TREATMENT OF BONE LOSS AFTER INFECTION WITH AUTOLOGOUS BONE GRAFT OBTAINED WITH THE RIA SYSTEM

European Bone And Joint Infection Society (EBJIS) 34th Annual Meeting: PART 2



Abstract

The aim of this paper is to describe the technique and evaluate the effectiveness of the RIA system in the first cases of bone loss treated by the authors with this technique.

Between January 2010 and January 2011, ten patients were treated with an average age of fourty six years, with infected bone loss as a result of open fractures in various bone segments, with multiple failed treatment attempts, including three humeri, four femurs and three tibiae. The average size of the initial bone loss was 4 cm, varying from 1 to 8 cm. In 4 patients it was used simultaneously a Ilizarov apparatus with acute compression of the focus, in two patients a Ender pin and monolateral external fixator, three other cases with a SAFE nail with core with antibiotics and in one case an osteosynthesis with a plate and screws. The RIA was introduced with a percutaneous technique with a one pass drilling. The graft thus collected was mixed with appropriate antibiotics and aplied at the defect. The volume of the harvested graft, complications of the donor and recipient and the final results was recorded.

The review showed that the average volume of graft was 60 cc, from 20 to 90 cc. In two female patients older than 70 years with osteoporosis, insufficient bone of poor quality was obtained. Problems included a case of iatrogenic fracture of the donor site, due to poor surgical technique and a case of relapse of the nonunion. Regarding the effectiveness of grafts extracted with the RIA system, 90% of the cases achieved consolidation in average of 5 months after grafting, range 3–9 months.

This short experience with the RIA system showed that it is an attractive method allowing a rapid removal of a large volume of bone graft with a minimally invasive approach and a short learning curve. It is not indicated in elderly patients with osteoporosis and those with a narrow medullar canal less than 11 mm. Special attention must be done to the need to choose a drill no larger than 1 mm of the diameter of the isthmus, to do a single entry point and with only one drill passage to prevent the weakening of the donor site.