header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

DIAGNOSING INFECTION: PATHWAYS TO PROGRESS 2016

The Current Concepts in Joint Replacement (CCJR) Winter Meeting, 14 – 17 December 2016.



Abstract

The infected joint arthroplasty continues to be a very challenging problem. No test has 100% diagnostic accuracy for PPI and the treating surgeon must correlate the clinical and radiographic presentation with a combination of blood tests, synovial fluid analysis, microbiological and histopathological evaluation of periprosthetic tissue and intra-operative inspection to reach a definitive diagnosis. Diagnosis should begin with a high index of suspicion for new onset of pain or symptoms in well-functioning joints. Plain radiographs may identify osteolysis or early signs of implant failure and should be promptly investigated further for PPI.

Peripheral blood ESR and CRP remain the most widely used next step for the diagnosis of PPI. Both these tests are widely available, inexpensive, and have a rapid turnaround time in laboratories. The results should be interpreted with caution due to their relative lack of specificity. The sensitivity and specificity values for CRP are approximately 88 and 74%, respectively; while that of ESR is slightly lower at 75 and 70%, respectively. The combined ESR and CRP tests are 96% sensitive for ruling out PPI but the specificity of this combination is as low as 56%. Advanced imaging modalities may be used as a part of the diagnostic algorithm. However, they require expert interpretation and are limited by availability and high costs. When available they have high sensitivity and specificity but their routine use is not recommended and indications have to be individualised in the light of clinical presentation.

In the presence of high clinical suspicion, the clinician should plan synovial fluid analysis. This provides a synovial fluid white cell count with differential cell count, specimen for culture and possibility of analyzing other synovial fluid markers. It is important to note that failed metal-on-metal hip arthroplasties can give a falsely elevated synovial fluid cell count when using automated cell counters. This can be overcome by manually counting cell numbers. Synovial fluid should be directly into blood culture bottles, and antibiotics should be withheld at least 2 weeks prior to aspiration, whenever possible. Cultures also help establish the organism, virulence and sensitivities that help plan subsequent treatment algorithm.

Periprosthetic tissue biopsy provides valuable information in microbiological diagnosis and workup of PPI. Routine use of gram staining is not recommended due to poor sensitivity. However, frozen section may have some role especially when performed by a skilled pathologist. Tissue culture remains the gold standard for diagnosis despite false-positive and false-negative results. Whenever possible multiple samples should be obtained to aid interpretation. A threshold of 2 to 3 positive specimens yielding indistinguishable microorganisms has been recommended to improve sensitivity. Acute inflammation, evidenced by neutrophilic infiltrate on fixed or frozen tissue, is suggestive of PPI and is defined as the presence of at least 5 neutrophils per high-powered field, in at least 5 separate microscopic fields.

Sonication of removed prosthetic components is used to dislodge the biofilm and the associated bacteria from the surface of the implant. The fluid surrounding the implant can be used for culture or analysis.

PCR testing: Synovial fluid aspirate, periprosthetic tissue or sonicate fluid may be subject to molecular diagnosis to amplify genetic material and improve microbiological diagnosis of PPI. This technique has shown increased sensitivity in patients who had received antibiotics within 14 days before implant removal. Results have to carefully interpreted with due consideration for possibility of false positive results.