header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

EARLY FUNCTIONAL OUTCOMES OF CRUCIATE-RETAINING TOTAL KNEE ARTHROPLASTY USING SMART TIBIAL INSERT TRIAL TECHNOLOGY

The International Society for Technology in Arthroplasty (ISTA), 29th Annual Congress, October 2016. PART 1.



Abstract

Soft tissue balance and alignment have long been known to play an essential role in the long-term success of primary total knee arthroplasty (TKA). Until recently balance was confirmed based on intra-operative feel and experience. In this study we analyzed short-term outcomes of cruciate retaining TKA (CR-TKA) performed with a smart tibial trial device (STT), which provides real-time, intra-operative compartmental load and rotational congruency readings, to a comparable cohort of patients receiving conventional TKA where the same surgeon balanced the compartments based on feel and experience.

Seventy patients received CR-TKA with STT and were matched to one-hundred and eighty non-STT consecutive controls using the same anesthesia, surgical approach, and post-operative rehabilitation and pain management protocol. Both groups were evaluated preoperatively and then post-operatively at three months and one year using Short Form 12 (SF12) and the Western Ontario and McMaster University Osteoarthritis Index (WOMAC) questionnaires. T-tests were used to compare average scores within each cohort, as well as between the two cohorts, for each time interval.

The average age and BMI for the STT cohort were 70.9 ± 9.2 years and 29.8 ± 6.1 kg/m2. Operation length was seen to be 12.0 minutes greater for the STT cohort compared to the conventional cohort (p = 0.0012). The average difference in pressure between medial and lateral compartments was 8.30, 11.49, and 8.65 lbs at 10°, 45°, and 90° respectively. Only 10 cases had a difference greater than 15 lbs between compartments. At 3 months, the STT cohort had significantly higher average function scores on the WOMAC (p=0.046) and higher change from baseline pain scores on the WOMAC (p=0.0016). When scores were stratified into the top 50% and the bottom 50% and the coronal balance was compared, SF12 pain scores and WOMAC function scores at 1 year in the top 50% had greater coronal balance indicated by pressure differences ≤ 15 lbs (p<0.002)

Given the results of this case-control study, we conclude that STT can indeed help the surgeon balance compartmental loads and femoral-tibial rotational congruency and lead to improved short-term physical and functional outcomes in primary CR-TKA.


*Email: