header advert
Results 1 - 20 of 31
Results per page:
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_9 | Pages 95 - 95
1 May 2017
Gonzalez A Uçkay I Hoffmeyer P Lübbeke A
Full Access

Background

Smoking has been associated with poor tissue oxygenation and vascularisation, predisposing smokers to a higher risk for postsurgical infections. The aim of this study was to estimate and compare the incidence of prosthetic joint infection (PJI) following primary total joint arthroplasty (TJA) according to smoking status.

Methods

A prospective hospital-registry based cohort was used including all primary total knee and hip arthroplasties performed between 03/1996 and 12/2013 and following them until 06/2014. Smoking status at time of surgery was classified in never, former and current smoker. Incidence rates and incidence rate ratios (IRR) for PJI according to smoking status were assessed within the first year and over the whole study period. Adjusted IRRs were obtained using cox regression model. Adjustment was performed for the following baseline characteristics: age, sex, BMI, ASA score, diabetes, arthroplasty site (knee or hip) and surgery duration.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 27 - 27
1 Dec 2013
Charbonnier C Chague S Ponzoni M Bernardoni M Hoffmeyer P Christofilopoulos P
Full Access

Introduction

Conventional pre-operative planning for total hip arthroplasty mostly relies on the patient radiologic anatomy for the positioning and choice of implants. This kind of planning essentially remains a static approach since dynamic aspects such as the joint kinematics are not taken into account. Hence, clinicians are not able to fully consider the evolving behavior of the prosthetic joint that may lead to implant failures. In fact, kinematics plays an important role since some movement may create conflicts within the prosthetic joint and even provoke dislocations. The goal of our study was to assess the relationship between acetabular implant positioning variations and resultant impingements and loss of joint congruence during daily activities. In order to obtain accurate hip joint kinematics for simulation, we performed an in-vivo study using optical motion capture and magnetic resonance imaging (MRI).

Methods

Motion capture and MRI was carried out on 4 healthy volunteers (mean age, 28 years). Motion from the subjects was acquired during routine (stand-to-sit, lie down) and specific activities (lace the shoes while seated, pick an object on the floor while seated or standing) known to be prone to implant dislocation and impingement. The hip joint kinematics was computed from the recorded markers trajectories using a validated optimized fitting algorithm (accuracy: translational error ≍ 0.5 mm, rotational error < 3°) which accounted for skin motion artifactsand patient-specific anatomical constraints (e.g. bone geometry reconstructed from MRI, hip joint center) (Fig. 1).

3D models of prosthetic hip joints (pelvis, proximal femur, cup, stem, head) were developed based on variations of acetabular cup's inclination (40°, 45°, 60°) and anteversion (0°, 15°, 30°) parameters, resulting in a total of 9 different implant configurations. Femoral anteversion remained fixed and determined as “neutral” with the stem being parallel to the posterior cortex of the femoral neck. Motion capture data of daily tasks were applied to all implant configurations.

While visualizing the prosthetic models in motion, a collision detection algorithm was used to locate abnormal contacts between both bony and prosthetic components (Fig. 2). Moreover, femoral head translations (subluxation) were computed to evaluate the joint congruence.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 29 - 29
1 Dec 2013
Charbonnier C Christofilopoulos P Chague S Schmid J Bartolone P Hoffmeyer P
Full Access

Introduction

Today, there is no clear consensus as to the amplitude of movement of the “normal hip”. Knowing the necessary joint mobility for everyday life is important to understand different pathologies and to better plan their treatments. Moreover, determining the hip range of motion (ROM) is one of the key points of its clinical examination. Unfortunately this process may lack precision because of movement of other joints around the pelvis. Our goal was to perform a preliminary study based on the coupling of MRI and optical motion capture to define precisely the necessary hip joint mobility for everyday tasks and to assess the accuracy of the hip ROM clinical exam.

Methods

MRI was carried out on 4 healthy volunteers (mean age, 28 years). A morphological analysis was performed to assess any bony abnormalities. Two motion capture sessions were conducted: one aimed at recording routine activities (stand-to-sit, lie down, lace the shoes while seated, pick an object on the floor while seated or standing) known to be painful or prone to implant failures. During the second session, a hip clinical exam was performed successively by 2 orthopedists (2 and 12 years' experience), while the motion of the subjects was simultaneously recorded (Fig.1). These sequences were captured: 1) supine: maximal flexion, maximal IR/ER with hip flexed 90°, maximal abduction; 2) seated: maximal IR/ER with hip and knee flexed 90°. A hand held goniometer was used by clinicians to measure hip angles in those different positions.

Hip joint kinematics was computed from the markers trajectories using a validated optimized fitting algorithm which accounted for skin motion artifacts (accuracy: translational error≍0.5 mm, rotational error <3°). The resulting computed motions were applied to patient-specific hip joint 3D models reconstructed from their MRI data (Fig. 2). Hip angles were determined at each point of the motion thanks to two bone coordinate systems (pelvis and femur). The orthopedist's results were compared.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLIV | Pages 96 - 96
1 Oct 2012
Dubois-Ferriere V Hoffmeyer P Assal M
Full Access

In foot and ankle surgery incorrect placement of implants, or inaccuracy in fracture reduction may remain undiscovered with the use of conventional C-arm fluoroscopy. These imperfections are often only recognized on postoperative computer tomography scans. The apparition of three dimensional (3D) mobile Imaging system has allowed to provide an intraoperative control of fracture reduction and implant placement. Three dimensional computer assisted surgery (CAS) has proven to improve accuracy in spine and pelvic surgery. We hypothesized that 3D-based CAS could improve accuracy in foot and ankle surgery.

The purpose of our study was to evaluate the feasibility and utility of a multi-dimensional surgical imaging platform with intra-operative three dimensional imaging and/or CAS in a broad array of foot and ankle traumatic and orthopaedic surgery.

Cohort study of patients where the 3D mobile imaging system was used for intraoperative 3D imaging or 3D-based CAS in foot and ankle surgery.

The imaging system used was the O-arm Surgical Imaging System and the navigation system was the Medtronic's StealthStation.

Surgical procedures were performed according to standard protocols.

In case of fractures, image acquisition was performed after reduction of the fracture. In cases of 3D-based CAS, image acquisition was performed at the surgical step before implants placement. At the end of the operations, an intraoperative 3D scan was made.

We used the O-arm Surgical Imaging system in 11 patients: intraoperative 3D scans were performed in 3 cases of percutaneus fixation of distal tibio-fibular syndesmotic disruptions; in 2 of the cases, revision of reduction and/or implant placement were needed after the intraoperative 3D scan.

Three dimensional CAS was used in 10 cases: 2 open reduction and internal fixation (ORIF) of the calcaneum, 1 subtalar fusion, 2 ankle arthrodesis, 1 retrograde drilling of an osteochondral lesion of the talus, 1 Charcot diabetic reconstruction foot and 1 intramedullary screw fixation of a fifth metatarsal fracture. The guidance was used essentially for screw placement, except in the retrograde drilling of an osteochondral lesion where the guidance was used to navigate the drill tool. Intraoperative 3D imaging showed a good accuracy in implant placement with no need to revision of implants.

We report a preliminary case series with use of the O-arm Surgical Imaging System in the field of foot and ankle surgery. This system has been used either as intraoperative 3D imaging control or for 3D-based CAS. In our series, the 3D computer assisted navigation has been very useful in the placement of implants and has shown that guidance of implants is feasible in foot and ankle surgery. Intraoperative 3D imaging could confirm the accuracy of the system as no revisions were needed. Using the O-arm as intraoperative 3D imaging was also beneficial because it allowed todemonstrate intraoperative malreduction or malposition of implants (which were repositioned immediately). Intraoperative 3D imaging system showed very promising preliminary results in foot and ankle surgery. There is no doubt that intraoperative use of 3D imaging will become a standard of care. The exact indications need however to be defined with further studies.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 64 - 64
1 Sep 2012
Holzer N Salvo D Marijnissen AK Che Ahmad A Sera E Hoffmeyer P Wolff AL Assal M
Full Access

Introduction

Currently, a validate scale of ankle osteoarthritis (OA) is not available and different classifications have been used, making comparisons between studies difficult. In other joints as the hip and knee, the Kellgren-Lawrence (K&L) scale, chosen as reference by the World Health Organizations is widely used to characterize OA. It consists of a physician based assessment of 3 radiological features: osteophyte formation, joint space narrowing and bone end sclerosis described as follows: grade 0: normal joint; grade 1: minute osteophytes of doubtfull significance; grade 2: definite osteophytes; grade 3: moderate diminution of joint space; grade 4: joint space greatly impaired, subchondral sclerosis. Until now, the K&L scale has never been validated in the ankle. Our objective was to assess the usefulness of the K&L scale for the ankle joint, by determining its reliability and by comparing it to functional scores and to computerized minimal joint space width (minJSW) and sclerosis measurements. Additionally we propose an atlas of standardized radiographs for each of the K&L grades in the ankle.

Methods

73 patients 10 to 20 years post ankle ORIF were examined. Bilateral ankle radiographs were taken. Four physicians independently assessed the K&L grades and evaluated tibial and talar sclerosis on anteroposterior radiographs. Functional outcome was assessed with the AOFAS Hindfoot score. Bone density and minJSW were measured using a previously validated Ankle Image Digital Analysis software (AIDA).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 56 - 56
1 Sep 2012
Lübbeke A Salvo D Holzer N Hoffmeyer P Assal M
Full Access

Introduction

Among patients with ankle osteoarthritis (OA) a post-traumatic origin is much more frequent than among those with knee or hip OA. However, long-term studies evaluating risk factors for the development of OA after ankle fractures are lacking.

Methods

Retrospective cohort study including consecutive patients operated at our institution between 1/1988 and 12/1997 for malleolar fractures treated with open-reduction and internal fixation (ORIF). Ankle OA was independently assessed by two reviewers on standardized radiographs using the Kellgren and Lawrence (K&L) scale. Multivariate logistic regression analysis was performed to determine predictors for OA.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 363 - 363
1 Sep 2012
Lübbeke A Garavaglia G Roussos C Barea C Peter R Hoffmeyer P
Full Access

Introduction

A recent review of the literature on metal-on-metal total hip arthroplasties (THA) revealed the lack of comparative clinical studies with a sufficient sample size and the inclusion of patient-reported outcomes as well as patient activity levels.

Methods

We conducted a prospective cohort study including all metal-on-metal and conventional polyethylene (PE)-ceramic THAs with an uncemented cup (Morscher press-fit cup), a 28mm head and operated upon via a lateral approach at our University hospital between 1/1999 and 12/2008. Only THAs for primary osteoarthritis were included. The study population is part of the Geneva Hip Arthroplasty Registry, a prospective cohort followed since 1996. The following outcomes were compared between the two groups (metal-on-metal=group 1 vs. PE-ceramic bearing=group 2): (1) Complication rates with respect to infection, dislocation and revision, (2) Radiographic outcomes (presence of linear or focal femoral osteolysis, loosening), and (3) Clinical outcomes (Harris Hip score increase, SF-12, activity and patient satisfaction evaluation, presence of groin pain). Patients operated between 1/1999 and 12/2004 were evaluated five years postoperatively by an independent assessor. Cox regression analysis was used to compare incidence rates while adjusting for differences in baseline characteristics.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 177 - 177
1 Sep 2012
Christofilopoulos P Lübbeke A Berton C Lädermann A Berli M Roussos C Peter R Hoffmeyer P
Full Access

Introduction

Large diameter metal on metal cups have been used in total hip arthroplasty advocating superior results with respect to dislocation rates, range of motion and long term survival. The Durom cup used as part of the Durom hip resurfacing system has been incriminated with poor short term results sometimes correlated to incorrect positioning of either the femoral or acetabular component. Our objective was to evaluate short term results of the Durom cup used in conjunction with standard stems.

Methods

We prospectively followed all patients with a large diameter metal-on-metal articulation (Durom) and a standard stem operated upon between 9/2004 and 9/2008. Patients were seen at follow-up for a clinical (Harris hip score=HHS, UCLA scale and patient satisfaction), radiographic and questionnaire assessment.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 202 - 202
1 Sep 2012
Roussos C Lübbeke A Koehnlein W Hoffmeyer P
Full Access

Introduction

Orthopaedic surgeons are frequently asked to perform a revision total hip arthroplasty (THA) in patients over 80 years of age. Our objective was to evaluate the outcomes after revision THA in patients 80 years or older and compare them to a cohort of patients less than 80 years of age.

Methods

We reviewed all revision THAs performed in our institution from 3/1996 to 12/2008. We compared intra- and post-operative complications (medical and orthopaedic), mortality, clinical outcomes and patient satisfaction between the two age groups. Peri-operative information and complications were collected prospectively, and clinical outcome data were obtained both pro- and retrospectively. The Merle d'Aubigné score, Harris Hip score, general health (SF-12) and patient satisfaction (visual analog scale) were assessed.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 538 - 538
1 Nov 2011
Gérard R Unno-Veith F Hoffmeyer P Fasel J Assal M
Full Access

Purpose of the study: Stiffness of the ankle joint is a common complication after fracture, surgical repair, or total ankle arthroplasty. Dorsiflexion is generally the most limited movement. A few older papers have focused on this common problem in orthopaedic surgery of the ankle joint but have been controversial. The purpose of this anatomy study was to evaluate the efficacy and quantify the impact of releasing the collateral ligaments of the ankle joint on dorsiflexion stiffness.

Material and methods: The two main ankle ligaments implicated in this type of stiffness, the deep bundle of the posterior tibiotalar ligament (dPTTaL) and the posterior talofibular ligament (PTaFL), were studied. We dissected 16 talocrural joints on fresh cadavers and measured with electronic goniometry coupled with electronic dynamometry their movement in dorsiflexion after section of the dPTTaL in the first group and after section of the PTaFL in the second.

Results: The results showed a significant difference (p< 0.0003) between the two populations of ankles. Section of the dPTTaL was more effective against dorsiflexion stiffness than section of the PTaFL, even though the overall benefit in dorsiflexion was less than 10° (mean 7.45 versus 3.45). Combined section of the two ligaments did not provide a statistically significant improvement in the gain in dorsiflextion (p=0.88) compared with isolated section of the two ligaments.

Discussion: If limitation of active and passive dorsiflexion persists after classical release or lengthening of the posterior periarticular tendons of the ankle joint, or after gastrocnemius lengthening, our results show that the following surgical step could be meticulous release of the dPTTaL.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 207 - 208
1 May 2011
Lübbeke A Garavaglia G Barea C Roussos C Stern R Hoffmeyer P
Full Access

Background: Among patients undergoing total hip arthroplasty (THA) 24–36% are obese. The most important long-term complication is periprosthetic osteolysis. While patient activity, implant type and quality of fixation are known risk factors for osteolysis, the literature concerning obesity is sparse and controversial. Our objective was to evaluate the influence of obesity on femoral osteolysis five and ten years after primary THA with a cemented stem.

Methods: Prospective cohort study conducted between 1996 and 2003 among patients undergoing THA (uncemented cup, cemented stem, 28mm head and ceramic-polyethylene bearing surface) inserted with a third generation cementing technique. All patients were seen at either five or ten years, with information regarding BMI and activity, and with radiographic follow-up. BMI was evaluated in three and four categories (< 25, 25–29.9 (reference category), 30–34.9 and ≥35 kg/m2). Activity was assessed using the University of California, Los Angeles (UCLA) activity scale (1–10 points). Main outcome was the radiographic assessment of femoral osteolysis. Secondary outcomes were polyethylene wear and revision for aseptic loosening.

Results: We included 503 THAs in 433 patients. Of those 241 THAs (48%) were seen at five years and 262 (52%) at ten years. Osteolytic lesions were identified in forty-four cases, twenty-four in 181 normal weight patients (13.3%), eleven in 205 overweight (5.4%), seven in ninety-six obese class I (7.3%), and two in twenty-one obese class II patients (9.5%). Activity was highest in normal weight patients (mean UCLA score 5.5, ±2.0) and lowest in patients obese class II (mean UCLA score 4.8, ±1.7). Univariate as well as multivariate logistic regression analysis adjusting for activity, cementing quality, age, and sex did not show an increased risk of osteolysis in obese compared to overweight patients (adjusted OR 1.4, 95% CI 0.6; 3.7). A significantly higher risk was found in normal weight patients (adjusted OR 2.6, 95% CI 1.2; 5.7). Total mean polyethylene wear was significantly lower in obese compared to normal/overweight patients (p=0.024). Revision for aseptic loosening of the stem was necessary in 4 patients (3 normal weight patients and 1 overweight patient).

Conclusions: We did not find an increased risk for femoral osteolysis or revision for aseptic loosening in obese patients five and ten years after primary THA with a cemented stem.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 139 - 139
1 May 2011
Abrassart S Hoffmeyer P
Full Access

Purpose: We aimed to provide an anatomical basis for surgical techniques in rotator cuff reinsertion. The purpose of this study was to investigate the 3-dimensional trabecular bone mineral density (BMD) in the humeral head bone and determine areas of low density. Limited information exists for humeral head to understand its mechanical behaviour.

Materials and Methods: 15 unpaired fresh humeral heads were harvested and frozen. The mean age was 75 years old. All abnormal bones underlying fractures, major arthrosis or surgical interventions were excluded from the study All the heads were scanned using a three-dimensional HR-pQCT system providing 80 microns slices nominal resolution. Manually outlining of the contours of cancellous bone was done in different areas: lesser tuberosity, greater tuberosity, articular part and centre. The parameters included in the analysis were: bone volume density (BV/TV, Trabecular thickness (tb.Th)(mm), Trabecularseparation(TB.Sp)(mm), Trabecular number(TB.N. (1/mm)

Results: The average density of the lesser tuberosity is the highest of the whole head (BV/TV= 0,228). The centre of the head is devoided of large trabeculae with a very low density (BV/TV =0,1). The greater tuberosity is rich in thin trabeculae (Tb Th = 0,265) separated by large spaces (1,5). The articular part presents the higher density (BV/TV =0,3).

Conclusions: Emphasis has traditionally been placed on cortical bone as quality predictor due to its stiffness for achieving primary stabilisation. However screws and anchors are mainly in contact with cancellous part of bone, and mechanical characteristics of cancellous bone also influence the load-bearing capacity of implant –bone union This studies is interesting in showing areas of poor cancellous bone quality and may help to improve surgical techniques.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_II | Pages 123 - 123
1 May 2011
Salvo D Holzer N Lübbeke A Hoffmeyer P Assal M
Full Access

Introduction: An ankle fracture represents the most frequent osseous injury in both the elderly and non-elderly population. To date, only a limited number of retrospective studies have addressed medium-term outcome following ankle Open Reduction and Internal Fixation (ORIF). The purpose of this study was to assess residual pain and functional outcome 10 to 20 years after operative treatment of ankle fractures and to evaluate the incidence of symptomatic and radiographic ankle osteoarthritis (OA).

Methods: We designed a retrospective study including all consecutive patients who underwent ankle ORIF between January 1988 and December 1997 in a University Hospital setting. Pilon and talus fracture as well as pediatric patients were excluded. Patients were seen by two senior residents 10–20 years after their index surgery. Residual pain was measured using the Visual Analog pain Scale. Function and general health status were assessed using the Olerud and Molander Ankle Score, the American Orthopaedic Foot and Ankle Society (AOFAS) hindfoot score and the 12-item short-form health survey (SF-12). Ankle OA on standard radiographs was scored according to the revised Kellgren and Lawrence (K& L) scale.

Results: 374 patients (56% men) underwent ankle surgery during the defined period. 10% of the patients had a Weber A fracture, 57% a Weber B and 33% a Weber C fracture. Mean age at the time of operation was 42.9 years (+/− 17.1; range 16–86 years). 10–20 years after surgery, 47 patients had died, 126 had left the country and were lost to follow-up, 99 did not respond or refused to participate, and 102 patients were seen at the follow-up visit. These patients did not differ in terms of age, gender distribution, BMI and type of fracture from those who were not seen. The mean duration of follow up was 17.3 years (+/− 3.3). Advanced radiographic OA (K& L grade 3 and 4) was present in 34.3 % of the patients. Symptomatic OA was reported by 34.3 % of the patients (AOFAS pain score < 40). Both clinically symptomatic and radiographic ankle OA was found in 18 patients (17.6%). Function was good in 85% of the cases (total AOFAS hindfoot score between 80 and 100 points; mean total AOFAS hindfoot score 89.9, +/−14.6). The mean Olerud and Molander ankle score was 86.5 (+/−18.7). The general health status (SF-12) was similar to representative values of the general population with a similar mean age.

Conclusion: 10–20 years after operative treatment of an ankle fracture, the incidence of advanced radiographic post-traumatic ankle OA was 35%, symptomatic OA was present in one third of the patients and about one fifth had both. The majority of the patients reported good function.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 525 - 525
1 Oct 2010
Lübbeke A Barea C Garavaglia G Hoffmeyer P Peter R Roussos C
Full Access

Objective: The Morscher press-fit cup is a cementless, porous-coated acetabular component. The objective of this study was to assess clinical and radiological outcomes, patient satisfaction and complications at 10 years.

Methods: Prospective cohort study including all consecutive primary THAs with the Morscher cup operated by multiple surgeons of a University hospital between March 1996 and April 1998. Patients were evaluated at 120 months (±7.2 months) with clinical and radiological follow-up, patient satisfaction and questionnaire assessment, using the Harris Hip Score (HHS), WOMAC and SF-12. Follow-up examination was done by two physicians who had not performed the operations.

Results: 421 THAs were performed in 389 patients (54.6% women; mean age 69.3, range 28–98). In 80% the diagnosis was primary osteoarthritis. All stems were cemented except for 18 patients (4.3%). One-hundred-twenty-two patients (29.0%) had died, 27 (6.4%) were lost-to follow-up, 24 (5.7%) were unable to attend because of poor general health and 27 (6.4%) refused, thus leaving 221 hips, for which 176 x-rays were available.

None of the patients required cup revision for aseptic loosening. Complications included 12 dislocations and 3 deep infections resulting in 2 total revisions. In 3 patients the stem was revised for aseptic loosening at a mean of 63 months. At 10-years the survivorship was 98.6% (95% CI 96.7; 99.4) with endpoint revision for any cause.

Mean total wear was 0.89 mm (±0.5). 32 cups (18.8%) with a cup inclination > 45° had a mean wear of 1.06 mm (±0.5), whereas 138 cups (81.2%) with inclination < 45° had a mean wear of 0.86 mm (±0.5), p=0.036. In 16 cases osteolytic defects around the stem were present. The outcome scores at 10 years were: HHS 85.9 (±14.1), WOMAC pain 70.7 (±24.7), WOMAC function 68.8 (±24.5), SF-12 physical score 40.3 (±9.2) and mental score 47.0 (±10.4). Ninety-four percent of the patients were satisfied or very satisfied.

Conclusions: The Morscher acetabular replacement cup provides excellent results at 10 years. None of the patients had to be revised for aseptic loosening of the cup, patient satisfaction was high, and clinical results were very good.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 543 - 543
1 Oct 2010
Abrassart S Hoffmeyer P Peter R Stern R
Full Access

Introduction: Early mortality associated with unstable pelvic ring injuries is often secondary to continuous pelvic bleeding. Hemostatic measures such as pelvic binders or external fixation may help to control low pressure bleeding from lacerated veins or broad fracture surfaces, while control of high pressure arterial bleeding may require embolization.

Purpose: Evaluate our experience with the control of hemorrhagic shock associated with pelvic ring injuries during initial patient management.

Methods: From January 2003 until December 2006, all [105] patients admitted to our level I trauma center with a pelvic or an acetabular fracture were prospectively entered into our polytrauma data base. Of 105 patients, 67 were classified with a type B or C pelvic fracture. All these patients received a pelvic strap belt by the paramedic team at the scene of the accident. Pelvic fractures were diagnosed on the initial anteroposterior pelvic radiograph and computed tomography. From this initial group of 67 patients, we identified 38 as unstable requiring blood transfusion and intensive care monitoring. The results and survival rate were evaluated according to the initial sequence of surgical procedures and the patients were divided into 3 groups, X,Y, and Z Follow-up physical examination and radiographs was performed for all survivors at an average of 10 months post-injury (range, 6 months to 3 years).

Results: The average age of the 38 patients was 38.6 years (range, 24–51 years) and their average ISS was 53 (range 21–75).All were injured in a high velocity motor vehicle accident or a fall from a height. The patients were managed in the emergency department by a multidisciplinary team according A.T.L.S. guidelines. Of the 38 patients, five died shortly after arrival in the emergency department despite resuscitation efforts. Within the first 24 hours, pelvic stabilization was performed in 27 patients with either an anterior external fixator frame (n=13), pelvic clamp (n=11) or primary open reduction internal fixation (n=3). In group X, of 19 patients initially treated with external fixation and eventual arterial embolization without laparotomy, 18 (94 %) survived. In group Y, there were 8 patients treated by external fixation, eventual arterial embolization and laparotomy, and 7 (87 %) survived. In group Z, all 6 patients in whom a scratch laparotomy with packing prior to any skeletal fixation was attempted,no patient survived ! All survivors underwent definitive open reduction and plate and screw fixation, with an average ICU stay of 10 days (3–15).

Conclusion: This study shows that optimal control of bleeding associated with pelvic ring injuries is achieved by initial skeletal fixation prior to any other surgical procedures. Immediate laparotomy was associated with a high rate of intraoperative death due to the failure to control bleeding.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 524 - 525
1 Oct 2010
Lübbeke A Hoffmeyer P Perneger T Suvà D
Full Access

Objective: Dislocation is a well known complication after total hip arthroplasty (THA), and the second cause of revision surgery. Our objective was to assess the effect of a pre-operative patient education session on the occurrence of hip dislocation within 6 months after primary THA.

Methods: Between 1998 and 2007 we conducted a prospective cohort study at the University Hospital Department of Orthopaedic Surgery including all primary THAs performed via a transgluteal approach and with use of a 28mm diameter head. The preoperative education session was introduced in June 2002 and included advice on muscle strengthening exercises and postoperative restrictions of range of motion as means of preventing dislocation. Main outcome was the incidence of dislocation within 6 months of surgery. The following potentially confounding factors were assessed: age, sex, body mass index, number of co-morbidities, presence of a neurological disorder, history of alcohol abuse, American Society of Anaesthesiologists (ASA) score, diagnosis (primary or secondary osteoarthritis), previous surgery of the hip, surgeon experience, preoperative functional status, pain level, and motion (Harris Hip Score), preoperative general health status (SF-12), and private or public health care insurance (as proxy for socioeconomic status). Multivariable logistic regression was used for adjustment.

Results: 597 patients who underwent 656 THAs between June 2002 and June 2007 participated in the education session, while 1641 patients who underwent 1945 procedures did not. Forty-six dislocations occurred over the study period, 5 (0.8%) in participants and 41 (2.1%) in non-participants (risk difference 1.3%; 95% CI 0.4; 2.3), with the time interval between surgery and dislocation being significantly shorter among participants (0.2 vs. 1.2 months, p=0.016). Preoperative counselling of 77 patients allowed for preventing one dislocation (number needed to treat). Non-participants had a 2.8 times higher risk of dislocation than participants (unadjusted odds ratio 2.80, 95% CI 1.10; 7.13). Adjustment for age, sex, co-morbidities and prior surgery did not change the results (adjusted odds ratio 2.79, 95% CI 1.09; 7.15).

Conclusion: Preoperative patient education reduced the dislocation risk within 6 months after THA, and particularly after the patient had returned home. Other peri-operative benefits from patient education have been reported and should be considered in a cost-effectiveness analysis.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 340 - 340
1 May 2010
Abrassart S Hoffmeyer P
Full Access

Objectives: The aim of this study was to quantify bone microarchitecture within the glenoid fossa of the scapula.

High-resolution micro-computed tomography ([mu]CT) imaging have been instrumental in providing true quantitative and qualitative three-dimensional data on baseline bone morphology

Materials and Methods: 25 fresh-frozen human cadaveric shoulders were analysed. The mean age of the specimens was 66 years. All scapulae were inspected for normal anatomic landmarks.

The glenoids were cut at the glenoid neck and at the base of the coracoid process.

The total, trabecular, and cortical BMDs of the 5 regions of the glenoids were determined by use of peripheral quantitative computed tomography (pQCT) (Xtrem Ct;Scanco, Zurich, Ch) Each glenoid was fixed horizontally in a custom-made jig, and axial pQCT scans (pixel size,1536/1536; slice thickness 80 microns), perpendicular to the articular surface, were obtained at the level of each area. From the resulting binarized three-dimensional reconstruction, Scanco software was used to calculate the bone volume per tissue volume; mean trabecular separation; mean trabecular number, connectivity density.

Results: The total BMD of the posterior and superior glenoid were significantly higher than those of the anterior and inferior glenoid. Trabecular BMD of the posterior glenoid was significantly higher than that of the anterior glenoid, and cortical BMD of the superior glenoid was significantly higher than that of the inferior glenoid.

The mean total BMD in different regions of 20 glenoid specimens ranged from 0,243 to 0,489 g/cm2. The center of the glenoid was surprisingly poor in trabecular structures as we found a bony gap at 8 mm of distance from the articular surface.

Conclusions and clinical relevance: Although the specimen age was quite high in our material, we believe aging does not affect our study as shoulders prosthesis are generally performed on old patients.

In the future, component design should use areas of stronger subchondral bone. Posterior and superior bone area could be another alternative for fixation in decreasing glenoid-loosening rates. As the inferior center of the glenoid is an area devoided of trabecular bone, center-keel design component doesn’t seem to be the best choice.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 287 - 287
1 Jul 2008
MESSERLI G SADRI H SCHOLLER J SONNEY F PETER R HOFFMEYER P
Full Access

Purpose of the study: This was an analysis of long-term outcome of 260 consecutive total hip arthroplasty (THA) procedures performed with a press-fit CLS-Spotorno cup. This easy-to-position cup preserves bone stock if revision should be needed.

Material and methods: From January 1990 to December 1994, 260 THA were implanted with a CLS-Spotorno cup in 221 patients. The clinical and radiological outcome was assessed with minimal ten years follow-up. Mean age at operation was 63 years (range 26–82 years). Sixty eight patients (68 hips) died before ten years follow-up. Five patients (five hips) could not be transported for review and four patients (four hips) were lost to follow-up. This study thus concerned 183 Spotorno cups (70.3%) in 144 patients (65.1%) who were reviewed clinically at 120–166 months follow-up. One hundred twenty-five patients agreed to undergo a radiological work-up. X-rays were analyzed by several independent operators. Two hundred sixty prostheses were implanted by two senior surgeons using the transgluteal approach. The Harris score and the De-Lee-Charnley radiological assessment as well as the Kaplan-Meier survival curve were determined.

Results: Seven cups were revised (3.8%): three because of aseptic loosening, two during stem revision because of polyethylene wear, and two for recurrent dislocation. Radiographically, four cups (2.2%) had migrated and there was a lucent line adjacent to the cup in at least one of the three De-Lee-Charnley zones for 23 cups (12.5%). There were no cup wing fractures. The mean Harris score for 144 patients (183 hips) was 90 points (range 37–100) at last follow-up. Outcome was considered excellent for 123 hips (67%), good for 34 (18.5%), fair for 20 and mediocre for five. The Kaplan-Meier 10-year survival with revision as the end point was 99% (CI: 94.8–99.8%).

Discussion: The 10-year survival of CLS-Spotorno cups is excellent with a low rate of revision. These results can be tempered by the radiological findings, although the lucent lines were already visible on the 12-month x-rays with no visible progression.

Conclusion: This cup provides excellent long-term results with a survival curve comparable to other press-fit cups. It is easy to position and revise.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 241 - 241
1 Jul 2008
SADRI H HOFFMEYER P
Full Access

Purpose of the study: Coxofemoral conflicts can sometimes lead to early degenerative disease in young patients. Open surgery for surgical dislocation with joint cleaning had provided promising short- and mid-term results. Arthroscopy of the hip joint is a less invasive alternative. The purpose of this work was to compare prospectively the outcome achieved with open surgical or arthroscopic treatment of coxofemoral conflicts after a minimum follow-up of two years.

Material and methods: Sixty-three patients, mean age 30 years (range 19–54) with arthroMRI-proven coxofemoral conflict were evaluated two years after treatment. Surgical dislocation was used for 31 patients and arthroscopy for 32. Clinical outcome was assessed on the basis of WOMAC scores noted preoperatively, postoperatively and at two years follow-up. Complications were noted.

Results: Results were similar in the two groups at two years: preoperative WOMAC score: 65/100 (41–95) pour open dislocation, 57/100 (15–96) for arthroscopy; postoperative WOMAC score at two years: 79/100 (41–99) for open dislocation, 84/100 (50–99) for arthroscopy. The rate of patient satisfaction was similar: (open dislocation: 75% and arthroscopy: 82%). Complications: open dislocation : 3 case of POA including 1 Brooker stage III and one 1 case of ossifying myositis of the thigh; arthroscopy: 2 case of hematoma (spontaneous resolution) and 1 case of transient irritation (48 h) of the lateral femoral cutaneous nerve. Surgical revisions at two years: open dislocation: one total hip arthroplasty at 15 months and one resection of ossification (POA) at 15 months; arthroscopy: two total hip arthroplasties at 5 and 15 months.

Discussion: The results obtained with the two methods are encouraging at two years. A satisfaction rate of 80% can be expected.

Conclusion: Arthroscopy appears to be the more advantageous alternative for young patients since it is less invasive and provides similar results at two years.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 242 - 242
1 Jul 2008
SADRI H HOFFMEYER P
Full Access

Purpose of the study: Coxofemoral conflicts can sometimes lead to early degenerative disease in young patients. Hip arthroscopy is a less invasive alternative which can remove all of the coxofemoral conflicts. Like open surgery, a purely arthroscopic technique enables all the necessary corrections, even involving the rim. Arthroscopy has provides promising short- and mid-term results. The purpose of this work was to present the surgical technique, its drawbacks and complications, and present suggestions for improvement.

Material and methods: Fifty-one patients, mean age 31 years (range 15–54 years) underwent purely arthroscopic treatment of coxofemoral conflicts between February 2001 and November 2003. Prospective follow-up was at least six months. The type of conflict and the corresponding corrections were noted. The Pre- and postoperative WOMAC scores were used for clinical assessment. Complications were noted as well as means for avoiding them.

Results: The operative technique, the potential dangers, and suggestions for successful arthroscopy are presented. The clinical outcome with at least six months follow-up was: hip R/L: 21/31. Head and acetabular correction: 46 cases. Head correction alone (head/neck offset): 5 cases. Preoperative WOMAC score: 59/100 (15–99). Postoperative WOMAC score: 85/100 (49–99). Complications: spontaneously resolutive hematoma (n=2), transient (48h) irritation of the lateral femoral cutaneous nerve (n=1).

Discussion: Purely arthroscopic correction of a coxofemoral conflict is as safe as the open surgical technique. The arthroscopic method provides very promising short- and mid-term results with no major complications. The lower morbidity with this technique enables ambulatory treatment with shorter recovery time.