Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 68 - 68
1 Mar 2006
Lamberton T Charity J Kenny P Timperley A Gie G
Full Access

Introduction: Impaction bone grafting in conjunction with a cemented polished double-taper stem as a technique for revision of the femoral component was introduced in 1987 at our institution.

Methods: As at January 2000, 540 cases in 487 patients had been performed by multiple surgeons. All procedures have been studied prospectively, and there are no patients lost to follow-up. We present the survivorship and outcome data for these patients.

Results: Survivorship at 15 years is 90.6 percent (95 percent confidence interval: 88–93 percent).

406 hips in 365 patients remain under active follow up, with 122 patients (134 hips) deceased.

Averaged clinical scores taken pre-operatively, 2 years post-operatively, and at latest follow-up show marked and sustained improvement: Charnley Pain 2.7, 5.5, 5.3; Charnley Function 2.1, 4.1, 3.6; Charnley Range of Motion 4.0, 5.4, 5.3; Harris Pain 19, 38, 36; Harris Function 18, 32, 28; and Oxford Hip Score 41, 22, 25.

There have been 45 failures (8.3 percent) at an average 7.6 year follow up (range 2.6 – 15.3 years). Technical error contributed to 13 of the 24 non-infective complications, but with improved technique plus the addition of long stemmed impaction grafting, there have been no technical errors since 1996.

Conclusion: Our results show that revision of the femoral component with impaction bone grafting is a reliable and durable technique with an acceptably low complication rate with excellent survivorship at 15 years.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 361 - 361
1 Sep 2005
Charity J Gie G Hoe F Timperley A Ling R
Full Access

Introduction and Aims: To study the survivorship and subsidence patterns of the first 433 Exeter polished, totally collarless, double tapered, cemented stems that were inserted between November 1970 and the end of 1975 by 16 different surgeons (13 of them in the training grades) utilising first generation cementing techniques.

Method: A survivorship study up to the 33rd year of follow-up, using the contingency table method, was performed for all 433 hips, the end-point being revision for aseptic stem loosening (including also a ‘worst case’ scenario). Stem subsidence in relation to the cement and the bone was measured in all survivors by a single observer on digitised films (magnified 200%) using the Orthochart™ software. Repeated measurements allowed the analysis of intra-observer errors. Stem subsidence, the grade of cementing, ‘calcar’ resorption, visible cement fractures, focal lysis and radiolucent lines at the interfaces were assessed.

Results: Of the 433 hips, 21 were revisions of previously failed hips. 21.7% of patients have had a re-operation of some sort, including 3.69% for stem fracture, 3.46% for neck fracture (all from a group of 95 stems with excessively machined necks), 9% for aseptic cup loosening, 3.46% for aseptic stem loosening, 1.84% for infection and 0.23% for recurrent dislocation). For the overall series, with revision for aseptic stem loosening as the end-point, the survivorship is 91.42% (95%CI: 70.82 to 100%). When all cases lost to follow-up (28 hips) are regarded as failures, survivorship is 82.9% (95%CI: 58.37 to 100%).

The average age at operation of the survivors was 57.6 years. No significant radiological subsidence between the cement and bone was found. Mean subsidence between the stem and the cement was 2.15mm, most occurring in the first five years and in all but one being less than four. The maximum was 18mm (grade D cementing). Cementing grades were B in 65%, C in 27%, D in 8%. Resorption of the neck (13%) was associated with excessive socket wear or cement left over the cut surface of the neck (the ‘pseudocollar’). Visible cement fractures were found in 14%, none associated with focal lysis, which was seen in 11%.

Conclusion: Although 21.7% of patients in this series of the first 433 Exeter hips to be inserted in Exeter needed a re-operation of some sort, the stem rarely required surgery for aseptic loosening and was associated with benign long-term x-ray appearances in spite of 1st generation cementing.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 357 - 357
1 Sep 2005
Lamberton T Charity J Kenny P Timperley A Gie G
Full Access

Introduction and Aims: Impaction bone grafting in conjunction with a cemented polished double-taper stem as a technique for revision of the femoral component was introduced in 1987 at our institution. The aim of this study is to report on the outcome, survivorship, complications and radiological analysis of the first consecutive 540 cases performed in Exeter.

Method: As at January 2000, 540 cases in 487 patients had been performed by multiple surgeons. All procedures have been studied prospectively, and there are no patients lost to follow-up. We present the survivorship and outcome data for these patients.

Radiological analysis of the pre-operative, immediate post-operative and most recent follow-up radiographs was also performed. This included evaluation of the cement mantle and impacted allograft, stem subsidence within the cement mantle, presence of cortical healing and graft trabeculation on the follow-up radiographs, as well as appearance of radiolucencies and graft resorption.

Results: Survivorship at 15 years is 90.6 percent (95 percent confidence interval: 88–93 percent). Four hundred and six hips in 365 patients remain under active follow-up, with 122 patients (134 hips) deceased. Averaged clinical scores taken pre-operatively, two years post-operatively, and at latest follow-up, show marked and sustained improvement: Charnley Pain 2.7, 5.5, 5.3; Charnley Function 2.1, 4.1, 3.6; Charnley Range of Motion 4.0, 5.4, 5.3; Harris Pain 19, 38, 36; Harris Function 18, 32, 28; and Oxford Hip Score 41, 22, 25.

There have been 45 failures (8.3 percent) at an average 7.6-year follow-up (range 2.6–15.3 years). Technical error contributed to 13 of the 24 non-infective complications, but with improved technique plus the addition of long stemmed impaction grafting, there have been no technical errors since 1996.

Conclusion: Our results show that revision of the femoral component with impaction bone grafting is a reliable and durable technique with an acceptably low complication rate with excellent survivorship at 15 years.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_I | Pages 28 - 29
1 Mar 2005
Lamberton T Charity J Kenny P Timperley A Gie G
Full Access

Impaction bone grafting in conjunction with a cemented polished double-taper stem as a technique for revision of the femoral component was introduced in 1987 at our institution.

As at January 2000, 540 cases in 487 patients had been performed by multiple surgeons. All procedures have been studied prospectively, and there are no patients lost to follow-up. We present the survivorship and outcome data for these patients.

Survivorship at 15 years is 90.6 percent (95 percent confidence interval:88–93 percent). Four hundred and six hips in 365 patients remain under active follow up, with 122 patients (134 hips) deceased.

Averaged clinical scores taken preoperatively, 2 years postoperatively and at latest follow up showed marked and sustained improvement: Charnley Pain 2.7, 5.5, 5.3; Charnley Function 2.1, 4.1, 3.6; Charnley Range of Motion 4.0, 5.4, 5.3; Harris Pain 19, 38, 36; Harris Function 18, 32, 28; and Oxford Hip Score 41, 22, 25. There have been 45 failures (8.3 percent) at an average 7.6 year follow up (range 2.6–15.3 years). Technical error contributed to 13 of the 24 non-infective complications, but with improved technique plus the addition of long stemmed impaction grafting, there have been no technical errors since 1996.

Our results show that revision of the femoral component with impaction bone grafting is a reliable and durable technique with an acceptably low complication rate with excellent survivorship at 15 years.