Recent total knee arthroplasty (TKA) designs have featured more anatomic morphologies and shorter tibial keels. However, several reports have raised concerns regarding the impact of these modifications on implant longevity. This study's purpose is to report the early performance of a modern, cemented TKA design. All patients who received a primary, cemented TKA from 2012 to 2017 with a minimum two-year follow-up were included. This implant features an asymmetric tibial baseplate and a shortened keel. Patient demographics, Knee Society Scores (KSS), and component alignment were recorded, and Kaplan-Meier survivorship analyses were performed.Introduction
Methods
Surgical management of PJI remains challenging with patients failing treatment despite the best efforts. An important question is whether these later failures reflect reinfection or the persistence of infection. Proponents of reinfection believe hosts are vulnerable to developing infection and new organisms emerge. The alternative hypothesis is that later failure is a result of an organism that was present in the joint but was not picked up by initial culture or was not a pathogen initially but became so under antibiotic pressure. This multicenter study explores the above dilemma. Utilizing next-generation sequencing (NGS), we hypothesize that failures after two stage exchange arthroplasty can be caused by an organism that was present at the time of initial surgery but not isolated by culture. This prospective study involving 15 institutions collected samples from 635 revision total hip (n=310) and knee (n=325) arthroplasties. Synovial fluid, tissue and swabs were obtained intraoperatively for NGS analysis. Patients were classified per 2018 Consensus definition of PJI. Treatment failure was defined as reoperation for infection that yielded positive cultures, during minimum 1-year follow-up. Concordance of the infecting pathogen cultured at failure with NGS analysis at initial revision was determined.Introduction
Methods
In the setting of a “dry” aspiration, saline lavage is commonly used to obtain a sample for analysis. The purpose of this study is to prospectively determine the impact of saline lavage on synovial fluid markers in revision arthroplasty. 79 patients undergoing revision hip (19) and knee (60) arthroplasty were enrolled. Intraoperatively, prior to arthrotomy, the maximum amount of fluid possible was aspirated to simulate a dry-tap (“pre-lavage”) followed by subsequent injection with 20 mL of normal saline and re-aspiration (“post-lavage”). Pre and post-lavage synovial white blood cell (WBC) count, percent polymorphonuclear cells (%PMN), and cultures were compared. Statistical analyses utilized the Wilcoxon signed-rank test.Background
Methods