Kinematic alignment in total knee arthroplasty: a five-year prospective, multicentre, survivorship study



Download PDF

Abstract

Aims

The mid-term results of kinematic alignment (KA) for total knee arthroplasty (TKA) using image derived instrumentation (IDI) have not been reported in detail, and questions remain regarding ligamentous stability and revisions. This paper aims to address the following: 1) what is the distribution of alignment of KA TKAs using IDI; 2) is a TKA alignment category associated with increased risk of failure or poor patient outcomes; 3) does extending limb alignment lead to changes in soft-tissue laxity; and 4) what is the five-year survivorship and outcomes of KA TKA using IDI?

Methods

A prospective, multicentre, trial enrolled 100 patients undergoing KA TKA using IDI, with follow-up to five years. Alignment measures were conducted pre- and postoperatively to assess constitutional alignment and final implant position. Patient-reported outcome measures (PROMs) of pain and function were also included. The Australian Orthopaedic Association National Joint Arthroplasty Registry was used to assess survivorship.

Results

The postoperative HKA distribution varied from 9° varus to 11° valgus. All PROMs showed statistical improvements at one year (p < 0.001), with further improvements at five years for Knee Osteoarthritis Outcome Score symptoms (p = 0.041) and Forgotten Joint Score (p = 0.011). Correlation analysis showed no difference (p = 0.610) between the hip-knee-ankle and joint line congruence angle at one and five years. Sub-group analysis showed no difference in PROMs for patients placed within 3° of neutral compared to those placed > 3°. There were no revisions for tibial loosening; however, there were reports of a higher incidence of poor patella tracking and patellofemoral stiffness.

Conclusion

PROMs were not impacted by postoperative alignment category. Ligamentous stability was maintained at five years with joint line obliquity. There were no revisions for tibial loosening despite a significant portion of tibiae placed in varus; however, KA executed with IDI resulted in a higher than anticipated rate of patella complications.

Cite this article: Bone Jt Open 2022;3(8):656–665.

Take home message

Kinematic alignment produces good patient outcomes and stable ligament laxity at five years for a wide range of hip-knee-ankle angles and joint line obliquities.

There were no incidents of tibial loosening but a higher than anticipated rate of patella complications when performing kinematic alignment with image derived instrumentation.

Introduction

Satisfaction with the outcome of total knee arthroplasty (TKA) is highly variable, dependent on complex interactions between implant design, surgical technique, patient selection, and management of patient expectations.1-3 Recently, there has been a growing interest in alternative alignment approaches that differ from traditional mechanical TKA alignment, which relies on establishing a straight limb through the centre of the knee by perpendicular resections to the mechanical axis of the femur and tibia.4,5 In an attempt to improve patient satisfaction and outcomes, a kinematic alignment (KA) approach to the knee has been adopted by an increasing number of surgeons. The KA target has been described as correction of the arthritic deformity to the pre-arthritic or native constitutional alignment of the individual patient by co-aligning the rotational axes of the femoral, tibial, and patella components with the three kinematic axes of the knee.6-10

KA of TKA continues to be a topic of discussion due to surgeon’s differing interpretations of kinematic alignment and the mixed results, with little evidence at long-term follow-up of kinematically aligned TKAs. One method of executing a kinematically-aligned TKA was to use image derived instrumentation (IDI) (Shapematch Cutting Guides; OtisMed, USA), where the patient’s native kinematic axes and joint lines were derived from 3D scans. This technology is no longer commercially available, but experience from the design surgeon’s patient cohort has shown encouraging short-term results following kinematically aligned TKA.11,12 However, a recent meta-analysis of randomized control trials using the same kinematic technique showed minimal difference to mechanical alignment.13 The long-term evidence on non-mechanically aligned TKA stem from two sources, one from the aforementioned design surgeon reporting the ten-year survivorship,14 and the other from a retrospective analysis reporting no difference in 20-year outcomes between patients who had a mechanical postoperative alignment within 3° of neutral and those who were outside the range.15 While these studies report survivorship, an understanding of potential changes in limb and joint line obliquity over time is an area not yet explored.16 Concerns often raised with KA, such as increased risk of tibial baseplate loosening, polyethylene wear, and patella maltracking, may be a result of residual imbalance, which develops over time from non-neutral alignment.16

Therefore, this paper seeks the answer to the following research questions: 1) what is the distribution of alignment of TKAs using IDI; 2) is a TKA alignment category associated with increased risk of failure or poor patient outcomes; 3) does KA TKA lead to changes in soft tissue laxity over time due to joint line obliquity; and 4) what is the five-year survivorship and outcomes of kinematically-aligned knees using IDI? These questions are addressed at mid-term follow-up using outcomes of a prospective, multicentre cohort of patients who received kinematically aligned TKAs executed with IDI and using data from the Australian Orthopaedic Association National Joint Arthroplasty Registry (AOANJRR).

Methods

Clinical trial enrolment and follow-up methods

A prospective, multicentre trial enrolled 100 patients undergoing KA TKA between November 2010 and July 2011. The trial was conducted in accordance with the Declaration of Helsinki, and was approved by the local human research ethics committees at each participating institution (Dandenong Hospital (HREC Ref: 10050B), The Mater Hospital Pimlico (HREC Ref: MHS20100801-01, Royal Perth Hospital (HREC Ref: EC 2010/030), and St John of God (Subiaco HREC Ref: 1046), with consent collected prospectively at the preoperative visit. This trial was registered in the Australian New Zealand Clinical Trials Registry (registration no: ACTRN12610000192088) and ClinicalTrials.gov (Identifier: NCT02527161). The planned sample size was calculated on a 15-point improvement in the Knee Society Score17 reported by Howell et al,10 which represented a clinically significant improvement. Using a standard deviation (SD) of 35, 80% power, and significance level of 5% (α = 0.05) yielded a planned sample size of 87 patients. Accounting for potential lost to follow-up brought the target to 100 patients.

Patients selected for the study underwent TKA by five experienced arthroplasty surgeons (TT, PM, AT, BS, GC). Inclusion criteria allowed patients aged 50 to 90 years who had a primary diagnosis of osteoarthritis requiring a primary TKA and had the ability to undergo MRI scanning of the affected limb to be enrolled. Patients were excluded if they had a history of arthroscopic surgery, high tibial or femoral osteotomy, morbid obesity (BMI ≥ 40 kg/m2), varus or valgus malalignment ≥ 15°, presence of metal hardware within the affected limb, or were pregnant.

All patients received an MRI of the affected lower limb prior to surgery, with the data from this MRI allowing for the manufacture of patient-specific ShapeMatch Cutting Guides, of which the surgical procedure has been described previously.18 Following preoperative plan approval by the surgeon, a standard surgical procedure for a Triathlon Cruciate Retaining Primary Total Knee System (Stryker, USA) was performed with either a cruciate retaining or a cruciate substituting polyethylene insert. Table I describes patient demographics.

Table I.

Demographics of clinical trial patients.

Variable Data
Sex, M:F, % 35:65
Side, left:right, % 45:55
Mean age at surgery, yrs, (SD; range) 68.0 (8.3; 49.2 to 85.6)
Meam follow-up length, yrs (SD; range) 4.7 (1.8; 0.5 to 6.6)
Mean preoperative BMI, kg/m2 (SD; range) 30.9 (4.7; 20.2 to 41.3)
  1. SD, standard deviation.

Patients were followed up at six weeks, three and six months, and one, two, and five years postoperatively (Figure 1). Three months postoperatively patients under underwent CT scans of the lower limb in accordance to the Perth protocol.19 The CT scans were used to confirm final component position by measuring the angle formed between the mechanical axis and the prosthetic joint line, which follows the principles for lateral distal femoral angle (LDFA) and medial proximal tibial angle (MPTA). LDFA was measured as the lateral angle formed between the mechanical femoral axis and the prosthetic joint line of the distal femur.20 MPTA was measured as the medial angle formed between the mechanical tibial axis and the prosthetic joint line of the proximal tibia.20 Furthermore, patients also received anteroposterior, mediolateral, and long-leg weightbearing x-rays at one- and five-year follow-up. The long-leg x-rays were used to determine limb alignment using the hip-knee-ankle (HKA) angle, which was expressed as a deviation from 180° with a negative value for varus and a positive value for valgus alignment. The joint line congruence angle (JLCA) was also measured using a technique previously described.16 All radiological measurements were completed by a single reviewer. Patient-reported outcome measures (PROMs) were evaluated using the full Knee Osteoarthritis Outcome Score (KOOS),21 the pain and function components of the Knee Society Score (KSS),17 the Forgotten Joint Score (FJS),22 12-item Short-Form Survey physical and mental composite scores,23 and pain visual analogue scales measuring pain at rest and when mobilizing.24

Fig. 1 
            Strobe diagram outlining patient follow-up in the clinical trial.

Fig. 1

Strobe diagram outlining patient follow-up in the clinical trial.

AOANJRR data

To answer the fourth research question, we used a data matching procedure in the AOANJRR to track the KA TKAs enrolled in the clinical trial. This negated any lost to follow-up and ensured a full cohort was available for revision analysis. Further, a matched cohort in the AOANJRR of other Triathlon Cruciate Retaining Primary Total Knees performed over the same operative period (1 January 2011 to 31 December 2013) was assessed as a time-matched comparator. We assumed the majority of the comparator group (n = 19,692) of osteoarthritic patients were implanted with a mechanical alignment target, because at the time there were no other IDIs or calipered techniques available in the market to execute KA. The data-matching procedure accounted for those patients lost to follow-up in the clinical trial.

Statistical analysis

Data from the clinical trial is summarized using mean, median and standard deviation (SD) for continuous variables, and frequencies and percentages for categorical variables. Statistical analysis and graph preparation were completed using GraphPad Prism V7.0 (GraphPad Software, USA). Alignment as measured from all imaging methods is reported using a histogram of frequency distribution. A Pearson normality test was used to determine the Gaussian distribution of the data and subsequent statistical method for outcome analysis. Longitudinal PROM outcomes were determined using analysis of variance (ANOVA) with the Sidak correction for multiple comparison adjustment. Sub-group analysis by alignment classification was assessed using either linear regression or an unpaired t-test with Welch’s correction for unequal variances. A p-value < 0.05 was considered significant.

Registry analysis was performed by an AOANJRR biostatistician (YP) using SAS software V9.4 (SAS Institute, USA), and was assessed using Kaplan-Meier estimates of survivorship to estimate the time to first revision. Censoring for death or closure of the database at the time of analysis was applied during assessment. Data is presented as unadjusted cumulative percent revision (CPR) with the 95% confidence interval (CI). Hazard ratios (HRs), calculated using Cox proportional hazard models and adjusted for age and sex, were used to make statistical comparisons between each group. All registry tests were two-tailed at the 5% level of significance, and p-values were not adjusted for multiple testing.

Results

The mean postoperative HKA of the kinematically aligned knees measured on one-year postoperative x-rays was 0.4° valgus (-8° varus to 12°; Figure 2). TKA components in this cohort were placed with more femoral valgus (mean LDFA was 1.4° preoperative vs 1.8° postoperative), and with less tibial varus (mean MPTA was -2.5° preoperative vs -1.5° postoperative). In this study, 35% of the tibial components were placed with > 3° varus (Figure 2).

Fig. 2 
          Alignment distribution of Kinematic total knee arthroplasties. Dotted line represents the mean value, arrow represents shift in the mean from preoperative to postoperative. a) One-year postoperative hip-knee-ankle angle measured on long leg weightbearing radiograph; b) preoperative and three-month postoperative lateral distal femoral angle derived from MRI/CT; and c) preoperative and three-month postoperative medial proximal tibial angle derived from MRI/CT.

Fig. 2

Alignment distribution of Kinematic total knee arthroplasties. Dotted line represents the mean value, arrow represents shift in the mean from preoperative to postoperative. a) One-year postoperative hip-knee-ankle angle measured on long leg weightbearing radiograph; b) preoperative and three-month postoperative lateral distal femoral angle derived from MRI/CT; and c) preoperative and three-month postoperative medial proximal tibial angle derived from MRI/CT.

There was a significant improvement in PROMs after TKA (Table II). All scores showed significant improvements from preoperative to one-year postoperative timepoints, and significant improvements from one to five years were found for KOOS Symptoms (p = 0.041) and the FJS (p = 0.011). There was a trend toward improved range of motion (p = 0.064) and KOOS Pain (p = 0.081) over this time, although these did not reach statistical significance.

Table II.

Longitudinal analysis of patient-reported outcome measure scores in the clinical trial (two-year data removed for brevity). All p-values are measured against sequential time-points.

PROMs Preoperative, mean (SD) 1 year, mean (SD) p-value* Five years, mean (SD) p-value*
KOOS Pain 36.2 (17.6) 85.1 (16.7) < 0.001 89.6 (24.3) 0.081
KOOS Symptoms 40.9 (20.9) 83.1 (15.3) < 0.001 87.9 (13.1) 0.041
KOOS ADL 38.1 (20.1) 88.1 (14.4) < 0.001 88.8 (15.1) 0.786
KOOS Sport & Rec 14.5 (21.0) 65.9 (27.3) < 0.001 64.8 (27.0) 0.953
KOOS QoL 19.9 (17.6) 77.1 (20.8) < 0.001 80.2 (21.7) 0.374
SF Physical Component Score 34.1 (7.5) 48.3 (8.9) < 0.001 47.0 (8.7) 0.356
SF Mental Component Score 47.1 (12.5) 52.9 (9.3) < 0.001 53.0 (10.4) 0.999
VAS Rest 5.8 (2.5) 1.2 (1.80 < 0.001 1.0 (1.7) 0.522
VAS Mobilization 7.3 (2.1) 1.4 (2.2) < 0.001 1.2 (1.9) 0.524
International Knee Society Score - Pain 33.0 (14.1) 76.8 (16.5) < 0.001 75.6 (14.0) 0.654
International Knee Society Score - Functional 43.5 (19.3) 77.0 (19.8) < 0.001 71.4 (2.50 0.132
IKSS ROM 109 (17.0) 115 (12.0) < 0.001 119 (13.0) 0.064
Mean FJS N/A 54.5 (30.6) N/A 68.8 (31.20 0.011
  1. *

    Analysis of variance used in longitudinal data.

  1. ADL, activities of daily living; FJS, Forgotten Joint Score; KOOS, Knee Osteoarthritis Outcome Score; QoL, quality of life; ROM, range of motion; SD, standard deviation; VAS, visual analogue scale.

When we classified knees as those with standing HKA within ± 3° (n = 32) of the mechanical axis or outside ± 3° (n = 35), we found no statistical difference in any five-year outcome scores (Table III).

Table III.

Summary of patient-reported outcome scores at five-year follow-up, with patients divided into subgroups of within ± 3° and outside ± 3° (defined as a conservative safe limit) in postoperative limb alignment measured from long-leg weightbearing x-rays.

PROMs HKA within ± 3° from the mechanical axis HKA > 3° from the mechanical axis
n (mean; SD) n (mean; SD) Difference between means (95% CI) p-value*
KOOS Pain 31 (88.1; 16.9) 34 (90.0; 12.8) 1.9 (-5.7 to 9.3) 0.637
KOOS Symptoms 31 (88.2; 15.0) 35 (81; 10.8) -0.1 (-6.5 to 6.5) 0.996
KOOS ADL 31 (88.2; 16.8) 34 (89.8; 12.9) 1.6 (-5.9 to 9.1) 0.677
KOOS Sport & Rec 31 (65.3; 24.6) 31 (68.7; 28.4) 3.4 (-10.1 to 16.9) 0.617
KOOS QoL 31 (81.3; 22.2) 35 (79.8; 22.1) -1.5 (-12.4 to 9.4) 0.786
SF PCS 31 (46.1; 9.3) 35 (48.3; 7.5) 2.3 (-2.0 to 6.5) 0.287
SF MCS 31 (51.2; 9.4) 35 (53.7; 11.8) 2.5 (-2.7 to 7.7) 0.337
VAS Rest 30 (0.9; 1.3) 35 (1.1; 1.8) 0.2 (-0.6 to 0.9) 0.626
VAS Mobilization 30 (1.1; 1.9) 35 (1.3; 2.0) 0.2 (-0.8 to 1.1) 0.791
IKSS Pain 31 (76.1; 13.3) 32 (77.9; 10.6) 1.8 (-4.2 to 7.9) 0.546
IKSS Functional 30 (68.2; 25.1) 34 (74.9; 23.3) 6.7 (-5.5 to 18.8) 0.275
IKSS ROM 32 (119; 11.0) 35 (120.0; 14.0) 0.3 (-5.9 to 6.5) 0.932
FJS 31 (74.8; 36.0) 35 (64.3; 31.9) -10.5 (-25.9 to 4.9) 0.179
  1. *

    Welch's t-test.

  1. CI, confidence interval; FJS, Forgotten Joint Score; HKA, hip-knee-ankle; KOOS, Knee Osteoarthritis Outcome Score; PROMs, patient-reported outcome measures; QoL, quality of life; ROM, range of motion; SD, standard deviation; VAS, visual analogue scale.

To evaluate soft-tissue integrity, we compared the correlation between JLCA and standing HKA at both one- and five-year follow-up. There was a strong correlation at both timepoints and no significant difference in slope (p = 0.610; Figure 3).

Fig. 3 
          Scatterplot correlation between joint line convergence angle (JLCA) and standing hip-knee-ankle (HKA) angle at one and five years postoperatively.

Fig. 3

Scatterplot correlation between joint line convergence angle (JLCA) and standing hip-knee-ankle (HKA) angle at one and five years postoperatively.

The AOANJRR data showed a significant difference in revision (HR 2.20 (1.05 to 4.64); p = 0.037) in KA TKA when compared against the same implant used over the reporting period, (Figure 4 and Table IV).

Fig. 4 
          Cumulative percent revision of primary total knee arthroplasty by model (primary diagnosis = osteoarthritis).

Fig. 4

Cumulative percent revision of primary total knee arthroplasty by model (primary diagnosis = osteoarthritis).

Table IV.

Yearly cumulative percent revision of Triathlon CR/Triathlon primary total knee arthroplasty by model between 1 January 2011 to 31 December 2013 (primary diagnosis = osteoarthritis).

Model 1 yr 2 yrs 3 yrs 4 yrs
Shapematch, CPR (range) 2.1 (0.5 to 8.0) 2.1 (0.5 to 8.0) 3.1 (1.0 to 9.3) 5.2 (2.2 to 12.0)
Other Triathlon, CPR (range) 0.8 (0.7 to 1.0) 1.6 (1.4 to 1.8) 2.0 (1.8 to 2.2) 2.3 (2.1 to 2.5)
Model 5 yrs 6 yrs 7 yrs 8 yrs
Shapematch, CPR (range) 5.2 (2.2 to 12.0) 6.3 (2.9 to 13.4) 6.3 (2.9 to 13.4) 7.4 (3.6 to 14.9)
Other Triathlon, CPR (range) 2.5 (2.3 to 2.8) 2.7 (2.5 to 3.0) 3.0 (2.7 to 3.2) 3.4 (3.1 to 3.7)
  1. CPR, cumulative percent revision.

Seven revision surgeries occurred after kinematic TKA, which are described in Table V. None of the revisions in the kinematically aligned group was performed for loosening. In contrast, 131 tibial revisions occurred in the non-kinematic Triathlon TKAs during the same time (seven years' follow-up). The majority of revision surgeries were performed to address patella issues including mal-tracking, patellar pain or patellar erosion (four out of seven revisions). In these cases, the patella was not initially resurfaced, so a patella component was added during the revision. All other revisions were due to infection (three out of seven revisions).

Table V.

Revision diagnosis of Triathlon CR/Triathlon primary total knee arthroplasty by model between 1 January 2011 to 31 December 2013 (primary diagnosis = osteoarthritis).

Revision diagnosis Shapematch Other Triathlon
n (% primaries revised; % revisions) n (% primaries revised; % revisions)
Infection 3 (3.1; 42.9) 185 (0.9; 30.9)
Instability 74 (0.4; 12.4)
Loosening 73 (0.4; 12.2)
Patellofemoral pain 1 (1.0; 14.3) 67 (0.3; 11.2)
Patella erosion 1 (1.0; 14.3) 57 (0.3; 9.5)
Pain 1 (1.0; 14.3) 47 (0.2; 7.8)
Arthrofibrosis 23 (0.1; 3.8)
Fracture 11 (0.1; 1.8)
Malalignment 11 (0.1; 1.8)
Incorrect sizing 9 (0.0; 1.5)
Wear tibial insert 9 (0.0; 1.5)
Lysis 8 (0.0; 1.3)
Patella maltracking 1 (1.0; 14.3) 7 (0.0; 1.2)
Implant breakage tibial insert 5 (0.0; 0.8)
Synovitis 4 (0.0; 0.7)
Metal-related pathology 2 (0.0; 0.3)
Wear patella 1 (0.0; 0.2)
Other 6 (0.0; 1.0)
Total revision 7 (7.2; 100.0) 599 (3.0; 100.0)
Total primary 97 19,692

Of the seven revisions from the AOANJRR, three were captured within the five-year follow-up in the clinical trial. One infection occurred within 54 days of surgery and was treated successfully by a two-stage wash-out and debridement and polyethylene exchange with implant retention. The second revision was performed due to degenerative arthritic changes on the native patella, which was resurfaced to a cemented all-polethylene component. The third revision was for patella erosion secondary to avascular necrosis and underwent resurfacing two years postoperatively. Subsequently, there were four revisions traced through the AOANJRR, which occurred outside of follow-up in the clinical trial; two of these were for mid-term infection, while the remaining revisions were patella related. Five surgical related adverse events were recorded during the clinical trial, which did not result in a revision. Of these, three manipulations under anaesthetic were performed within 90 days of surgery for stiffness, one patient received surgical repair for lateral subluxation of the patella within the same time frame, and the fifth patient underwent manipulation under anaesthetic for mid-flexion instability and pain three years postoperatively. Details of relative component position, which may have led to stiffness and instability, are detailed in Table VI.

Table VI.

Component position for patients reporting stiffness or instability.

Complication Treatment Time since surgery HKA (+ valgus), ° Combined flexion and posterior slope, ° Tibial rotation relative to posterior condylar axis (+ external), °
Stiffness MUA 30 days -2.4 6 -1
Stiffness MUA 90 days 4.3 16 1
Stiffness MUA 90 days 5.2 5 7
Lateral patella subluxation Surgical repair 90 days N/A 4 4
Mid-flexion instability and pain MUA 3 yrs -1.0 6 8
  1. HKA, hip-knee-ankle; MUA, manipulation under anaesthetic; N/A, not available.

Discussion

To our knowledge, this is the first study to report outcomes and survivorship five years after KA TKA with IDI using a multicentre, multi-surgeon cohort of patients in conjunction with AOANJRR data. We found improved patient outcomes and no difference in PROMs between patients inside (± 3°) or outside (<-3° varus or > 3° valgus) traditional targets for knee alignment. Strong association between JLCA and HKA were identified, with no significant change measured over the follow-up period, indicating that the soft-tissue envelope in patients with high joint line obliquity remain stable over the first five years postoperatively. We report no revisions for aseptic loosening, but found patellar problems to be a risk of revision surgery.

Recent meta-analyses have shown at the very least clinical equivalence or superiority of KA in terms of ROM and early functional scores.13 In our study, 49% of kinematic TKAs were placed in neutral, 25% were placed in varus and 26% were placed in valgus. We report good patient outcomes following kinematic TKA using IDI and equivalent outcomes and survivorship for patients classified as varus or valgus outliers (Table III and Table IV), which is consistent with other reports.11 Currently, the furthest follow-up on aKA cohort has been conducted by Howell et al.14 In this study, 222 knees, which underwent KA using IDI guides, have a ten-year survivorship of 97.5% for revision for any reason and 98.4% for aseptic failure. The 100 knees in our clinical trial are a subset of all the KA TKAs done in Australia and New Zealand with IDI guides from 2011 to 2013. A recent joint registry study reviewing the 416 knees using the same IDI guides in the wider national cohort found zero revisions for tibial loosening at seven years' follow-up.25 Our study supplements this registry study as it provides a spread on implant alignment, where 35% of these TKAs had tibiae placed in > 3° varus. Figure 4 suggests a difference in the survivorship between the two groups, but the larger combined joint registry paper shows the entire cohort of KA TKAs performing just as well as MA TKAs. This provides evidence regarding the concern of potentially poor survivorship of tibial components placed in high varus. However, a high number of patella-related revisions were recorded in the AOANJRR, with a further subgroup of surgical interventions required for poor patella tracking and stiffness, which highlights the need for continued follow-up of TKAs placed in KA.

One of the main concerns for KA is that the valgus of the femoral component might lead to an abnormal patella tracking and high-contact stresses, resulting in an increased patella complication rate.26 We reported complications for stiffness and instability, which were surgically treated with full implant retention. Our complications may be a combination of both an inaccuracy in executing the planned rotation of the femur using IDI and a bias for components placed in more unintended valgus alignment. In our patient cohort, the preoperative limb alignment was centred around mild varus alignment, which has been described by Bellemans et al8 in a non-arthritic population sample. However, the final component alignment was placed in slight valgus, which may be due to the high female bias, which others have shown to predispose towards a valgus alignment.8 In regard to the inaccuracy, this study found a larger change of the intended tibial component position, which has been reported for the same IDI technology,27 and may have also contributed in the overall shift in valgus HKA. Additionally, excessive femoral component flexion stemming from inaccuracy of the same IDI technology has been linked to patellofemoral complications and instability.14 Femoral component position in the sagittal plane may also impact the patellar tracking, as Borukhov et al28 have reported a correlation between the LDFA and the trochlear anatomy in the sagittal plane, highlighting potential limitations of current TKA designs in resurfacing the patellofemoral joint. To avoid these issues in KA, we recommend the use of more accurate tools and 3D planning, such as computer-assisted surgery or robotics, to ensure higher accuracy in component placement.29-31 Furthermore, resurfacing the patella at primary surgery may help minimize potential revisions.

Theoretically, KA should also restore the native joint lines and constitutional alignment without releasing ligaments, which provides more physiological strains in the collateral ligaments than a mechanically-aligned TKA. Furthermore, a kinematically-aligned TKA may result in a joint line, which has a more parallel orientation in relation to the floor during single- and double-leg standing, and more neutral weightbearing than a mechanically-aligned TKA.32 We found a similar correlation between HKA and JLCA to previous work by one of the authors,16 and report no change in this relationship over time. The consistency of this correlation indicates clinically that joint line obliquity in KA does not lead to developmental instability due to increasing ligament laxity over time. This may be linked to the lower adduction moment in KA, and explains the low risk of varus tibial loosening in this cohort.33 The correlations between these findings and the biomechanics through gait warrant further investigation.

This study has several limitations. First, patient x-rays were not assessed for radiological loosening. However, patients generally complain about their knee when radiological changes occur. Second, the comparison group in the AOANJRR includes a range of techniques, and even though majority of surgeons tend to aim for a mechanical alignment, we cannot confirm this for all AOANJRR cases. Third, the interpretation of the results pertains to PCL-sparing TKA, and further work is required to determine the outcomes of KA with posterior stabilized implants. Finally, patients were operated by different surgeons, and the soft-tissue balancing technique may have differed between them.

In conclusion, this paper reports equivalent outcomes regardless of alignment category for KA TKA executed with IDI. There were no revisions for loosening, with significant portion of tibiae placed in varus. We also report the novel finding of consistent association over time between the JLCA and HKA, which may add confidence in extending alignment boundaries. There was a higher than anticipated rate of patella complications which may be due to the poor rotational accuracy of IDI. We advocate for more accurate tools when executing KA, along with continued follow-up to determine the long-term outcomes of KA.


Correspondence should be sent to Gavin Clark. E-mail:

References

1. Noble PC , Conditt MA , Cook KF , Mathis KB . The John Insall Award: Patient expectations affect satisfaction with total knee arthroplasty . Clin Orthop Relat Res . 2006 ; 452 : 35 43 . Crossref PubMed Google Scholar

2. Dai Y , Scuderi GR , Bischoff JE , Bertin K , Tarabichi S , Rajgopal A , et al. Anatomic tibial component design can increase tibial coverage and rotational alignment accuracy: a comparison of six contemporary designs . Knee Surg Sports Traumatol Arthrosc . 2014 ; 22 ( 12 ): 2911 2923 . Crossref PubMed Google Scholar

3. Ibrahim MS , Khan MA , Nizam I , Haddad FS . Peri-operative interventions producing better functional outcomes and enhanced recovery following total hip and knee arthroplasty: an evidence-based review . BMC Med . 2013 ; 11 : 1 9 . Crossref PubMed Google Scholar

4. Oussedik S , Abdel MP , Victor J , Pagnano MW , Haddad FS . Alignment in total knee arthroplasty . Bone Joint J . 2020 ; 102-B ( 3 ): 276 279 . Crossref PubMed Google Scholar

5. Begum FA , Kayani B , Magan AA , Chang JS , Haddad FS . Current concepts in total knee arthroplasty . Bone Jt Open . 2021 ; 2 ( 6 ): 397 404 . Crossref PubMed Google Scholar

6. Howell SM , Howell SJ , Hull ML . Assessment of the radii of the medial and lateral femoral condyles in varus and valgus knees with osteoarthritis . J Bone Joint Surg Am . 2010 ; 92-A ( 1 ): 98 104 . Crossref PubMed Google Scholar

7. Eckhoff DG , Bach JM , Spitzer VM , et al. Three-dimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality . J Bone Joint Surg Am . 2005 ; 87 Suppl 2-A : 71 80 . Crossref PubMed Google Scholar

8. Bellemans J , Colyn W , Vandenneucker H , Victor J . The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus . Clin Orthop Relat Res . 2012 ; 470 ( 1 ): 45 53 . Crossref PubMed Google Scholar

9. MacDessi SJ , Griffiths-Jones W , Harris IA , Bellemans J , Chen DB . Coronal Plane Alignment of the Knee (CPAK) classification . Bone Joint J . 2021 ; 103-B ( 2 ): 329 337 . Crossref PubMed Google Scholar

10. Howell SM , Kuznik K , Hull ML , Siston RA . Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients . Orthopedics . 2008 ; 31 ( 9 ): 857 863 . Crossref PubMed Google Scholar

11. Howell SM , Howell SJ , Kuznik KT , Cohen J , Hull ML . Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category? Clin Orthop Relat Res . 2013 ; 471 ( 3 ): 1000 1007 . Crossref PubMed Google Scholar

12. Howell SM , Papadopoulos S , Kuznik K , Ghaly LR , Hull ML . Does varus alignment adversely affect implant survival and function six years after kinematically aligned total knee arthroplasty? Int Orthop . 2015 ; 39 ( 11 ): 2117 2124 . Crossref PubMed Google Scholar

13. Woon JTK , Zeng ISL , Calliess T , et al. Outcome of kinematic alignment using patient-specific instrumentation versus mechanical alignment in TKA: a meta-analysis and subgroup analysis of randomised trials . Arch Orthop Trauma Surg . 2018 ; 138 ( 9 ): 1293 1303 . Crossref PubMed Google Scholar

14. Howell SM , Shelton TJ , Hull ML . Implant survival and function ten years after kinematically aligned total knee arthroplasty . J Arthroplasty . 2018 ; 33 ( 12 ): 3678 3684 . Crossref PubMed Google Scholar

15. Abdel MP , Ollivier M , Parratte S , Trousdale RT , Berry DJ , Pagnano MW , et al. Effect of postoperative mechanical axis alignment on survival and functional outcomes of modern total knee arthroplasties with cement: a concise follow-up at 20 years . J Bone Joint Surg Am . 2018 ; 100-A ( 6 ): 472 478 . Crossref PubMed Google Scholar

16. McEwen P , Balendra G , Doma K . Medial and lateral gap laxity differential in computer-assisted kinematic total knee arthroplasty . Bone Joint J . 2019 ; 101-B ( 3 ): 331 339 . Crossref PubMed Google Scholar

17. Insall JN , Dorr LD , Scott RD , Norman W . Rationale, of The Knee Society Clinical Rating System . Clin Orthop Relat Res . 1989 ; 248 ( amp;NA ): 13 . Crossref Google Scholar

18. Clark G , Leong A , McEwen P , Steele R , Tran T , Trivett A , et al. Intra-operative reliability of ShapeMatch cutting guide placement in total knee arthroplasty . Comput Aided Surg . 2013 ; 18 ( 5–6 ): 159 165 . Crossref PubMed Google Scholar

19. Chauhan SK , Clark GW , Lloyd S , Scott RG , Breidahl W , Sikorski JM , et al. Computer-assisted total knee replacement. A controlled cadaver study using A multi-parameter quantitative CT assessment of alignment (the Perth CT Protocol) . J Bone Joint Surg Br . 2004 ; 86-B ( 6 ): 818 823 . Crossref PubMed Google Scholar

20. Nam D , Shah RR , Nunley RM , Barrack RL . Evaluation of the 3-dimensional, weight-bearing orientation of the normal adult knee . J Arthroplasty . 2014 ; 29 ( 5 ): 906 911 . Crossref PubMed Google Scholar

21. Roos HP , Lohmander LS , Ekdahl C , Beynnon BD . Knee Injury and Osteoarthritis Outcome Score (KOOS)--development of a self-administered outcome measure . J Orthop Sports Phys Ther . 1998 ; 28 ( 2 ): 88 96 . Crossref PubMed Google Scholar

22. Behrend H , Giesinger K , Giesinger JM , Kuster MS . The “forgotten joint” as the ultimate goal in joint arthroplasty: validation of a new patient-reported outcome measure . J Arthroplasty . 2012 ; 27 ( 3 ): 430 436 . Crossref Google Scholar

23. Jenkinson C , Layte R , Jenkinson D , et al. A shorter form health survey: can the SF-12 replicate results from the SF-36 in longitudinal studies? J Public Health Med . 1997 ; 19 ( 2 ): 179 186 . Crossref PubMed Google Scholar

24. Wewers ME , Lowe NK . A critical review of visual analogue scales in the measurement of clinical phenomena . Res Nurs Health . 1990 ; 13 ( 4 ): 227 236 . Crossref PubMed Google Scholar

25. Klasan A , de Steiger R , Holland S , Hatton A , Vertullo CJ , Young SW , et al. Similar risk of revision after kinematically aligned, patient-specific instrumented total knee arthroplasty, and all other total knee arthroplasty: combined results from the Australian and New Zealand Joint Replacement Registries . J Arthroplasty . 2020 ; 35 ( 10 ): 2872 2877 . Crossref PubMed Google Scholar

26. Ishikawa M , Kuriyama S , Ito H , Furu M , Nakamura S , Matsuda S , et al. Kinematic alignment produces near-normal knee motion but increases contact stress after total knee arthroplasty: A case study on A single implant design . Knee . 2015 ; 22 ( 3 ): 206 212 . Crossref PubMed Google Scholar

27. Thienpont E , Schwab P-E , Fennema P . Efficacy of patient-specific instruments in total knee arthroplasty: a systematic review and meta-analysis . J Bone Joint Surg Am . 2017 ; 99-A ( 6 ): 521 530 . Crossref PubMed Google Scholar

28. Borukhov I , Esposito CI , Ismailidis P , et al. The trochlear sulcus of the native knee is consistently orientated close to the sagittal plane despite variation in distal condylar anatomy . Knee Surg Sports Traumatol Arthrosc . 2021 . Crossref PubMed Google Scholar

29. Clement ND , Calliess T , Christen B , Deehan DJ . An alternative technique of restricted kinematic alignment of the femur and gap balanced alignment of the tibia using computer aided navigation . Bone Joint Res . 2020 ; 9 ( 6 ): 282 284 . Crossref PubMed Google Scholar

30. Abhari S , Hsing TM , Malkani MM , et al. Patient satisfaction following total knee arthroplasty using restricted kinematic alignment . Bone Joint J . 2021 ; 103-B ( 6 Supple A ): 59 66 . Crossref PubMed Google Scholar

31. O’Callaghan WB , Gouk C , Wilkinson MPR , Haztratwala K . Computer-aided surgery-navigated, functional alignment total knee arthroplasty: a surgical technique . Arthroplast Today . 2022 ; 14 : 121 127 . Crossref PubMed Google Scholar

32. Matsumoto T , Takayama K , Ishida K , Hayashi S , Hashimoto S , Kuroda R , et al. Radiological and clinical comparison of kinematically versus mechanically aligned total knee arthroplasty . Bone Joint J . 2017 ; 99-B ( 5 ): 640 646 . Crossref PubMed Google Scholar

33. Shelton TJ , Nedopil AJ , Howell SM , Hull ML . Do varus or valgus outliers have higher forces in the medial or lateral compartments than those which are in-range after a kinematically aligned total knee arthroplasty? limb and joint line alignment after kinematically aligned total knee arthroplasty . Bone Joint J . 2017 ; 99-B ( 10 ): 1319 1328 . Crossref Google Scholar

Author contributions

T. Tran: Funding acquisition, Investigation, Methodology, Writing – original draft.

P. McEwen: Funding acquisition, Investigation, Methodology, Formal analysis, Writing – original draft.

Y. Peng: Formal analysis, Writing - review & editing.

A. Trivett: Investigation, Writing - review & editing.

R. Steele: Investigation, Writing - review & editing.

W. Donnelly: Writing - review & editing.

G. Clark: Funding acquisition, Investigation, Methodology, Writing - review & editing

Funding statement

The author(s) disclose receipt of the following financial or material support for the research, authorship, and/or publication of this article: Stryker Australia Pty Ltd.

ICMJE COI statement

T. Tran reports that the clinical trial was sponsored by Stryker Orthopaedics, which is related to this work, and consultancy for Stryker and Medacta, and payments or honoraria for lectures, presentations, speakers bureaus, manuscript writing, or educational events from Osteosynthesis and Trauma Foundation South Pacific Chapter and AO Alliance, which is unrelated.

Acknowledgements

We would like to acknowledge that data and analysis by the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) was provided free of charge. We would like to thank Dr Jarome Bentley for assistance in measuring radiographic alignment. Finally, we would like to thank Stryker for the funding and support in running this sponsored clinical trial.

Ethical review statement

Ethics was approved at each institution (Dandenong Hospital; HREC Ref: 10050B, The Mater Hospital Pimlico; HREC Ref: MHS20100801-01, Royal Perth Hospital HREC Ref: EC 2010/030, St John of God Subiaco; HREC Ref: 1046).

Open access funding

The authors report that they received open access funding for this manuscript from Stryker Australia Pty Ltd.

© 2022 Author(s) et al. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (CC BY-NC-ND 4.0) licence, which permits the copying and redistribution of the work only, and provided the original author and source are credited. See https://creativecommons.org/licenses/by-nc-nd/4.0/