POST-TRAUMATIC SEPTIC NONUNIONS: THE ROLE OF EXTERNAL FIXATION IN AN AFRICAN CONTEXT

European Bone And Joint Infection Society (EBJIS) 34th Annual Meeting: PART 2



Abstract

To present the results achieved with the use of external fixation techniques in treating 52 cases of post-traumatic and post-surgical septic non-union in a low resources setting.

From 2006 to 2014 52 patients were treated for post-traumatic septic non-union of the lower and upper limb bones. Clinical records and radiographs were reviewed; telephone interviews were done for patients unable to reach our institution.

There were 39 males and 13 females, with an average age at the time of admission of 29 years (the youngest patient was 8 years old, the oldest 81). Tibia was involved in 43 cases (24 right side, 19 left side), femur in 9 (4 right, 5 left) and left humerus in 1. All the patients, except two, had been treated in other institutions before admission. At presentation, 19 patients had an external fixator in situ, 18 patients had infected osteosynthesis, 15 had exposed necrotic bone, with loss of soft tissues.

In 20 cases hardware removal, debridement and sequestrectomy were followed by application of an external fixator. In 31 cases bone transport was done; the fixator was monolateral in 27 cases. In 1 case sequestrectomy and external fixation were followed by a vascularized fibula graft. Bifocal bone transport was utilized in one patient while the bone transport procedure was associated to limb lengthening in 10 patients.

Plastic surgery was required in 13 patients. Rotational flaps, vascularized free flaps and extensive skin grafts were all used.

The site of non union was cured in all the patients, in an average time of 11 months (from 4 to 32). Two patients required an amputation a few months after the end of the treatment. There was need for fixator adjustment and screws replacement in 21 patients. Non-union at the docking point was observed in 5 patients; it was septic in two of them. There was need of skin-plasty in 2 cases for skin invagination. In 3 cases an extensive skin ulcer was observed during the transport procedure.

Limb length discrepancy was corrected in 10 patients. A residual limb shortening was observed in 14 patients. Ankle fusion, knee fusion, foot drop, sensory loss in the foot, reduced range of joint motion were also observed.

The external fixator plays a pivotal role in the treatment of septic non unions, especially in low resources setting. The treatment is long and costly. Strict medical supervision is necessary during the entire process.