1st and the 2nd stages varied between 3.5 to 24 months. At the second stage, it was observed that the patella tendon was completely severed and irreparable in one case, whereas it was partially injured and repairable in the other two cases. In the case with irreparable tendon injury, stable joint reconstruction could not be achieved at the second stage and ultimately resulted in knee arthrodesis. In the other two cases, 2nd stage revision was performed using hinged revision knee components and the tendon injury was repaired and protected with a circlage wire. None of the patients were satisfied with their outcome at the final review.

Conclusion: This is the first report in the literature reporting the complication of patella tendon rupture secondary to the use of static cement spacer blocks in staged revision knee arthroplasty. The injury can either be repairable or irreparable. The functional outcome and satisfaction is not good after the salvage procedures. Therefore, we recommend that these spacer blocks should not be used in revision knee arthroplasty.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 327 - 327
1 May 2010
Richards O Rao M Spencer-jones R
Full Access

Aim: To assess the outcome of knee arthrodesis using cemented Endo-Model knee fusion nail in failed total knee arthroplasty with significant bone loss due to infection.

Methods: A Retrospective case study of seven patients with infected TKR and multiple surgeries and significant bone loss (Type III AORI classification). All patients had antibiotic loaded cement with a temporary K-nail as a first stage procedure to eradicate infection. All seven patients had arthrodesis performed using cemented modular Endo-Model Knee Fusion nail (Waldemar Link, Hamburg) by senior author (RSJ). The arthrodesis relied on the strong coupling mechanism of the nail and not on bony union, providing pain relief while mainting leg length. Outcomes assessed using pre–and post Visual Analogue Score (VAS) and Oxford knee scores.

Results: Mean age 76.8 years (62–85). Mean follow up 23.7 months (3–42). The mean VAS pain score improved from 7.6 (6.5–8.5) pre-operatively to 1.1 (0–3.2) post-operatively. The mean post-operative Oxford score was 30.3 (27–36). One patient required revision for asceptic loosening. All but one of the patients thought that arthrodesis was preferable to amputation post-operatively.

Conclusion: The Endo-Model knee fusion nail has good early results in terms of pain relief and knee arthrodesis where there is significant bone loss and extensor mechanism insufficiency following an infected total knee replacement.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 78 - 78
1 Mar 2009
Gudena R Mehta J Morgan-Jones R
Full Access

Introduction: Sequential staged distraction with fixed rate and rhythm, alternative compression and distraction is well described in the literature to treat non-unions. However we looked the union in established non-unions of tibia using one stage distraction without further manipulation at the fracture site maintaining the stability.

Materials and Methods: 12 patients with established tibial non-unions were referred during the period of 2001–2005. 2 cases were infected non unions. All patients were symptomatic and exhibited deformity at the non-union site. Ten males, two females were in the study group with a mean age of 39.2 years. The location of non-union was distal 1/3 of tibia in 8 cases and 2 cases of proximal and middle 1/3. External fixation was used to acutely distract the fracture (one stage) and tension the soft tissues to attain fracture stability. Infection at the fracture site required further operative debridement. Regular followup with radiographs to assess the union.

Results: Osseous union was achieved in all the cases at an average time period of 17.2 weeks. There was no recurrence of osteomyelitis in the infected cases following secondary debridement. All the patients were pain free and fully mobile without aid at review.

Conclusion: We concluded that acute distraction osteogenesis produces fracture union in selected established cases of non union. This method can be used to obtain impressive gains in the lengths of the long bones. Bone is uniformly produced regardless of the location of the non union. This is more patient compliant, effective and relatively easy to perform.


The Journal of Bone & Joint Surgery British Volume
Vol. 91-B, Issue 2 | Pages 271 - 277
1 Feb 2009
Toms AD Barker RL McClelland D Chua L Spencer-Jones R Kuiper J

The treatment of bony defects of the tibia at the time of revision total knee replacement is controversial. The place of compacted morsellised bone graft is becoming established, particularly in contained defects. It has previously been shown that the initial stability of impaction-grafted trays in the contained defects is equivalent to that of an uncemented primary knee replacement. However, there is little biomechanical evidence on which to base a decision in the treatment of uncontained defects. We undertook a laboratory-based biomechanical study comparing three methods of graft containment in segmental medial tibial defects and compared them with the use of a modular metal augment to bypass the defect.

Using resin models of the proximal tibia with medial defects representing either 46% or 65% of the medial cortical rim, repair of the defect was accomplished using mesh, cement or a novel bag technique, after which impaction bone grafting was used to fill the contained defects and a tibial component was cemented in place. As a control, a cemented tibial component with modular metal augments was used in identical defects. All specimens were submitted to cyclical mechanical loading, during which cyclical and permanent tray displacement were determined.

The results showed satisfactory stability with all the techniques except the bone bag method. Using metal augments gave the highest initial stability, but obviously lacked any potential for bone restoration.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 538 - 539
1 Aug 2008
Kaye M Howells K Skidmore S Warren R Warren P McGeoch C Gregson P Spencer-Jones R Graham N Richardson J Steele N White S
Full Access

Introduction: etiology of late infection after arthroplasty can be difficult to establish. Histology is the gold standard for infection in patients without inflammatory arthritis but diagnosis in inflammatory arthritis depends on culture (Atkins et al). Real-time PCR offers a rapid and direct assessment for staphylococci and enterococci infection but has not been widely assessed.

The aims of this study were

to develop the Roche lightcycler Staphylococcal and Enterococcal PCR kits to facilitate diagnosis of hip and knee prosthetic infections

To analyse results together with bacteriological and histological findings.

Methods: uplicate, multiple tissue samples were taken (with separate sterile instruments) at the 1st stage of revision after informed consent. One set were cultured and results interpreted by the Oxford criteria. The second set were extracted using the Qiagen DNA kit, purified (in-house method) and tested using the Roche lightcycler kits.

Results:53 patients undergoing 2 stage revision for suspected infection were recruited.15 (28.3%) had negative histology and no inflammatory arthritis; 3 with single positive cultures and negative PCR – considered contaminants.

29 patients had non-inflammatory arthritis. 14/18 (77.8%) with positive cultures had staphylococci +/or enterococci isolated and 10 PCR results correlated. The other 11 patients had negative cultures.

9 patients had inflammatory arthritis. Six were culture negative and of the other three, 2 were positive for staphylococci on culture with 1 positive by PCR.

Discussion: Negative staphylococcal PCR correlates with the isolation of staphylococci from only one sample. This agrees with the Oxford criteria that such samples may be considered contaminants. Additional positives detected by staphylococcal PCR alone are rare.

Enterococcal PCR confirmed culture positivity in 2/3 patients. An additional 5 positive PCR’s were obtained from patients’ culture negative for enterococci. It is not clear if these are false positives or more sensitive detection of enterococcal isolation.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 323 - 323
1 Jul 2008
Khan W Jones R Nokes L Johnson D
Full Access

Introduction: In this study the optimal angle of fixation or splintage for partially weight bearing fractures of the patella was determined by a gait analysis measurement system.

Subjects and Methods: A knee brace was applied to eight subjects and locked at 0, 10, 20 and 30 degrees. Measurements were also taken for an unlocked brace and in the absence of a brace. The subjects were instructed on partial weight bearing mobilisation. Three dimensional motion analyses were performed using an infrared 8-camera system. The ground reaction force was recorded by two 3-dimensional force plates embedded in the walkway. Kinematic and kinetic data was collected and the data was transferred to a computer programme for further analysis and the forces acting on the patella were calculated.

Results: The results showed that the forces acting on the patella were directly proportional to the knee flexion angle. The results also showed that the knee flexion angle does not always correspond with the angle set at the knee brace; however they did exhibit a direct relationship.

Conclusion: Our findings show that, for partially weight bearing patella fractures, the optimum form of splintage corresponds with a low knee flexion angle.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 373 - 373
1 Jul 2008
Khan W Jones R Nokes L Johnson D
Full Access

Patella and extensor mechanism injuries are common injuries and are generally managed with some degree of immobilisation and partial weight bearing to facilitate healing. The aim of this project was to determine the type of immobilisation or splintage during partial weight bearing that results in minimal forces acting through the extensor mechanism.

Gait analysis studies were performed on eight healthy male subjects mobilising partially weight bearing. Measurements were taken for six types of immobilisation: locked at 0, 10, 20, 30 degrees and unlocked in an orthotic knee brace, and without a brace. The ground reaction force, knee joint angle and the knee flexion moment were measured using Qualisys Track Manager and Visual 3D Software. The extensor mechanism moment and the extensor mechanism force were calculated using static equilibrium equations and documented data. A one-way analysis of variance statistical test was performed to determine the statistical significance of the differences between the six types of immobilisation.

There was a direct relationship between the knee flex-ion angle and the extensor mechanism force. The extensor mechanism force at 0 degrees of immobilisation was significantly lower than that for 20 and 30 degrees (p< 0.05). The increase in the extensor mechanism moment arm with increasing knee flexion was not suf-ficient to offset the increase in the extensor mechanism force caused by the increase in the knee flexion moment. The results also showed that the knee flexion angle does not always correspond with the angle set at the knee brace; however they did exhibit a direct relationship.

These results have important implications for the management of patients with patella and extensor mechanism injuries. The results suggest that improvements in knee brace design to allow 0 degrees of knee flexion, rather than the 10 degrees as seen in this study, are likely to result in significantly reduced extensor mechanism tensile forces.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 322 - 322
1 May 2006
Malham G Varma D Jones R Williamson OD
Full Access

To investigate the diagnostic properties of magnetic resonance imaging (MRI) scans in detecting surgically verified disruptions of the cervical intervertebral disc and anterior (ALL) and posterior longitudinal (PLL) ligaments.

Data were extracted from the reports of cervical spine MRI scans of patients who subsequently underwent surgical stabilization for presumed instability following disco-ligamentous injuries of the cervical spine. The level and severity of disc, ALL and PLL disruption was compared with surgical findings. Unweighted kappa statistics were used to assess agreement. The sensitivity, specificity, positive (PPV) and negative (NPV) predictive values were calculated after findings where dichotomised into complete rupture, yes/no. Sensitivity analyses were performed to account for missing data.

The MRI and surgical findings were compared on 31 consecutive patients. The kappa values for intervertebral disc disruption, ALL and PLL disruption were 0.22, 0.25 and 0.31 respectively, indicating fair agreement. Sensitivity, specificity, PPV and NPV are shown in Table 1. The false negative rates for diagnosing complete disruption of the disc, ALL and PLL were 0.18, 0.40 and 0.14 respectively.

The ability of cervical MRI scans to detect surgically verified disruptions of the intervertebral disc, ALL and PLL varied depending on the structure examined. In this series, the cervical MRI scan reliably detected disruption of the intervertebral disc disruption and ALL. The false negative rates are of concern and indicate the need for additional investigations to exclude instability in the absence of negative MRI findings.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 50 - 50
1 Mar 2005
DAY M MOHANTY K SPENCER-JONES R
Full Access

Revision hip surgery is becoming increasingly common, 300 procedures being performed in 2001 at our institution. In order to achieve a good outcome bone stock needs to be of good quantity frequently necessitating the use of impaction bone grafting using allograft bone.

Donor bone may frequently take three months before it becomes available for use due to the stringent screening procedure. Donor patients must have a clean bill of health, swabs taken at the time of surgery must obviously demonstrate no growth and blood samples taken at donation and an interval of three months, free from viral infectious diseases. It is thus easy to see the lag from the time of donation to availability and why, with increasing demand, need for allograft bone is rapidly exceeding supply.

We need to look for an alternative supply of human bone allograft.

We have compared the harvest of bone at the time of primary total knee replacement with that of the femoral head by both mass and volume. Sixty consecutive patients undergoing primary hip or knee arthroplasty were included in the study, and the masses and volume of the femoral heads compared with that of the total bone cuts in knee arthroplasty. The type of knee replacement used was documented as was whether the femoral head had had a bone block removed. It was found that the mass of femoral heads was 81g, that of knee cuts 95g this is a statistically significant difference; the volume of femoral heads 66ml and that of knee cuts 75ml.

The volumes of bone available from knee arthroplasty cuts are at least comparable femoral heads obtained using hip replacement and could, perhaps, provide a realistic source of bone allograft.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 209 - 209
1 Mar 2004
Kuiper J Rao C Graham N Gregson P Spencer-Jones R Richardson J
Full Access

Introduction: Impaction grafting has become a popular technique to revise implants. The Norwegian Arthroplasty Registry reports its use for a third of all revisions. Yet, the technique is seen as demanding. A particular challenge is to achieve sufficient mechanical stability of the construction. This work tests two hypotheses: (1) Graft compaction is an important determinant of mechanical stability, and (2) Graft compaction depends on compaction effort and graft properties. Methods: Impaction grafting surgery was simulated in laboratory experiments using artificial bones with realistic elastic properties (Sawbones, Malmö, Sweden). Bone stock was restored with compacted morsellised graft, and the joint reconstructed with a cemented implant. The implant was loaded cyclically and its migration relative to bone measured. In a second study, morsellised bone of various particle sizes and bone densities, with or without added ceramic bone substitutes, was compacted into a cylindrical mould by impaction of a plunger by a dropping weight. Plunger displacement was measured continuously. Results: Initial mechanical stability of the prostheses correlated most strongly with degree of graft compaction achieved. Graft compaction to similar strength was achieved with less energy for morsellised bone with larger particles, higher density, or bone mixed with ceramic substitutes. Conclusion: Initial mechanical stability of impaction-grafted joint reconstructions depends largely on degree of graft compaction achieved by the surgeon. Compaction depends partly on the vigour of impaction, and partly on graft quality. Higher bone density, larger particle size and mixing with ceramic particles all help to facilitate graft compaction, giving a stronger compacted mass with less effort.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 74 - 74
1 Jan 2004
Hart W Rees RJ Metcalfe J Spencer-Jones R
Full Access

Introduction: There are approximately 50000 hip and knee arthroplasties performed in the UK every year. With this increasing number the prevalence of periprosthetic fractures is also rising. These are often challenging problems with increased morbidity and mortality. The use of cortical strut allografts in periprosthetic fractures was first reported in the early 90’s with favourable results.The aim of this study was to assess the radiological outcome of cortical strut allografts used as the treatment for periprosthetic fractures of the femur in patients presenting to our institution.

Patients & Methods: 17 patients with who had received strut allografts as part of their treatment for a periprosthetic fracture of the femur were identified. 13 fractures were around a total hip replacement and 4 around other femoral implants (2 long stemmed TKR’s and 2 fracture fixation devices).

We undertook a radiological evaluation of this technique. We assessed fracture union and strut allograft incorporation using the radiological criteria of Emerson et al. The procedure was deemed a success if the fracture had united, with evidence of graft incorporation with a stable implant. We also undertook a notes review identifying any risk factors and any previous surgery.

Results: Two patients died in the early post-operative period. 15 patients were available for analysis. The average length of radiographic review was 16 months. 11/15 procedures (73%) were deemed a success. All these showed evidence of graft incorporation which was time dependent. There were four failures. In one patient the struts fractured at two months. There were three cases of deep sepsis, this required amputation in one and excision arthroplasty in two.

Conclusion: Cortical strut allografts are a good technique for the management of periprosthetic fractures of the femur. As well as providing initial support they also become incorporated which improves the host bone stock.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 30 - 30
1 Jan 2003
Morgan-Jones R Joneleit M Solis G Cross MJ
Full Access

To document the incidence of intra-articular pathology resulting from delayed Anterior Cruciate Ligament (ACL) reconstruction

A prospective assessment of meniscal and chondral damage found at the time of primary ACL reconstruction, and the relationship of incidence of intra-articular pathology to time since original ACL injury.

We reviewed 1960 patients who had undergone a primary ACL reconstruction. There were 1443 Males and 517 females, with an average age of 28.3 years. The average age at injury was 25.4 years.

1136 patients (58%) had secondary intra-articular pathology, 621 (54.7%) had a medial meniscal tear, 594 (52.4%) had a lateral meniscal tear and 381 (33.5%) had chondral damage. The average time from injury to reconstruction was 2.9 years (34.8 months) Those with secondary intraarticular pathology presented for reconstruction later, average 3.9 years (46.8 months), compared to those without secondary pathology, average 1.5 years (18 months).

The incidence of secondary intra-articular pathology increased with delay between original ACL injury and reconstruction. 41% of those waiting 12 months; 60% of those waiting 3 years; 79% of those waiting 5 years and 88% of those waiting 10 years had secondary intra-articular pathology.

This study confirms the relationship between an unstable ACL deficient knee and the incidence of secondary intra-articular pathology. Furthermore, our study reveals the increasing incidence of meniscal and chondral pathology the greater the delay from injury to ACL reconstruction. To prevent unnecessary secondary intra-articular pathology we recommend ACL reconstruction is performed with minimal delay.


Orthopaedic Proceedings
Vol. 84-B, Issue SUPP_III | Pages 269 - 269
1 Nov 2002
Cross M Roger G Morgan-Jones R Machan S Parish E
Full Access

Introduction: The Motus (Osteo) total knee replacement design is an uncemented, stemless, hydroxyapatite-coated prosthesis designed as a low profile resurfacing implant.

Aim: To review the results after five to eight years of the use of this prosthesis by one surgeon and to discuss the perceived advantages of its design.

Methods: Between 1992 and 1996 the Motus (Osteo) prosthesis was used in 606 primary total knee replacements in 409 patients. The evaluation was undertaken using a clinical knee score based on the Knee Society Score and the Hospital for Special Surgery (HSS) score, which produces a maximum score of 200/200.

Results: The mean age was 69 years (range: 31 to 88 years) with 53% of the patients being female. Osteoarthritis was the underlying pathology in the majority of the cases. The minimum time to follow up was 60 months (mean: 79, range: 60 to 104 months). The mean pre-operative knee score was 98/200 with a range of movement from six degrees to 122 degrees. After five years, the mean knee score was 180/200 with a range of movement from one degree to 113 degrees. To date only two patients have required a revision procedure, both for deep infection. Twenty-six patients have died and six have been lost to follow-up as they are overseas.

Conclusion: At a minimum five-year review, the Motus (Osteo) total knee replacement prosthesis produced excellent functional and clinical results with a low rate of complications.


The Journal of Bone & Joint Surgery British Volume
Vol. 68-B, Issue 1 | Pages 91 - 95
1 Jan 1986
Owen R Turner A Bamforth J Taylor J Jones R

Preliminary costectomy before Harrington instrumentation and fusion for idiopathic scoliosis allows direct excision of the rib prominence and better correction at the second-stage operation. The excised rib fragments are used as grafts, thus avoiding the need for a separate pelvic incision. The management regime and the technique of costectomy are described. The results in 42 children, most suffering from adolescent idiopathic scoliosis and all treated by this method, have been reviewed. Respiratory function in a group of these children has been compared with that of a group treated by Harrington instrumentation alone. Costectomy produced a significantly greater reduction in total lung capacity and peak expiratory flow rate but, providing the preliminary lung function tests were reasonably normal, the cosmetic and psychological effects of costectomy were very rewarding.


The Journal of Bone & Joint Surgery British Volume
Vol. 66-B, Issue 1 | Pages 6 - 7
1 Jan 1984
Jones R

A case of rotatory dislocation of both atlanto-axial joints is presented. A review of the literature reveals two other cases, both in children. This would appear to be the first report in an adult, who survived and made a full recovery.


The Journal of Bone & Joint Surgery British Volume
Vol. 61-B, Issue 1 | Pages 13 - 17
1 Feb 1979
Jones R Khan R Hughes S Dubowitz V


The Journal of Bone & Joint Surgery British Volume
Vol. 49-B, Issue 1 | Pages 1 - 2
1 Feb 1967
Watson-Jones R


The Journal of Bone & Joint Surgery British Volume
Vol. 48-B, Issue 4 | Pages 613 - 613
1 Nov 1966
Watson-Jones R


The Journal of Bone & Joint Surgery British Volume
Vol. 46-B, Issue 4 | Pages 736 - 736
1 Nov 1964
Watson-Jones R




The Journal of Bone & Joint Surgery British Volume
Vol. 41-B, Issue 1 | Pages 3 - 3
1 Feb 1959
Watson-Jones R


The Journal of Bone & Joint Surgery British Volume
Vol. 38-B, Issue 1 | Pages 3 - 3
1 Feb 1956
Watson-Jones R


The Journal of Bone & Joint Surgery British Volume
Vol. 38-B, Issue 1 | Pages 353 - 377
1 Feb 1956
Watson-Jones R Robinson WC

1. This is a simple clinical study of the end-results of arthrodesis of the hip joint in patients followed up and re-examined five to twenty-five years after operation.

2. The study was stimulated by our astonishment at recent reports which suggested that arthrodesis of the hip caused serious operative mortality, a high rate of wound infection, and failure of sound fusion in one of every two cases; and that even when sound fusion was gained there was always pain in the back and usually stiffness of the knee. To say that we were astonished puts it mildly.

3. This review includes 120 patients aged from ten to seventy years, treated for osteoarthritis of the hip joint by intra-articular arthrodesis with the internal fixation of a nail, usually with an iliac graft, and with immobilisation in plaster for not less than four months.

4. Of these 120 patients there was sound fusion of the joint, proved radiographically, in 94 per cent; a mortality of nil; and recovery of free movement of the knee joint to the right angle or far beyond in 91·5 per cent. Almost half of the patients regained normal movement, the heel touching the buttock. Only in eight patients was there less than right-angled flexion.

5. There was no pain in the back—none whatever—in 64 per cent of the patients. In 36 per cent there was some pain or discomfort. One alone said that the low back pain was worse than before the operation. Many others said that pain in the back had been relieved by the operation.

6. It is emphasised that these results were gained only from sound fixation of the joint in the mid-position with neutral rotation, no more abduction than is needed to correct true shortening, and no more flexion of the joint than that with which the patient lies on the table. The limb was immobilised in plaster for at least four months after operation. The stiff knee was mobilised by the patient's own exercise without passive stretching, force or manipulation.

7. Two other groups of patients are considered. There are fourteen treated by fixation of the joint with nail alone, an operation that was never intended to arthrodese the joint and which has long since been abandoned. The other small group is that of patients with old unreduced traumatic dislocation of the hip, a procedure in which the risks of operation are so great and the number of successful results so small as to dissuade us from attempting operative reduction.

8. After successful arthrodesis of the hip joint patients can return to every household activity and every recreation including ski-ing, mountaineering, rock climbing, or whatever else they want.