Abstract

Background

High tibial osteotomy is a common procedure to treat symptomatic osteoarthritis of the medial compartment of the knee with varus alignment. This is achieved by overcorrecting the varus alignment to 2–6° of valgus. Various high tibial osteotomy techniques are currently used to this end. Common procedures are medial opening wedge and lateral closing wedge tibial osteotomies. The lateral closing wedge technique is a primary stable correction with a high rate of consolidation, but has the disadvantage of bone loss and change in tibial condylar offset. The medial opening wedge technique does not result in any bone loss but needs to be fixated with a plate and may cause tibial slope and medial collateral ligament tightening.

Purpose

The purpose of this article is to examine correlation between femoral rotational angle and subjective satisfaction of high tibial osteotomy outcome of the range of motion of knee joint.

Materials and methods

The subjects were 15 patients (6 males, 9 females) with primary osteoarthritis undergoing high tibial osteotomy from June of 2004 to August of 2008. They were CT tested on the knee joint before and after high tibial osteotomy. TEA and Akagi's line are analysed as percentages. The Kendall's and Spearman's nonparametric correlation coefficient were used for the statistical tests with 0.5 level of significance.

Results

We observed a negative linear relationship (p = 0.0001) between the femoral component external rotation (measured by TEA) and active and passive ROM. Pearson Coefficient was −0.80, −0.57, respectively. We can find a negative linear relationship (p=0.001) between Akagi's line and passive ROM, and Pearson coefficient was −0.863. Preoperative flexion contracture, age, tibiofibula angle, pain, and other factors do not influence the ROM of the patient. Follow up duration do not influence the ROM of the patient.

Conclusion

The result reveals that femoral rotational angle correlates with not the range of motion of knee joint but subjective satisfaction of the patients. In HTO, beside deformity correction in coronal plane, rotation of the femur contributes postoperative pain relief.