ACETABULAR RECONSTRUCTION USING THE KERBOULL-TYPE REINFORCEMENT DEVICE WITH BONE GRAFT

The International Society for Technology in Arthroplasty (ISTA), 28th Annual Congress. PART 2.



Abstract

Introduction

Acetabular reconstruction of a total hip arthroplasty (THA) for a case with severe bone loss is most challenging for surgeon. Relatively high rate of failure after the reconstruction surgery have been reported. We have used Kerboull-type acetabular reinforcement devices with morsellised or bulk bone allografts for these cases. The purpose of this study was to examine the midterm results of revision THA using Kerboull-type acetabular reinforcement devices.

Patients and methods

We retrospectively reviewed 20 hips of revision THA (20 patients) between February 2002 and August 2010. The mean age of the patients at the time of surgery was 67.4 years (range 45–78). All of the cases were female. The mean duration of follow-up was 6.5 years (range 2.1–10.4). The reasons of revision surgeries were aseptic loosening in 10 hips, migration of bipolar hemiarthroplasty in 8 hips, and rheumatoid arthritis in 2 hips. We classified acetabular bone defects according to the American Academy of Orthopaedic Surgeons (AAOS) classification; we found two cases of Type II and eighteen cases of Type III. In terms of bone graft, we performed both bulk and morsellised bone grafts in 6 hips and morsellised bone grafts only in 14 hips. We assessed cup alignment using postoperative computed tomography (CT) and The post-operative and final follow-up radiographs were compared to assess migration of the implant. We measured the following three parameters: the angle of inclination of the acetabular device (Fig. 1); the horizontal migration (Fig. 2a); and vertical migration (Fig. 2b). Substantial migration was defined as a change in the angle of inclination of more than 3 degrees or migration of more than 3 mm. The pre- and postoperative hip functions were evaluated using the Japanese Orthopaedic Association (JOA) hip score.

Results

The mean cup inclination and anteversion were 38.4 degrees and 10.6 degrees, respectively. The mean change in the angle was 1.9 degrees in inclination of the device. The average horizontal migration was 1.0 mm, and the vertical migration was 2.0 mm. Only one hip showed substantial migration with breakage of the device. This failure case represented a large amount of posterior pelvic tilt in standing position postoperatively. The mean JOA hip score was increased from 46.7 to 74.8.

Discussion

Poor outcome using Kerboull-type reinforcement plate with morsellised bone graft only has been demonstrated by many reports. In these literatures, bulk bone graft was recommended particularly in the case of large bone defect such as larger than half of the rounded plate of the device or more than 2 cm of thickness. In our case series, acetabular reconstruction using a Kerboull- type acetabular reinforcement device and bone graft gives satisfactory mid-term results even with morsellized bone graft only. One possible interpretation is that most of our cases had relatively small bone defect according to the staging of severity of the superior segmental bone loss made by Kawanabe et al. We suggest that the progressive posterior pelvic tilt should be considered to be a risk of poor outcome of the acetabular reconstruction using this device.

To view tables/figures, please contact authors directly.


*Email: