THE SHORT STEM: WHEN LESS IS MORE

Current Concepts in Joint Replacement (CCJR) – Winter 2015 meeting (9–12 December).



Abstract

Use of a short femoral stem for total hip replacement is not a new idea. Morrey first reported on the results of the Mayo Conservative Stem (Zimmer) in 1989. A short femoral stem can also be soft tissue conserving by allowing for a curved insertion track avoiding the abductor attachments. These concepts have made use of a short femoral stem attractive for use in less invasive total hip surgical approaches. The goal of a short femoral stem is to be bone conserving and provide preferential stress transfer to the proximal femur. This may make the short stem desirable for most total hips regardless of surgical approach.

The proximal femur has considerable variability in shape, canal size, and offset. This makes a single geometry short stem potentially unstable in some anatomic variants without having a longer stem to resist varus bending moments or obtain diaphyseal stability. The Fitmore Stem (Zimmer) has addressed these anatomic variants by having three different shaped stems with different offsets.

The presenter has implanted over 1,000 short stems, using them for both standard and less invasive surgical approaches. There is a learning curve when using these short stems. Initially some stems were undersized and inserted in some varus. Thirty-four percent of the first 100 short stems inserted had measurable subsidence. However, all stabilised with no further subsidence. Rarely, subsidence now occurs with attention to preoperative planning for size and improved surgical technique. The surgical technique for insertion of this short stem is different from a conventional length total hip stem. The canal is broached along a curved track with a posterior and lateral moment applied to the broach. Use of the largest size broach that doesn't sink with moderate impaction forces is necessary to maximally contact the medial and lateral proximal cortices to lessen stem subsidence.

Four of over 1,000 stems have been revised for postoperative peri-prosthetic fracture after falls. Two stems were revised for late infection but were not clinically loose. No stems have been revised for aseptic loosening.