100% of medial compartments showed full thickness anteromedial loss with preservation of the posteromedial cartilage. When present, the meniscus was extruded in 96% of cases. 90% of lateral compartments were normal and none had full thickness cartilage loss. However 10% showed high signal in the tibial plateau. There was a highly reproducible pattern of osteophyte formation; 94% posteromedial and posterolateral aspect of medial femoral condyle; 90% medial tibial; 80% medial femoral and 84% lateral intercondylar notch.
Kinematic data from in-vivo fluoroscopy measurements during a step-up activity was used to determine the relative tibial-femoral position as a function of knee flexion angle for each model. Medial and lateral force distribution was adapted from loads measured in-vivo with an instrumented implant during a step-up activity. The affect that varying the bearing thickness has on the stresses in the bearing was investigated. In addition, varus-valgus mal-alignment was investigated by rotating the femoral component through 10 degrees.
Twenty patients underwent simultaneous bilateral medial unicompartmental knee arthroplasty. Pre-operative hip-knee-ankle alignment and valgus stress radiographs were used to plan the desired post-operative alignment of the limb in accordance with established principles for unicompartmental arthroplasty. In each patient the planned alignment was the same for both knees. Overall, the mean planned post-operative alignment was to 2.3° of varus (0° to 5°). The side and starting order of surgery were randomised, using conventional instrumentation for one knee and computer-assisted surgery for the opposite side. The mean variation between the pre-operative plan and the achieved correction in the navigated and the non-navigated limb was 0.9° ( Assessment of lower limb alignment in the non-navigated group revealed that 12 (60%) were within ± 2° of the pre-operative plan, compared to 17 (87%) of the navigated cases. Computer-assisted surgery significantly improves the post-operative alignment of medial unicompartmental knee arthroplasty compared to conventional techniques in patients undergoing bilateral simultaneous arthroplasty. Improved alignment after arthroplasty is associated with better function and increased longevity.
We carried out a prospective randomised study to evaluate the blood loss in 60 patients having a total knee arthroplasty and divided randomly into two equal groups, one having a computer-assisted procedure and the other a standard operation. The surgery was carried out by a single surgeon at one institution using a uniform approach. The only variable in the groups was the use of intramedullary femoral and tibial alignment jigs in the standard group and single tracker pins of the imageless navigation system in the tibia and femur in the navigated group. The mean drainage of blood was 1351 ml (715 to 2890; 95% confidence interval (CI) 1183 to 1518) in the computer-aided group and 1747 ml (1100 to 3030; CI 1581 to 1912) in the conventional group. This difference was statistically significant (p = 0.001). The mean calculated loss of haemoglobin was 36 g/dl in the navigated group There was a highly significant reduction in blood drainage and the calculated Hb loss between the computer-assisted and the conventional techniques. This allows the ordering of less blood before the operation, reduces risks at transfusion and gives financial saving. Computer-assisted surgery may also be useful for patients in whom blood products are not acceptable.
We reviewed 230 patients an average of 34 months after they had undergone partial or total meniscectomy by surgeons of different experience in a busy unit. Open and arthroscopic meniscectomies were compared. Arthroscopic partial meniscectomy resulted in a significant reduction of inpatient stay and earlier return to work and sport. Analysis of the type of meniscal damage showed that arthroscopic removal of "bucket handles" achieved better results than open techniques. Comparatively poor results were found for lateral meniscectomy.
A retrospective survey has been made of forty children with spinal tumours. Difficulties in establishing the correct diagnosis are mentioned and the value of radiological and cerebrospinal fluid investigations discussed. The major orthopaedic disabilities are spinal deformity or instability, and paraplegia. The main factor in the development of the former is the site of laminectomy: the higher the level the greater is the likelihood of deformity or instability developing. Measures to prevent this distressing complication are discussed. The role of the orthopaedic surgeon in the management of these children is emphasised.