Introduction

Prosthetic replacement remains the treatment of choice for displaced femoral neck fractures in the elderly population, with recent literature demonstrating significant functional benefits of total hip arthroplasty (THA) over hemiarthroplasty. Yet the fracture population also has historically high rates of early postoperative instability when treated with THA. The direct anterior approach (DAA) may offer the potential to decrease the risk of postoperative instability in this high-risk population by maintaining posterior anatomic structures. The addition of intraoperative fluoroscopy can improve precision in component placement and overcome limitations on preoperative planning due to poor preoperative radiographs performed in the emergency setting.

Methods

We retrospectively reviewed clinical and radiographic outcomes of 113 consecutive patients with displaced femoral neck fractures treated by two surgeons over a five-year period. All underwent surgery via the DAA using fluoroscopic guidance, and were allowed immediate postoperative weight bearing without any hip precautions or restrictions. Charts were reviewed for relevant complications, while radiographs were reviewed for component positioning, sizing, and leg length discrepancy. Mean follow-up was 8.9 months.

Results

Mean age was 79.3 years (range, 42 to 101), 73% of patients were women, and mean BMI was 22.6 kg/m2. Ninety patients (80%) received THA while 23 (20%) received unipolar or bipolar hemiarthroplasty. Mean acetabular anteversion was 15.0 degrees (range, 4 to 24) and mean abduction was 39.2 degrees (range, 27 to 51) with 95% of acetabular components in the combined safe zone as described by Lewinnek. Mean radiographic leg-length difference was +2.2 mm (range, −4.9 to +8.8mm). There was no femoral stem subsidence of more than 2mm. Only one patient (0.9%) dislocated postoperatively, who was eventually constrained for recurrent posterior instability 3 months following surgery. Delayed wound healing (6.1%) was the most common postoperative complication.

Conclusions

The direct anterior approach allows a safe, effective, and reproducible approach for treatment of displaced femoral neck fractures, with very low rate of early postoperative instability compared to historical controls. The use of intraoperative fluoroscopy allows excellent component positioning, sizing, and restoration of leg length in spite of inconsistent preoperative radiographs.