MANAGEMENT OF SEVERE UNCONTAINED TIBIAL BONY DEFECTS WITH DOUBLE METAL BLOCKS AUGMENTATION IN TOTAL KNEE ARTHROPLASTY: MINIMUM FIVE-YEAR FOLLOW-UP

The International Society for Technology in Arthroplasty (ISTA), 27th Annual Congress. PART 1.



Abstract

Introduction

The purpose of this study was to evaluate the mid-term clinical and radiological results in patients who were managed by double metal augmentations in proximal tibial uncontained bony defects undergoing primary or revision total knee arthroplasty

Materials and Methods

We performed double metal augmentations in proximal tibial uncontained bony defects undergoing total knee arthroplasty. Out of total 14 patients, 8 patients (4 priamry arthroplasty, 4 revision arthroplasty), mean 61.3 (50–80) years, were available for review at least 5 years follow up. The average follow up period was 86.3(60–99) months. Range of motion, American Knee Society Score were evaluated pre- and postoperatively as a clinical values. Another clinical assessments undertaken at the final reviews, Western Ontario and McMaster Universities osteoarthritis index (WOMAC), Oxford knee score (OKS), Short Form-36 (SF-36), Lower extremity functional scale (LEFS), and Lower extremity activity scale (LEAS) were checked. Radiological results, involving presence of radiolucent lines (RLLs) > 1mm in width, and osteolysis at the block-cement-bone interface were taken under fluoroscopic images at postoperatively and annually thereafter.

Results

At the final follow-up, range of motion was increased from 97.5° to 121.3° and American Knee society score was significantly improved from 30.4 to 92.6 (p=0.03) and functional score from 43.1 to 86.9 (p=0.03). At the final follow-up, average WOMAC score was 10(2–20), OKS was 40.5(33–47), LEFS was 55.8(34–75), and LEAS was 10.9(7–15). There was no broken or deterioration sign at between first and second metal block at radiographically. RLLs at the block-cement-bone interfaces under fluoroscopic images were examined in 3 knees, but didn't cause any failure sign such as osteolysis, or collapse, or instability at final reviews

Conclusions

The clinical and radiological evaluations showed that the double metal augmentations is a favorable and useful way to manage severe uncontained proximal tibial bony defects at least 5 years mid-term follow up period.

Preoperative standing anteroposterior (AP) radiograph (Fig 1) shows severe uncontained proximal tibial bone defects, approximately 23 mm compared with unaffected lateral tibial condyle. AP view of fluoroscopy with medial double metal blocks (10 mm block + down sized 10 mm block) combined intramedullary stem at 60-month follow-up after primary total knee arthroplasty, demonstrating radiolucent line (white arrow) of 2.5 mm width bottom the block (Fig 2). AP view at 92-month follow-up indicating non-progressive stable radiolucent lines (white arrow) at same area without any radiographic failure signs and broken sign between first and second metal block (Fig 3).