General Orthopaedics

MONOBLOCK OR MODULAR? MAKING THE RIGHT STEM CHOICE

Current Concepts in Joint Replacement (CCJR) – Winter 2015 meeting (9–12 December).



Abstract

Revision hip surgery is about simplification. As such, a single revision stem makes sense. The most important advantage of Tapered Conical Revision (TCR) stem is versatility - managing ALL levels of femoral bone loss (present before revision or created during revision). The surgeon and team quickly gain familiarity with the techniques and instruments for preparation and implantation and subsequently master its use for a variety of situations. This ability to use the stem in a variety of bone loss situations eliminates intraoperative shuffle (changes in the surgical plan resulting in more instruments being opened), as bone loss can be significantly underestimated preoperatively or may change intraoperatively. Furthermore, distal fixation can be obtained simply and reliably.

Paprosky 1 femoral defects can be treated with a primary-type stem for the most part. All other femoral defects can be treated with a TCR stem. Fully porous coated stems also work for many revisions but why have two different revision stem choices available when the TCR stems work for ALL defects?

TCR stems can be modular or monolithic but there are common keys to success. First and foremost, proper exposure is essential to assess bone defects and to safely prepare the femur. An extended osteotomy is often useful. Reaming distally to prepare a cone for fixation of the conical stem is a critical requirement to prevent subsidence (true for all revision stems). Restoration of hip mechanics (offset, leg length and stability) is fundamental to the clinical result. TCR stems have instrumentation and techniques that ensure this happens, since all this occurs AFTER distal stability is achieved.

Modular TCR versions have some advantages. The proximal body size and length can be adjusted AFTER stem insertion if the stem goes deeper than the trial. Any proximal/distal bone size mismatch can be accommodated. If the surgeon believes that proximal bone ingrowth is important to facilitate proximal bone remodeling, modular TCR stems can more easily accomplish this. Further, proximal bone contact and osseointegration will protect the modular junction from stress and possible risk of fracture.

Monolithic TCR versions also have some advantages. Modular junction mechanical integrity cannot accommodate smaller bone sizes. Shorter stem lengths are not available in modular versions, and shorter TCR stems are an option in many revision cases. The possibility of modular junction corrosion is eliminated and fracture of the stem at that junction, of course, is not possible. The monolithic stem option is less expensive as well.

Consider Modular TCR stems in your learning curve, if you feel proximal bone osseointegration is important and if proximal/distal size mismatch is present. Consider Monolithic TCR stems after your learning curve to reduce cost, when a short stem works, and if a small stem is needed.

Both Modular and Monolithic stems can be used for ALL cases with equal quality of result.