header advert
Results 1 - 5 of 5
Results per page:
Applied filters
Content I can access

Include Proceedings
Dates
Year From

Year To
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 91 - 91
1 Apr 2019
Watanabe H Majima T Tsunoda R Oshima Y Uematsu T Takai S
Full Access

Introduction

The hip hemiarthroplasty in posterior approach is a common surgical procedure at the femoral neck fractures in the elderly patients. However, the postoperative hip precautions to avoid the risk of dislocations are impeditive for early recovery after surgery. We used MIS posterior approach lately known as conjoined tendon preserving posterior (CPP) approach, considering its enhancement of joint stability, and examined the intraoperative and postoperative complications, retrospectively.

Methods

We performed hip hemiarthroplasty using CPP approach in 30 patients, and hip hemiarthroplasty using conventional posterior approach in 30 patients, and both group using lateral position with the conventional posterior skin incision. The conjoined tendon (periformis, obturator internus, and superior/inferior gemellus tendon) was preserved and the obturator externus tendon was incised in CPP approach without any hip precautions postoperatively. The conjoined tendon was incised in conventional approach using hip abduction pillow postoperatively.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 74 - 74
1 May 2016
Taniguchi S Hachiya Y Watanabe H Muramatsu K Tanaka K Yoshioka A
Full Access

Purpose

Our primary purpose was to study the rate of occurrence and the natural course of pseudotumors in patients who had not required a revision procedure. Our secondary purpose was to see if there is a relationship between serum metal ion analysis and clinical symptoms with metal-on-metal (MOM) hip arthroplasty.

Patients and Methods

We used repeated metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) to screen 17 unrevised hips (mean patient age 63.0 years, 43 to 83 years) with pseudotumors and 26 hips (mean patient age 63.2 years, 47 to 83 years) without pseudotumors. Patients with 17 MOM, 17 ceramic-on-polyethylene (COP) and 7 ceramic on ceramic (COC) who had undergone repeated MARS MRI were evaluated with or without any symptoms. We utilized MARS MRI to score the type of pseudotumors using the Hart method. The mean post-operative time to the first MARS MRI scan was 30.0 months (8 to 96), and the time between the first and the second MARS MRI scan was eleven months (6 to 12). Serum Cr and Co ion measurements were undertaken at the time of both MRIs and analyzed only after MOM total hip arthroplasty.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 19 - 19
1 Jan 2016
Hachiya Y Watanabe H Taniguchi S Muramatsu K Tanaka K Yoshioka A Ando K
Full Access

(Introduction)

Metal on Metal (MoM) THA bearing as the second generation Total Hip Arthroplasty, widely came into use in Japan since 2000s. And it was expected to be able to ensure long-term use, the range of motion in the joints after surgeries, and the resistance to the dislocation, because MoM THAhad been considered to be able to use the large diameter head for its lower wear. However, there are some reports that the metal wear debris from MoM bearing surface generates the elevated serum ion level in the blood and the incidence of pseudotumor may occur subsequent to the metal wear debris. We performed MoM THA for 291 joints in 234 patients in our hospital since May 2005. But now, we refrain to use this. In this time, we will describe two cases of pseudotumor after implantation of MoM THA.

(Case1) Age 64 years, female

This case showed the hip osteoarthritis on the right side, and we performed MoM THA in 2005. After that, she had slipped just prior to the three-year postoperative check-up, andstarted swelling up, hip joint pain, and the rise in CRP. Then, we performed to remove pesudotumor in 2008 and her CRP turned into negative. However, she was repeating hip dislocation several times and an MRI showed recur of pseudotumor. Finally, we changed her metal liner into a polyethylene liner in 2012.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 122 - 122
1 Jan 2016
Watanabe H Sakamoto M
Full Access

There have been numerous reports regarding “pseudotumor” associated with hip arthroplasty. We present two reports in which main etiology in the pseudotumor formation was titanium (Ti), but not cobalt-chromium (Co-Cr). We should keep in mind that Ti analysis is essential in some cases.

(Case 1) A 68-year-old male presented to our institution because of right hip pain and lower extremity swelling four years after a bipolar hemiarthroplasty. MRI predicted a cystic pseudotumor. However, revision surgical findings showed no apparent cause of ARMD previously described in the literatures. Postoperative analysis showed that the metal debris mainly originated from the Ti alloy itself. (Case reports in Orthopedics, vol.2014, Article ID 209461, 4 pages)

(Case 2) A 77-year-old female presented to our institution because of right hip pain and swelling six years after a total hip arthroplasty using a cable trochanteric reattchment. Plain radiographs demonstrated evidences of severe osteolysis and multiple fragments of the broken cable. However, MRI predicted a psudotumor(See Figure 1). Postoperative analysis clarified that main etiology in the pseudotumor formation was the stem mede of Ti, but not the cable made of Co-Cr.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 201 - 201
1 Dec 2013
Watanabe H Hachiya Y Murata H Muramatsu K Taniguchi S Kondo M Tanaka K
Full Access

Introduction

Higher concentrations of metal ion levels after Metal-on-metal (MoM) THA are a cause for concern. Elevated cobalt (Co) and chromium (Cr) ion levels in the blood indicate metal wear, and may predict secondary soft-tissue damage (adverse reaction to metal debris; ARMD). Although, it is well known that concentrations of metal ion levels are elevated in the short term after MoM, the long-term consequences in ion concentration and risk factors for increased ion levels are not clarified. We sequentially investigated the postoperative Co and Cr ion levels after MoM THA and the relationship between the metal ion levels and several risk factors.

Materials and Methods

We reviewed the data on one hundred and eighty six patients of two hundred ninety one MoM THA cases. The one hundred eighty six patients were measured at least three times after a MoM THA surgery over a five year (2005–2010) period in our institution. Serum cobalt and chromium levels were measured by inductor coupled plasma – mass spectrometry at several times in follow-up period, (measured at the preoperative period, the third month, the sixth month, the first year, the second year, and the fourth year after MoM THA). Furthermore, we investigated the correlation between the metal ion levels and various factors which might influence the release of metal ions, such as Body mass index (BMI), renal function, femoral head size, unilateral or bilateral THA, the cup position, and postoperative activity. The renal function was evaluated by measuring estimated glomerular filtration ratio (GFR) at preoperative examination. A postoperative activity was assessed with a pedometer measurement counting number of steps a day. A cup position was evaluated by lateral inclination measured by X-ray or computed tomography.