header advert
Results 21 - 40 of 58
Results per page:
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 4 - 4
1 Jun 2017
Davda K Wright S Heidari N Calder P Goodier W
Full Access

Introduction

The management of a significant bone defect following excision of a diaphyseal atrophic femoral non-union remains a challenge. Traditional bone transport techniques require prolonged use of an external fixator with associated complications. We present our clinical outcomes using a combined technique of acute femoral shortening, stabilised with a deliberately long retrograde intramedullary nail, accompanied by bifocal osteotomy compression and distraction osteogenesis to restore segment length utilising a temporary monolateral fixator.

Method

9 patients underwent the ‘rail and nail’ technique for the management of femoral non-union. Distraction osteogenesis was commenced on the 6th post-operative day. Proximal locking of the nail and removal of the external fixator was performed approximately one month after length had been restored. Full weight bearing and joint rehabilitation was encouraged throughout. Consolidation was defined by the appearance of 3 from 4 cortices of regenerate on radiographs.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 9 - 9
1 Jun 2017
Wright J Calder P
Full Access

Background

Severe infantile Blount's disease can result in a multiplanar deformity of the proximal tibia with both intra-articular and metaphyseal components. Correction can represent a significant surgical challenge. We describe our results using the Taylor spatial frame for acute tibial hemiplateau elevation combined with gradual metaphyseal correction in patients with severe infantile blounts with an associated physeal bony bar.

Methods

Eight patients (10 knees) underwent tibial hemiplateau elevation and metaphyseal correction with use of the Taylor Spatial Frame between 2012–2016. We undertook a retrospective case note and radiographic review of all patients to assess clinical and radiographic outcomes. Mean age at the time of surgery of was 11.7 years and mean length of follow up was 16.8 months.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_11 | Pages 7 - 7
1 Jun 2017
Calder P Shaw S Roberts A Tennant S Sedki I Hanspal R Eastwood D
Full Access

Purpose

This study compares outcomes in patients with complete congenital fibula absence, associated with severe lower limb deformity, treated with an amputation protocol to those using an extension prosthesis.

Method

32 patients were identified. 9 patients (2M: 7F, median age at presentation of 22 yrs) utilized an extension prosthesis. 23 patients (16M: 7F, median age at presentation of 10 months) underwent 25 amputations during childhood: only two underwent tibial kyphus correction to facilitate prosthetic wear.

Mobility was assessed using the SIGAM and K scores. Quality of life was assessed using the PedsQL inventory questionnaire; pain by a verbal severity score. Patients undergoing amputation were further subdivided by age, below and above 2 yrs at the time of surgery.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_13 | Pages 8 - 8
1 Jun 2017
Calder P Shaw S Roberts A Tennant S Sedki I Hanspal R Eastwood D
Full Access

Purpose

This study compares outcomes in patients with complete congenital fibula absence treated with an amputation protocol to those using an extension prosthesis.

Introduction

Complete fibula absence presents with significant lower limb deformity. Parental counselling regarding management is paramount in achieving the optimum functional outcome. Amputation offers a single surgical event with minimal complications and potential excellent functional outcome.


The Bone & Joint Journal
Vol. 98-B, Issue 11 | Pages 1548 - 1553
1 Nov 2016
Tennant SJ Eastwood DM Calder P Hashemi-Nejad A Catterall A

Aims

Our aim was to assess the effectiveness of a protocol involving a standardised closed reduction for the treatment of children with developmental dysplasia of the hip (DDH) in maintaining reduction and to report the mid-term results.

Methods

A total of 133 hips in 120 children aged less than two years who underwent closed reduction, with a minimum follow-up of five years or until subsequent surgery, were included in the study. The protocol defines the criteria for an acceptable reduction and the indications for a concomitant soft-tissue release. All children were immobilised in a short- leg cast for three months. Arthrograms were undertaken at the time of closed reduction and six weeks later. Follow-up radiographs were taken at six months and one, two and five years later and at the latest follow-up. The Tönnis grade, acetabular index, Severin grade and signs of osteonecrosis were recorded.


The Bone & Joint Journal
Vol. 98-B, Issue 10 | Pages 1382 - 1388
1 Oct 2016
Laubscher M Mitchell C Timms A Goodier D Calder P

Aims

Patients undergoing femoral lengthening by external fixation tolerate treatment less well when compared to tibial lengthening. Lengthening of the femur with an intramedullary device may have advantages.

Patients and Methods

We reviewed all cases of simple femoral lengthening performed at our unit from 2009 to 2014. Cases of nonunions, concurrent deformities, congenital limb deficiencies and lengthening with an unstable hip were excluded, leaving 33 cases (in 22 patients; 11 patients had bilateral procedures) for review. Healing index, implant tolerance and complications were compared.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 5 - 5
1 May 2015
Peek A Timms A Wartemberg G Chin K Calder P Goodier D
Full Access

Several low energy osteotomy techniques are described in the literature but there is limited evidence comparing healing indices. We present a retrospective review of two techniques to evaluate an optimum method.

Method:

Two cohorts of patients underwent osteotomy of the tibia using a Gigli saw (n=15) or DeBastiani corticotomy (n=12) technique. Indications for surgery included limb lengthening and bone transport for defect reconstruction with a minimal distraction of 2 cm. The patient radiographs were anonymised and the regenerate assessed by the two senior authors who were blinded to the osteotomy type. Bone quality was recorded along the anterior, posterior, medial and lateral cortices, graded 1–5 from absent to full consolidation over time in frame. The time to 3 cortices healed/regenerate length was calculated. The time to consolidation of the anterior, posterior, medial and lateral cortices were compared.

Results:

The mean 3 cortices index in the Gigli group was 2.0 months/cm and in the DeBastiani group 1.8 months/cm, This was not a significant difference. In both groups anterior bone formation was slower, and in 50% and 33% of the Gigli and DeBastiani groups respectively the anterior cortex did not fully heal by the time of frame removal.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 13 - 13
1 May 2015
Mitchell C Timms A Laubscher M Goodier D Calder P
Full Access

Background:

The Exogen Ultrasound Device is licensed for fracture non-union under NICE guideline MTG-12. Reimbursement is offered if there is no fracture union after 250 days of treatment as per manufacturer guidelines. Quoted healing rates vary between 62% and 100%: we compare our results to these.

Method:

A retrospective audit of all patients who received Exogen for long bone non-union was undertaken. The indication, duration of treatment, fracture outcome and compliance with the recommended treatment pathway were recorded.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 15 - 15
1 May 2015
Laubscher M El-Tawil S Ibrahim I Mitchell C Smitham P Chen P Goodier D Gorjon J Richards R Taylor S Calder P
Full Access

Background:

Little is known about the forces carried by the Taylor Spatial Frame (TSF) hexapod fixator. Our aim was to measure the TSF resultant force and how this changed during the consolidation phase.

Method:

Five patients undergoing correction of tibial deformities were recruited. Measurements were taken at 2, 4, 8 and 12 weeks post-correction during various activities. Instrumented struts incorporating strain gauges measuring axial force were temporarily used each time. Strut forces and lengths were used to determine frame kinetics. The resultant axial fixator forces and moments were calculated relative to sitting. Ground reaction forces (GRF) were measured using the treadmill force plates.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 1 - 1
1 May 2015
Laubscher M Mitchell C Timms A Goodier D Calder P
Full Access

Background:

External fixators are not as well tolerated around the femur when compared to the tibia. Lengthening with an intramedullary device is therefore attractive.

Method:

We reviewed all cases of femoral lengthening performed at our unit from 2007 to 2014. Cases of non-unions, concurrent deformities, congenital limb deficiencies and lengthening with an unstable hip were excluded. This left 33 cases for review. Healing index, implant tolerance and complications were compared.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_5 | Pages 4 - 4
1 May 2015
Laubscher M Mitchell C Timms A Goodier D Calder P
Full Access

Background:

Leg length discrepancy related to absence of the femoral head with proximal migration of the femur presents a treatment dilemma. Late sequelae of neonatal hip sepsis and chronic hip dislocation due to developmental dysplasia are the most common causes. Traditional teaching dictates that the hip is stabilised prior to limb lengthening. Reconstructive options alter the shape of the proximal femur which complicates future surgery.

Methods:

We retrospectively reviewed 3 cases of femoral lengthening with an ‘unstable’ hip without prior stabilization. The aetiology was neonatal hip sepsis in 2 cases and chronic hip dislocation due to developmental dysplasia in 1 case. Lengthening was performed with the use of a retrograde Precice lengthening nail.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_10 | Pages 22 - 22
1 Jul 2014
Ibrahim I Timms A Chasseaud M Goodier D Calder P
Full Access

Pin site care in external fixation remains a major challenge. The ideal dressing regime still remains controversial as does the type of dressing. We present an audit following the use of a sponge compression dressing in comparison to previously used sterile gauze.

All pins and wires were inserted using a standardised technique. Dressings were applied during surgery to prevent haematoma formation.

The new sponge dressing was applied to the wire or half-pin sites and compressed to the skin by either pierced tubing over the wire or clips at the end of the procedure. Dressings were changed weekly unless the pin sites were discharging serous fluid or frankly infected, when they were changed as required.

The pin sites were evaluated for evidence of infection or irritation using the good, bad or ugly grading system. Each evaluation was performed by two of the authors on two separate occasions to assess the inter- and intra-observer error. The results were compared to those previously reported using sterile gauze as the pin site dressing.

1035 pin sites were assessed. 985 pin sites were graded as “good” (95.2%), 49 “bad” (4.7%) and 1 “ugly”. The kappa values demonstrated excellent inter- and intra-observer correlation, 0.892 and 0.905 respectively.

The previous study using gauze reported 600 pin sites with 514 graded “good” (85.7%), 80 “bad” (13.3%) and 6 “ugly” (1%).

The use of compression sponge dressing appears to reduce the rate of pin site irritation and infection. Further anecdotal evidence by patients who have undergone surgical treatment using both techniques demonstrated a preference for the sponge dressings due to ease of dressing change and general comfort once applied. We therefore would recommend this type of dressing in the use of external fixation.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_23 | Pages 13 - 13
1 May 2013
Barker A Smitham P Scarsbrook C Calder P
Full Access

A statement of the purposes of the study

This study examined the stability of two different hexapod frames at increasing strut angles and the possible use of an additional strut to aid stability.

Introduction

Hexapod frames have certain advantages over standard circular frames, however disadvantages include a rattle and instability at some strut angles. This could be particularly important when larger diameter rings are used over a shorter distance resulting in lower ring strut angles such as in the femur.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_23 | Pages 11 - 11
1 May 2013
Calder P McGrath A Chasseaud M Timms A Goodier W
Full Access

We present the results of a new non-invasive lengthening nail enabling accurate control of the lengthening process and joint rehabilitation.

Introduction

The use of intramedullary lengthening nails have gained popularity as they reduce common complications associated with external fixators, including infection, joint stiffness, bone regenerate deformity, late fracture and patient implant acceptance. Current nails however are associated with complications including implant breakage, mechanical failure, runaway nail and requiring MUA to restart or obtain segment lengthening. The Precice nail incorporates magnet technology with a hand held device allowing non-invasive lengthening. The nail is also reversible allowing shortening if required. Physiotherapy can continue throughout treatment to maintain joint range of motion without concern of uncontrolled nail runaway. The lengthening is axial reducing shear/torsional forces on the regenerate.

Method

The lengthening of 4 femora was undertaken in 3 patients, mean age 34 yrs for post-traumatic shortening and short stature. A standard technique included an Ilizarov corticotomy followed by a 6 day latent period. Patients were mobilised partial weight bearing and knee range of motion maintained. The femora were lengthened one third of a millimetre three times per day. Radiographic and clinical review was performed every 2 weeks.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_23 | Pages 1 - 1
1 May 2013
Welck MJ Calder P Eastwood D
Full Access

Purpose of Study

To see if the addition of a locking plate to FD rod fixation of osteogenesis imperfecta confers extra strength and allows earlier mobilisation.

Introduction

Osteogenesis imperfecta is a heterogeneous group of disorders with congenital osseous fragility. The goal of surgery is to minimise the incidence of fracture and correct deformity. The concept of multilevel osteotomies and intramedullary fixation with a non-extendable nail was popularised by Sofield and Millar in 1959. The Bailey Dubow telescoping nail was introduced in 1963. The Fassier-Duval (FD) telescoping nail is a more recent design inserted via smaller incisions, in conjunction with percutaneous osteotomies. However there are still problems. Often the medullary canal may be too narrow to harbour a nail of adequate size for the body. Furthermore they do not give significant rotational control, which is compounded by the elasticity of the soft tissues.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_16 | Pages 70 - 70
1 Apr 2013
Smitham P Scarsbrook C Barker A Calder P
Full Access

Introduction

Fracture healing is governed by biological and mechanical factors. Circular frames are one method to fix fractures. Recently, the number of frame designs that are available has increased and these different designs may have different effects on the mechanical environment created. The senior author has been concerned by the stability of the construction when a short frame is used. This study examined the stability of different frames and the possible use of additional 7th struts to aid stability.

Method

The frame configuration was modified with increasing strut angles from 15° − 70°. Each frame was cyclically tested in compression to 200N. The Taylor Spatial Frame was retested with the addition of a seventh strut.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_6 | Pages 3 - 3
1 Feb 2013
Wright J Randhawa S Gooding C Lowery S Calder P
Full Access

Identification of the paediatric orthopaedic patient at high risk of venous thromboembolism (VTE) can allow a targeted approach to thromboprophylaxis. There is currently no national consensus on the correct method of risk assessment in this patient group. The Royal National Orthopaedic Hospital has developed a guideline using the evidence available to allow stratification of risk for the paediatric orthopaedic patient.

A list of departments offering specialist paediatric orthopaedic surgery was obtained from the member list of the British Society of Paediatric Orthopaedic Surgeons (BSCOS). These hospitals were contacted via telephone interview to determine if they have a specific guideline or risk assessment proforma for paediatric VTE risk.

A total of 74 hospitals were identified with a specialist paediatric orthopaedic practice in the United Kingdom. A response rate was gained from 100% of these hospitals. Only 3/74 of these hospitals had a guideline or protocol in place for the formal assessment of VTE risk in the paediatric patient (Royal National Orthopaedic Hospital, Stanmore; Sheffield Children's Hospital; Barts & the London NHS Trust). All three hospitals were able to provide details of their guideline. Both the RNOH and Barts & the London commented that their guideline was based on that of the Sheffield group, with adaptations for their own requirements.

The majority of hospitals in the UK with a paediatric orthopaedic interest do not have guidance available for the management of VTE risk. Presented here is the outcome of using the limited evidence available, in combination with expert opinion, to develop a guideline suitable for the requirements of a paediatric unit in an orthopaedic hospital. This may be of benefit to other units producing their own guidelines, producing thought and discussion as to the specific requirements of paediatric patients undergoing orthopaedic procedures.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_7 | Pages 2 - 2
1 Feb 2013
Roberts D Panagiotidou A Calder P
Full Access

Purpose

To investigate the incidence of deep vein thrombosis (DVT) and pulmonary embolism (PE) with external fixator use and to help establish whether current guidelines are appropriate.

Methods

Case notes of individuals undergoing external fixator application by the senior author (PC) from March 2005 to June 2011 were examined. In this period 207 individuals underwent 255 primary applications of Ilizarov, Taylor Spatial Frame (TSF) or monolateral fixator. Fixators applied were 173 tibial, 63 femoral and 19 to other bones. Records were obtained for 182 individuals (88%), representing 214 operations (84%).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_6 | Pages 17 - 17
1 Feb 2013
Stöhr K Randhawa S Calder P Tennant S Hashemi-Nejad A Eastwood D
Full Access

Purpose of study

We hypothesised that Vitamin D deficiency could be related to SUFE in children without endocrinological abnormalities. We therefore sought to examine prevalence and severity of Vitamin D insufficiency in a cross-section of SUFE patients.

Methods

Vitamin D levels were tested for at time of hospital admission for operative treatment of SUFE. Seven patients, between the months of July 2011 to November 2011, presented to our institution. All were chronic, stable slips treated with in-situ screw fixation. All patients presented in the summer months and were operated on within 3 weeks of presentation.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_2 | Pages 6 - 6
1 Jan 2013
Rudge B Jennings R Calder P
Full Access

Introduction

Lower limb mal-alignment as a result of fracture malunion can result in knee degenerative arthritis or predispose to early arthroplasty failure due to the altered mechanical axis. The choice of corrective osteotomy is often determined by potential complications. Opening wedge osteotomy is associated with poor bone healing especially in adult diaphyseal bone. Distraction osteogenesis enables gradual deformity correction with the gap filled by regenerate bone. Bone formation however is formed less favourably in the diaphysis and metaphyseal osteotomy is advised. We present a consecutive series of adult tibial diaphyseal correction using the Taylor Spatial Frame utilising the method of distraction osteogenesis.

Method

15 adults, 11 male and 3 female, underwent tibial deformity correction. A mid diaphyseal osteotomy was made using minimal soft tissue dissection and an osteotome. The site was determined by the centre of rotation of angulation (CORA). After a 6 day latency period distraction was undertaken by the Taylor Spatial Frame. Patients were encouraged to fully weight bear throughout the treatment process. Following regenerate consolidation the frame was removed and a below knee weight bearing cast applied for 4 weeks.