header advert
Results 1 - 6 of 6
Results per page:
The Bone & Joint Journal
Vol. 105-B, Issue 8 | Pages 880 - 887
1 Aug 2023
Onodera T Momma D Matsuoka M Kondo E Suzuki K Inoue M Higano M Iwasaki N

Aims

Implantation of ultra-purified alginate (UPAL) gel is safe and effective in animal osteochondral defect models. This study aimed to examine the applicability of UPAL gel implantation to acellular therapy in humans with cartilage injury.

Methods

A total of 12 patients (12 knees) with symptomatic, post-traumatic, full-thickness cartilage lesions (1.0 to 4.0 cm2) were included in this study. UPAL gel was implanted into chondral defects after performing bone marrow stimulation technique, and assessed for up to three years postoperatively. The primary outcomes were the feasibility and safety of the procedure. The secondary outcomes were self-assessed clinical scores, arthroscopic scores, tissue biopsies, and MRI-based estimations.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 89 - 89
1 Jan 2016
Nishio Y Onodera T Kasahara Y Seito N Takahashi D Kondo E Iwasaki N Majima T
Full Access

Introduction

Total knee arthroplasty (TKA) is a well-established procedure associated with excellent clinical results. We have previously reported that intraoperative knee kinematics correlate with the clinical outcome in mobile bearing TKA. In addition, the intraoperative knee kinematics pattern does not correlate with the degree of preoperative knee deformity in mobile bearing TKA. However, the relationship among preoperative knee deformity, intraoperative kinematics and clinical outcome in fixed bearing TKA has been unknown. The purpose of this study is to compare the relationship among preoperative knee deformity, knee kinematics after fixed bearing TKA and the clinical outcome including the subjective outcomes evaluated by the new knee society score (KSS).

Materials and Methods

A cross-sectional survey of thirty-five consecutive medial osteoarthritis patients who had a primary TKA using a CT-based navigation system was conducted. All knees had a Kellgren-Lawrence grade of 4 in the medial compartment and underwent a primary posterior stabilized TKA (Genesis II, Smith&Nephew) between May 2010 and October 2012. In all cases, a computed tomography-guided navigation system (Brain LAB, Heimstetten, Germany) was used. All surgery was performed by the subvastus approach and modified gap technique. Intraoperative knee kinematics was measured using the navigation system after implantation and closure of the retinaculum and soft tissue except for the skin. Subjects were divided into two groups based on intraoperative kinematic patterns: a medial pivot group (M group, n=19)(Figure 1) and a non-medial pivot group (N group, n=16)(Figure 2). Subjective outcomes with the new KSS and clinical outcomes were evaluated. Statistical analysis to compare the two groups was made using unpaired a Student t test.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 107 - 107
1 Jan 2016
Onodera T Kasahara Y Seito N Nishio Y Kondo E Iwasaki N Majima T
Full Access

Introduction

The effect of the implant posterior condylar offset has recently generated much enthusiasm among researchers. Some reports were concerned about the relationship between the posterior condylar offset and an extension gap. However, the posterior condylar offset was measured in a flexed knee position or in reference to femoral anatomy alone. Posterior femoral condylar offset relative to the posterior wall of the tibia (posterior offset ratio; POR) is possibly the risk of knee flexion contracture associated with posterior femoral condylar offset after TKA. However, there are no reports concerning the relationship between POR and flexion contracture in vivo. The aim of this study is to evaluate the relationship between the measurement of POR and flexion contracture of the knee in vivo.

Methods

Twenty-seven patients who underwent a primary total knee arthroplasty (PFC Sigma RP-F) were participated in the study. The lateral femoro-tibial angle (lateral FTA) was measured using lateral radiographs obtained by two procedures. Two procedures are applied to obtain true lateral radiographs of the lower extremities. (1) Full-length true lateral radiographs on standing, (2) True lateral radiographs in the prone position (Fig. 1A). ‘Posterior offset ratio’ was defined as Fig. 1B. Significant differences among groups were assessed using two-tailed Student's t-tests. Spearman's correlation analysis was performed to evaluate the relationship between lateral FTA and posterior offset ratio of patients.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 150 - 150
1 Jan 2016
Seito N Onodera T Kasahara Y Nishio Y Kondo E Iwasaki N Majima T
Full Access

Introduction

We have previously reported that patients who demonstrated medial pivot kinematics pattern after total knee arthroplasty (TKA) had better clinical results than that of non-medial pivot pattern. However, it is unclear how preoperative kinematics pattern affects postoperative knee kinematics. The aim of this study was to evaluate the relationship between preoperative and postoperative knee kinematics pattern in TKA.

Materials and Methods

The present study consists of 38 patients with medial osteoarthritis who underwent a primary TKA using a CT-based navigation system from July 2010 to September 2012. All the operations were performed by a single surgeon using a subvastus approach and the same posterior cruciate ligament substituting type (PS type) of prosthesis (Genesis II™ total knee system, Smith & Nephew, Memphis, TN). The proximal tibia osteotomy and the distal femur osteotomy were set on the navigation system perpendicular to the mechanical axis in the coronal plane with 3° tibial posterior inclination in the sagittal plane. The coronal plane ligament imbalance was corrected until the gap imbalance was fewer than 2 mm. This gap balance was checked using a ligament balancer (Smith & Nephew) at 80 N in medial and lateral compartment of the knee. The navigation system was used to measure the flexion gap with the CAS ligament balancer (Depuy, Warsaw, IN, USA) at 90° knee flexion. The amount of external rotation on femoral osteotomy was adjusted by the navigation system with a balanced gap technique. The patella was resurfaced and a lateral release was not performed. Tibial A-P axis of the tibial tray was placed parallel to Akagi's line. We measured each kinematics pattern immediately after capsule incision (preoperative knee kinematics) and after implantation (postoperative knee kinematics) in TKA. Subjects were divided into two groups based on kinematics patterns: a medial pivot group (group M) and a non-medial pivot group (group N). A chi-square test was used for statistical analysis. P values less than 0.05 were considered significant.


The Bone & Joint Journal
Vol. 97-B, Issue 8 | Pages 1090 - 1095
1 Aug 2015
Urita A Funakoshi T Suenaga N Oizumi N Iwasaki N

This pilot study reports the clinical outcomes of a combination of partial subscapularis tendon transfer and small-head hemiarthroplasty in patients with rotatator cuff arthropathy. A total of 30 patients (30 shoulders; eight men and 22 women) with a mean age of 74 years (55 to 84) were assessed at a mean follow-up of 31 months (24 to 60). The inclusion criteria were painful cuff tear arthropathy with normal deltoid function and a non-degenerative subscapularis muscle and tendon and a preserved teres minor.

Outcome was assessed using the University of California Los Angeles score, the Japanese Orthopaedic Association score, and the Oxford Shoulder Score. Radiographic measurements included the centre of rotation distance and the length of the deltoid.

All clinical scores were significantly improved post-operatively. The active flexion and external rotation improved significantly at the most recent follow-up (p < 0.035). Although the mean centre of rotation distance changed significantly (p < 0.001), the mean length of the deltoid did not change significantly from the pre-operative value (p = 0.29). The change in the length of the deltoid with < 100° flexion was significantly less than that with > 100° (p < 0.001).

Progressive erosion of the glenoid was seen in four patients. No patient required revision or further surgery.

A combination of partial subscapularis tendon transfer and small-head hemiarthroplasty effectively restored function and relieved pain in patients with rotator cuff arthropathy.

Cite this article: 2015;97-B:1090–5.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 337 - 337
1 Jul 2014
Onodera T Yamashita T Iwasaki N Sasazawa F
Full Access

Summary Statement

The deletion of gangliosides enhanced OA development by elevating MMP-13 and ADAMTS-5 expression and accelerating chondrocyte apoptosis. Gangliosides possibly play suppressive roles in IL-1α-induced inflammatory signaling cascades.

Introduction

We have previously reported that glycosphingolipids (GSLs) play chondroprotective roles in the cartilage degradation process [1]. Gangliosides, one of the series of GSLs, are known to be important in intercellular signal transduction and cell-to-cell recognition [2]. Therefore, we hypothesised that gangliosides are important in cartilage metabolisms among the GSLs species. The purpose of this study was to determine the functional role of gangliosides in the development of OA in murine models.