header advert
Results 81 - 100 of 113
Results per page:
Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 347 - 347
1 Sep 2005
Scarvell J Smith P Refshauge K Galloway H Woods K
Full Access

Introduction and aims: Osteoarthritis (OA) of the knee is a widespread problem, yet there is little known about the kinematics of the osteoarthritic knee, and nothing about the tibio-femoral contact pattern. This study aimed to describe the role of tibio-femoral interface events in articular surface wear and degenerative change.

Method: Fourteen subjects with symptomatic OA in one knee, and no pain or injury in the contralateral knee were recruited. The tibio-femoral contact pattern was recorded for both knees, while performing a supine leg-press from 0 to 90 degrees flexion against a 150N load. Severity of osteoarthritis was measured by Kellgren Lawrence grade, bone mineral density (BMD) using Dual Energy X-ray Absorptiometry close to the subchondral bone, diagnostic MRI, and joint damage recorded at knee arthroplasty. Pain and disability was recorded using a WOMAC questionnaire.

Results: Severity of OA in the knees ranged from grade two to four (mode=4) in the symptomatic knee, and from zero to three (mode=0) in the contralateral knee. Contact in the lateral compartment of the knee was more anterior on the tibial plateau than healthy knees (p≤ 0.01), and this was associated with severity of OA (p≤ 0.01). Contact in the medial compartment was also more anterior on the tibial plateau, and this was associated with severity of OA. Abnormality in tibio-femoral contact patterns was associated with disability reported by the WOMAC score (r= 0.54). There was no significant difference in BMD between the OA and contralateral knees. However, the BMD was correlated with pain and physical function of the WOMAC score, that is, as function decreased, bone density increased in the arthritic compartment (r = 0.49 to 0.63; p≤ 0.01).

Conclusion: Severity of osteoarthritis was associated with loss of rollback normally coupled with flexion, especially in the lateral compartment. Consequently longitudinal rotation was lost. In severe osteoarthritis, ACL integrity did not affect the contact pattern. Kinematic abnormalities may explain loss of range of motion, and patterns of wear in osteoarthritic knees.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 7 | Pages 921 - 927
1 Jul 2005
Glyn-Jones S Gill HS Beard DJ McLardy-Smith P Murray DW

Polished, tapered stems are now widely used for cemented total hip replacement and many such designs have been introduced. However, a change in stem geometry may have a profound influence on stability. Stems with a wide, rectangular proximal section may be more stable than those which are narrower proximally. We examined the influence of proximal geometry on stability by comparing the two-year migration of the Exeter stem with a more recent design, the CPS-Plus, which has a wider shoulder and a more rectangular cross-section. The hypothesis was that these design features would increase rotational stability.

Both stems subsided approximately 1 mm relative to the femur during the first two years after implantation. The Exeter stem was found to rotate into valgus (mean 0.2°, sd 0.42°) and internally rotate (mean 1.28°, sd 0.99°). The CPS-Plus showed no significant valgus rotation (mean 0.2°, sd 0.42°) or internal rotation (mean −0.03°, sd 0.75°). A wider, more rectangular cross-section improves rotational stability and may have a better long-term outcome.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 6 | Pages 863 - 866
1 Jun 2005
Nagarajah K Aslam N McLardy Smith P McNally M

We describe a technique of ‘cross-hip distraction’ to reduce a dislocated hip with subsequent reconstruction of the joint for septic arthritis with extensive femoral osteomyelitis. A 27-year-old woman presented with a dislocated, collapsed femoral head and chronic osteomyelitis of the femur. Examination revealed a leg-length discrepancy of 7 cm and an irritable hip. A staged technique was used with primary clearance of osteomyelitis and secondary reconstruction of the hip. A cross-hip monolateral external fixator was used to establish normal anatomy followed by an arthroplasty. A good functional outcome was achieved. The use of cross-hip distraction avoids soft-tissue and nerve damage and achieved improved abductor function before arthroplasty.


The Journal of Bone & Joint Surgery British Volume
Vol. 87-B, Issue 3 | Pages 320 - 323
1 Mar 2005
Little CP Ruiz AL Harding IJ McLardy-Smith P Gundle R Murray DW Athanasou NA

We present the histological findings of bone retrieved from beneath the femoral components of failed metal-on-metal hip resurfacing arthroplasties. Of a total of 377 patients who underwent resurfacing arthroplasty, 13 required revision; for fracture of the femoral neck in eight, loosening of a component in three and for other reasons in two. None of these cases had shown histological evidence of osteonecrosis in the femoral bone at the time of the initial implantation.

Bone from the remnant of the femoral head showed changes of osteonecrosis in all but one case at revision. In two cases of fracture which occurred within a week of implantation, the changes were compatible with early necrosis of the edge of the fracture. In the remaining six fractures, there were changes of established osteonecrosis. In all but one of the non-fracture cases, patchy osteonecrosis was seen.

We conclude that histological evidence of osteonecrosis is a common finding in failed resurfaced hips. Given that osteonecrosis is extensive in resurfaced femoral heads which fail by fracture, it is likely to play a role in the causation of these fractures.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 40 - 40
1 Mar 2005
Fawzy E Mandellos G Isaac SM Pandit H Gundle R De Steiger R Murray D McLardy-Smith. P
Full Access

Aim: To investigate the functional and radiological outcome of shelf acetabuloplasty in adults with significantly symptomatic acetabular dysplasia, with a minimum of a 5 year follow-up.

Material and Methods: 77 consecutive shelf procedures (68 patients) with an average follow-up of 10.9 years (range: 6–17) were reviewed. The Oxford hip score (OHS) was used for clinical assessment. Centre-edge angle (CEA) and acetabular angle (AA) were measured as indicators of joint containment. The severity of osteoarthiritis was based primarily on the extent of joint space narrowing. Survivorship analyses using conversion to THR as an endpoint were performed. Logrank tests were used to compare the survivorship of the shelf procedure against the variables of age, preoperative osteoarthiritis, pre and postoperative AA, CEA angles.

Results: The average age at time of surgery was 33 years (range: 17–60). At the time of the last follow-up, the mean OHS was 34.6 (maximum score: 48). Mean postoperative CEA was 55 (Pre-operatively: 13 degrees) while mean postoperative AA was 31 (Pre-operatively: 48 degrees). Thirty percent of hips needed THR at an average duration of 7.3 years. The survival in the 45 patients with only slight or no joint space narrowing was 97% (CI, 93%-100%) at 5 years and 75% (CI, 51%-100%) at 10 years. This was significantly higher (p≤= 0.0007) than the survival in the 32 patients with moderate or severe osteoarthiritis, which was 76% (CI, 55%-89%) at 5 years and 22% (CI, 5%-38%) at 10 years. There was no significant relationship between survival and age, pre and postoperative AA, CEA angles (p> 0.05).

Conclusion: Shelf-acetabuloplasty offers symptomatic relief to adults with acetabular dysplasia but overall deteriorates with time. About 50% of the patients do not need THR for over 10 years. Best results with shelf-acetabuloplasty were achieved in patients with slight or no joint narrowing.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 50 - 50
1 Mar 2005
Isaac SM Hauptfleisch J Fawzy E Kellett C Pandit H Gundle R Murray D McLardy-Smith P
Full Access

Purpose of the study: To evaluate the clinical outcome of revision total hip arthroplasty (THA) using the Oxford Hip prosthesis combined with impaction allografting. Methods and results: The Oxford hip is a trimodular prosthesis with a polished tapered metaphyseal section that is free to slide on the stem. The stem is inserted uncemented into the diaphysis, bone graft is impacted proximally, with mesh if necessary, and then the proximal wedge is cemented in.

Between 1999 and 2002, we revised 72 hips in 69 patients using this technique (mean age 65years, 28 to 88). Fifty-six cases had aseptic loosening, 8 had infection (2 stages), 7 had peri-prosthetic fractures and 1 had a broken stem. The mean time to revision was 8.5years (1 to 21). Patients were assessed clinically and with the Oxford Hip Score (OHS) pre- and post-operatively. Fifty-seven patients also had acetabular revision. Four patients required femoral osteotomy to remove the old prosthesis. We used a mean of 1.8 (1 to 4) femoral heads per operation.

Complications included 6 peri-operative femoral fractures diagnosed at operation and fixed successfully, 6 infections, 10 dislocations (2 were recurrent), one deep vein thrombosis, 2 pulmonary embolism and one gastrointestinal haemorrhage. The average blood transfusion was 1.8 units (0 to 9).

The OHS improved from 45 (26 to 58) pre-operatively to 24.3 post-operatively (12 to 43). No hip has been re-revised for aseptic loosening at a mean follow-up of 32.7 months (16 to 51).

Conclusion: Although we accept that this is only a preliminary experience, we believe that the use of the trimodular Oxford stem combined with minimal proximal impaction allografting was found to be a reliable method and a successful way of dealing with revision femoral surgery. The results were comparable with a primary arthroplasty in terms of pain relief and functional results


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 41 - 41
1 Mar 2005
Pearson A Foguet P Little C Murray D McLardy-Smith P Krikler S
Full Access

There is an increasing interest amongst surgeons and demand from patients for hip resurfacing. One concern regarding resurfacing is the incidence of femoral neck fracture post operatively. McMinn and Treacy report an incidence of 0.4% in their series, our finding was of an incidence of over four times as high (1.9%). We looked at our database of hip resurfacings and tried to identify the risk factors for fracture.

We identified 11 fractures and compared these with 22 controls selected by choosing the cases performed by the surgeon immediately before and after the fracture case. We analysed their medical notes and x-rays. Statistical analysis was performed using a package in ™Excel. The implants were either Birmingham Hip (Midland Medical Technologies) or Cormet (Corin) resurfacings.

No statistically significant correlation was found for sex, age or body mass index. We found that fracture was twice as likely in the presence of possible or probable osteopenia. We did not find that fracture was more likely to occur in patients with a previous diagnosis of Perthes, DDH, SUFE and avascular necrosis (AVN).

We found patients with a superior overhang of the femoral component on the neck did not risk fracture, however we could not demonstrate that notching in itself increased the risk of fracture.

There was no correlation with neck-shaft and stem-shaft angle or neck lengthening and offset and subsequent neck fracture.

In 13 bilateral cases there was fracture in 3 (incidence 23%). Apart from one fracture that occurred at 18 weeks post-operatively all the others occurred before eight weeks. Five fractures occurred in patients who subsequently on histological analysis were found to have avascular necrosis.

We conclude that bilateral surgery is probably unwise. That a superior overhang seems to protect against fracture as long as this is not at the expense of creating an inferior notch. Finally, we find AVN in a number of retrieved heads, what is the true incidence of AVN and does the approach adopted cause the avascular process and if so why do we see so few fractures?


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 439 - 439
1 Apr 2004
Rees JL Price AJ Beard DJ McLardy-Smith P Dodd CAF Murray DW
Full Access

Introduction: A new procedure has been recently adopted to implant the Oxford medial unicompartmental arthroplasty (UCA). All cases are now implanted through a short incision without dislocation of the patella. The aims of this study were to assess the one-year results using this new technique and to determine if the outcome is dependent on surgical experience.

Method: The first 104 Oxford UCA’s (Phase 3) implanted by six surgeons under the care of two consultants were reviewed at one year. All operations were performed using the new technique. The average age at surgery was 68 years. All knees were scored pre-operatively and at review with the American Knee Society score. The cohort was divided into two groups; the first ten cases for each surgeon were included in a ‘learning’ group, whilst the remaining cases were included in an ‘experienced’ group.

Results: Overall the average ‘knee score’ improved from 37 points to 94 and the average ‘functional score’ from 50 points to 92. Average maximum flexion improved from 117° to 131°. The ‘knee score’ for the ‘learning’ group was 91 points. This was significantly less (p = 0.008) than the score of the ‘experienced’ group (96 points).

Conclusions: These results are significantly better than the best historical results of the Oxford (UCA), performed through an open approach with dislocation of the patella.

Despite impressive overall results at one year, lower knee scores were associated with a surgeons ‘learning curve’. After this ‘learning curve’, increased surgical experience led to further improvement with 90% achieving an excellent result, 8% a good, 2% a fair and 0% a poor result.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 465 - 466
1 Apr 2004
Smith P Terweil E Cahill J Scarvell J
Full Access

Aim: To determine the cost of medical treatment of infection following total joint replacement (TJR) of the hip or knee. With this information, and obtaining the current costs of antibiotics, antibiotic loaded cement and laminar flow theatres, we aimed to calculate the relative cost- benefit of these prophylactic strategies to prevent infection

Method: Fifty two patients who were admitted to The Canberra Hospital (TCH) for treatment of infection at following total joint arthroplasty between January 1996 and January 2001. A detailed cost analysis of treatment costs following infection was performed. All ward, theatre, prosthesis, investigation, pharmaceutical, allied health and medical costs were collated to produce a total cost of treatment. Current costs of prophylactic antibiotics, antibiotic cement and laminar flow theatres were obtained from suppliers. Costs were calculated for different combinations of prophylactic measures using the rates of deep periprosthetic infection reported through the Swedish Arthroplasty Registry.

Results: There were 41 deep infections and 13 superficial. The average cost for the 54 patients for the in hospital treatment of infection was $41,215. The cost of treating a superficial infection with antibiotics alone averaged $17,663. The average cost of a two stage revision procedure for deep periprosthetic infection was $79,623. Assuming a hospital volume of 150 cases per year, the use of prophylactic intravenous antibiotics, the use of laminar flow and the combined use of antibiotics and laminar flow were significantly cost effective. The addition of antibiotic loaded cement was marginally cost ineffective in combination with either or both of intravenous antibiotics or laminar flow.

Conclusion: The in hospital costs for the treatment of infection after TJR in the Australian setting have been addressed for the first time. Past studies have underestimated the cost of treatment. With this information, we have shown that the combinations of laminar flow and intravenous antibiotic for prophylaxis against infection in TJR are justified on a purely financial cost benefit basis.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 421 - 421
1 Apr 2004
Short A O’Brien S Price A Murray D McLardy-Smith P
Full Access

Polyethylene wear remains an important cause of failure in knee replacements. Retrieval studies, simulators and simple X-ray methods produce wear data that may be inaccurate or unrealistic. We have developed an accurate RSA system for measuring wear in-vivo. Using this system we have found wear rate in a fixed bearing TKR to be about 0.1mm/yr[1]. In this abstract we extend the study to fully congruent mobile bearings.

Four Oxford uni-compartmental knee replacements, with excellent clinical results were studied ten years after implantation. RSA X-rays were taken in double leg stance with the knee in full extension and 15 and 30 degrees flexion. Following RSA calibration, silhouettes of the components on the stereo X-rays were extracted using a Canny edge detector and were matched to silhouettes projected using CAD models to determine the 3D component position. The average minimum thickness of the bearing was determined and was compared with the measured minimum thickness of 14 unused bearings to calculate linear penetration.

The average linear penetration after average 10 years implantation (range 8.5 to 10.25 years) was 0.16 mm (SD 0.13 mm). The average penetration rate was 0.017 mm/year (SD 0.011 mm/year). The maximum linear penetration rate was 0.027 mm/year.

The penetration rate is similar to that obtained in a retrieval study [2]. Compression of the bearing is minimal due to 6sqcm of contact area. This study therefore demonstrates that polyethylene wear on the upper and lower surfaces is minimal in fully congruous mobile bearing knee replacements.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 479 - 480
1 Apr 2004
Scarvell J Smith P Refshauge K Galloway H Woods K
Full Access

Introduction Late degeneration of the ACL injured knee may be in part due to repeat injury, but also due to aberrant kinematics altering the wear pattern at the chondral surface. The aim of this study was to use tibio-femoral contact mapping by MRI to examine kinematic changes due to chronic ACL deficiency.

Methods Twenty-three subjects with a history of chronic ACL deficiency (mean 18 years since injury) performed a closed chain leg press, relaxed and against a 15 kilogram weight. MRI recorded the tibio-femoral contact position at 15° intervals from 0° to 90° of knee flexion. Intra-articular pathology was assessed for all subjects by MRI, and at arthroscopy for 10 subjects.

Results The tibio-femoral contact pattern of the ACL injured knee differed from the healthy contralateral knee (p=0.003). This difference was greatest in the medial compartment, particularly at 0° and 15° of knee flexion (p< 0.01), with the femur two millimetres (mean, SD 3.2 mm) posterior on the tibial plateau. Damage to the chondral surface was seen in the medial compartment in 16 subjects and lateral compartment in 12; medial meniscus damage was present in 16 subjects and lateral meniscus in 15. Chondral surface damage correlated with the difference in the tibio-femoral contact pattern between the healthy and injured knee in the medial compartment of the knee. Joint damage was not related significantly to time since injury, or Cincinnati knee score. Joint damage was related to level of sports participation, but probably indicates that as the joint failed, subjects curtailed their activity.

Conclusions The kinematic consequences of chronic ACL injury may in part be responsible for the pattern of degenerative change, especially in the medial compartment of the knee.

In relation to the conduct of this study, one or more of the authors is in receipt of a research grant from a non-commercial source.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 486 - 486
1 Apr 2004
Aluntas A Choong P Powell G Slavin J Smith P Schlicht S Toner G Ngan S
Full Access

Introduction The aim of this study was to assess the accuracy of CT-guided core needle biopsy of musculo-skeletal tumours.

Methods This is a retrospective study on a series of 127 patients with a musculoskeletal tumours. The biopsies were performed over a four year period from 1998 to 2001. The accuracy of the CT-guided core needle biopsy was determined by comparing the histology of the biopsy with the final histology of the specimen obtained at open biopsy or surgical resection of the tumour. The effective accuracy was determined by the accuracy of the biopsy to diagnose benign versus malignant.

Results CT-guided core needle biopsy in this series has an overall accuracy of 80%. The effective accuracy as determined by a malignant versus benign lesion was 89%. There were 86 malignant tumours with a biopsy accuracy of 81% and there were 41 benign tumours with a biopsy accuracy of 78%. The positive predictive value (PPV) of a malignant tumour is 100% and the PPV of benign tumour 94.9%. The most common site of biopsy was from the femur and thigh, together accounting for 39.4% of the tumours. The most common tumours in this series were liposarcoma (n=12), osteosarcoma (n=11) and giant cell tumour (n=11). There were no reported complications arising from the biopsy.

Conclusions CT-guided core needle biopsy is a safe and effective procedure that is important in the diagnosis and management of musculoskeletal tumours.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 473 - 473
1 Apr 2004
Scarvell J Smith P Refshauge KM Galloway H Woods K
Full Access

Introduction In-vivo study by MRI has contributed to the understanding of knee kinematics for prosthetic design and the impact of knee pathology. The aim of this study was to compare the characteristics of knee motion exhibited by the tibio-femoral contact footprint and centre of the femoral posterior condyles over the tibial plateau during the flexion arc.

Methods Twelve subjects (five males, ages 19 to 42 years) with a unilateral anterior cruciate ligament (ACL) injury performed a supine leg press against a 15 kg load. Sagittal MR images recorded the motion from 0° to 90° flexion of both knees. The tibio-femoral contact points and the position of the posterior condylar centres were measured against the reference of the tibial plateau, at 15° intervals, for both the healthy knee and the ACL injured knee.

Results The tibio-femoral contact points in the healthy knee began anteriorly on the tibial plateau, and progressed posteriorly during the flexion arc. From 0° to 30° the footprints of the medial and lateral compartments are almost parallel. Onward from 30°, the lateral condyle moved further posteriorly than the medial condyle. In the ACL injured knee the footprint was more posterior on the tibial plateau, particularly on the lateral condyle, suggesting the axis of rotation of the knee had shifted medially due to ACL loss. The posterior condylar centres in the healthy knee were positioned over the centre of the tibial plateau in knee extension. The medial condylar centre remained central during the flexion arc, whereas the lateral condylar centre moved back over the tibial plateau. In the ACL injured knee the posterior condylar centres were more posterior than the healthy knees from 0° to 15°, but from 30° to 90° are not significantly different to the healthy knee. The difference in the position of the posterior condylar centres in the ACL injured knee between 0° and 15° indicates the effect of ACL deficiency on the governing axis of the knee in extension, as evidenced clinically by the pivot shift.

Conclusions The tibio-femoral contact patterns describe events at the articular surface whereas posterior condylar centres reflect the movement of the axis of rotation at the knee; two characteristics of knee kinematics. The altered action of the ACL injured knee at the tibio-femoral interface has implications for the development of wear changes in the chronic ACL injured knee.

In relation to the conduct of this study, one or more of the authors is in receipt of a research grant from a non-commercial source.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 492 - 492
1 Apr 2004
Gissane J Kulisiewicz G Smith P
Full Access

Introduction Over 250 patients older than 50 years with fractured neck of femur (NOF) are treated annually at The Canberra Hospital (TCH). Our aim was to improve patient outcomes and reduce length of stay by developing a protocol driven approach to management of patients with NOF fractures, particularly focusing on efficient peri-operative assessment and management of fluid and electrolyte status.

Methods A prospective study of all patients over 50 years, admitted with a diagnosis of fractured neck of femur was carried out at TCH for a 12 month period. Baseline data was collected for a period of six months. We measured clinical factors including; time to theatre, pre-operative fluid resuscitation, length of stay and morbidity. A protocol was then introduced according to agreed best practice dealing with the issues identified in baseline data. Education of medical and nursing staff followed in the major treating areas: Emergency Department and orthopaedics ward. Following this a further six months data was collected to assess the effectiveness of the intervention.

Results Over the 12 month period prior to this study, the length of stay following fractured NOF at TCH was 15.39 days compared to the benchmark of 12.94 days. In the initial six month period 116 patients were admitted to the study. Baseline data demonstrated: average length of stay 12.75 days (from ED to discharge), average time to theatre 35 hours, variable fluid resuscitation for the first 24 hours averaging 1668.4 mls (range: 0 to 4000 mls). The in-hospital death rate in this patient group was 9.5%. In the second six month period, following protocol implementation, improvements were noted to be greatest in fluid resuscitation for the first 24 hours, averaging 3000 mls. Smaller improvements were seen in time to theatre, averaging 34 hours. The mortality rate and length of stay were not significantly different probably due to the higher anaesthetic risk score of the second cohort (p< 0.05).

Conclusions A program of outcomes assessment and evaluation in its first phase improved initial management of these patients and reduced length of stay. Further work is necessary to achieve timely assessment and early surgical intervention. Reducing the in-hospital death rate remains a problematic and complex issue.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 260 - 261
1 Mar 2004
Glyn-Jones S Gill H McLardy-Smith P Murray D
Full Access

Aim: Small amounts of subsidence may be beneficial in stabilising a stem & appears to be a featue of polished tapered stems. Stem rotation (measured as posterior head migration) within the cement mantle, however, is probably a more important mechanism of failure than subsidence. Stems with a wider proximal portion are thought to better resist rotation. The CPS (Endoplus, UK) is such a device; here we compare its’ stability with that of the Exeter (Stryker-Howmedica, UK). Method: 20 patients received the CPS-plus stem & underwent RSA examinations at 3, 6 & 12 months postoperatively. The Exeter 1 year migration data (32 hips) was used as a comparison. Both groups underwent a Hardinge approach & the prosthesis was secured with CMW3G cement. Results: Both stems subsided about 1mm. The CPS showed less medio-lateral & A-P movement of the proximal stem than the Exeter over 1 year, as shown below: 1 Year Mean Migration ± SEM (mm) Discussion: The CPS internally rotates less than the Exeter, as demonstrated by the smaller amount of posterior head migration. It has a lateral flare of the shoulder; making its’ cross-section wider than the Exeter’s, this probably produces a greater resistance to rotation. The CPS also undergoes less medio-lateral proximal stem migration. Its’ lateral shoulder flare is probably responsible for this axial subsidence, as it prevents the shoulder from moving laterally whilst subsiding onto the calcar.

Increasing the width of the proximal section of a polished tapered stem enhances its rotational stability.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 366 - 366
1 Mar 2004
Harding I Little C Ruiz A Murray D McLardy-Smith P Athanasou N
Full Access

Aims: To determine the pathological changes in the femur following resurfacing hip arthroplasty and identify possible causes of early failure. Methods: Bone samples from 8 femoral heads at several levels were examined histologically following removal of cemented femoral head surface replacement following aseptic early failure: 4 neck fractures (no history of fall), 3 persistent severe pain and 1 cup loosening. Intra-operatively no obvious macroscopic causes of failure (including notching the neck) were noted. In all patients, the initial diagnosis had been osteoarthritis. None had known risk factors for osteonecrosis. Results: In the patients who had recent fracture, the bony changes were suggestive of relatively longstanding osteonecrosis with degenerative, necrotic and þbrotic changes in the bone marrow and loss of osteocyte nuclei in the trabeculae. There was appositional new bone formation at the surface of the necrotic bone trabeculae. The changes were consistent with osteonecrosis of more than 2 weeks duration and probably preceded the fracture in all cases. In the patients who underwent revision for non-fracture, some osteonecrosis was seen, but this was a lot less than when a fracture had occurred. Conclusion: Osteonecrosis of the femoral head is seen following resurfacing hip arthroplasty and may be a predisposing factor in patients who subsequently fracture.


The Journal of Bone & Joint Surgery British Volume
Vol. 86-B, Issue 2 | Pages 172 - 176
1 Mar 2004
Glyn-Jones S Gill HS McLardy-Smith P Murray DW

The Birmingham hip resurfacing (BHR) arthroplasty is a metal-on-metal prosthesis for which no medium- or long-term results have been published. Despite this, it is increasing in popularity as an alternative to stemmed prostheses for younger patients. Since the fixation of the socket is conventional, the major concern is long-term failure of the femoral component. This can be predicted by the use of roentgen stereophotogrammetric analysis (RSA). We have therefore undertaken such a study of the BHR femoral component over a period of two years.

Twenty patients (22 hips) underwent a standard BHR procedure. Migration of the femoral component was measured by RSA at intervals of three, six, 12 and 24 months. At 24 months the total three-dimensional migration of the head was 0.2 mm. This was not statistically significant. Previous studies have shown that implants which loosen quickly have rapid early migration. Our results therefore suggest that the BHR femoral component is an inherently stable device which is likely to perform well in the long term.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 167 - 167
1 Feb 2004
Fawzy E Mandellos G Murray D Gundle R De Steiger R McLardy-Smith P
Full Access

Introduction: Persistent acetabular dysplasia is a recognized cause of premature hip arthritis. Treatment options include joint preservation (acetabuloplasty/osteotomy) or salvage procedures (THR). Presence of a deficient acetabulum and an elevated acetabular centre make THR technically demanding with uncertain outcome. Shelf ace-tabuloplasty is a viable option, however, most reports in the literature focus on results in children and adolescents.

Aim: To investigate the functional and radiological outcome of shelf acetabuloplasty in adults with significantly symptomatic acetabular dysplasia.

Material and Methods: 77 consecutive shelf procedures (68 patients) with an average follow-up of 10.9 years (range: 6–17) were reviewed. The Oxford hip score (OHS) was used for clinical assessment. Centre-edge angle (CEA) and acetabular angle (AA) were measured as indicators of joint containment.

Results: The average age at surgery was 33 years (range: 17–60). At the time of last follow-up; the mean OHS was 34 (maximum score: 48). Mean postoperative CEA was 59 (Pre-operatively: 16.2 degrees) while mean postoperative AA was 31 (Pre-operatively: 47.5 degrees). Thirty percent of hips needed THR at an average duration of 7.3 years. Pre-operative arthritis was present in 32 hips out of which 17 (53 percent) needed THR. Out of the remaining 45 hips, only 6 (13 percent) needed THR. No correlation was found between the acetabular indices and the outcome.

Conclusion: Shelf-acetabuloplasty offers symptomatic relief to adults with acetabular dysplasia and can delay the need for THR for over 10 years. Best results with shelf-acetabuloplasty were achieved in patients without preoperative arthritis.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 19 - 19
1 Jan 2004
Glyn-Jones S Gill H McLardy-Smith P Murray D
Full Access

The relative motion between a prosthesis, the cement mantle and its’ host bone during weight bearing is not well understood. Using Radiostereophotogrammetric Analysis (RSA), we examined the dynamically inducible micromotion that exists at these interfaces when an increased load is placed through the prosthesis.

Dynamically inducible micromotion was measured in the femoral components of 21 subjects undergoing total hip replacement with polished Exeter stems. Two standing RSA studies were performed, at 3 and 12 months postoperatively. Firstly in double-leg stance, and secondly fully weight bearing through the operated hip.

Subjects had no signs of clinical or radiological signs of loosening at 1 year. Significant micromotion was detected at the prosthesis-cement interface at 3 months.

Similar patterns of micromotion were observed at 12 months. The prosthesis appeared to bend during single-leg stance weight bearing, however this accounted for less than half of the total observed movement.

Conventional RSA studies were conducted at 3 months, 6 months and 1 year to confirm that the implants showed normal migration patterns.

This study demonstrates that movement exists between the prosthesis and bone during cyclical weight bearing. This dynamically inducible micromotion probably occurs at the prosthesis-cement interface. It could account for the wear that is observed on the surface of retrieved secure prostheses. This may be a mechanism by which failure eventually occurs.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 16 - 16
1 Jan 2004
Price A Short A Kellett C Rees J Pandit H Dodd C McLardy-Smith P Gundle R Murray D
Full Access

The aim of the study was to measure in-vivo the 10-year linear and volumetric polyethylene wear of a fully congruent mobile bearing unicompartmental knee arthroplasty (OUKA).

We studied six OUKA’s that had all been implanted 10 years previously. Each patient was examined in even double leg stance at a range of knee flexion angles, in a calibration cage. A stereo pair of X-ray films was acquired for each patient at 0°, 15° and 30° of flexion. The films were analysed using an RSA style calibration and a CAD model silhouette-fitting technique. The position and orientation of each femoral and tibial component was found relative to each other and the bearing position inferred. Penetration of the femoral component into the original volume of the bearing was our estimate of linear wear. The volumetric wear is calculated from the measured linear wear and the known surface area of the bearing. In addition eight control patients were examined less than 3 weeks post-operation where no wear would be expected.and 30We studied seven OUKA’s that had all been implanted at least 10 years previously. A stereo pair of X-ray films was acquired for each patient at 0 Results: The control group showed no measured wear. The seven OUKA’s had an average maximum depth of linear penetration of 0.40 mm at a mean follow-up of 10.9 years. The linear wear rate was 0.033 mm/year. The volumetric material loss was 79.8 mm3. If a steady gradual material loss is assumed, 8 mm3 of UHMWPE was lost per year.

Polyethylene particulate wear debris continues to be implicated in the aetiology of component loosening and implant failure knee following arthroplasty. The OUKA employs a spherical femoral component and a fully congruous meniscal bearing to increase contact area and theoretically reduce the potential for polyethylene wear. The results from this in-vivo study confirm that the device has low 10-year linear and volumetric wear in clinical practice. This may protect the device from component loosening in the long term.