INTRA-OPERATIVE JOINT GAP KINEMATICS IN OXFORD MOBILE BEARING UNICOMPARTMENTAL KNEE ARTHROPLASTY

The International Society for Technology in Arthroplasty (ISTA), 27th Annual Congress. PART 3.



Abstract

Objective

Mobile bearing unicompartmental knee arthroplasty (UKA) is an effective and safe treatment for osteoarthritis of the medial compartment. However, mobile-bearing UKA needs accurate ligament balancing of flexion and extension gaps to prevent dislocation of the mobile meniscal bearing. Instability can lead to dislocation of the insert. The phase 3 instruments of the Oxford UKA use a balancing technique for the flexion gap (90° of flexion) and extension gap (20° of flexion), thereby focusing attention on satisfactory soft tissue balancing. With this technique, spacers are used to balance the flexion and extension gap. However, gap kinematics in another flexion angle of mobile-bearing UKA is unclear. We developed UKA tensor for mobile-bearing UKA and we assessed the accurate gap kinematics of UKA.

Materials and Methods

Between 2012 and 2013, The Phase 3 Oxford Partial Knee UKA (Biomet Inc., Warsaw, IN) were carried out in 48 patients (71 knees) for unicompartmental knee osteoarthritis or spontaneous osteonecrosis of the medial compartment. The mean age of patients at surgery was 71.6 years and the mean follow-up period was 1.7 years. The mean preoperative coronal plane alignment was 7.4° in varus. The indications for UKA included disabling knee pain with medial compartment disease; intact ACL and collateral ligaments; preoperative contracture of less than 15°; and preoperative deformity of <15°. Each surgery was performed by using different spacer block with 1-mm increments and the meniscal bearing lift-off tests according to surgical technique. We developed newly tensor for mobile bearing UKA which designed to permit surgeons to measure multiple range of the joint medial compartment/joint component gap, while applying a constant joint distraction force (Figure 1). We assessed the intra-operative joint gap measurements at 0, 20, 60, 90 and 120 of flexion with 100N, 125N and 150N of joint distraction forces.

Results

The gaps measured were 0°: 8.6 ± 1.6, 20°: 9.2 ± 1.4, 60°: 9.6 ± 1.2, 90°: 11.1 ± 1.3, 120°: 11.6 ± 1.8 in 100 N, 0°: 9.7 ± 1.7, 20°: 11.2 ± 1.3, 60°: 11.4 ± 1.3, 90°: 11.9 ± 1.5, 120°: 10.4 ± 1.6 in 125 N, 0°: 11.3±1.4, 20°: 11.8 ± 1.3, 60°: 11.1 ± 1.2, 90°: 12.5 ± 1.3, 120°: 11.9 ± 1.6 in 150N (Figure 2). There was a significant difference between full extension to extension (20° of flexion) and flexion (90° of flexion) to full flexion (120° of flexion).

Conclusion

Mobile bearing UKA instrumentation using a balancing technique by spacer block for the flexion gap (90° of flexion) and extension gap (20° of flexion), full extension gap was significantly smaller than extension gap and flexion gap was significantly smaller than full flexion gap in 100N, 125N and 150N of joint distraction forces.