Abstract

UKA with mobile bearing is a one of the treatment of medial osteoarthritis. However, some reports refer to the risk of dislocation of the mobile bearing. Past reports pointed out that medial gap might be enlarged in deep flexion position (over 120 degrees), and says that it will lead to instability of the mobile bearing. The purpose of this study is to research the risk factors of enlargement of medial gap in deep flexion position.

We performed 81 UKAs with mobile bearing system from November 2013 to December 2015, and could evaluate 41 knees. This study of 41 knees included 9 males and 32 females, with average operation age of 75.4years(63–89years). The diagnosis was osteoarthritis in 39 knees and osteonecrosis in 2 knees. The UKA(Oxford partial knee microplasty, Biomet, Warsaw, IN) was used in all cases. We performed distal femur and proximal tibia osteotomy using CT-Free navigation system(Stryker Navigation System II/precision Knee Navigation ver4.0). And we inserted femoral and tibial trial component, then we placed an UKA tensioner on the medial component of the knee. Using tensioner under 30 lbs, we measured joint medial gap at 0,20,45,90,130(deep flexion) degrees. When we compared medial gap at 90 degrees position with at 130 degrees, we defined it as ‘instability group’ if there was gap enlargement more than 1mm, and defined it as ‘stability group’ if there wasn't.

We compared this two groups with regard to age, BMI, femoro-tibial angle (FTA), the diameter of anterior cruciate ligament (ACL), tibial angle and tibial posterior slope angle of the implant. We evaluated preoperative and postoperative FTA by weightbearing long leg antero-posterior alignment view X-rays. We measured ACL diameter at its condyle level in coronal view of MRI. Also we evaluated tibial component implantation angle by postoperative CT using 3D template system. These measurement were analyzed statistically using t test.

The stability group contained 26 knees, and the instability group contained 15 knees. Compared with the stability group, the instability group indicated higher FTA (p=0.001). Between 20 and 90 degrees flexion position, there was no change of medial gap.

Dislocation of the mobile bearing is one of the complications of UKA and it will need re-operation. It is said to be caused by impingement of the bearing and osteophyte of femur. However, some reports said that dislocation was happened when the knee was flexed deeply or twisted, and there was no impingement. We think it may means that dislocation could be caused by medial gap enlargement.

This study indicates that higher FTA could be risk factor of dislocation of mobile bearing. It is important to evaluate preoperatively FTA by X-ray.