Bone & Joint Research
Vol. 8, Issue 6 | Pages 232 - 245
1 Jun 2019
Lu C Zhang T Reisdorf RL Amadio PC An K Moran SL Gingery A Zhao C

Objectives

Re-rupture is common after primary flexor tendon repair. Characterization of the biological changes in the ruptured tendon stumps would be helpful, not only to understand the biological responses to the failed tendon repair, but also to investigate if the tendon stumps could be used as a recycling biomaterial for tendon regeneration in the secondary grafting surgery.

Methods

A canine flexor tendon repair and failure model was used. Following six weeks of repair failure, the tendon stumps were analyzed and characterized as isolated tendon-derived stem cells (TDSCs).


Bone & Joint Research
Vol. 5, Issue 10 | Pages 453 - 460
1 Oct 2016
Ernstbrunner L Werthel J Hatta T Thoreson AR Resch H An K Moroder P

Objectives

The bony shoulder stability ratio (BSSR) allows for quantification of the bony stabilisers in vivo. We aimed to biomechanically validate the BSSR, determine whether joint incongruence affects the stability ratio (SR) of a shoulder model, and determine the correct parameters (glenoid concavity versus humeral head radius) for calculation of the BSSR in vivo.

Methods

Four polyethylene balls (radii: 19.1 mm to 38.1 mm) were used to mould four fitting sockets in four different depths (3.2 mm to 19.1mm). The SR was measured in biomechanical congruent and incongruent experimental series. The experimental SR of a congruent system was compared with the calculated SR based on the BSSR approach. Differences in SR between congruent and incongruent experimental conditions were quantified. Finally, the experimental SR was compared with either calculated SR based on the socket concavity or plastic ball radius.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 62 - 62
1 Jul 2014
Abdel M Morrey M Barlowv J Grill D Kolbert C An K Steinmann S Morrey B Sanchez-Sotelo J
Full Access

Summary

Based upon genetic analysis, decorin is an exciting pharmacologic agent of potential anti-fibrogenic effect on arthrofibrosis in our animal model.

Introduction

While the pathophysiology of arthrofibrosis is not fully understood, some anti-fibrotic molecules such as decorin could potentially be used for the prevention or treatment of joint stiffness. The goal of this study was to determine whether intra-articular administration of decorin influences the expression of genes involved in the fibrotic cascade ultimately leading to less contracture in an animal model.


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 263 - 263
1 Jul 2014
Imai K Ikoma K Gay R Hirano T Ozasa Y Chen Q An K Zhao C
Full Access

Summary Statement

ASTM therapy is commonly used to treat Achilles tendinopaty. However, there was no report to evaluate the biomechanical effects, especially the dynamic viscoelasticity. We have shown that ASTM treatment was biomechanically useful for chronic Achilles tendinopathy in an animal model.

Introduction

Achilles tendinopathy is a common chronic overuse injury. Because Achilles tendon overuse injury takes place in sports and there has been a general increase in the popularity of sports activities, the number and incidence of Achilles tendon overuse injury has increased. Augmented Soft Tissue Mobilization (ASTM) therapy is a modification of traditional soft tissue mobilization and has been used to treat a variety of musculoskeletal disorders. ASTM therapy is thought to promote collagen fiber realignment and hasten tendon repair. It might also change the biomechanical behavior of the injured tendon, especially the dynamic viscoelasticity. The purpose of this study is to evaluate the effect of ASTM therapy in a rabbit model of Achilles tendinopathy by quantifying dynamic biomechanical properties and histologic features.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 154 - 155
1 Mar 2006
Papagelopoulos P Hokari Y Currier B An K
Full Access

The purpose of this study is the biomechanical comparison of five C1 – C2 posterior arthrodesis techniques. Ten adult human cadaveric upper cervical spine specimens were sectioned at the C3 level. The occiput and C3 vertebra were potted in PMMA. The specimens were tested intact; after destabilizing with odontoid transection and sectioning of the transverse and capsular ligaments; and after stabilization with Brooks-Jenkins cable fixation, Brooks-Jenkins with unilateral transarticular screw, Gallie posterior wire construct with unilateral transarticular screw, Brooks-Jenkins with bilateral screws, and Gallie with bilateral screws. Data were analysed with special attention paid to the motion at C1 – C2. The neutral zone (NZ) and range of motion (ROM) were measured in the main plane of each motion, as well as in coupled planes. In flexion / extension and lateral bending, the ROM and NZ increased significantly in the injured specimens as compared to the intact (p< 0.0001).

In axial torsion, there was no significant difference between the intact and injured spines at C1 – C2 level. In the different fixation systems, the ROM and NZ were significantly lower than in injured and intact spines in all motions (p< 0.01), except the lateral bending in intact spine. Among the 5 instrumentations, the NZ and ROM in flexion / extension for the Gallie construct with one screw were significantly higher than for the Brooks-Jenkins construct with one or two screws (p< 0.05). In axial torsion, the Gallie construct with one screw displayed a larger NZ and ROM than any of the other four constructs (p< 0.05).


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 252 - 252
1 Mar 2004
Halder A Zobitz M An K Neumann W
Full Access

Aims: Although the glenohumeral joint is the most mobile articulation of the human body it is known to exhibit ball-and-socket-kinematics. Compression into the glenoid concavity keeps the humeral head centered. The purpose of this study was to determine the effects of joint position on glenohumeral stability through concavity-compression. Methods: Ten cadaver shoulders were tested. The glenoid was mounted horizontally onto a six-component load cell while the humerus was clamped to a vertically unconstrained slide. An x-y-stage translated the load cell with the glenoid underneath the humeral head in eight different directions. Compressive loads of twenty, forty and sixty Newtons were applied. The tests were repeated in 0, 30, 60 and 90 degrees of glenohumeral abduction with and without labrum. Translation distances and the forces resisting translation were recorded and the stability ratio calculated. Results: The average stability ratio was higher in hanging arm position than in glenohumeral abduction. With intact labrum the highest stability ratio was detected in inferior direction (59.8±7.7 percent), without labrum in superior direction (53.3±7.9 percent). In both conditions the anterior direction showed the lowest stability ratio (32.0±4.4 percent; 30.4±4.1 percent). Resection of the labrum resulted in a decrease in stability ratio of 9.6 ±1.7 percent. With increasing compressive load the stability ratio slightly decreased. Conclusions: Anterior shoulder dislocation may be facilitated by the lower stability in glenohumeral abduction and anterior direction. The labrum may not contribute as much as previously assumed to glenohumeral stability. Even moderate compressive forces are sufficient to provide stability through concavity-compression.