header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

CLASSIFYING FEMORAL BONE DEFICIENCY: CHOOSING THE RIGHT IMPLANT

The Current Concepts in Joint Replacement (CCJR) Winter Meeting, 14 – 17 December 2016.



Abstract

As the number of patients who have undergone total hip arthroplasty rises, the number of patients who require surgery for a failed total hip arthroplasty is also increasing. Reconstruction of the failed femoral component in revision total hip arthroplasty can be challenging from both a technical perspective and in pre-operative planning. With multiple reconstructive options available, it is helpful to have a classification system which guides the surgeon in selecting the appropriate method of reconstruction.

Type I: Minimal loss of metaphyseal cancellous bone with an intact diaphysis. Often seen when conversion of a cementless femoral component without biological ingrowth surface requires revision. Type II: Extensive loss of metaphyseal cancellous bone with an intact diaphysis. Often encountered after the removal of a cemented femoral component. Type IIIA: The metaphysis is severely damaged and non-supportive with more than 4 cm of intact diaphyseal bone for distal fixation. This type of defect is commonly seen after removal of grossly loose femoral components inserted with first generation cementing techniques. Type IIIB: The metaphysis is severely damaged and non-supportive with less than 4 cm of diaphyseal bone available for distal fixation. This type of defect is often seen following failure of a cemented femoral component that was inserted with a cement restrictor and cementless femoral components associated with significant distal osteolysis. Type IV: Extensive meta-diaphyseal damage in conjunction with a widened femoral canal. The isthmus is non-supportive.

Based on our results, the following reconstructive algorithm is recommended for femoral reconstruction in revision total hip arthroplasty. An extensively coated, diaphyseal filling component reliably achieves successful fixation in the majority of revision femurs and the surgical technique is straightforward. However, in the severely damaged femur (Type IIIB and Type IV), other reconstructive options may provide improved results. Type I: Cemented or cementless fixation can be utilised. If cemented fixation is selected, great care must be taken in removing the neo-cortex often encountered to allow for appropriate cement intrusion into the remaining cancellous bone. Type II: In this cohort of patients, successful fixation was achieved using a diaphyseal fitting, extensively porous coated implant. However, as the metaphysis is supportive, a cementless implant that achieves primary fixation in the metaphysis can be utilised. Type IIIA: An extensively coated stem of adequate length is utilised to ensure that more than 4 cm of scratch fit is obtained in the diaphysis. Type IIIB: Our present preference is a modular, cementless, tapered stem with flutes for obtaining rotational stability. Type IV: Cementless fixation cannot be reliably used in our experience, as it is difficult to obtain adequate initial implant stability that is required for osseointegration. Reconstruction can be performed with impaction grafting if the cortical tube of the proximal femur is intact. However, this technique can be technically difficult to perform, time consuming and costly given the amount of bone graft that is often required. Although implant subsidence and peri-prosthetic fractures (both intra-operatively and post-operatively) have been associated with this technique, it can provide an excellent solution for the difficult revision femur where cementless fixation cannot be utilised. Alternatively, an allograft-prosthesis composite can be utilised for younger patients in an attempt to reconstitute bone stock and a proximal femoral replacing endoprosthesis used for more elderly patients.