Results 1 - 20 of 30
Results per page:
Bone & Joint Research
Vol. 13, Issue 4 | Pages 157 - 168
4 Apr 2024
Lin M Chen G Yu H Hsu P Lee C Cheng C Wu S Pan B Su B

Aims

Osteosarcoma is the most common primary bone malignancy among children and adolescents. We investigated whether benzamil, an amiloride analogue and sodium-calcium exchange blocker, may exhibit therapeutic potential for osteosarcoma in vitro.

Methods

MG63 and U2OS cells were treated with benzamil for 24 hours. Cell viability was evaluated with the MTS/PMS assay, colony formation assay, and flow cytometry (forward/side scatter). Chromosome condensation, the terminal deoxynucleotidyl transferase dUTP nick end labelling (TUNEL) assay, cleavage of poly-ADP ribose polymerase (PARP) and caspase-7, and FITC annexin V/PI double staining were monitored as indicators of apoptosis. Intracellular calcium was detected by flow cytometry with Fluo-4 AM. The phosphorylation and activation of focal adhesion kinase (FAK) and signal transducer and activator of transcription 3 (STAT3) were measured by western blot. The expression levels of X-linked inhibitor of apoptosis protein (XIAP), B-cell lymphoma 2 (Bcl-2), B-cell lymphoma-extra large (Bcl-xL), SOD1, and SOD2 were also assessed by western blot. Mitochondrial status was assessed with tetramethylrhodamine, ethyl ester (TMRE), and intracellular adenosine triphosphate (ATP) was measured with BioTracker ATP-Red Live Cell Dye. Total cellular integrin levels were evaluated by western blot, and the expression of cell surface integrins was assessed using fluorescent-labelled antibodies and flow cytometry.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 11 - 11
4 Apr 2023
O’Beirne A Pletikosa Z Cullen J Bassonga E Lee C Zheng M
Full Access

Nerve transfer is an emerging treatment to restore upper limb function in people with tetraplegia. The objective of this study is to examine if a flexible collage sheet (FCS) can act as epineurial-like substitute to promote nerve repair in nerve transfer.

A preclinical study using FCS was conducted in a rat model of sciatic nerve transection. A prospective case series study of nerve transfer was conducted in patients with C5-C8 tetraplegia who received nerve transfer to restore upper limb function. Motor function in the upper limb was assessed pre-treatment, and at 6-,12-, and 24-months post-treatment.

Macroscopic assessment in preclinical model showed nerve healing by FCS without encapsulation or adhesions. Microscopic examination revealed that a new, vascularised epineurium-like layer was observed at the FCS treatment sites, with no evidence of inflammatory reaction or nerve compression. Treatment with FCS resulted in well-organised nerve fibres with dense neurofilaments distal to the coaptation site. Axon counts performed proximal and distal to the coaptation site showed that 97% of proximal axon count of myelinated axons regenerated across the coaptation site after treatment with CND. In the proof of concept clinical study 17 nerve transfers were performed in five patients. Nerve transfers included procedures to restore triceps function (N=4), wrist/finger/thumb extension (N=6) and finger flexion (N=7). Functional motor recovery (MRC ≥3) was achieved in 76% and 88% of transfers at 12 and 24 months, respectively.

The preclinical study showed that FCS mimics epineurium and enable to repair nerve resembled to normal nerve tissue. Clinical study showed that patients received nerve transfer with FCS experienced consistent and early return of motor function in target muscles. These results provide proof of concept evidence that CND functions as an epineurial substitute and is promising for use in nerve transfer surgery.


Bone & Joint Open
Vol. 3, Issue 5 | Pages 348 - 358
1 May 2022
Stokes S Drozda M Lee C

This review provides a concise outline of the advances made in the care of patients and to the quality of life after a traumatic spinal cord injury (SCI) over the last century. Despite these improvements reversal of the neurological injury is not yet possible. Instead, current treatment is limited to providing symptomatic relief, avoiding secondary insults and preventing additional sequelae. However, with an ever-advancing technology and deeper understanding of the damaged spinal cord, this appears increasingly conceivable. A brief synopsis of the most prominent challenges facing both clinicians and research scientists in developing functional treatments for a progressively complex injury are presented. Moreover, the multiple mechanisms by which damage propagates many months after the original injury requires a multifaceted approach to ameliorate the human spinal cord. We discuss potential methods to protect the spinal cord from damage, and to manipulate the inherent inhibition of the spinal cord to regeneration and repair. Although acute and chronic SCI share common final pathways resulting in cell death and neurological deficits, the underlying putative mechanisms of chronic SCI and the treatments are not covered in this review.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_11 | Pages 29 - 29
1 Sep 2021
Lee C Lee MG Lim WJ Liu Y Pakdeenit B Kim JS
Full Access

Although interlaminar endoscopic lumbar discectomy (IELD) is considered to be less invasive than microscopic lumbar discectomy (MLD) in treatment of lumbar herniated nucleus pulposus, the radiologic change of multifidus muscles by each surgery has rarely been reported. The aim of the present study was to compare the quantitative and qualitative changes of multifidus muscles between two surgical approaches and to analyze the correlation between various parameters of multifidus muscles and long term surgical outcome.

21 patients who received MLD and 18 patients who received IELD in a single tertiary hospital were enrolled and their preoperative, postoperative (≤15 days), and follow-up (≥6 months) MRIs were analyzed. The cross-sectional area (CSA) and fatty degeneration rate (FD) were quantitatively estimated at the level of surgery. The correlations among CSA, FD, body mass index, follow-up visual analogue scale(VAS) and Oswestry Disability Index(ODI) were assessed.

Mean intervals of postoperative MRI and follow-up MRI from surgery were 3.0±3.7 days and 14.5±10.7 months, respectively. During the follow-up period, VAS was improved from 7.1±1.3 to 2.1±1.8 in MLD and from 8.2±1.4 to 2.2±1.8 in IELD. In cases of MLD, comparing with preoperative MRI, ipsilateral CSA was significantly increased in postoperative MRI (795.6mm2 vs. 906.5mm2, p<0.01), but it was not significantly different in follow-up MRI (795.6mm2 vs. 814.4mm2, p=1.00). However, in case of IELD, the ipsilateral CSAs in preoperative, postoperative, and follow-up periods were 892.0 mm2, 909.3 mm2, and 900.3 mm2, respectively. These changes were not significant over time (p=0.691). The ipsilateral FDs were not significantly changed between preoperative and follow-up periods in both MLD (21.4% vs. 20.9%, p=0.81) and IELD groups (23.5% vs. 21.8%, p=0.19). The increment of ipsilateral CSA had significant correlations with follow-up ODI (r=−0.368, p=0.02).

Comparing with IELD, MLD induced more surgical trauma on multifidus muscle in postoperative period, but the muscular damage was recovered in follow-up period. IELD can minimize surgical trauma on multifidus muscle showing similar pain relief as MLD. Favorable surgical outcome in follow-up period may be related to increment of multifidus muscle volume.

Figure 1

(A-C) The multifidus muscles in preoperative, postoperative, and follow-up periods, respectively, in patient with MLD. Comparing with preoperative period, the CSA of right multifidus muscle (ipsilateral side) was increased in postoperative period, but recovered in follow-up period. (D-F) The multifidus muscle in preoperative, postoperative, and follow-up periods, respectively, in patient with IELD. The CSA of left multifidus muscles (ipsilateral side) was not significantly changed over time. Comparing preoperative MRIs with follow-up MRIs, the FDs of multifidus muscles were not significantly changed regardless of surgical technique.

Figure 2

The CSA was measured by marking region of interest (ROI) and FD was measured by calculating the rate of pixels beyond the threshold in ROI. All measurements were performed using ImageJ software (version 1.52a, National Institutes of Health, Bethesda, Maryland, USA).

For any figures or tables, please contact the authors directly.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 46 - 46
1 May 2017
Page P Lee C Rogers B
Full Access

Background

Fractures of the femoral neck occurring outside the capsule of the hip joint are assumed to have an intact blood supply and hence their conventional management is by fixation rather than arthroplasty. The dynamic hip screw and its variants have been used over many years to fix such fractures but have inherent vulnerabilities; they require an intact lateral femoral cortex, confer a relatively long moment arm to the redistribution of body weight and may cause a stress riser due to the plate with which they are fixed to the femur. Intramedullary devices for fixation of proximal femoral fractures have a shorter moment arm, can be distally locked with reduced perforation of the femoral cortex and are believed to be inherently more stable. For these reasons, a number of surgeons believe them to be superior to the DHS for all extracapsular fractures and their use is now widespread. In this study, we present the usage trends of both devices in extracapsular fractures over the last five years and set these results in the context of patient demographics.

Methods

Our departmental electronic patient management system was used to identify all patients undergoing surgery coded as either DHS or its variants or intramedullary fixation of hip fracture. The patients’ age, sex and American Society of Anaesthesiologists grading were recorded. Comparison between groups was made using appropriate tests in SPSS.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_5 | Pages 34 - 34
1 Mar 2017
Mueller U Lee C Thomsen M Heisel C Kretzer J
Full Access

Introduction

This study was performed to investigate the failure mechanism of one specific hip arthroplasty cup design that has shown a high clinical failure rate. The aim of this study was to identify general design problems of this polyethylene inlay.

Material and Methods

55 consecutive retrievals of a cementless screw ring (Mecron) were collected. In any case a 32 mm ceramic head was used. All implants failed due to aseptic loosening. The follow-up of the implants was 3 to 16 years. We recorded backside wear, fatigue of the polyethylene at the flanges on the outer rim and at the cup opening (32 mm inner diameter). To assess the deformation of the inlay, the smallest and the median diameter of the cup opening were measured using a 3 dimensional coordinate measuring machine (Multisensor, Mahr, Germany).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 115 - 115
1 Feb 2017
Chun Y Cho Y Lee C Bae C Rhyu K
Full Access

Purpose

This study was performed to evaluate clinical and radiographic outcomes of Hip Resurfacing Arthroplasty for treatment of haemophilic hip arthropathy.

Material & Method

Between 2002 and 2013, 17 cases of hip resurfacing arthroplasties were performed in 16 haemophilic patients (13 cases of haemophilia A, 2 cases of haemophilia B, 2 cases of von Willebrand disease). The average age of the patients was 32.5(range: 18∼52) years. The average follow up period from the operation was 6.3 (range: 2∼13) years. In this study, the subjects that completed follow-up were composed of 5 cases composed of patients who were treated with Conserve plus® hip resurfacing system, 5 cases composed of patients who were treated with Durom® hip resurfacing system, 4 cases who were treated with ASR® hip resurfacing system, and 3 cases who were treated with Birmingham® hip resurfacing system. The Modified Harris hip score, the range of motion of the hip joint, perioperative coagulation factor requirements and complications associated with bleeding were evaluated as part of the clinical assessment. For the radiographic assessment, fixation of component, presence of femoral neck fracture, osteolysis, loosening and other complications were evaluated.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 143 - 143
1 May 2016
Yoon S Lee C Hur J Kwon O Lee H
Full Access

Introduction

Mechanically aligned total knee arthroplasty(TKA) relies on restoring the hip-knee-ankle angle of the limb to neutral or as close to a straight line as possible. This principle is based on studies that suggest limb and knee alignment is related long term survival and wear. For that cause, there has been recent attention concerning computer-assisted TKA and robot is also one of the most helpful instruments for restoring neutral alignment as known. But many reported data have shown that 20% to 25% of patients with mechanically aligned TKA are dissatisfied. Accordingly, kinematically aligned TKA was implemented as an alternative alignment strategy with the goal of reducing prevalence of unexplained pain, stiffness, and instability and improving the rate of recovery, kinematics, and contact forces. So, we want to report our extremely early experience of robot-assisted TKA planned by kinematic method.

Materials and Methods

This study evaluated the very short term results (6 weeks follow up) after robot-assisted TKA aligned kinematically. 50 knees in 36 patients, who could be followed up more than 6 weeks after surgery from December 2014 to January 2015, were evaluated prospectively. The diagnosis was primary osteoarthritis in all cases. The operation was performed with ROBODOC (ISS Inc., CA, USA) along with the ORTHODOC (ISS Inc., CA, USA) planning computer. The cutting plan was made by single radius femoral component concept, each femoral condyles shape-matched method along the transverse axis using multi-channel CT and MRI to place the implant along the patient's premorbid joint line. Radiographic measurements were made from long bone scanograms. Clinical outcomes and motion were measured preoperatively and 6 weeks postoperatively.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_8 | Pages 10 - 10
1 Jun 2015
Lee C King C Freeman R Edmondson M Guthrie H
Full Access

The “Golden Patient” is suitability worked up to be the first theatre case of the day; the aim being to improve theatre efficiency. A previous audit of theatre activity demonstrated that the average knife to skin time being achieved across 3 daily trauma lists was 10.12. Over 2-months we introduced a Golden Patient Pathway and completed the audit cycle. The pathway involved a checklist to ensure the completion of essential clinical tasks for each designated golden patient. Activities from 74 trauma theatre cases were reviewed. 47 golden patients remained first whilst 27 were deferred for reasons including non-suitability for golden patient status and emergent cases given clinical priority. The average theatre call time was 24 minutes earlier and the average knife-to-skin time was 15 minutes earlier than non-golden patients during the re-audit. However, when compared to the initial audit the knife-to-skin time had only improved by 3 minutes. Reasons effecting theatre efficiency are multifactorial and other organisational changes had occurred between the audits. This study demonstrates that while the Golden Patient Pathway can improve theatre start times it is not the whole solution. Communication, anaesthetic job plans, portering arrangements, equipment storage and theatre staffing also need to be reviewed.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_17 | Pages 19 - 19
1 Nov 2014
Yousaf S Lee C Khan A Hossain N Edmondson M
Full Access

Introduction:

Early stabilization has the potential to expedite early return to function and reduce hospital stay thus reducing cost to health care. A clinical audit was performed to test the hypothesis that early surgical stabilization lowers the rate of soft tissue complications and is not influenced by choice of distal fibular implants used for stabilization of ankle fractures.

Methods:

All surgically treated adult patients with isolated unstable ankle fracture were included from April 2012 to April 2013 at a MTC in UK. Patients with poly-trauma were excluded.

All patients underwent a standard surgical protocol: aim for early definitive surgical fixation (ORIF) within 24 hours however if significantly swollen than temporary stabilization with an external fixation followed by a staged definitive fixation.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 367 - 367
1 Mar 2013
Yoon S Lee C Hur J Kwon O Trabish M Lee H Park J
Full Access

Introduction

The success of total knee arthroplasty depends on many factors, including the preoperative condition of the patient, the design and materials of the components and surgical techniques. It is important to position the femoral and tibial components accurately and to balance the soft tissues. Malpositioning of the component can lead to failures due to aseptic loosening, instability, polyethylene wear and dislocation of the patella. In order to improve post-operative alignment, computer-aid systems have been developed for total knee arthroplasty. Many clinical and experimental studies of these systems have shown that the accuracy of implanted components can be improved in spite of the increase in costs and operating time. This may not, however, improve the outcome in the short-term. Restoration of the normal mechanical axis of the knee and balancing of the surrounding soft tissues have been shown to have an important bearing on the final outcome of knee replacement operations. In severely deformed knees, whether varus or valgus, these goals may be difficult to achieve. We compared the radiologic results of the mechanical axis and implant position of Total Knee Arthroplasty using a robot-assisted method with conventional manually implanted method in severe varus deformed knee.

Materials and Methods

A data set of 50 consecutive cases that were performed from April 2007 to December 2010 using the robot assisted TKA(Group A) were compared with a data set of 50 consecutive cases from the same period that were done using conventional manual TKA(Group B). All cases had a preoperative mechanical varus deformity >15° and one brand of implant was used on all cases. The diagnosis was primary osteoarthritis in all knees. The operations were performed by one-senior author with the same robot system, ROBODOC (ISS Inc., CA, USA) along with the ORTHODOC (ISS Inc., CA, USA) planning computer. (See Figure 1.) The radiological evaluations included mechanical axis, implant position (α,β,γ,δ angle) according to the system of American Knee Society.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 335 - 335
1 Mar 2013
Song I Lee C
Full Access

Purpose

We analyzed the frequency, causes and treatment of dislocation of polyethylene insertion among various causes of failure of unicompartmental knee arthroplasty.

Materials and Methods

We studied 69 knee joints of 65 patients who underwent medial unicompartmental knee arthroplasty using from June 2005 to December 2010. Average age was 61.8 and average follow-up period was 20 months. Radiologic results evaluated preoperative and postopertative mechanical axis deviation, tibio-fibular angle and postoperative implant position in total 69 knees(A group), failed 15 cases(B group) and 10 cases(C group) of bearing dislocation. We demonstrated treatment on failure group and analyzed preoperative and postoperative HSS and Lysolm score.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 366 - 366
1 Mar 2013
Yoon S Lee C Hur J Kwon O Trabish M Lee H Park J
Full Access

Introduction

Since Smith-Peterson's glass mold arthroplasty in 1939, hip resurfacing arthroplasty was developed and introduced to orthopaedic surgery field but it had many problem like early loosening. Recently it is being popular for some indication as development of new implant design and manufacturing. There are still many suggested advantages of hip resurfacing arthroplasty. These include bone conservation, improved function as a consequence of retention of the femoral head and neck and more precise biomechanical restoration, decreased morbidity at the time of revision arthroplasty, reduced dislocation rates, normal femoral loading and reduced stress-shielding, simpler management of a degenerated hip with a deformity in the proximal femoral metaphysic, an improved outcome in the event of infection, and a reduced prevalence of thromboembolic phenomena as a consequence of not using instruments in the femur. But, there are limited or inconsistent data to support some of these claims regarding the benefits of hip resurfacing including the potential for a more natural feel because of the minimal disturbance of the proximal part of the femur resulting in a better and faster functional outcome. We evaluate the short term results of hip resurfacing arthroplasty using custom patient-specific tooling for prosthesis placement for better standardization.

Materials and Methods

40 cases, 36 patients(male:20, female:16) those of who were candidates of a Hip Resurfacing procedure, participated in the study. Mean follow up period was 2.5 years (8 months ∼3 years). A CT scan was performed on each patient and a 3D model was generated using the computer tomography dataset. From this model a bone-surface skin was extracted and this data set was used to create a personalized jig. Detailed analysis of the native bone structure was then used to preoperatively plan the appropriate size and position of the implant. A mean 7 degree corrective valgus angle was prescribed on all cases. Postoperative radiological datasets were superimposed onto preoperative plan position and offsets were measured. Operative times were recorded per step during the procedure. Surgeon comfort and ease of use was also noted.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 336 - 336
1 Mar 2013
Song I Lee C
Full Access

Background

We have performed total knee arthroplasties for valgus and varus in the knees of one person and investigate the clinical characteristics of these patients and the relationship between the kind of deformity and postoperative result.

Methods

From March 2002 to February 2010, 25 patients who had simultaneous varus and valgus knee deformities underwent total knee arthroplasties and followed more than 12 months were included. The average age was 66.9 years and the average follow-up period was 61.1 months. Follow-up imaging assessments were taken and clinical outcome were evaluated using HSS score at last follow-up.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 518 - 518
1 Sep 2012
Lee C Itoi E Kim S Lee J Jung K Lee S Suh K
Full Access

Introduction

Many literatures regarding more specific tests to diagnose the supraspinatus tendon injuries and the best rehabilitation methods to strengthen the supraspinatus have been published. However, conflicting results have been reported. 2-deoxy-2-[18F] fluoro-D-glucose (FDG) positron emission tomography (PET) has been recently used to assess skeletal muscle activities in various fields.

Purpose

To evaluate & compare the metabolic activities of deltoid & rotator cuff muscles after the full-can & empty-can exercises using PET-CT.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXIX | Pages 96 - 96
1 Sep 2012
Kumar A Lee C
Full Access

We hypothesised whether MIS techniques confer any benefit when treating thoracolumbar burst fractures.

This was a prospective, non-randomised study over the past seven years comparing conservative (bracing:n=27), conventional surgery (open techniques:n=23) and MIS techniques (n=21) for stabilisation and correction of all thoracolumbar spinal fractures with kyphosis of >200, using Camlok S-RAD 90 system (Stryker Spine). All patients previously had normal spines, sustained only a single level burst fracture (T12, L1 or L2) as their only injury. Age range 18–65 years.

All patients in both operatively treated groups were corrected to under 100 of kyphosis, posteriorly only. All pedicle screws/rods were removed between 6 months and 1 year post surgery to remobilise the stabilised segments once the spinal fracture had healed, using the original incisions and muscle splitting/sparing techniques. Patients were assessed via Oswestry Disability Index (ODI) and work/leisure activity status 1 year post fracture.

The conservatively treated group fared worst overall, with highest length of stay, poorest return to work/activity, and with a proportion (5/27) requiring later intervention to deal with post-traumatic deformity. 19/27 returned to original occupation, at average 9 months. ODI 32%.

Conventional open techniques fared better, with length of stay 5 days, most (19/23) returning to original work/activity, and none requiring later intervention. Average return to work was at 4 months. ODI 14%.

MIS group fared best, with shorter length of stay (48 hours), all returning to original work/activity at average 2 months, and none requiring later intervention. ODI negligible.

There was no loss of correction in either operatively treated groups.

The Camlok S-RAD 90 system is a powerful tool for correction of thoracolumbar burst fractures, and maintains an excellent correction.

MIS techniques provide the best outcomes in treating this group of spinal fractures, and offer patients the best chance of restoration to pre-fracture levels of activity.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_III | Pages 19 - 19
1 Feb 2012
Mann H Goddard N Choudhury Z Lee C
Full Access

Haemophilia care has steadily improved over the years and especially so during the last decade. The routine use of prophylactic treatment has undoubtedly resulted in a significant improvement in the life-style, quality of life and life expectancy of these patients. However despite our best efforts there is still a group of young adults who have a severe degree of knee joint destruction as a result of repeated articular bleeding episodes during their early years.

The knee is the most common joint affected in haemophilia (50%). The repeated articular bleeding episodes during the patients' early years leads to the onset of pain and significant functional disability at a time when they require the best possible quality of life. The major objective of total joint replacement is to reduce the level of pain in the affected joint and, in addition, a significant reduction in the frequency and number of joint bleeds, which improves both function and mobility.

The results of 60 primary total knee replacements performed in 42 patients with severe haemophilia between 1983 and 2003 were reviewed retrospectively. Functional results were assessed using the Hospital for Special Surgery (HSS) knee score both pre- and post-operatively. Kaplan-Meier survivorship analysis was used to calculate prosthetic survival.

The mean age of patients was 43.35 (range 25-70yrs). The overall prevalence of infection was less than 2%. The HSS clinical score was excellent or good for 95% of the knees.

We believe that total joint replacement is a safe and effective procedure in the management of haemophilic joint arthropathy. The latest techniques using continuous infusion and recombinant factor replacement have gone a long way to reducing the complications rate and to achieving results that match those of the general population.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 425 - 425
1 Nov 2011
Lee C Lin W Horng L Jiang C
Full Access

We conducted a prospective, randomized study comparing the outcomes of total knee arthroplasty (TKA) respectively through a quadriceps-sparing (QS) approach and a MIS medial parapatellar (MP) approach at 2-year follow-up. Sixty patients (80 knees) with primary osteoarthritis were enrolled in this study. Patients were blinded to be treated with and randomized to be grouped by either MP group (40 knees) or QS group (40 knees). Thirty-seven MIS MP TKAs and thirty-eight QS TKAs completed the 2-year follow-up.

According to the isokinetic study, the recovery of muscle strength (peak muscle torque) and normalization of muscle balance (H/Q peak-torque ratio) were comparable in both groups at either 2-month or 2-year follow-up. Tourniquet and surgical time in the QS group was significantly longer (approximately 20 minutes) than that in the MP group. The hip-knee-ankle axis measured after surgery was significantly more varus in the QS group than that in the MP group. The axis in both groups did not significantly progress at 2-year follow-up. There were no infections and no revisions at 2-year follow-up in both groups. More outlier cases (4 knees) were noted in the QS group when compared with the MP group (no outlier).

However, no differences regarding the clinic outcomes (including VAS, HSS knee score, ROM and satisfaction) were observed between these two groups after either two months or two years upon operation. In both groups, there was a significant improvement of these parameters at 2-year follow-up in contrast with 2-month follow-up and pre-operative status.

In this study, we conclude that MIS medial parapatellar TKAs could achieve comparable recovery of muscle strength, normalization of hamstring-quadriceps muscle balance and clinical outcomes when compared with QS TKAs; moreover it provides more reliable alignment and fewer complications than quadriceps-sparing TKAs.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 70 - 70
1 Jan 2011
Lee C Rajan R Roach H
Full Access

Osteoarthritis (OA) is a common degenerative disease associated with aging thatas yet has no cure. Glucosamine (Gln) is a naturally produced amino sugar that forms part of the cartilage matrix and is taken by millions of OA sufferers in the hope of alleviating their symptoms. Apart from alleviating pain, there is evidence in the literature that Gln may also be a chondroprotective drug in OA and some clinical trials have shown reduced joint space narrowing in patients taking 1mg Gln per day. However, the mechanisms by which Gln might have its beneficial effects are still uncertain.

We wanted to determine whether Gln has any influence on the aberrant gene expression that takes place in OA chondrocytes. To this end, we cultured healthy articular chondrocytes and induced aberrant gene expression with TNF-α /OSM. Healthy human chondrocytes were isolated from the cartilage of the femoral head obtained after hemiarthroplasty from four patients who had fractured the neck of their femur. Each sample was divided in to 4 groups prior the monolayer culture:

Control culture,

Gln only,

treated with TNF-α/OSM,

treated with TNF-α /OSM and Gln.

At confluency (~ 2 weeks) RNA was extracted for analysis of mRNA expression by RT-PCR. The impact of Gln on the expression if the inflammatory cytokine IL-1b and the protease MMP-13 was determined by conventional RT-PCR.

No expression of IL-1b was found in control cultures and Gln on its own did not induce expression. As expected, TNF-a/OSM induced the expression of IL-1b in all four patients. When Gln was present together with TNF-a/OSM, IL-1b expression was prevented in two patients and considerably reduced in the other two patients. With respect to MMP-13, expression was present in 3/4 cultured controls and Gln did not influence this expression. TNF-α /OSM increased expression of IL-1b, and the cytokine-induced expression was slightly reduced by Gln in 2/4 patients.

These results suggest that Gln prevents the TNF-α /OSM-induced expression of IL-1b, but has limited direct influence on MMP-13 expression, at least in vitro. If the data are applicable to the in vivo situations, the results support the proposed chondroprotective effect of glucosamine at the cellular level.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 133 - 133
1 Mar 2010
Lee C Chung S Yu J
Full Access

The prosthesis anchored to the vertebral body by a large central keel has inherent risk of angular mismatching between vertebral endplate and prosthesis endplate at large lordotic segment such as L5-S1. Theoretically, these angular mismatching can be considered to cause several problems such as segmental hyperlordosis, anterior positioning of upper prosthesis, posterior prosthetic edge subsidence, decreased ROM and poor clinical outcome. The purpose of this study is to assess whether angular mismatching between vertebral endplate and prosthesis endplate in lumbar total disc replacement (L-TDR) with ProDisc-L influence on radiological and clinical outcomes.

We evaluated 64 levels of 56 patients who were implanted with ProDisc-L from 2002 to 2006. Prosthetic levels were 38 levels of L4–5, and 26 levels of L5-S1 (8 patients had 2 level-operations of L4–5 and L5-S1). Mean follow-up was 25.6 (12–49) months. Angle of mismatching between lower endplate of upper vertebral body and upper prosthetic plate, segmental flexion/extension ROM, segmental lordosis angle at extension, distance from the posterior wall of vertebral body to posterior prosthetic edge were measured in the radiographs. Clinically VAS and ODI were evaluated. Angular mismatching between upper vertebra and prosthesis of L4–5 and L5-S1 was 1.6° (range, 0–6°) and 5.6° (0–13°) (p< 0.001) respectively, at final follow-up. Angular mismatching at immediate postoperative radiographs (2.3° in L4–5 and 4.9° in L5-S1) and at final follow-up was not significantly different (p=0.324 in L4–5, 0.620 in L5-S1). Mean segmental ROM of operated levels was 10.6° (4–22°) in L4–5 and 6.1° (2–13°) in L5-S1(p< 0.001). Mean segmental ROM, mean segmental lordosis angle, and mean distance from posterior margin of vertebral body to posterior end of prosthesis in L5-S1 were 6.8° (4–13°), 12.8° (8–17°), 3.8mm (1–6mm) in cases with angular mismatching less than 10°, and 4.6° (2–7°), 21.3° (19–25°), 6.0 mm (2–8mm) in that of 10° or more (p=0.024, < 0.001, 0.039), respectively. In L4–5 angular mismatching of more than 5° were only 2 cases without statistical significance. Clinical outcomes, VAS and ODI, of L4–5 compared with that of L5-S1 and of angular mismatching less than 10° with that of 10° or more in L5-S1 did not have difference between them (p> 0.05). Angular mismatching between lower endplate of upper vertebra with upper prosthesis endplate is more common in L5-S1 than in L4–5. L-TDR at the most lordotic level, L5-S1, implantation of upper prosthesis with mismatched angle seems to be the causes of lessened segmental ROM, increased segmental lordosis, and anterior positioning of prosthesis.