header advert
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

General Orthopaedics

USE OF SONICATION IN ‘ASEPTIC’ FAILURE OF ORTHOPAEDIC PROSTHESIS

European Bone And Joint Infection Society (EBJIS) 34th Annual Meeting: PART 2



Abstract

Clear differentiation between aseptic failure and prosthetic joint infection remains one of the goals of modern orthopaedic surgery. The development of new diagnostic methods enabled more precise evaluation of the etiology of prosthetic joint failure. With the introduction of sonication an increasing number of culture-negative prosthetic joint infection were detected.

The aim of our study was to evaluate culture-negative prosthetic joint infections in patients who were preoperatively evaluated as aseptic failure.

For the purpose of the study we included patients planed for revision surgery for aseptic failure. Intraoperatively acquired samples of periprosthetic tissue and explanted prosthesis were microbiologicaly evaluated using standard microbiologic methods and sonication. If prosthetic joint infection was discovered, additional therapy was introduced.

Between October 2010 and April 2013 54 patients were operated (12 revision knee arthroplasty, 42 revision hip arthroplasty). 10 (18,6%) patients had positive sonication and negative periprosthetic tissue sample, 5 (9,2%) patients had positive tissue samples, but negative sonication, in 9 (16,7%) patients both tests were positive and in 30 (55,5%) patients all microbiologic tests were negative. The microbiologic isolates of sonicate fluid were in 12 cases coagulase-negative staphylococci, in 3 cases P.acnes in 3 cases mixed flora, in 1 case enterococcus and in 1 case SA. From periprosthetic tissue cultures 5 samples have yielded coagulase-negative staphylococci in 5 cases P.acnes in 2 cases mixed flora, in 1 case enterococcus and in 1 case SA were isolated.

With the increasing number of patients requiring revision arthroplasty, a clear differentiation between aseptic failure and prosthetic joint infection is crucial for the optimal treatment. Sonication of explanted material is more successful in the isolation of pathogens compared to periprosthetic tissue cultures. Sonication of explanted prosthetic material is helpful in the detection of culture-negative prosthetic joint infections.


E-mail: