General Orthopaedics

ACCURACY AND POST-OPERATIVE ASSESSMENT OF PEDICLE SCREW PLACEMENT IN SCOLIOSIS SURGERY WITH COMPUTER-ASSISTED NAVIGATION: A META-ANALYSIS

International Society for Computer Assisted Orthopaedic Surgery (CAOS) - 15th Annual Meeting



Abstract

Background

Accurate insertion of pedicle screws in scoliosis patients is a great challenge for surgeons due to the severe deformity of thoracic and lumbar spine. Meanwhile, mal-position of pedicle screw in scoliosis patients could lead to severe complications. Computer-assisted navigation technique may help improving the accuracy of screw placement and reducing complications. Thus, this meta-analysis of the published researches was conducted concentrating on accuracy of pedicle screw placement and postoperative assessment in scoliosis patients using computer-assisted navigation technique.

Methods

PubMed, Cochrane and Web of Science databases search was executed. In vivo comparative studies that assessed accuracy and postoperative evaluation of pedicle screw placement in scoliosis patients with or without navigation techniques were involved and analysed.

Results

One published randomised controlled trial (RCT) and seven retrospective comparative studies met the inclusion criteria. These studies included 321 patients with 3821 pedicle screws inserted. Accuracy of pedicle screw insertion was significantly increased with using of navigation system, while average surgery time was not significantly different with non-navigated surgery. And Correction rate for scoliosis in navigated surgery was not significantly different with non-navigated surgery.

Conclusions

Navigation technique does indeed improve the accuracy of pedicle screw placement in scoliosis surgery, without prolong the surgery time or decrease the deformity correction effect.


*