General Orthopaedics

THE USE OF BIOTECHNOLOGIES IN REVISION OF PROSTHETIC HIP REPLACEMENT

The International Society for Technology in Arthroplasty (ISTA), 27th Annual Congress. PART 1.



Abstract

INTRODUCTION

The hip arthroplasty implant is currently growing up both in orthopedic and trauma practice. This increases the frequency of prosthesis revision due to implant loosening often associated with periprosthetic osteolysis that determine the failure and lead to a loss of bone substance.

Nowadays there are numerous biotechnologies seeking to join or substitute the autologous or omologous bone use. These biotechnologies (mesenchymal stromal cells, growth factors and bone substitutes) may be used in such situations, however, the literature doesn't offer class 1 clinical evidences in this field of application.

MATERIALS AND METHODS

We performed a literature review using the universally validated search engines in the biomedical field: PubMed / Medline, Google Scholar, Scopus, EMBASE. The keywords used were: “Growth Factors”, “Platelet Rich Plasma”, “OP-1”, “BMP”, “BMP-2”, “BMP-7”, “Demineralized Bone Matrix”, “Stem Cell”, “Bone Marrow”, “Scaffold”, “Bone Substitutes” were crossed with “hip”, “revision”, “replacement” / “arthroplasty”, “bone loss” / “osteolysis.”

RESULTS

The search led to 321 items, of these were considered relevant: as regards the growth factors 21 articles related to in vivo animal studies and 2 articles of human clinical use of BMPs and 1 single article on the use of PRP; as regards the mesenchymal stromal cells 2 items of application in animals; as regards the use of bone substitutes we have analyzed a review of this application.

DISCUSSION

The use of biotechnologies in hip prosthetic revisions has produced conflicting results: autologous growth factors (PRP) have definitely been proven effective in maxillofacial surgery, in animal studies the results of BMPs are inconsistent with articles that validate their use and others that don't recommend it. Clinical application has demonstrated, today, the limited use of BMP-7 in revisions with even an increased risk of early re-mobilization, PRP appears to be rather effective only in the early stages of peri-prosthetic osteolysis. The mesenchymal cells can increase the chances of recovery and integration of the grafts but an important variable is the number of cells that are still alive after the impaction of the graft which affects their vitality. The bone substitutes appear to be safe and very useful, particularly if applied in order to implement the omologous bone, which is still the most scaffolds used in this surgery.

CONCLUSIONS

The systematic review of the literature has shown an important lack of clinical studies regarding the use of biotechnologies for prosthetic revisions. It is therefore difficult to draw guidelines that regulate the application, prospective randomized clinical studies are therefore needed to validate its effectiveness.