Vol. 96-B, Issue SUPP_17 | Pages 9 - 9
1 Nov 2014
Walker R Chang N Dartnell J Nash W Abbasian A Singh S Jones I
Full Access

Introduction:

In 2009 the Smart Toe implant was introduced as an option for lesser toe fusion in our department. The Smart Toe is an intramedullary device made from Nitinol, an alloy that can change shape with a change of temperature, expanding within the intramedullary canals of the proximal and middle phalanx to achieve fixation. The advantages of the Smart Toe are that patients are spared 6 weeks with K-wires protruding from their toes and there is no need for wire removal. We conducted a retrospective review of radiographic and clinical outcomes to assess the performance of this implant.

Methods:

We present a consecutive series of 192 toe fusions using the Smart Toe implant in 86 patients, between January 2009 and November 2013. All radiographs and case notes were reviewed to assess for radiological fusion, satisfactory clinical outcome and complications.