header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

NEUTRAL MECHANICAL ALIGNMENT IN TKA: IS IT NECESSARY?

Current Concepts in Joint Replacement (CCJR) – Winter 2015 meeting (9–12 December).



Abstract

No, Neutral mechanical axis has never been regarded as “necessary” to the success of TKA. In fact it has never been established as “ideal” with published data. Tibial femoral alignment after TKA is important, but it is also an issue that we do not understand completely. Neutral mechanical alignment refers to the relationship between the mechanical axes of the femur and tibia as shown on full length radiographs. “Neutral” means that these axes are collinear, i.e. that a line may be drawn from the center of the hip to the center of the ankle and it will intersect the center of the knee joint. The allure of the “straight line” has led many surgeons to regard a neutral mechanical axis as “perfection” for TKA surgery, but indeed, it is not the usual “normal” alignment for most human knees, nor is it the target for many conventional knee replacements. The “neutral mechanical axis” represents OVERCORRECTION for most knees. Moreland demonstrated in 1987 that few human knee joints are naturally aligned “in neutral”, but with the line from center of hip to center of ankle passing through the medial compartment. This tendency to relative varus mechanical axis in most human knees was corroborated by Bellemans et al in 2012. They substituted the word “constitutional varus” for what would otherwise be known as “normal alignment”.

In general, patients with pathologic or significant varus alignment, whose arthroplasties have been performed competently, are at greatest risk for failure by wear, osteolysis and loosening. This is the prototypical failure mechanism that pre-occupied the surgeons responsible for making knee arthroplasty successful in the 1970s. The first paper to identify varus TKA alignment and failure due to loosening was Lotke and Ecker in 1977. They worked from short radiographs and ushered in an era of careful attention to valgus TKA alignment-not neutral alignment. Correction of varus deformity combined with ligament balancing was probably responsible for making condylar type knee arthroplasties work durably in the early days.

Full length radiographs, used by Kennedy and White in 1987 to study alignment in unicompartmental arthroplasties, provide a more sophisticated method of evaluating knee alignment. These studies must be aligned with correct rotation to be valid. Computerised navigation was probably responsible for some surgeon's dedication to the neutral mechanical axis. The study of Parratte et al from Mayo has received much attention and argued that a neutral mechanical axis did NOT improve success rates at 15 years. It should be noted that these TKA's were expertly performed and even the less well-aligned cases were not “excessively” malaligned. This study does not state that alignment is irrelevant to the success of TKA, but rather that a range of alignments (with stability) might be expected to produce a durable arthroplasty.

Concurrent with these developments has been an interest in “under-correcting” knee deformity or allowing osseous anatomy (with compensation for cartilage loss) guide component position. In truth, it is inaccurate to describe conventional “align and balance” techniques as necessarily seeking a neutral mechanical axis. Most classical alignment techniques do, however, alter the angle of component position from the original articular surface angles and theoretically may not function as well with the native soft tissue environment. Surgeons who would align the TKA identically to the arthritic knee may credit previous generations with improving the technology such that this is a possibility. If every patient is to be aligned with this technique, however, this suggests that soft tissue pathology does not exist. As with all complex issues, glib answers are to be avoided and deep analysis is appropriate.