header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

Hip

THE EFFECTIVENESS OF BLOOD METAL IONS IN IDENTIFYING PATIENTS WITH BIRMINGHAM HIP RESURFACING AND CORAIL-PINNACLE METAL-ON-METAL HIP IMPLANTS AT RISK OF ADVERSE REACTIONS TO METAL DEBRIS: AN EXTERNAL MULTICENTRE VALIDATION STUDY

British Hip Society meeting (BHS) March 2017



Abstract

Recent studies have demonstrated that implant-specific blood metal ion thresholds exist in unilateral and bilateral metal-on-metal (MoM) hip arthroplasty patients, with these thresholds being most effective for identifying patients at low-risk of adverse reactions to metal debris (ARMD). We investigated whether these new blood metal ion thresholds could effectively identify patients at risk of ARMD in an external cohort of MoM hip arthroplasty patients.

We performed a validation study involving 803 MoM hip arthroplasties implanted in 710 patients at three European centres (323=unilateral Birmingham Hip Resurfacing (BHR); 93=bilateral BHR; 294=unilateral Corail-Pinnacle). All patients underwent whole blood metal ion sampling. Patients were divided into those with ARMD (revised for ARMD or ARMD on imaging; n=75), and those without ARMD (n=635). Previously devised implant-specific blood metal ion thresholds (cobalt=2.15μg/l for unilateral BHR; maximum cobalt or chromium=5.5μg/l for bilateral BHR; cobalt=3.57μg/l for unilateral Corail-Pinnacle) were applied to the validation cohort, with receiver operating characteristic curve analysis used to establish the discriminatory characteristics for each respective threshold.

The area under the curve, sensitivity, specificity, positive predictive value and negative predictive value for distinguishing between patients with and without ARMD for each implant-specific threshold were respectively: unilateral BHR=89.4% (95% CI=82.8%-96.0%), 78.9%, 86.7%, 44.1%, 96.9%; bilateral BHR=89.2% (95% CI=81.3%-97.1%), 70.6%, 86.8%, 54.5%, 93.0%; unilateral Corail-Pinnacle=76.9% (95% CI=63.9%-90.0%), 65.0%, 85.4%, 24.5%, 97.1%. The 7μg/l UK MHRA threshold missed significantly more patients with ARMD compared with the implant-specific thresholds (4.9% vs. 2.8%; p=0.0003).

This external multi-centre validation study has confirmed that MoM hip arthroplasty patients with blood metal ion levels below newly devised implant-specific thresholds have a low-risk of ARMD. Compared to implant-specific thresholds, the currently proposed fixed MHRA threshold missed more patients with ARMD.

We recommend using implant-specific thresholds over fixed thresholds when managing MoM hip arthroplasty patients.


Email: